Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC work allotted | |
| 2 | L2₹7.8 L+₹4,807 (0.62%)Rejected-Finance H NO 13 A BHARAT COLONY 121002 | FARIDABAD | FARIDABAD | HARYANA | 121002 | L2 | Rejected-Finance Rate are at higher side | |
| 3 | L3₹8.2 L+₹37,747 (4.84%)Rejected-Finance | L3 | Rejected-Finance Rate are at higher side | |
| 4 | L4₹8.5 L+₹70,189 (9.00%)Rejected-Finance VPO TIGAON MOHALLA JAIDAR PATTI NEAR NIMKA MOD TIGAON 121101 | TIGAON | FARIDABAD | HARYANA | 121101 | L4 | Rejected-Finance Rate are at higher side | |
| 5 | L5₹8.6 L+₹84,233 (10.8%)Rejected-Finance | L5 | Rejected-Finance Rate are at higher side |
| Sl No | Description | Qty | Unit | RI Infrastructure L4 | V.V. CONSTRUCTIONS L2 | K.B Contractors L1 | RAWAT ENTERPRISES L3 | LOHIYA ENTERPRISES CONTRACTOR L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing 100mm dia PVC Band ISI mark. | 2 | Each | 800 ₹1,600 | 500 ₹1,000 Lowest | 500 ₹1,000 Lowest | 500 ₹1,000 Lowest | 600 ₹1,200 |
| 2.00 | Providing and fixing of 8 K.W. electric meter connection with 3 phase energy meter from DHBVN at site in favor of MCF including i.e. Connection Security, file Process Charge, Connection Charge, Inspection fee, Test Report fee, other Expenses and installation of 1 Nos. Approved energy meter LandT make with 2 KVA Capacitor and required Cable. | 1 | Each | 44,000 ₹44,000 | 45,000 ₹45,000 | 43,500 ₹43,500 Lowest | 45,000 ₹45,000 | 46,000 ₹46,000 |
| 3.00 | Material required- Mechanical and Electrical works, detail given below.
Supply and fixing of 2½” Pump Nipple G.I. new making with flange | 1 | Each | 2,400 ₹2,400 | 750 ₹750 Lowest | 2,400 ₹2,400 | 2,500 ₹2,500 | 2,600 ₹2,600 |
| 4.00 | Supply and fixing of 2½” MS Clamp HD | 1 | Each | 1,400 ₹1,400 | 750 ₹750 Lowest | 1,400 ₹1,400 | 1,500 ₹1,500 | 1,600 ₹1,600 |
| 5.00 | Providing and fixing of PVC Pipe 4`` dia in manhole. | 30 | Metre | 450 ₹13,500 Lowest | 750 ₹22,500 | 450 ₹13,500 Lowest | 550 ₹16,500 | 700 ₹21,000 |
| 6.00 | Supply of PVC Tee 6”x6”x 4” dia @1250 | 1 | Each | 1,200 ₹1,200 | 1,250 ₹1,250 | 1,200 ₹1,200 | 1,000 ₹1,000 Lowest | 1,200 ₹1,200 |
| 7.00 | Supply and fixing of GI 4 inch Horizontal both side flange | 1 | Each | 4,500 ₹4,500 | 1,000 ₹1,000 Lowest | 3,800 ₹3,800 | 2,500 ₹2,500 | 2,800 ₹2,800 |
| 8.00 | Supply and Fixing of GI pipe 4 inch vertical both side flange | 1 | Each | 4,500 ₹4,500 | 1,000 ₹1,000 Lowest | 3,800 ₹3,800 | 2,500 ₹2,500 | 2,800 ₹2,800 |
| 9.00 | Supply of fixing duck foot bend 4 inch D/F | 1 | Each | 4,500 ₹4,500 | 750 ₹750 Lowest | 3,800 ₹3,800 | 2,500 ₹2,500 | 3,000 ₹3,000 |
| 10.00 | Supply and fixing of Tee 4`x4`x4` | 1 | Each | 4,500 ₹4,500 | 1,000 ₹1,000 Lowest | 4,000 ₹4,000 | 2,500 ₹2,500 | 3,500 ₹3,500 |
Tender Value
₹8.2 L
EMD Value
₹16,350
Closing Date
26 Feb 2026, 6:00 pmClosed
SATPAL
Municipal Corporation Faridabad
Provision of 01 No. DTH Tube-well bore at ward office dabua, Ward No.11, Faridabad.
2026_HRY_504000_1
20260726A658 1405 43F0 B298 66BB8A0507A1284ULB
Open Tender
Civil Works
Works
120 days
Faridabad (MC)
2 documents required · 2 mandatory
₹1,000
₹16,350
Yes
19 May 2026
19 Feb 2026
27 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
Providing and fixing 100mm dia PVC Band ISI mark.
Providing and fixing of 8 K.W. electric meter connection with 3 phase energy meter from DHBVN at site in favor of MCF including i.e. Connection Security, file Process Charge, Connection Charge, Inspection fee, Test Report fee, other Expenses and installation of 1 Nos. Approved energy meter LandT make with 2 KVA Capacitor and required Cable.
Material required- Mechanical and Electrical works, detail given below. Supply and fixing of 2½” Pump Nipple G.I. new making with flange
Supply and fixing of 2½” MS Clamp HD
Providing and fixing of PVC Pipe 4`` dia in manhole.
Supply of PVC Tee 6”x6”x 4” dia @1250
Supply and fixing of GI 4 inch Horizontal both side flange
Supply and Fixing of GI pipe 4 inch vertical both side flange
Supply of fixing duck foot bend 4 inch D/F
Supply and fixing of Tee 4`x4`x4`
Supply and fixing of 5 to 7.5 H.P submersible motor pump 40 stage (C.R.I B.S Kirloskar make ).
Percentage BoQ
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
All HSR Items as per DNIT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_582697.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .