Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹8.6 L+₹15,795 (1.87%)Rejected-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance L2 | |
| 3 | L3₹8.7 L+₹29,297 (3.47%)Rejected-Finance 12 1 FERRIGHAT ROAD PO BHATPARA DIST NORTH 24 PGS WEST BENGAL 743123 | BHATPARA | NORTH 24 PGS | WEST BENGAL | 743123 | L3 | Rejected-Finance L3 | |
| 4 | L4₹8.7 L+₹30,313 (3.59%)Rejected-Finance NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L4 | Rejected-Finance L4 | |
| 5 | L5₹20.7 L+₹12.2 L (144.7%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA WEST BENGAL 700033 UDYAM WB 10 0047115 | KOLKATA | WEST BENGAL | 700033 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | BALAJI FIRE PROTECTION SYSTEMS L5 | A.K.ENTERPRISE L2 | DIAMOND ELECTRIC SALE AND SERVICE L1 | Creative Projects L3 | MOON LIGHT L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable OPC complied Multisensor Detector (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 105 | Nos | 1,850 ₹1,94,250 Lowest | 2,095 ₹2,19,975 | 2,670 ₹2,80,350 | 2,650 ₹2,78,250 | 2,156 ₹2,26,380 |
| 2.00 | Supply, Installation, Testing & Commisioning of OPC complied Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 6 | Nos | 2,950 ₹17,700 | 2,790 ₹16,740 Lowest | 3,210 ₹19,260 | 3,290 ₹19,740 | 2,893 ₹17,358 |
| 3.00 | Supply, Installation, Testing & Commissioning of Addressable OPC complied Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 6 | Nos | 3,800 ₹22,800 Lowest | 4,805 ₹28,830 | 4,500 ₹27,000 | 6,800 ₹40,800 | 4,944 ₹29,664 |
| 4.00 | Supply, Installation, Testing & Commissioning of Addressable OPC complied Monitor Modules ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 6 | Nos | 1,850 ₹11,100 | 2,146 ₹12,876 | 2,950 ₹17,700 | 650 ₹3,900 Lowest | 2,209 ₹13,254 |
| 5.00 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable OPC complied Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 2 | Nos | 1,600 ₹3,200 | 1,877 ₹3,754 | 4,500 ₹9,000 | 650 ₹1,300 Lowest | 1,893 ₹3,786 |
| 6.00 | Supplying, Installation, Testing and Commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 19 | Nos | 50 ₹950 | 72 ₹1,368 | 200 ₹3,800 | 20 ₹380 Lowest | 74 ₹1,406 |
| 7.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make : Finolex/ Gloster/ RR Kable/ Polycab/ KEI ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 4,000 | Mtr | 105 ₹4,20,000 | 107 ₹4,28,000 | 75 ₹3,00,000 | 44 ₹1,76,000 Lowest | 109 ₹4,36,000 |
| 8.00 | Supply, Installation,Testing & Commisioning of Microprocessor based 2 loops fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) fully networkable with each loop capable of taking 125/250 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 10000 event memory, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 2 hours with integral battery charger complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire) | 1 | No | 1,85,000 ₹1,85,000 | 1,08,596 ₹1,08,596 Lowest | 1,26,755 ₹1,26,755 | 3,15,222 ₹3,15,222 | 1,15,975 ₹1,15,975 |
| 9.00One time rectification/cleaning contract of following types of Addressable type fire detection system (Make Siemens) as mentioned below | ||||||||
| 9.01 | Multi detector/Heat detector | 575 | Each | 1,850 ₹10,63,750 | 37 ₹21,275 | 25 ₹14,375 | 20 ₹11,500 Lowest | 38 ₹21,850 |
Tender Value
Refer Docs
EMD Value
₹17,550
Closing Date
11 Apr 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Cooch Behar Electrical Division
Executive Engineer Cooch Behar Electrical Division
WBPWD/EE/CED/e-NIQ-47/2024-25
2025_WBPWD_829869_1
WBPWD/EE/CED/e-NIQ-47/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
28 days
Cooch Behar
Please refer tender documents
6 documents required · 6 mandatory
₹17,550
Yes
10 Sept 2025
21 Mar 2025
17 Apr 2025
21 Mar 2025
11 Apr 2025
21 Mar 2025
Amount
Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable OPC complied Multisensor Detector (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supply, Installation, Testing & Commisioning of OPC complied Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supply, Installation, Testing & Commissioning of Addressable OPC complied Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supply, Installation, Testing & Commissioning of Addressable OPC complied Monitor Modules ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable OPC complied Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supplying, Installation, Testing and Commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make : Finolex/ Gloster/ RR Kable/ Polycab/ KEI ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Supply, Installation,Testing & Commisioning of Microprocessor based 2 loops fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) fully networkable with each loop capable of taking 125/250 devices, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered The panel shall have in built rectifier, provision for external & internal printer (if required),Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 10000 event memory, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 2 hours with integral battery charger complete as required. (Make : Siemens/ Bosch /Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
One time rectification/cleaning contract of following types of Addressable type fire detection system (Make Siemens) as mentioned below
Multi detector/Heat detector
Hooter
Monitor Module
Checking, cleaning & Commissioning of existing FDS panel (Siemens Make) as per direction of E.I.C.
Note1:Rate Should be Quoted with inclusive of all taxes, duties, cess as applicable.
A.K.ENTERPRISE (BID ID -6312862)
Creative Projects (BID ID -6305567)
MOON LIGHT (BID ID -6269201)
BALAJI FIRE PROTECTION SYSTEMS (BID ID -6304690)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .