Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LQualified C 62 VIVEK VIHAR EAST DELHI DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹4.7 L+₹18,968.50 (4.23%)Qualified OFFICE E2 MANALI ARCADE NEAR D MART PADMAVATI PUNE SATARA ROAD PUNE MAHARASHTRA 411009 PUNE MAHARASHTRA 411009 | PUNE | MAHARASHTRA | 411009 | L2 | Qualified MSE, MII, Category: SC | |
| 3 | L3₹4.8 L+₹28,836 (6.43%)Qualified HOUSE NO 369 ASNABAD RANCHI PATNA ROAD JHUMRI TELAIYA KODERMA JHARKHAND 825409 | KODERMA | JHARKHAND | 825409 | L3 | Qualified MSE, MII, Category: General | |
| 4 | L4₹5.0 L+₹46,836 (10.5%)Qualified 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L4 | Qualified MSE, MII, Category: General | |
| 5 | L4₹5.0 L+₹46,836 (10.5%)Qualified PLOT 8 AND 9 SAI DHAM MARG SECTOR 86 TIGAON ROAD FARIDABAD FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | L4 | Qualified MII |
Tender Value
₹6.9 L
EMD Value
₹20,700
Closing Date
3 Sept 2024, 2:00 pmClosed
Conducting structural audit for Rehabilitation
6777136
GEM/2024/B/5284763
Two Packet Bid
Structural Audit to Bldgs 1,Structural Audit to Bldgs 2,Structural Audit to Bldgs 3,Structural Audi
60 days
Andaman And Nicobar Islands; South Andamans
Total value wise evaluation
BOQ
4 documents required · 4 mandatory
3 yrs
50%
₹20,700
3 Sept 2024
13 Aug 2024
3 Sept 2024
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Structural Audit to Bldgs 1 | Conducting structural audit for Rehabilitation for the G 2 building nos
Visual Survey Visual inspection for surface damages damage classification The visual inspection shall largely cover areas of high distress corrosion moisture leakage abnormal variations in structure algae and fungus growth efflorescence etc Visual inspection would be docemented in the form of worksheets photographic records and distress over drawings Simple tools and instruments like camera with flash light magnifying glass binoculars chisel and hammer etc shall be used for measiring the distresses as per site requirement | 1 | Job | South Andaman | 60 |
| 2 | Structural Audit to Bldgs 2 | Rebound Hammer Test Nos of tests not less than 80 For determining the estimated compressie strength of concrete and iniformity of concrete in terms of surface hardness as per IS 13311 Part-2-1992 ASTM C 805-02 BS 60891981 and BS 1881Part 202 BS-EN13791 also establishing correlation chart between rebound hammer and other confirmatory test for having estimated in-sity strength of concrete if required In absence of the confirmatory test strength data will be generated on the basis of empirical formula obtained from the callibration chart | 1 | Job | South Andaman | 60 |
| 3 | Structural Audit to Bldgs 3 | Ultrasonic Pulse Velocity Test Nos of tests not less than 80 for ascertaining the quality of concrete uniformity of concrete in terms of soundness and density of concrete as per IS 13311 Part -1-1992 ASTMC597-83 BS 60981981 and BS 1881Part 203 and BS EN13791 also establishing correlation chart between ultrasonic Pulse velocity and other confirmatory test having estimated insitu strength of concrete if required | 1 | Job | South Andaman | 60 |
| 4 | Structural Audit to Bldgs 4 | Core Extraction and Testing Nos of tests not less than 20 Extracting the concrete core samples following the codal provisions and evaluating the properties fck value grade of concrete in the laboratory from the core samples selected IS 4562000 IS 5161959 IS 11992002 ASTM C-42 without encountering any steel reinforcement from the RCC members covered under the study at specified locations by site in-charge | 1 | Job | South Andaman | 60 |
| 5 | Structural Audit to Bldgs 5 | Half Cell Potential Test Nos of tests not less than 60 Measuring the half-cell/ surface potentials at selected locations on RCC members of the structures covered under the study to understand the extent of reinforcement corrosion in terms of probable risk of corrosion of steel bar as per ASTM C876 The rate shall include surface preparation moistening concrete surface | 1 | Job | South Andaman | 60 |
| 6 | Structural Audit to Bldgs 6 | Carbonation Test Nos of tests not less than 30 Measurement of carbonation depth by phenolphthalein spray test at selected locations drilled powder sample or concrete core sample as per site condition on RCC members of the structures covered under the study to see the depth of carbonation as per BS EN 146302006 BS EN 132952004 Cover depth is also measured at the same location to know the ratio of Carbonation depth | 1 | Job | South Andaman | 60 |
| 7 | Structural Audit to Bldgs 7 | pH value Nos of tests not less than 20 to check alkanity fo concrete as per relavent BS 5328 ACI 2012R-92 and ACI-318-99 IS 4562000 BS 8110 | 1 | Job | South Andaman | 60 |
| 8 | Structural Audit to Bldgs 8 | Report Interpretation and Recommendation Preparing and submitting comprehensive report consisting of findings from visual inspection test data interpretation of results conclusions and final recommendations along with sketch indicating the location of the test recommending suitability of the buildings for special repair or otherwise and suggesting methodology for retrofitting of the buildings
Note- i Each type of test will be done in all buildings as per scope of work No of tests in each building should be optimised in such a way that it gives best possible representation of the structural health of the building ii Report should be duly vetted from IIT/NIT iii The HD quality site photographs and video shall be provided in a good quality of CD/DVD along with soft copy | 1 | Job | South Andaman | 60 |
| 9 | Structural Audit to Bldgs 9 | Repairing Methodology and retrofitting scheme for structural serviceability and safety periodic maintenance scheme futuristic protection of structures The recommendation for structural repair and rehabilitation to the structures shall have detailed technical specificatiosn materials to be used and design details vulnarability indices and order of urgency to repair Suggesting retrofitting methodology to increase the load carrying capacity of structural members Incl preparation and submission of BOQ and conceptual shceme for Rehabilitation/ retrofitting works feasible and economic options with Rate analysis material specifications execution drawing for strengthening of structure along with technical specifications and periodic inspection and maintenance | 1 | Job | South Andaman | 60 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_6777136.pdf
GEM_BID
dcs_2024-08-13-13-05-16_6b4baf4664a326b8317d1391aaa95a34.pdf
BOQ
boq_item_sample_file_-25_2024-08-13-13-05-16_d2de46cc1b74e74eae2bae12f867fb2d.csv
BOQ
ATCcoun_61c75bee-75fe-42bf-818e1723534771738_cndwivedi106-cgo@gov.in.docx
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .