Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.9 L+₹4.9 L (24.3%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹32.8 L+₹12.8 L (64.0%)Rejected-Finance | L3 | Rejected-Finance High Rate Quoted |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Mar 2024, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair/Maint of external electric work, street light and LT UG cables and LT Panels at North Camp, East Camp Loonkaransar and Mahajan ASCON NODES under AGE MFFR under GE (N) Bikaner
2024_MES_641608_1
CA No CWE BKN-Token No. 93/2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹70,000
Yes
27 Mar 2024
9 Feb 2024
16 Mar 2024
9 Feb 2024
9 Mar 2024
24 Feb 2024
9 Feb 2024 - 17 Feb 2024
Amount
Notes applicable to Schedule ‘A’ :- (i) The items considered in this Schedule ‘A’ are for fault repair and maintenance at MFFR. The rates quoted shall deemed to be included this aspect. (ii) The contractor must deploy a dedicated fault investigation and rectifying team and contractor must attend the complaint within 24 Hours and resolve within 48 Hours. If contractor fails to rectify the fault within 48 hours, a penalty at the rate of Rs. 1000/- per day shall be imposed on the contractor after 24 hours till the fault is rectified. A complaint Log Book in this regard shall be maintained by the contractor duly signed by the Engineer-in-Charge.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
All as per serial item No. 2.00 here-in-before but depth exc 1.5m and not exc 3m complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
S&F pre-stressed concrete pole 9 metre long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping/pedestal and marking pole number in letters & figures of size not less than 8cm height, including taking out old unserviceable pole complete all as specified & as directed Note :- Excavation, earthwork, PCC in foundation & coping shall be measured and paid for separately.
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations of poles, filling, mass concrete and similar works, complete all as specified and as directed. Note : Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundations of stay assembly, filling, mass concrete and similar works, complete all as specified and as directed.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
Supply, laying, jointing and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 Volt grade of cross sectional area 120 Sqmm, 3.5 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, including dismantling & taking out old unserviceable LT cable, complete all as specified & as directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
All as per serial item No 11.00 here-in-before but of size 95 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 70 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 50 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 35 Sqmm 3.5 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 25 Sqmm 4 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 16 Sqmm 2 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 10 Sqmm 2 Core complete all as specified & as directed.
All as per serial item No 11.00 here-in-before but of size 6 Sqmm 2 Core complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for indoor/outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 50 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for indoor/outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for indoor/outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm, including dismantling & taking out old unserviceable jointing kit, complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for straight through hot shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for straight through hot shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
M&L for cable jointing kit for LT 1100 Volt cable for straight through hot shrinkable type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
S&F in replacement of Light Emitting Diode (LED) based street/security light fitting, 45 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 4500 lumens, correlated colour temperature shall be minimum 5000 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed, complete all as specified and as directed.
S&F in replacement of Light Emitting Diode (LED) based Flood light fitting, 100 Watt with & including LED lamp, housing made up of LM6 pressure epoxy powder coated die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens/watt, a minimum system lumen output of not less than 11500 lumens, Correlated Colour Temperature (CCT) shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 300 V, AC, frequency 50-60Hz, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 10%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/ polycarbonate/ toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed, complete all as specified and as directed.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminium conductor size 4 sqmm (nominal area) & drawing into hollow street light pole from fitting to junction box or fitting to cover head line complete all as specified & as directed.
Supply and fixing in replacement of change over switch 200 Amp, four pole, 415 volt, cubical type and including making fixing arrangement in existing LT control panel and with proper connection of as per existing system complete all as specified & as directed. Make : C&S Cat Part CSSDF200B4CO or equivalent Cat Part in make CG/L&T/Siemens /Alstom.
Repair the following work to existing bus bar chamber (Pillar box) outdoor cubical type factory made vermin protected dust proof, water proof made out of MS sheet 1.6mm thick and 50cmx6mm thick angle iron base frame having insulated bus bar aluminum 200 Amp capacity 3 Phase with neutral bus bar including fixing in PCC bed block complete all as required at site and complete all as specified and directed by Engineer-in-Charge with following :
Welding of brocken /cracked joints of the feeder pillar box
Replacement to locking arrangement of the feeder pillar box as per sample existing
Painting with one coat of synthetic enamel paint after applying one coat of red oxide as per primer complete all as specified and directed.
Supply and fixing in replacement of U/S feeder Pillar box outdoor cubical type factory made vermin protected dust proof with canopy, water proof made out of MS sheet 1.6mm thick and 50x6mm thick angle iron base frame having insulated bus bar aluminum 200 Amp capacity 3 Phase with neutral bus bar including fixing in PCC bed block complete all as specified and directed.
M&L for Boring of holes of 80/100mm bore under road, pavement, hard standing, etc by trench less technology using necessary machine / manually without disturbing the top surface suitable for passing the GI protection pipe / cables, complete all as specified and as directed.
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on 11 KV HT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, etc including dismantling and taking down old existing unserviceable aluminium conductor steel reinforced (ACSR) of any size/ type/ capacity, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
M&L for repairing of broken ACSR vessal / squarel / ferrot / mink conductor after proper shutdown of electric supply and jumpring /cut points changing the damaged / burned conductor, cable ends, change over MCCBs conductor broken due to wind/ storm and binding with the aluminium wire etc and changing the damaged pin/ disc insulators and replace the broken conductor, repairing the faults in the 11/0.44 KV outdoor/ indoor electric panels at sub stations complete all as specified and directed. Note:- (i) Cost of fues wire minor spares, aluminium binding wire shall be deemed included in the above quoted items. (ii) Cost of items that is pin insulator, disc insulator etc shall be measured and paid separately under respective items. (iii) Contractor take complaints from complaints cell (JE E/M) and rectify the same day and duly singed by the users and deposited the same. one down break down / complaint by attended shall be Each Job.
S&F Pin type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.
S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, including dismantling & taking down old unserviceable insulator, complete all as specified & as directed.
Supply and fixing in replacement of Maintenance Free battery capacity 80 AH, 12 Volts with proper copper wire complete all as specified & as directed.
M&L for Earthing to equipments with & including galvanised mild steel earth plate electrode of size 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4 mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to transformer / GOD / Panel / equipment body / test point, GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
S&F in replacement of MCCB 4 Pole 100 Amps, thermal magnetic adjustable having, breaking capacity 16 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 125 Amps, thermal magnetic adjustable having, breaking capacity 25 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 160 Amps, thermal magnetic adjustable having, breaking capacity 16 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 200 Amps, thermal magnetic adjustable having, breaking capacity 36 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 400 Amps, thermal magnetic adjustable having, breaking capacity 36 KA, 415 Volt including making fixing arrangement in existing LT control Panel including any addition / alteration to the panel to accommodate the new MCCB & making connections as per existing system complete all as specified and directed.
Taking down carefully the defective street light fitting 36/45/72 watt from the poles/walls and refixing the same on poles/walls after repair defects complete all as specified and directed. Note : A Team of workers for emergency are available inside the camp for 24 hours and T&P i.e ladder and vehicle will provided by the contractor.
Supply and fixing in replacement Driver unit with surge protection suitable for LED street light fitting of capacity 36 to 45 watt complete all as specified and directed. Make : Bajaj/Phillips/CG
Supply and fixing in replacement Driver unit with surge protection suitable for LED street light fitting of capacity 72 to 80 watt complete all as specified and directed. Make : Bajaj/Phillips/CG
Supply and fixing in replacement 90 Degree LED Module 3030SMD 150-160 LM/W LED with Array Lens complete for watt 36 to 45 watt complete all as specified and directed. Make : Bajaj/Phillips/CG
Supply and fixing in replacement 91 Degree LED Module 3030SMD 150-160 LM/W LED with Array Lens complete for watt 72 to 90 watt complete all as specified and directed. Make : Bajaj/Phillips/CG
S&F in replacement of suitable clamp of LED solar light of capacity 15 Watt complete all as specified and directed.
S&F in replacement of charger control/ circuit for solar battery 12 volt including connecting to existing wiring circuit complete all as specified and directed.
S&F in replacement of solar plate / Solar cell module of capacity 12 volt 75 watt complete all as specified and directed.
Taking out old U/S Panel any type and any description and size carefully by disconnecting LT Cables outgoing/ incoming, carefully after ensuring proper shutdown including breaking up old PCC complete all as specified and directed.
Taking out old U/S street light or street light fittings with brackets from poles, walls etc any type and description complete all as specified and directed.
B.K. ROY & SONS
LAKSHMI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .