Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.9 LAccepted-AOC | L1 | Accepted-AOC REASONABLE LOWEST BIDDER | |
| 2 | L2₹67.0 L+₹4.0 L (6.31%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹67.1 L+₹4.1 L (6.52%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹67.9 L+₹4.9 L (7.69%)Rejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹71.9 L+₹8.8 L (14.0%)Rejected-Finance 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹71 L
EMD Value
₹1.3 L
Closing Date
4 Jul 2022, 6:00 pmClosed
Chief Engineer RND Secunderabad
Chief Engineer RND Picket Secunderabad 500003
RENOVATION OF USD P-62 BUILDING OF ADE BANGALORE
2022_MES_528847_1
82620
Open Tender
Civil Works
Item Rate
180 days
ADE Bangalore
Class B
Category a i
7 documents required · 7 mandatory
₹1,000
Yes
GE RND East
₹1.3 L
Yes
29 Aug 2022
6 Jun 2022
11 Jul 2022
6 Jun 2022
4 Jul 2022
27 Jun 2022
Amount
Taking down shutters of any description exceeding 1.0sq.m but not exceeding 2.0sq.m and removing from site, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified, complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.), complete all as specified
Sheet glass, 4.0 mm thick, ordinary quality and glazing with rubber beadings suitable for aluminium frame work, in square not exceeding 0.5 sq. m in each pane, complete all as specified and directed.
Figured glass, pin head type, 4.8 mm thick, ordinary quality and glazing with rubber beadings suitable for aluminium frame work, in square not exceeding 0.5 sq. m in each pane, complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section of 150mm long, complete all as specified and directed.
Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21, complete all as specified and directed.
Aluminium handles, cast type, anodised, oval shaped or 'D' type, 100mm long, complete all as specified and directed.
Venetian blinds, vertical type, 100mm slot width of approved fabric and powder coated aluminium top rails etc., including dismantling and taking old damaged blinds, complete all as specified and directed. Note: - Colour, design and shade shall be as approved by GE.
Taking down chowkats or frames not exceeding 1.5sq.m each (without taking off shutters from the frames), complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification, complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification, complete all as specified and directed.
Aluminium handles, cast type, 150mm long, anodised, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of debris to a distance not exceeding 100 m, complete all as specified and directed.
Plain cement concrete (1:3:6), type C1 (using 20mm graded stone aggregate), 50mm thick, as in sub base etc., finishing surface even and fair without using extra cement, complete all as specified and directed.
Plain cement concrete (1:2:4) type B0 (using12.50mm graded stone aggregate) 25mm thick as in floors/pavings, finishing surface even and fair without using extra cement, complete all as specified and directed.
Vitrified ceramic tiles, light shade, 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc., set and jointed in neat cement slurry and pointed in epoxy grout to match, laid over and including 15 mm thick screed bed in CM (1:4), complete all as specified and directed.
Vitrified ceramic tiles, dark shade, 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc., set and jointed in neat cement slurry and pointed in epoxy grout to match, laid over and including 15 mm thick screed bed in CM (1:4), complete all as specified and directed.
Vitrified ceramic tiles, light shade, 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting, set and jointed in neat cement slurry and pointed in epoxy grout to match, laid over and including 10 mm thick backing coat in CM (1:3), complete all as specified and directed.
Non-skid ceramic coloured joint free tiles of size 400 x 400 x 8 to 9 mm thick (Minimum) (B-II a / B-II b Grade), as in floors etc., set and jointed in neat cement slurry and pointed in epoxy grout to match, laid over and including 15 mm thick screed bed in CM (1:4), complete all as specified and directed.
Glazed ceramic tiles of size 350 mm x 250 mm x 7 mm thick / 450 mm x 350 mm x 7 mm thick (B-III a Grade), in vertical surfaces such as skirtings / dado etc., set and jointed in neat cement slurry and pointed in epoxy grout to match, laid over and including 10mm thick backing coat in CM (1:3), complete all as specified and directed.
Granite (of any type) work (table rubbed and polished), 25mm thick as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick screed bed in CM (1:4), complete all as specified and directed.
Granite (of any type) work (table rubbed and polished), 25mm thick as in risers of stair case, skirting/dado and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 10mm thick backing coat in CM (1:3), complete all as specified and directed.
Rendering 10 mm thick in CM (1:3) mixed with water proofing liquid as per manufacurer instructions over cleaned roof surface, finished fair and even, complete all as specified and directed. Note:- Water proofing liquid shall be measured and paid separately under respective item of this Schedule.
APP based polymeric membrane minimum weighing 3.5 kg / sq.m and minimum 3.0 mm thick reinforced with polyester non woven fabric (weight not less than 150 gms / sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 litre/sq.m by forced application, complete all as specified and directed. The complete roof treatement shall be consisting of as under :- (i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 litre / sq.m (ii) Laying of APP based membrane of specified thickness and weight. (iii) Applying two coat of aluminium paint @ 100 ml / sq.m
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
Taking down cement plaster (backing coat) any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc., to receive plaster, complete all as specified and directed.
Rendering 15mm thick in CM (1:4) in two layers (10mm thick and 5mm thick mixed with water proofing compound) on fair faces of brick work or concrete surfaces and finishing the surface fair and even with out using exta cement, complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid separately under respective item of this Schedule.
Rendering 10mm thick in CM (1:4) on surfaces other than fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Plastering 5 mm thick in CM (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of old plastered or unplastered of undecorated surfaces of walls, chajjas, balcony, facias etc., and applying two coats of interior dust proof plastic emulsion paint over a coat of primer over and including 2.0mm thick interior grade wall care putty, finished even and smooth, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls and applying two coats of interior dust proof plastic emulsion paint over a coat of primer over and including 2.0mm thick interior grade wall care putty, finished even and smooth, complete all as specified and directed.
Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed.
Preparation of old painted surfaces wood and wood based materials, of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of new plastered surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
Preparation of old plastered surfaces of ceilings and applying one coat of white wash, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of 100% preimum acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 13489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre /10 Sq.m over and including priming coat of exterior primer applied @ 0.90 litre /10 Sq.m, complete all as specified and directed.
Complete removal of existing treatment including preparation of walls and applying two coats of 100% preimum acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 13489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre /10 Sq.m over and including priming coat of exterior primer applied @ 0.90 litre /10 Sq.m, complete all as specified and directed.
Taking up or down steel tubing and connections, 15mm bore and removing to store yard, complete all as specified and directed.
Taking up or down steel tubing and connections, 20mm bore and removing to store yard, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, fixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
GI tubing medium grade, galvanised with all fittings including short lengths, ffixed to ceilings and walls with and including provision of suitable size of clamps or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 20mm bore of pipe, complete all as specified and directed.
Rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top), 1000 litre capacity (ISI embossed), hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed.
Bib cock, chromium plated, two way, double handle with flange, 15mm bore, fixed in repairs, complete all as specified and directed. Make: - Cat Part No. 7212 of Prayag or techno commercially equivalent make/model as approved by GE
Stop valves, cast copper alloy, fancy type, chromium plated, with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Vitreous china squatting pan, ‘Orissa’ pattern, of size 580 x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe), including 'P' or 'S' trap, fixed in repairs, complete all as specified and directed.
Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., with and including provision of seat cover black closed pattern with flat bottom with mild steel CP hinging device, complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, 32mm dia flush pipe and connections to pipes and fixing of chain and pull, or lever, if any, fixed in repairs, complete all as specified and directed.
Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
Ball valves, 20mm size, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 15mm-142gms / 20mm - 210 gms / 25mm-455gms / 40mm - 690 gms), fixed in repairs, complete all as specified and directed.
Vitreous china urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe), fixed in repairs, complete all as specified and directed.
Vitreous china urinal partition, white of size 310x700 mm, fixed in repairs, complete all as specified and directed.
Vitreous China wash hand basin, flat back, size 550mm x 400mm white, excluding taps, waste pipe, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand fixed in repairs, complete all as specified and directed.
Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, 15mm bore, complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
Tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
Toilet paper holder, fixed to walls with chromium plated brass screws, fixed in repairs, complete all as specified and directed.
Angle cock, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, 15mm bore, fixed in repairs, complete all as specified and directed.
Health faucet, chromium plated, fancy type, brass body with 1.0metre length stainless steel braided rubber hose pipe and wall hook, fixed in position to wall, complete all as specified and directed. Make: - Cat Part No. BEA-81 of Prayag or techno commercially equivalent make/model as approved by GE
Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as floors, complete all as specified and directed.
Screed bed or bedding layer, 15mm thick in CM (1:4) for laying floor finishes, complete all as specified and directed.
Demolition and breaking up drain pipes of 100mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
UPVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or floors, 110mm bore, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, including ashlar facings, dressed stone work and precast concrete articles, PCC solid block masonry etc., complete all as specified and directed.
Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of debris to a distance not exceeding 100 m, complete all as specified and directed.
Reinforced cement conrete M20 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Supply only integral water proofing compound
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
Hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm longg, complete all as specified and directed.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions, complete all as specified and directed.
Stainless steel railing / posts of SS-304 grade of required size fixed to sideso f platform/path/stairways etc., incluiding suitable size of steel bolts / fstners / fittings etc., complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular frame plate and white cover of required modules for housing switches, sockets, regulators etc., including 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. (i) One light point controlled by one, one way switch. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 77.00 here-in-before, but for one fan point controlled by one, one way switch, complete all as specified and directed.
All as per Sl. Item No. 77.00 here-in-before, but for one 3 pin, 6 Amps switch socket outlet point on independent board, complete all as specified and directed.
Point wiring complete with 2.50 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 2.50 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one 3 pin,16 Amps switch socket combination, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
Modular switch one way, 6 Amp, 230 Amps, one module, (ISI marked), complete all as specified and directed.
Modular switch one way, 16 Amp, 230 Amps, one module, (ISI marked), complete all as specified and directed.
Stepped type, electronic fan regulator, modular type, 120W, two module, fixed as required, complete all as specified and directed.
Modular socket, 6A - 2/3 pin combined 2 module, (ISI marked), complete all as specified and directed.
Modular socket 6A/16A - 2/3 pin combined, 2 module, (ISI marked), complete all as specified and directed.
Ceiling rose, 3 terminal / PVC / polycarbonate, isolated body, complete all as specified and directed.
Sub main wiring complete with 4 runs of 10.0 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit minimum 25mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 10.0 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down existing unserviceable sub main wiring, complete all as specified and directed. NOTE:- (i) Four runs of 10.0 sq.mm copper conductor,Two runs of 10.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Sub main wiring complete with 4 runs of 16.0sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit minimum 32mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 16.0sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down existing unserviceable sub main wiring, complete all as specified and directed. NOTE:- (i) Four runs of 16.0 sq.mm copper conductor,Two runs of 16.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Sub main wiring complete with 2 runs of 6.0sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit minimum 25mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of 6.0sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down existing unserviceable sub main wiring, complete all as specified and directed. NOTE:- (i) Two runs of 6.0 sq.mm copper conductor, One run of 6.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Sheet metal encloser, powder coated, VTPN DB double door, 8 way, 415 Volts, with and including MCCB TPN 125 Amps, 25 KA as incomer, IP 43 protection, shrouded neutral bar & pan assembly with flexible link cement spill protector, door earthing, fixed in repairs, complete all as specified and directed. Make:- Cat No. 811895 (Optimum F2+24) of Indo Asian or techno-commercially equivalent model in Legrand / L&T / Schneider / C & S / Havells / HPL / Standard
Sheet metal encloser, powder coated, Vertical Distribution Board, double door, 4 way, 415 Volts, with 200 Amps rated bus bar, fixed in repairs, complete all as specified and directed. Make:- Havells or techno-commercially equivalent model in Legrand / L&T / Schneider / C & S / HPL / Standard / Indo Asian
MCB SP 6 to 32 Amps, 240 Volt, 50Hz, 'C' curve type, 10KA breaking capacity, complete all as specified and directed.
MCB TPN 16 to 32 Amps, 415 Volt, 50Hz, 'C' curve type, 10KA breaking capacity, complete all as specified and directed.
Taking down ceiling fans, 1200/1400mm sweep, single phase, removing blades and refixing after cleaning, servicing, greasing, painting with one coat of synthetic enamel paint by sprayer with and including filling of cavities with filler and replacement of connecting cable with copper conductor flexible cable of suitable size, complete all as specified and directed.
Taking down exhaust fans, 300/450mm sweep, single phase, removing blades and refixing after cleaning, servicing, greasing, painting with one coat of synthetic enamel paint by sprayer with and including filling of cavities with filler and replacement of connecting cable with copper conductor flexible cable of suitable size, complete all as specified and directed.
Taking down wall mounted fan, removing blades and refixing after cleaning, servicing, greasing and replacement of connecting cable with copper conductor flexible cable of suitable size, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI wire of 4mm dia by means of bolts, nuts, washers etc., GI wire shall be protected by 20mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:12:4) type B-1 earth chamber with 40mm x 40mm x 6mm MS angle iron frame, 40mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc., with plastering 15mm thick in CM 1:6 internally and upto 150mm below GL externally, PGI funnel with wire mesh, complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre.
Earth lead 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required , complete all as specified and directed.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 15mm bore of pipe, complete all as specified and directed.
DLP U-PVC cable trunking system and acessories snap on trunking 80 x 50 mm with out cover, complete all as specified and directed. Make:- Cat No. 010412 of Legrand or techno commercially equivalent Model in / L&T / Schneider / C & S / HPL / Standard / Indo Asian / Havells
Flexible cover only of 65 mm width suitable for PVC trunking 80 x 50 mm, complete all as specified and directed. Make:- Cat No. 010521 of Legrand or techno commercially equivalent Model in / L&T / Schneider / C & S / HPL / Standard / Indo Asian / Havells
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface, for laying conduits & cables on floors / walls and making good disturbed surfaces with cement mortar, complete all as specified and directed.
LED 36 Watts, 230 Volts, slim down light durable batten fitting with decorative end caps, complete all as specified and directed. Make:- Cat No. TRIMLINE, LDL-36 CDL of Crompton Greaves or techno commercially equivalent Model in BAJAJ/PHILIPS/Havells
LED recessed / surface 2' x 2' type, 36 Watts, 230 Volts, light fitting, 5700K, complete all as specified and directed. Make:- Cat No. POARIS III, LCTLSN-36-CDL of Crompton Greaves or techno commercially equivalent Model in BAJAJ/PHILIPS/Havells
Building security LED, 30 Watts, 230 Volts, light fitting, complete all as specified and directed. Make:- Cat No. FREEDOM+ LSTS-30-CDL of Crompton Greaves or techno commercially equivalent Model in BAJAJ/PHILIPS/Havells
Suspended LED luminaire, 40watts, 230Volts, (of size 200 x 106 60mm) uniquely clean & simple lighting system offering continuous, uniform lines of light across ceiling, complete all as specified and directed. Make:- Cat No. CONSTA 1144LP40WLED857SPMMAWH of Havells or techno commercially equivalent Model in BAJAJ/PHILIPS/CG
Post top lantern, new generation, 40watts, 230Volts, 360 degree energy saving environmental friendly, long life, aesthetically designed with good indirect symmetrical light distribution of capacity, cast aluminium landscape luminaire with high power as light source IP 65 protection all pre wired fixed on the existing GI pipe including testing, complete all as specified and directed. Make:- Cat No. MAPLE, LPTO-40-CDL of Crompton Geaves or techno commercially equivalent Model in BAJAJ/PHILIPS/ Havells
MCB SPN 32 Amps, 240 Volt, 50Hz, 'C' curve type, 10KA breaking capacity, complete all as specified and directed.
Drilling and filling of cracks in RCC structure wherever directed and instructed with pressure grouting with pressure of 40 PSI with cement slurry by adding plasticizer CEBEX 100 or Dr Fixit Pidicrete AM 207 or equivalent @ 225gms/ml per 50 Kg cement, applying with suitable mechanical pump/gun including materials, drilling holes of 18mm dia and fixing PVC Nozzles of suitable size @ 01 No (Point) per Sqm and grouting until point of refuse then the Nozzles shall be removed the next day and the holes shall be plugged with plugging compound, complete all as specified and directed.
Ashraya Nirman
S CHANDRASHEKAR (SREE BUILDERS)
PRAGATHI BUILDERS
ABHISHEK CONSTRUCTIONS
Lucky Enterprises
devan enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .