| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹7.0 L+₹4,200 (0.61%)Rejected-AOC | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹7.3 L+₹36,995 (5.34%)Rejected-AOC | L3 | Rejected-AOC Not being lowest | |
| 4 | L4₹7.5 L+₹58,825 (8.50%)Rejected-AOC | L4 | Rejected-AOC Not being lowest | |
| 5 | L5₹8.3 L+₹1.4 L (19.8%)Rejected-AOC | L5 | Rejected-AOC Not being lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Nov 2019, 6:00 pmClosed
GE970EWS
GE970EWS C/O 56 APO
As described in Bill of Quantities
2019_MES_292269_1
CA NO GE 970 EWS- 37 /2019-20
Open Tender
Civil Works
Item Rate
270 days
HAFT CHINAR AND TATTOO GROUND
Class E Category a(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
GE970EWS
₹20,000
Yes
1 Feb 2020
24 Oct 2019
20 Nov 2019
24 Oct 2019
19 Nov 2019
7 Nov 2019
Amount
M&L for Cleaning/ clearing and maintanace of sewage lines, man holes including CI/PVC stacks, gully traps, floor traps, under ground lines any depth by removing any type of blockage from drain/ drain pipe up to and including 250mm dia by mechinal machine method ( using pipe cleaning machine with auger function standard or specialised) from manholes and flushing with water with pressure using water hose pipe connected with water trolleys after cleaning including manholes, sludges/sludge effluent to be disposed off as directed by enge -in- charge including taking off manholes covers and refixing the same after cleaning of sewage lines /manholes cleared/cleaned. under this item lines to be maintained and kept fully functional by removing any type of blockage for 11 months from the date of commencement of first work order. the cost of this operation/ provision shall be deemed to be included in unit rate quoted by the contractor. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-II to receive the complaint slips daily at 0830 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs.
M&L for Dewatering of contaminated waste effulient from septic tank/ Soakage well of any capacity and depth by vehicle mount sewage cleaning machine and jetting and disposal to low lying area upto distance of 2 Km incl taking off and refixing manholes covers etc complete all as directed by Engineer-in-Charge. (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-II to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE before 48 hrs as per complaint slip time.
Cleaning of septic tank of any capacity and depth incl inlet chamber, outlet chamber removing out all sludge, Silt, residue waste material (organic/inorganic nature) by vehicle mount sewage cleaning machine and required manpower after plugging the incoming sewage line and depositing the waste upto 2 km distance and burrying the same in suitable size of pit and covering the same with earth and removal of surplus soil all as directed by engineer in charge. (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-II to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE before 48 hrs as per complaint slip time. Notes :(a) Cost of excavation of pit and covering the same with earth is to be included in unit rate. (b) Rates against item No.1 to 3 includes for : (i) Cleaning and clearing/disposing off all the sludge/ sewage contaminated water in solid / semi solid / liquid state from sewage lines, manholes etc as detailed in above item No.1 to 3 will be carried out during the 1st 3 months from the date of commencement of work order N0.1 and there after shall be maintained for blockage free and smooth functioning of all the sewage lines and related sewage items as detailed in item N0.1 above for a period of eight months i.e., the date of completion of contract given in work order No.1. Engagement one supervisor along with two sweeper cum sewage drain attendent along with T&P required on daily basis for a period of eleven month for attending the daily sewage related complaints. the complaints shall be collected daily at 0830 hours from the office of Engr-in-charge by contractor/Contractor's supervisor and shall be got signed from the user occupant after clearing the complaints. These complaint slips will also be got signed at Engr-in-charge office daily after the satisfactory completion of each complaint. No complaint shall be kept pending/unattented for a period of 48 hours. any damage to man hole covers, gully tarp covers, CI assess doors of CI pipes any dia, PVC pipes/fitting, 'P' traps, floor traps during the process of cleaning/clearing shall be made good by the contaractor by the contractor by replacing same by new items without ant extra cost to the govt. (ii) If contractor fail to complete the complaint within stipulated period i.e 48 Hrs a recovery of Rs 300 per complaint per day will be levied.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm dia ( salit glazed ware, AC or rienforced conc ) set in cement Mortar complete all as specified and directed.
Demolition and breaking up drain pipes 200 mm dia ( salit glazed ware, AC or rienforced conc ) set in cement Mortar complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) complete all as specified and directed.
Material & labour for salt glazed stone ware drain pipe Grade-A 150mm bore laid in trenches, jointed and tested as per IS-651-1980 complete all as specified and as directed.
Material & labour for salt glazed stone ware drain pipe Grade-A 200mm bore laid in trenches, jointed and tested as per IS-651-1980 complete all as specified and as directed.
M&L for concrete bed to drain pipes 150mm bore laid bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 complete all as specified and directed by Engr-in-Charge.
All as per item no. 10 above but dia 200mm bore.
Returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing surplus spoil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks complete all as specified and directed by the Engr-in-Charge.
All as per item no. 15 above but except bricks.
Material & labour for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands plinth cources, roof kerbs or mud stops, benching, coping, bed plates, parapets, water throughs and the like etc including weathering, slightly rounded or chamfered angles throating etc complete including necessary form work complete all as specified and directed.
Material & labour for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete etc complete all as specified and directed.
Material & labour for 15mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Cutting into existing manhole removing existing drain making good to wall and rendering cutting out branch channel and making good benching for 150mm dia pipe in cement concrete 1:2:4 complete all as specified and directed by Engr-in-Charge.
Demolition of RCC of any description and in any position not otherwise specially provided for sunken floor complete all as specified and directed.
M&L for Precast Cement concrete1:2:4 type B-1 using (20 mm graded crushed stone aggregate)but in landing ,cover slabs (for manhole etc)chullah hoods,chajjas water trough,mangers,shelves and similar articles with plain face set in CM1:4 incl demolition of cement concrete (reinforced) of any discription and in any position not otherwise specifically provided complete all as specified and directed.
Material & labour for mild steel high yield strength TMT bars 6 to 8 mm dia cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Supply & fix in repairs squatting pan WC Orissa pattern size 580mm x 440mm white with integral foot rest (excluding flushing cistern) with P or S trap including provision of lime concrete bedding including breaking up existing damaged WC seat and connecting flush pipe etc making good to match with existing surfaces complete all as specified and directed.
Supply & fix in repairs vitreous china wash down water closet pan (pedestal pattern) white including plastic water closet sheet cover white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and including mild steel chromium plated jet fixed to water closet with 360mm wide x 390mm high and 600mm long flexible pipe complete all as specified and directed.
Supply & fix in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action with top push type button with inlet ball valve and float including flush pipe, ball valve, handle, bracket PVC short bend etc. complete all as specified and directed.
Supply and fix in repairs, urinal, flat back or corner wall type of size 600x355x265mm white (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 110 mm PVC (SWR) bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
S&F in repair 110 mm PVC (SWR) with access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm PVC (SWR) bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm PVC (SWR) with access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
Supply & fix in repairs PVC (SWR) 110mm branch piece single (Single 'Y') equal or unequal complete all as specified and directed.
Supply & fix in repairs PVC (SWR) 75mm branch piece single (Single 'Y') equal or unequal complete all as specified and directed.
Supply & fix in repairs PVC 'P' or 'S' traps dia 110mm complete all as specified and directed.
Material & labour for stack clamps suitable for 75/110mm bore CI pipes / 110mm bore PVC pipes made out of 50 x 5mm flat iron and 16mm dia round iron stays including nuts and bolts and securing end of stays to wall or in roof, complete all as specified and directed.
Supply and fix 75mm PVC (SWR) vent cowl complete all as specified and directed.
Supply and fix 110mm PVC (SWR) vent cowl complete all as specified and directed.
Material & labour for coloured ceramic non skid tiles 7 to 8mm thick, as approved, polished area of each tiles exc 0.11 Sqm but n.exc. 0.18 Sqm (square/ rectangular) as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed 15mm thick in cement mortar (1:4) complete including dismantling all as specified and directed.
M&L glazed ceramic coloured as required pattern tiles in 450 x 350 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4 and dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
M&L glazed ceramic coloured as required pattern tiles in 300 x 200 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:4 and dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
M/S A Q ENTERPRISES
M/S RAFIQ AHMAD SOFI AND SONS
M/S maqsood enterprises
M/S Rather and Sons
M/s Bashir Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .