Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L 1 | Accepted-AOC Being Lowest |
| 2 | L 2₹1.5 Cr+₹22.3 L (17.2%)Rejected-Finance | ₹1.5 Cr+₹22.3 L (17.2%) | L 2 | Rejected-Finance Being other then lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
23 Dec 2019, 6:00 pmClosed
CWE AF Srinagar
HQ CWE AF Srinager C/O 1 Wing Air Force Pin - 936801
PROVN OF GUARD ROOM AT 1 WING AF
2018_MES_193544_3
CWE(AF)SGR/SGR/T-10/2018-19
Open Tender
Civil Works
Lump-sum
540 days
AF Srinager
As per Tender documents
7 documents required · 7 mandatory
₹1,000
GE AF Srinager
₹2.5 L
Yes
17 Feb 2020
1 Nov 2019
26 Dec 2019
1 Nov 2019
23 Dec 2019
21 Nov 2019
Amount
Sch 'A' Part I (Building Work) Note: To be quoted by the contractor
Construction of guard room (double storey) complete all as specified and shown on drawings.
Construction of Parking for 20 scooters complete all as pecified and shown on drawings.
Construction of Garrage for 02 Gypsy complete all as pecified and shown on drawings.
SCHEDULE `A` PART-II TO PART XII (PREPRICED BY MES) Note:- These schedule are prepriced by MES and prepriced rate indicated under Col-5 bidders to quote there rate under Col-6 only
Sch 'A' Part II (Earthwork and excavation) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 20 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part III Section A (Internal Electrification) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 26 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part IV (Internal Water Supply) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 30 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part V (Sewage Disposal) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 34 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part VI (Road, Path & Culvert) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 38 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part VII (External Watersupply) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 42 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part VIII (External Electric Supply) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 46 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part IX (Refrigration & Airconditioning) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 48 and contractor has to quote the estimated amount under Col 6
Sch 'A' Part X (Demolition & Dismentling) Note: Prepriced at par with SSR 2010 Part II at Serial Page No 53 and contractor has to quote the estimated amount under Col 6
Sch `A` Part-XI (Misellaneous Items (B/R & E/M) Rate to be quated by tenderers. Note:- This schedule is not prepriced by MES and prepriced rate indicated as ``0.00`` under Col-5 signifies fact only
INTERNAL ELECTRIFICATION
S&F Decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate,enviromental friendly including energy efficient 4 feet LED tube rod, 1x18 w, 230v, , bipin holders, conector block, etc. complete with all accessories internally pre-wired and induding connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing of recess mounted LED fitting complete including LED lamp spiral (B22) 15 watt 240 volt.
Supply and fixing linear and compact 9W LED mirror light with decorative grey end caps, poly carbonate body and ribbed opal diffuser including 9W LED
Supply and fixing heavy duty exhaust fan,heavy duty,AC,single phase ,230/240 volt,50 cycles,900 rpm of size 300mm sweep M complete with louver shutters and connecting up with electric system and including provision of flexible copper 03 core PVC insulated flexible cord with stranded copper conductor of 1.0 Sqmm from ceiling rose to exhaust fan connector including grouting of holding down bolts in and including PCC(1:2:4) type B-1 blocks all as specified and directed.
Supply and fixing ceiling fan,heavy duty,AC,single phase ,230/240 volt,50 cycles, of size 1200mm sweep complete and connection with electric system and provision of 03 core PVC insulated flexible cord with stranded copper conductor of 1.0Sqmm from ceiling rose to fan complete all as specified.
Supply and fixing distribution board iron clad, double door with IP-43 1K -09 protection suitable for MCCB as incomer and MCB as outgoing 415 volts 3 phase 50 C/s 4 way, complete with appropriate size of copper bus bar and neutral link confirming to cat pt No. 607790 of Legrand or equivalent of make Hager/ Merlin Gerin complete with one MCCB 3 pole 415 volts 100 Amps rating with rupturing cap 16 KA of the same make as of distributon board and including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
S&F MCB ‘C' Series, single pole and nutral,240 Volts , 6 to 32 Amps all as specified and as directed by Engr- in -charge. Make: Havells Cat Part No. DHMCCSNF006-032 or equivalent in Legrand/ ABB/L&T
S&F MCB ‘C' Series singal pole 240 Volts , 6 to 32 Amps all as specified and as directed by Engr- in -charge Make: Havells Cat part No. DHMCCSPF006-032 or equivalent in Legrand/ABB/ L&T
Water heater storage type electrically operated suitable for 230 Volts, 50 Hz, AC supply system complete with porcelain/ glass coated insulated heating element, stainless steel tank, external thermostat and decorative plastic body, capacity 10 Ltr. Make :- Usha Lexus/Venus/Bajaj including 01 No CP connection for hot water and 01 No PVC connection for cold water complete all as specified and as directed.
ROAD/PATH AND HARDSTANDING
M&L for chequered cement concrete tile (reletive type coloured) 30cm x 30cm x 20mm thick set, jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including 15mm thick screed bed in CM 1:6, Make: Ultra/NITCO/NTC.
EXTERNAL WATER SUPPLY
M&L for cutting existing pipeline of size 80mm for making new conection by providing & insertion by new CI Tee equal/collar/bend/flange of appropirate size including all as required at site complete incl testing commissioning on completion.
Material and labour for valve pit of size 45x45x45 cm(internal dimensions of the chamber)including brick masonary with cement motor with 1:6,23 cm and flush pointing externaly work proceeds in the same motar complete with the the following specification and as directed by Engr-in-Charge. (i) 10mm thick plaster internally in CM 1:6 (ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard core of gauge not exc 63mm thick. (iii) Angle iron frame 40x40x6mm thick for cover and mild steel 3mm thick cover with locking arrangement ,handle and necessary hinges etc (iv) PCC 1:3:6 type C-2 100mm thick in foundation (v) Two coat of synthetic enamelled paint to cover internally and externally over a paint of Red oxide
EXTERNAL ELECTRIFICATION
Supply install, commissioning and testing LT panel Outdoor, cubical type, double door, floor mounted, made out of 3.0 mm thick MS sheet as outer cover and 2mm thick internal partitions duly powder coated complete with aluminium bus bar 400 amps rating mounted on epoxy based post insulators duly drilled holes for connections, with air vent made of 50 x 50 x 6 mm thick, angle iron frame all as specified including necessay foundation grouted in PCC 1:2:4 for mounting the panel suitable for 415 Volts, 50 C/s 3 phase and neutral system and ,internal wiring with suitable size of PVC insulated copper cable, copper lugs comprising of following accessories :-
Supply and fix Junction Box made of mild steel 1.6mm thick of size 250mm x 200mm x 150mm including 04 Nos aluminium bus bar of 2mm thick duly fitted on the suitable insulator with fixing arrangement and including SP MCB 6 Amps clamped with pole complete all as specified and directed by the Engineer-in-Charge.
M&L for two run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay aluminiumn conductor and drawn through pole from junction box to street light connection, complete all as specified and directed by Engr-in-Charge.
Cutting of road for passing cable through roads including re-surfacing of disturbed road surface with premixed carpet, WBM etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED Flood light 240W IP 65.Make Havells Cat part No.LHFPCZBFP46J240 or equivalent of Bajaj/Crompton
Supply and fixing Post Top Lantern LED 40W .Make Havells Cat part No.LHEVBGP7PN6K040 or equivalent of Bajaj/Crompton
AIR CONDITIONING
Voltage stabilizer for automatic operation ,single phase naturally air cooled indoor type and designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy of +/-2.5% and of capacity 5 KVA.
SEWAGE DISPOSAL
M&L for On site LLDPE conventional septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 20 users complet all as shown on drawing and directed.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 3.0 M effective depth effective depth complet all as shown on drawing and directed.
M/S MARVEL ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .