| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC SP 52 MPPGCL COLONY BIRSINGHPUR DISTT UMARIA 484 552 M P | BIRSINGHPUR | UMARIA | MADHYA PRADESH | 484552 | ₹1.3 Cr | L1 | Accepted-AOC AFTER SNAP BIDDEING ,L1 BIIDER |
| 2 | L2₹1.4 Cr+₹10.6 L (8.33%)Rejected-AOC C 85 SECTOR 63 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.4 Cr+₹10.6 L (8.33%) | L2 | Rejected-AOC AFTER SNAP BIDDEING ,L2 BIIDER |
| 3 | L3₹1.4 Cr+₹8.4 L (6.57%)Rejected-Finance | ₹1.4 Cr+₹8.4 L (6.57%) | L3 | Rejected-Finance ON DUE DATE OF SNAP BIDDING THE FIRM HAS NOT SUBMITE REVISED PRICE BID |
| 4 | L4₹1.5 Cr+₹18.4 L (14.4%)Rejected-Finance G 15 SHAHEEN BAGH KALINDI KUNJ ROAD NEW FRIENDS COLONY SOUTH DELHI DELHI 110025 INDIA | SOUTH EAST DELHI | DELHI | 110025 | ₹1.5 Cr+₹18.4 L (14.4%) | L4 | Rejected-Finance ON DUE DATE OF SNAP BIDDING THE FIRM HAS NOT SUBMITE REVISED PRICE BID |
Tender Value
₹1.4 Cr
EMD Value
₹2.5 L
Closing Date
12 Feb 2019, 5:30 pmClosed
SE PURCHASE AND WORK SSTPP DONGALIA
FLOOR 3RD ADMIN BUILDING SE PURCHASE AND WORK SSTPP DONGALIA
Annual Overhauling of Boiler Pressure part of unit 1and 2 at 2x600MW SSTPP MPPGCL Dongalia Distt Khandwa
2018_MPPGC_214_1
WT-742
Open Tender
Miscellaneous Works
Item Rate
60 days
SE PURCHASE AND WORK SSTPP DONGALIA
As per NIT
14 documents required · 14 mandatory
₹5,000
Payable To
₹2.5 L
Yes
27 Nov 2020
11 Jan 2019
16 Feb 2019
11 Jan 2019
12 Feb 2019
11 Jan 2019
SSTPP,Dongalia
COMPLETE EXTERNAL CLEANING OF BOILER FROM TOP TO BOTTOM.
INTERNAL CLEANING OF BOILER IN IInd PASS
CLEANING OF ASH FROM ECONOMISER HOPPER & DEAD CHAMBER
PREPARATION OF SCAFFOLDING IN BOILER HORIZONTAL PASS (SCREEN TUBES)
PREPERATION OF SCAFFOLDING ABOVE ECONOMISER HOPPER FOR INSPECTION OF ECONOMISER LOWER BANK COILS & C-HEADER.
PREPERATION OF QUICK ERECT SCAFFOLDING SYSTEM ( CUP-LOCKS SYSTEM) IN BOILER FURNACE.
PREPARATION OF SCAFFOLDING AT WW RING HEADER FOR INSPECTION OF RING HEADER & REFIXING/REPLACEMENT OF STRAINERS & ORIFICES
INSPECTION OF COMPLETE BOILER PRESSURE PART ( Ist & IInd PASS)
INSPECTION AND REPAIR OF All DOORS WINDOWS AND PEEP HOLES IN BOILER
Cleaning & REPAIR OF WIND BOX
SERVICING OF SECONDARY AIR DAMPERS
PREPARATION OF SCAFFOLDING IN CAT HOUSE FOR FRONT/REAR S-PANEL BACKSIDE CHECKING, REPAIRING
Dye Penetration Test (DP Test)
Transportation of Ash, Scraps, Debries and other waste materials ( including loading/unloading)
Preparation of Scaffolding for REPAIR AND RE-FIXING OF SEAL PLATES/COOLING PIPE OF WATER WALL S-PANEL AT TROUGH SEAL
SECTION-B
RECTIFICATION, REPLACEMENT AND REFIXING OF PROTECTION SLEEVE (SHIELDING) IN VARIOUS AREAS OF BOILER TUBES.
PREPARATION OF BOILER TUBE SURFACE FOR TUBE THICKNESS SURVEY
WELDING OF HP JOINT OF BOILER TUBES
WATER WALL TUBES- SCREEN TUBES, HANGER TUBES, REAR ARCH TUBES ETC.
LTSH TUBES
ECONOMISER SUPPORT TUBES
LTSH SUPPORT TUBES
SUPERHEATER STEAM COOLED SPACER TUBES
Reheater Front & Rear
Roof Tubes
REHEATER CROSS OVER TUBES
REHEATER STEAM COOLED TUBES
Lower /Upper Corner Transition Tubes
REPLACEMENT OF WW BURNER TUBES
ECONOMIZER TUBES
ALIGNMENT OF TUBES OF SH DIVISIONAL PANEL
ALIGNMENT OF TUBES OF PLATEN SUPER HEATERS
ALIGNMENT OF COILS OF ECONOMISER
ALIGNMENT OF LTSH COILS
ALIGNMENT OF REHEATER COIL
WELDING OF FINS
RE-ENFORCEMENT OF WELDED JOINTS
PAD WELDING OF BOILER TUBES AT VARIOUS LOCATIONS ( Size 50mm x 150mm)
INTERNAL INSPECTION & CLEANING OF BOILER DRUM
CHECKING AND RECTIFICATION OF SUPPORTS/HANGERS OF CRITICAL PIPE LINES
RECTIFICATION/REPLACEMENT OF EXPANSION INDICATOR IN BOILER AREA
APPLICATION OF REFRACTORY AT VARIOUS LOCATION OF BOILER (Gr.A+Gr.C)
BOTTOM ASH HOPPER-GR-C.
PENT HOUSE, DOOR & WINDOWS. ETC. -GR-C
MANHOLES PEEPHOLES GR-A
HYDRAULIC TEST OF BOILER PRESSURE PART& PREPARATION FOR BOILER LIGHT UP
SECTION-CCOMPLETE SERVICING/OVERHAULING OF HP VALVES
GLAND PACKING OF H.P.VALVES
Upto 25 mm
25 mm to 50 mm
50 mm to 100 mm
100 mm to 200 mm
Above 200 mm
COMPLETE SERVICING OF VALVES (EXCLUDING ACTUATOR):
Upto 25 mm
25 mm to 50 mm
50 mm to 100 mm
100 mm to 200 mm
Above 200 mm
REPLACEMENT OF VALVES (WELDED TYPE)
Upto 25 mm
25 mm to 50 mm
50 mm to 100 mm
SECTION-D
COMPLETE SERVICING OF SPRING LOADED SAFETY VALVES
BOILER DRUM SV
MAIN STEAM LINES SV
CRH LINES SV
HRH LINES SV
ELECTROMATIC RELIEF VALVE AND PILOT VALVE
SECTION-E
PREPARATION OF HP TUBE BENDS
REPAIR AND RE-FIXING OF SEAL PLATES/COOLING PIPE OF WATER WALL S-PANEL AT TROUGH SEAL.
REPAIR AND RE-FIXING/LAYING OF REFRACTORY ON COOLING PIPE OF BOTTOM ASH HOPPER.
REPAIR OF PENT HOUSE OF BOILER
REPAIRING OF DEAD CHAMBER
SECTION-F
ALIGNMENT OF WALLBLOWERS
ALIGNMENT OF LONG RETRACTABLE SOOT BLOWER
SERVICING OF WALL BLOWERS/LRSB
SECTION-G
APPLICATION OF THERMAL INSULATION
COMPLETE BOILER FROM BOTTOM ASH HOPPER TO PENT HOUSE
STEAM AND WATER PIPING
AIR HEATER & HOPPER
FUEL OIL AND ITS STEAM PIPING INCLUDING HEATERS FILTERS ETC.
SECTION-H
SERVICING OF MAIN SREAM STOP VALVE
SECTION-I
CLEANING OF EMEGENCY COOLING WATER SUPPLY TANK FOR BCW MOTOR
K K POWER CONSTRUCTION
Encotec Energy India Pvt Ltd
UNITED HITECH PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .