| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹18.3 L+₹1.3 L (7.96%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹18.9 L+₹2.0 L (11.8%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹19.7 L+₹2.8 L (16.4%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Feb 2022, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS AND MAINTAINANCE OF 0.6 MLD AND 0.2 MLD STP PLANT AT AUNDH MIL STATION UNDER GE MH AND RH KIRKEE
2022_MES_501536_1
8250/E8
Open Tender
Civil Works
Item Rate
330 days
KIRKEE AND AUNDH
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹50,000
Yes
8 Apr 2022
25 Jan 2022
24 Feb 2022
25 Jan 2022
22 Feb 2022
8 Feb 2022
25 Jan 2022 - 1 Feb 2022
Amount
Disconnection of electric connection taking out of submersible pump set 5 HP capacity complete from sump disconecting of pump for cleaning of blockage sludge servicing of pump , checking of all other parts for its serviceability after repairing , testing of pump entirly and lowering in existing position complete all as specified and directed .
All as per item no 1 above but 25 HP capacity sebmersible pump.
All as per item no 1 above but 30 HP capacity sebmersible pump.
Disconnection of electric connection taking out of Non clog vertical submersible pumps complete from sump disconecting of motor opening of motor removing sludges ,cleaning of slots including replacement of burnt copper winding with existiing size/ gauge and other spare parts such as oil seal,glands etc and after repairing , testing of pump set, lowering in existing position of Submersible pump 5 HP 3 phase 415 volt capacity complete all as specified and directed by Engineer-in- charge. :- .
All as per item No 4 above but Submersible pump 7.5 HP 3 phase 415V
All as per item No 4 above but Submersible pump 30 HP 3 phase 415V
Dismantling the coupling and taking out 7.5 HP pump ( make- Kirlosker) from pump motor set fixed in foundation and transport to work shop opening the pump, replacement unserviceable bearing and bushes and worn out nut and bolts gaskets, machining of shafts, over hauling & greasing of pump and reassembling packing gland with suitable size after fixing with motor , testing of motor and pump with full load at site complete all as specified and directed by Engineer-in- charge.
All as per item No 07 above 25 HP pump ( make- Kirlosker) .
Disconnectioning of electric connection and dismantling and taking out burnt electric motor from foundation for repair in local workshop ,opening of motor for rewinding wth super enamelled copper winding wire of suitable gauge as existing and varnishing, heating and testing after repair upto the entire satisfaction of Engr-in-Charge re-after repair reassembling and fixing it in its original location of 10 HP, 3 Phase, 440 Volt capcity complete all as specified and directed by Engineer-in- charge. (make- Kirlosker) :-
All as per item No 09 above but 25 HP, 3 Phase,440 Volt (make- Kirlosker).
M&L for replacement of submersible cable round/flat of 4 core 6 Sqmm with multistanded copper conductor inluding taking down complete all as specified and directed by Engineer-in- charge. .
M&L for replacement of submersible cable round/flat of 4 core 10 Sqmm with multistanded copper conductor Including taking down complete all as specified and directed by Engineer-in- charge.
M & L for servicing of compressor with air blower of 400 Cum/hr capacity unit replacement of compressor oil,air filter,r,oil filter,etc complete all as specified and directed by Engineer-in- charge. Model:EB6HPM
Supply and fixing in replacement fine bubble air diffuser type 63-1000 membrane OD 63 mm length 1000 mm air flow rate 7.0 – 10.0 m3/hr including taking down complete all as specified and directed by Engineer-in- charge.
Supply and fixing in repairs cast iron butterfly valves with SS. disc ‘ISI ’ marked lever operated PN-1.6 of 200 mm size including takingdown complete all as specified and directed by Engineer-in- charge.
All as per item No 15above but 150mm
All as per item No 15 above but 100mm
All as per item No 15 above but 80mm
All as per item No 15 above but 65mm
Supply and fix in repairs CI foot valve 100 mm dia ball type complete all as specified and directed by Engr- in -charge. Make: Normax / Upadhya
All as per item No 20 above but foot valve 80 mm dia.
Supply and fixing in repairs fan belt for compressor of size B-71 Make Ecodriver or equivalent complete all as specified and directed by Engr- in -charge.
Supply only MCCB 4 pole 415 V, Adjustable type 160 Amps, with breaking capacity 36 KA, complete all as specified and directed by Engr- in -charge
Supply only MCCB 3 pole 415 V, Adjustable type 100 Amps, with breaking capacity 25 KA, complete all as specified and directed by Engr- in -charge
Dismanling the UNSV pressure guage and S&F new pressure gause with pressure range 0-40 Kg/sq cm complete all as specified and directed by Engr- in -charge
Supply and Fix in replacement of CTs of 100/5 current rating AC, 415 V, three phase including connecting to supply as per existing all as directed by Engr-in-Charge.
S&F in repair power contactor 3 pole with AC coil 50 Amps along with aux contacts 2NO & 2 NC MO 50 make L& T /Siemens or equivelent complete all as specified and directed by Engr- in -charge.
All as per item No 27 above but 3TF33 with Aux contacts 01 NO & 1 NC .
All as per item No 27 above but 3TF30 with Aux contacts 01 NO & 1 NC .
All as per item No 27 above but 3TF35 with Aux contacts 01 NO & 1 NC .
S& F in repair themal over load relay range 6 to 10 Amps MN2 type make Siemens or equevelent make complete all as specified and directed by Engr- in -charge
All as per item No 31 above but MN2 with with relay range 20 to 33 Amps
All as per item No above 31 but MN5 with with relay range 30 to 50 Amps
S & F electronic timer for 3 phase starter of rating 20 to 33 Amps make- Siemens or equivelent approved make complete all as specified and directed by Engr- in -charge
S& F single phase preventor relay SPPR type Sz5(6 wire) 415 V 50 Hz Make Siemens or equevelent approvd make complete all as specified and directed by Engr- in -charge
S&F in repairs phase indicator lamp R.Y.B colour LED type complete all as specified and directed by Engr- in -charge
S&F in repairs voltmeter square dial of range 0-500 volt complete all as specified and directed by Engr- in -charge
Testing of treated water as per norms / standard raw sewage characteristics from Govt approved laboratory complete all as directed by Engr-in- charge. Note - Contractor shall collect water sample from treated water tank of STP twice in a month for testing of treated water from Govt approved agency and report shall be submitted to EIC
M& L in replacement of on load changeover switch of 100 Amps 4 pole open Execution type all as specified and directed by Engr in Charge (Make- Havells or equivelent make)
Preparation of painted surfaces of All STP such as various sizes valves/ wheels,railling , stair case and open pipes inlet/ out let etc. by means of wire brush /emery etc and cleaning and painting with one coat of Zink oxide and two coat epoxy paint of existing colour shades all as specified and directed.
All as per item No 40 above but activated carbon filter tank (02 nos ) with connected pipe lines and accessories.
All as per item No 40 above but Activated sand filter tank (01 nos ) with connected pipe lines and accessories.
All as per item No 40 above but Air Blowers (02 nos) with accessories and open pipes etc
All as per item No 40 above but chlorine contact water motor pumps 10 HP (02 nos)with accessories in and outlet open pipes
All as per item No 40 above but treated water discharge pressure pump 25 HP (02 nos) with accessories in and outlet open pipes
M&L Pebbles 25-40mm for change of filter media pressure type in the sand filter and activated carbon filter including opening and reassebling carefully up to entire satisfaction of Engr-in-charge
All as per item No 46 above but Pebbles 12-25mm
All as per item No 46 above but Pebbles 6-12mm
All as per item No 46 above but Pebbles 2-6mm
All as per item No 46 above but Activated carbon
All as per item No 46 above but Quartz sand 0.3 mm to 0.5 mm
Dewatering the water /sludge from tank by any means and clean the interior portion of tank(bottom and side of tank)by means of coir/wire brush etc and wash the enterior portion by using and clear away of all sludge,vegetation,muds to a distance not exc 50 m all as specified and directed for the Bar screen chamber tank of capacity 40 cum.
All as per item No 52 above but Raw sewage collection tank no-1 of capacity 200cum
All as per item No 52 above but Raw sewage collection tank no-1 of capacity 350 cum
All as per item No 52 above but Chlorine contact tank of capacity 200 cum
All as per item No 52 above but SBR tank of capacity 400 cum .
All as per item No 52 above but Fine filter tank of capacity 300 cum at STP
All as per item No 52 above but Sludge drying Bed of 50 cum capacity
All as per item No 52 above but Sludge tank of 200 cum capacity near Bldg No
All as per item No 52 above but Sludge tank of 300 cum capacity near QMTI sewage pumping installtion
Supply and lay in repairs M S Pipes B class heavy grade with all fittings,flange and nut bolts etc laid in floors or fixed to walls and ceilings etc of 65 mm dia.
All as per item No 61 above but Do but 80 mm dia
All as per item No 61 above but Do but 100 mm dia
All as per item No 61 above but Do but 150 mm dia
Supply and laying in replacement uPVC Pipe 10 Kg/Cm2 of size 40 mm outer dia,with"SEWAGE WATER " emboressed on it. including necessary fittings such as tees, bends elbows & reducer etc complete as specified directed Note :- Excavation and earth work shall be measured separately under respective items.
All as per item No 65 above but of size 63mm outer dia
All as per item No 65 above but of size 110 mm outer dia
All as per item No 65 above but of size 20 mm outer dia
Supply and laying in replacement 16 Sq mm 4 core XLPE armoured, LT 1100 V grade heavy duty with stranded aluminium conductor through pipes/road crossing, in ducts, on poles, trenches etc of all as specified and directed by Engineer in Charge. Note :- Excavation and earth work, sand cushion, brick cover and protection pipe shall be measured separately under respective items.
Supply and laying in replacement XLPE insulated copper power cables armoured of size 6 sq mm 3 core 650/1100 Volts Grade confirming to IS : 7098 (Pt-1) 1988, through pipes / cable duct all as directed.
Excavation in trenches not exc.1.5 m wide and not exc 1.5 m depth (for taking out and laying of water pipe line and getting out in soft/loose soil complete all as specified and directed.
Returning filling in trenches including spreading ,levelling,watering and well ramming in layers not exc 25 cm complete all as directed.
Removing of excavated material not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed
M & L for Bar screen chamber complete all as specified and directed by Engineer in Charge.
M & L for attending breakdown of UPVC pipe line Dia 63MM with replacing the broken pipe by one metre new pipe including cutting ,removing broken pipe, fixing new, dewatering ,excavation refillling and removing all included as one job
M & L for EPDM size 63MM Dia, pipe pressur 17kg/Squre CM with replacing the broken pipe ,removing broken pipe, fixing new, dewatering ,excavation refillling and removing all included as one job
M & L for Rotomter fixed at compressor pipe line dia 150 mm dia incl taking down complete all as specified and directed all included as one job
M & L for mobile lifting chain (1 ton capacity) fixted at existing submersible pump incl taking down u/s complete all as specified and directed by Engr in Charge all included as one job
M & L for Surface dressing n exc 15 cm deep in soft/loose soil at pump house ph - I & II area complete all as specified and directed by Engineer in Charge.
supply and fixing by Taking old unservicable fully automatic star delta starter cap upto 7.5 HP to operate motor working on 380-440 volts, 3phase, 50 HZ with no volt coil, over load element, and ON -OFF push buttton, with nessary material and connectd to supply etc. suitable for fixing in the existing panel/location complete all as specified and as directed.
supply and fixing by Taking old unservicable fully automatic star delta starter cap upto 7.5 HP to 30 HP to operate motor working on 380-440 volts, 3phase, 50 HZ with no volt coil, over load element, and ON -OFF push buttton, with nessary material and connectd to supply etc. suitable for fixing in the existing panel/locationcomplete starter with original sheet encloser all as specified and as directed.
supply and fixing by Taking old unservicable DOL starter cap upto 7.5 HP to 30 HP to operate motor working on 380-440 volts, 3phase, 50 HZ with no volt coil, over load element, and ON -OFF push buttton, with nessary material and connectd to supply etc. complete starter with original sheet encloser all as specified and as directed.
Decorbonising of Auto Panel / LT indoor/outdoor Panels/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, Cleaning of dust with air blower, burnt busbar, burnt timmbles, any type of insulators, cable tray, spiral piping , necessary cable tie, reconnection after proper cleaning of contracts with CRC solution and painting of complete panels including stand and door/back outside ( after proper scrubbing) with systhetic enamel paint one coat as per specified colour code including writing of panel/feeder panel location using black systhetic paint and reconnecting the dismantled LT cables etc. completet all as specified and as directed by Engr- in - charge. Note: (i) Cost of labour, cotton waste and T & P required for upkeeping/maint work is inclusive in quoted rate.
M & L for fiterpress of size 610 mm x 610 mm x 13 plates including suitable foundation as per the OEM recommendation, connecting the inlet and drain pipes complete all as specified and as directed by Engr in Charge.
Dheer Engineering
Aquatech Engineers
SKS Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .