| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹35.9 L+₹2.5 L (7.49%)Rejected-AOC 0 BUDKIYA DEVATRA JODHPUR RAJASTHAN 342606 | JODHPUR | RAJASTHAN | 342606 | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹36.1 L+₹2.7 L (8.04%)Rejected-AOC H NO 920 SEC 16 17 HISAR HARYANA 125005 | HISAR | HISAR | HARYANA | 125005 | L3 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹37.3 L
EMD Value
₹74,500
Closing Date
15 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
CA No GE(H)-06/2021-22
2021_MES_446458_1
CA No GE(H)-06/2021-22
Open Tender
Civil Works
Item Rate
210 days
Hisar Mil Stn
As per Tender documents
7 documents required · 7 mandatory
₹500
GE Hisar
₹74,500
Yes
9 Aug 2021
28 May 2021
17 Jul 2021
28 May 2021
15 Jul 2021
12 Jun 2021
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
Demolition of cement concrete reinforced Roofs, floors other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layer on roofs including demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for in this Schedule all as specified & directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed .
Taking down chowkat or frame with shutters area not exc 1.5 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M&L for PCC 1:3:6 type C0, using 12.5mm graded crushed stone aggregate as in filling up chowkat hollows and similar works as directed, complete, all as specified.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Supply only water proofing compound (ISI marked).
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete all as specified.
M&L formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete all as specified and directed.
M&L formwork to edges of concrete flats, roofs, floors etc not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces all as specified and directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L brick work with subclass 'B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
Providing and erecting steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till req uired and as directed. Note : (i) Hydraulic & manual steel props will be provided, erected and maintain the interval distance of steel props c/c at site on the basis of site requirement as per direction of Engr-in-Charge. (ii) For measurement purose soffit area of beam, slab, wall or column shall be measured for each storey seperately. (iii) This item is required to be operated for structural rehabiliation related items mentioned here-in-after.
Chipping of loose/ damaged / cracked / previously repaired/ delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 30mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using Product : Rustoff-100 of Sika or equivalent make in Fosroc / Thermax as approved by GE, with density : 1.01 Kg/ltr at 30°C and consumption : 0.2 kg/Sqm/coat complete all as specified and directed. Note : (i) The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. (ii) For measurement purpose area of application will be measured as length of bar x two times the dia of bar.
Supply and apply cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and product requirements: carbonation resistance : 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N/Sqmm according to ASTM C 882-78 complete all as specified and directed. Note : (i) The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. (ii) For measurement purpose area of application will be measured as length of bar x two times the dia of bar.
M&L for Providing, fixing shear connector of 16 mm dia TOR steel upto 160 mm length with Sika anchorfix @ -3+ Mungo / Fischer FISV 390 / Hilti RE 500 Epoxy resin or equivalent make in Fosroc / Thermax as approved by GE, to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer’s instructions complete all as specified and directed.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer’s specification including prepartaion of surface thoroughly and cleaning complete whereever required with using Product : Sikadur®-32 LP of Sika / Master Brace1441 or equivalent in Fosroc / Thermax as approved by GE with consumption : 0.4 kg/Sqm and Product requirements : Comp with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement and directions of Engineer-in-charge
Supply and apply a ready to use non shrink, cementitious free flow micro concrete (<100 mm) using Product : SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
Supply and apply a epoxy resin based solvent free bond coat, Produxt Sika/BASF/Fosroc, consumption 0.40 Kg Sqm, Product requirement Complies with ASTM C 881 Type II Grade 2 Class B+C.
Supply and apply a pre-batched one component polymer modified cementitious patch repair moratr for a thickness of 40mm or as directed by Engineer-in-charge, Product Sika / BASF / Fosroc, Yield approx 0.84 Litre/Kg, System requirement - compressive strength >= 50 N/Sqmm (28 days) according to ASTM C 109, Flexural strength >= 3N/Sqmm (7 days) according to ASTM C 293-79.
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & directed.
S&F factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
S&F for factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S & F Factory Made Solid PVC Moulded Door Shutter (with particle board), 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified & directed.
S&F stainless steel butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S & F 150mm long extruded aluminium alloy handles, fabricated type, anodised (ISI marked) complete all as specified.
S & F 200mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified.
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, mild steel sheet of 1.25 mm thickness complete as specified & as directed. Note :- Rates quoted deemed to include S&F of hinges, lugs, lock strike plate.
S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, mild steel sheet of 1.25 mm thickness complete as specified & as directed. Note :- Rates quoted deemed to include S&F of hinges, lugs, lock strike plate.
S&F wire netting of stainless steel wire 1.23mm dia fixed with tinned tacks of stainless steel wire staples (size of mesh 12mm) to fix with steel / wooden frame complete all as specified.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including box type hinges with steel handle etc complete with glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including making good disturbed surfaces of walls, complete. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including box type hinges with steel handle etc complete without glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including making good disturbed surfaces of walls, complete. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made steel ventilator, ISI marked (box type) with top hung shutter steel peg stay, including one shop coat of Zinc chrome primer including making good disturbed surfaces of walls, complete. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel ventilator. Nothing shall extra paid on this account. (ii) Details of box type ventilator shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3. (iii) Glass pane/wire gauze shall be measured and paid separately.
M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
All as per serial item No. 48.00 here-in-before but 5 to 10mm dia in stirrups, spacers and binders.
All as per serial item No. 48.00 here-in-before but 6mm to 8mm dia.
S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified & as directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cooler stand and similar work including welding conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
M&L for preparation of RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles. Filling the cracks by crack filler Providing 50mm thick average thickness (Thickness of PCC 70mm at centre and 30mm at outer edge of roof surface) PCC 1:2:4 type B1 (using 20mm graded stone aggregate) at the places where slope is not proper or roof surface is uneven to maintain the proper roof slope complete all as directed.
M&L for Providing 10mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30%) over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm and applying 2nd coat solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Note :- The work of WPT shall be got executed through authorised approved applicator. Make :- Asian Paint / Pidilite / STP.
M&L for 50mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in levelling course 25mm thick finished fair & even complete all as specified & as directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site.
M&L machine cut Kota stone slab 15 to 20mm thick , as in skirting etc. laid over & including screed bed or bedding layer of 10mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
M&L for non skid ceramic jointless tiles (coloured), 1st quality, 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic jointless tiles (coloured), 1st quality, 7 to 8mm thick, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for non skid ceramic jointless tiles (coloured), 1st quality, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M & L for glazed ceramic jointless tiles (coloured), 1st quality, desinger & pattern (dark & light combination) 300x450x7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L rendering 20mm thick in cement mortar 1:3 in two layers on concrete surfaces in ceiling, including fixing of chicken mesh of suitable size, surface finished even & smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement mixed with water proofing compound as per manufacturer’s instructions, all as directed. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for preparation of old plastered or unplastered surfaces of walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and applying two coats of white wash complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of walls & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint on walls all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of oil bound distemper of approved shade/tint over a coat of primer on walls all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
Material and labour for preparation of new steel surfaces (already applied with coat of primer) of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint of approved tint on existing primer complete all as specified.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads in square not exc 0.5 sqm in each pane and fixed with putty or beads complete all as specified and directed.
S&F in repairs 3mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified.
Dismantling old unserviceable PVC water tank capacity exc 250 ltr and not exc 500 ltrs & removal from site etc complete all as specified and directed.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified and directed.
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
S&F in repairs 15mm bore angle valve, chromium plated, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
Supply only 15mm bore fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes & fly nuts, screwed for iron pipes all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints including 195mm long brass chromium plated arm with bend 45 degree etc complete all as specified and directed.
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&Fin repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe 90cm long and 32mm bore PTMT waste coupling with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified. Note :- Supply only pillar tap shall be measured & paid seperately under relevant item of BoQ.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. (measured overall as fixed along the centre line over fitting and accessories) complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls with fittings complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls with fittings complete all as specified.
S&F 110mm bore PVC (SWR) bend any radius all as specified & as directed.
S&F 100mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 75mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified.
S&F in repairs single/multi PVC (SWR) floor trap dia of outlet 75mm, with PTMT grating including jointing with solvent cement fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate etc complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No. 106.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 106.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per srl item No. 106.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F LED bulb of capacity 15 W, ISI marked, all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F LED light fitting 1x18W/20W/22W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT8UPTO1X22WSSBSWH & LED tube rod Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or Surya Cat Part No SLE BT 20 MS for batten & LED tube rod Cat Part No SLE TL-DS 18 PC Reform of Surya or Cat No LTTB4F20WLEDEW BATTEN for batten & LED tube rod Cat No Cat No LT4F20WLEDT8/WDI of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement street light LED light fitting 18/20 Watt, pressure die cast housing with epoxy powder coating, IP65, connected with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. Make : Cat Part No ENDURAPEARLSL20WLED757SASYTOPCMP of Havells, Cat No SSK-SLF-CF-18W of Syska, Cat No LTESSI20WLED of C&S or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, TPN with 200 Amps rated bus bar, 4 way, 240 Volts. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F MCB SPN, 40 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 240 Volts , type 'C' curve, 16 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
Supply and fixing one star rated energy saving ceiling fan 1200mm sweep as per alest IS-374-2019 having service value > 4 to < 4.5 m3/min/w and 50 watt with double ball bearing and three blades with all accessories, down rod, two nos canopy, white in colour including 2 core 0.5 sqmm copper flexible cable for connection from ceiling rose to fan complete all as specified and directed.
Supply & fixing and testing metal body exhaust fan of 450mm sweep heavy duty, double ball bearing, 900 RPM, suitable for SP 230 / 250 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in wall & cutting opening complete with covers & connecting with & including 3 Nos 1.5 sqmm single core, PVC insulated but unsheathed FRLS 1100 volts grade cable with multi-stranded copper conductor from ceiling rose to fan complete. Make : Model No Turbojet SP of Havells or Cat Part No Supreme DLX HD of Bajaj or Cat No Transair of Crompton equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
Supply and fixing in replacement LED downlight of 18W capacity, having polycarbonate frame & super bright LEDs, suitable for fixing on rood with fastner etc complete, all as specified & as directed. Make :- Cat Part No EDGEPRORDDLR18WLED840S of Havells or Cat Part No HLDLS-S06-18W-CW of Halonix or equivalent of make mentioned in Appx 'C' here-in-after.
Supply and fixing post top LED lantern of capacity 35 Watt alongwith 80mm dia GI pipe medium garde 1.50m height (1.20 above GL and 0.30m below GL embedded in PCC) alongwith all accessories for fixing the post top lantern including necessary excavation & earthwork of post hole of size 40cmx40cmx40cm for fixing GI pipe in ground and PCC 1:2:4 type B1 using 20mm garded stone aggregate complete, all as specified & as directed. Make :- Cat Part No VICTORIAPT35WLED73OPSYMTOTG of Havells or equivalent of make mentioned in Appx 'C' here-in-after. Note :- The quoted rates deemed include cost of excavation & earthwork, PCC, GI pipe for fixing the Post top lantern.
Supply and laying or fixing or passing through pipe,in replacement 10 sqmm 2 core, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed as in service connections all as specified & directed.
Supply , laying , jointing, testing and commissioning of cable of size 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors as per IS 7098 (Part-I), laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe including taking out existing u/s cable complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness afterlaying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
S&F Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall.
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
OM CONSTRUCTION CO.
SHRI HARI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .