| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹40.4 L+₹68,651 (1.73%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹42.2 L+₹2.5 L (6.30%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹42.8 L+₹3.1 L (7.68%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43.8 L
EMD Value
₹87,600
Closing Date
3 Jan 2022, 6:00 pmClosed
GE (AF) KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
PROVISION OF FLOOR TILING AT 4AFH, REPLASTERING AND ROOF TREATMENT BUILDING NO.P-1, P-2 AND P-3 AT 4AFH AND CERTAIN MAJOR REVENUE WORK AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2021_MES_492282_1
8711/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) KALAIKUNDA
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) KALAIKUNDA
₹87,600
Yes
9 Apr 2022
3 Dec 2021
5 Jan 2022
3 Dec 2021
3 Jan 2022
22 Dec 2021
Amount
Demolition of lime concrete of any description and in any position not otherwise specifically provided for including taking out of old damaged unserviceable tarfelt or membrane of any description and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
Taking out of old unserviceable/damage tarfelt of any description and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc. complete to receive for roof treatment complete all as specified and as directed.
Dismantling water tanks capacity exceeding 250litres but not exceeding 1000 Litres and removing to store complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified
Roughening surfaces of old concrete as in roof /floorby picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg per sqm finished fair and smooth complete all as specified & as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking down SWR pipes (any size or pattern), including all fittings, 'T', bends,etc., including removal to store for taking credit (measured overall as fixed along the centre line over fittings and accessories), complete all as directed.
Removing plants including roots by dismantling of brickwork/PCC including necessary scaffolding of any type and in any position or location i.e roof , parapet walls near pipes etc and applying acid after removing roots for preventing the re-growth & making good of disturbed portion using PCC 1:2:4 type B0 & 10mm thick cement plaster in CM(1:3), size of disturbed portion not execeeding 150mm X150mm X 200mm complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
Supply only Liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed (Make : CICO No- 1/SIKA/ACCO PROOF).
Materials and Labour for brick work with fly ash Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), complete all as specified and directed.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1), by weight complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment/ specifications from bottom to top:- (a) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384. (b) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. NOTE :- (i) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (ii) Side overlaps shall be minimum 75 mm and the end taps shall be minimum 100 mm and sealing of all overlaps & joints as per manufacturer instruction. (iii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing. Make of APP Membrane : M/s STP Ltd./M/s Texsa India Ltd./M/s IWL India Ltd. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervision. Requisite guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate. (iv) Curing of slab with ponding test with water shall be done all as directed by engineer-in-charge for 72 hrs and payment will be allowed after satisfactory leak proof test report. (v) The period of guarantee for the roof treatment shall be 8(Eight) years from the certified date of completion and Condition 46 of the GCC(IAFW-2249) shall be deemed to be amended to the extent mentioned above (vi) Entire operation shall be done by the approved manufacturer or their authorized applicator and other materials required under instructions of manufacturer deemed to be included in the unit rate.
M&L for applying two coats of aluminium paints on top of APP membranes @0.125kg/sqm after complete laying of APP based polymeric membrane through authorised applicator complete all as specified & as directed.
M&L for cement concrete type B-0, 1:2:4 using 12.5 mm graded aggregate as in roof padding in order to maintain proper slope and camber finished the surface to receive screed bed or bedding complete all as specified & as directed.
M&L for cement concrete 25 mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) as in base of flooring, finished even and rough to receive the top layers all complete as specified and as directed
Material and Labour for Digital Vitrified Ceramic Tiles, , 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, conforming to IS 15622, Grade B II on floors, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6), complete all as specified and directed.MAKE:- (Johnson/Kajaria or equivalent make )
Materials and Labour for, Digital Vitrified Ceramic Tiles, , 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, conforming to IS 15622, Grade B II, on vertical surfaces of wall such as dados, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.MAKE:- (Johnson/Kajaria or equivalent make )
M&L for screed bed or bedding layer of cement mortar (1:4) mixed with liquid water proofing compound as per manufacturer instructions 10 mm thick on roof surface for maintained proper slope to receive priming coat for roof treatment all as specified and as directed.Note: - (Water proofing compound will be measured and paid separately)
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
M&L for rendering 5mm thick cement plaster CM 1:3 as ceiling/chajja on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete ll as specified and directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered or un -plastered from walls, and applying two coats acrylic distemper on walls, over and including a coat of primer complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches, wall and floor including all fitting complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F rotational moulded polyethylene multi layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including 20mm brass float valve high pressure complete all as specified and as directed.
S & F rotational moulded polyethylene multi layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
M&L for disconnecting existing tank setting aside for repairs, cleaning and removing all scales, dirt etc from tanks and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc. 250 and not exc. 500 ltrs complete all as specified & as directed.
M&L for disconnecting existing tank setting aside for repairs, cleaning and removing all scales, dirt etc from tanks and mouth of circulating pipes and hoisting, reconnecting and refixing in position capacity exc.500 and not exc. 1000 ltrs complete all as specified & as directed.
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S & F in repair 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 15 mm bore all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing of old steel tubing and connection with new fittings ISI Marked in new or old position (wall, ceiling, floors, etc) of 20 mm bore all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply & Fixing Flexible heavy duty PVC / delivery hose pipe, sprial ribbed, green colour , working pressure 3.5 Kg / Sq cm of nominal bore 150 mm cut to length as required at site including clamp, nut bolts and fixing arrangement complete all as specified and directed by EIC. Make : Kisan / Supreme/
Supply & fixing of Submersible Cable 6 Sqmm 3 core flat cable copper conductor, ISI marked , conf to IS complete all as specified and directed by Engineer-in-Charge. Make : L&T/ Havells /Finolex
Supply and fixing Steel wire rope PVC coated of 10 Sqmm, ISI marked, round rope, including U clamp and nut bolts, cut to length as required and tide to hold submersible pump in bore well and sewage pump in sewage sumps complete as specified and directed by EIC
Supply and fixing stainless steel wire rope clamp grip for rope clamping 'U' with nut bolts washer etc all as specified and directed by Engineer -in-charge
S & F GI reducer socket of size 150 mm x 100 mm dia complete all as directed and specified by EIC.
Supply & fixing AC Direct connected Electronic Static Single Phase Keypad Prepaid energy meter (kWH meter) with Customer Interface Unit (Home Display Unit) Single source of current range 5-60A, 240V, 50 Hz including enclosures box, Meter confirming to IS-13779 and IS-15884, IEC 62055-31 with bluetooh freedom, 1107 PORT, MS Cage Clamp, IP 53, overload capacity 120% of I basic , Accuracy Class 1, with split unit, Provision for TOD (Time of day) Tariff and RTC (Real Time Clock), current rating of terminal 120% of Imax, LCD display graphical with green backlight color, kWH Led encrypted STS based token system, capable of measuring total energy (fundamental energy + Harmonics) with temper proof Polycarbonate transparent cover (Hinge Box) including 1.50 sqmm/2.5 sqmm copper FRLSH wiring (Phase+Neutral) from meter box to Distribution board, installation of meter on laminated board, inlcuding vending charge for lifetime and warranty for 10 years in written as declared by manufacturer and complete all as specified and directed including dismatling of Old conventional meter and deposting to AGE E/M (AF) KKD (MES Store). Make - Secure Meters Ltd. Model - Liberty 150/ L&T/HPL or equivalent make as catered in PS
SUMAN CONSTRUCTION
Guru Charan Mahata
SHARMA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .