Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.9 Cr
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Internal and External Electrification and allied works for I.T Innovation Park at main campus university of Kashmir
2022_UDJK_169593_1
F(E.Tend)(UCD)/KU/11/22
Open Tender
Electrical Works
Item Rate
365 days
Main Campus
As per NIT
3 documents required · 3 mandatory
₹2,600
Registrar University of Kashmir
Exempted
2 Jun 2022
18 May 2022
2 Jun 2022
18 May 2022
1 Jun 2022
18 May 2022
120 days
Amount
"Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,space heater, power outlet, illumination lamp, Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enameled painted and having following incoming and outgoing MCCBcomplete as required. Note:-Internal control wiring for capacitor bank with main LT Panel to be in the scope of panel builder. " MLTP PANEL INCOMER: 1nos. 630A 4P microprocessor based MCCB of 36kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. 1 nos. Digital type multifunction meter and indicators 2 Set of R,Y,B LED phase indicating lamp with MCB protection. 1 Set of ON,OFF & TRIP LED indicating lamp with MCB protection. BUSBARS: 630 Amp TPN (25kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminium shall not be more than 0.8 Amps/ sq.mm. OUTGOING: 3 nos. 200A 4P thermal magnetic based MCCB of 25kA adjustable. (AC/heating) 1 nos. 400A 4P thermal magenetic based MCCB of 25kA adjustable.(servo) 2 nos. 125A 4P thermal magnetic based MCCB of 25kA adjustable.(tress pump) 1 no. 100A 4P thermal magnetic based MCCB of 25kA adjustable (out door applications) Digital Multifunction Metern, with suitable rating Class-I CT's for outgoing feeders . For all out goings ON/OFF LED indicating lamp with MCB protection. BUSBAR All OUTGOINGS should have suitable bus links for mutiple terminations MLTP PANEL described above and specifications complete. The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit his test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears
SUB DISTRIBUTION BOARD Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed In doortype, free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enamelled painted and having following incoming and outgoing MCCB ,MCB's meters , ATS complete as required. 2 No. 250 Amp TPN MCCB thermo magnitic of 36kA . (DG and Mains) 6 nos. 160A TPN MCCB thermo magnitic of 25kA with MCCB of 25kA with Rotary Handle, adjustable. 6nos. 125A TPN MCCB thermo magnitic 25kA with Adjustable . meters with of CT's R,Y,B LED phase indicating lamp with MCB protection. BUSBARS 4 pole suitable for each sagment. space for additional MCB TPNs Note; The contractor will have to submit ISO certification and internal Drawings. The Contractor will have to submit his test certificates i.e (HV test 1.5KV for 1 Minute , Megger Test) Manufacturers Test Certificate of Main Switchgears
Supplying and fixing following way, Vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ MCCB/RCCB/Isolator) with three phase and single with out . (AC SDB, UPS SDB and light SDB ) 4+24 way
Providing, fixing, testing and Commissioning of DP32A RCCB 100-300mA including Double door enclosure suitable for RCCB as per requirement
Supply, laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade.
35 sqmm 3 1/2 core
50 sqmm 3 1/2 core
70 sqmm 3 1/2 core
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade.
185 sqmm 3 1/2 core
300 sq mm 3 1/2 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed
3½ X 35 sq. mm (32mm)
3½ X 50 sq. mm
3½ X 70 sq. mm
3½ X 185 sq. mm
3½ X 300 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 185 sq. mm and upto 300 sq. mm
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 150 mm dia
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links. 160 Amp 25KA 4 pole
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links . 125 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 - 160 Amp 4 P MCCB
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supplying and fixing 0.5 A to 4 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Double pole
Supplying and fixing following rating, TPN, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required with Double door enclosure 40-63 A
Providing and fixing of 8 way Double door distribution Board (EDB)
Providing and fixing of 16 way Double door distribution Board (LDB)
Providing and fixing of 18 way Double door distribution Board (PDB and UDB)
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required including cutting the wall and making good the same Note : Rates of Suitable PVC conduit included in above description for the follwing items
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (E)
2 x 4 sq.mm + 1 x 4 sq.mm earth wire (L)
2 x 6 sq.mm + 1 x 6 sq.mm earth wire
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring (UPS to UDB)
4 x 6 sq.mm + 2 x 6 sq.mm earth wire for Sub main wiring
4 x 10 sq.mm + 2 x 10 sq.mm earth wire for Sub main wiring
2 x 16 sq.mm + 1 x 16 sq.mm earth wire for Sub main wiring (submain panel)
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring to AC vtpn)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects note: all items included like Conduit, wire, MS box, switches,including cutting the wall and making good the same etc.
Providing and fixing of Lighting point in loop wiring with 1.5 mm2 PVC insulated copper wire of FRLS through heavy duty PVC conduit pipe with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular switches, plate & MS box of required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, MS junction box, wire, box, switches,including cutting the wall and making good the same etc.
Providing and fixing of fan/ light point wiring with 1.5 sq. mm PVC insulated copper wire of FRLS through heavy duty PVC conduit with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular plate & MS boxof required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, Junction box, wire, box, switches etc.
Providing and fixing of UPS point (in loop max 4 pts.) with 1.5 sq. mm PVC insulated copper wire , through PVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 1 nos. recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 1.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned note: all items included like Conduit, wire, box, switches,including cutting the wall and making good the same etc.
Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire through 1 inch heavy duty PVC conduit pipe and providing and fixing of 32 Amp Dp MCB 10KA C curve with enclosure including providing and fixing of 6 sq. mm PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned in all respects complete. note: all items included like Conduit, wire, box, switches,including cutting the wall and making good the same etc.
Providing and fixing of 4 ft LED slim 16 watt 110lm/w 230V Batten type lights(T5), complete in all respects. With 2kv surge protection. Industrial
Providing and fixing of 15 surface LED slim 230V , complete in all respects. With 2kv surge protection.
Providing and fixing of 12 Watt surface/ recess mount 230V , complete in all respects. surge protection
Providing and fixing of 12”x12” Metalic type exhaust fan complete with all accessories includindg Frame etc .
Providing and fixing of 48 inches Sweep energy efficient ceiling fan of approved sample at site including wiring the down rods of standard length (30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc including Fan Junction MS box as required.
Providing and fixing of Fan dimmer electronic regulator Including MS box and Modular Plate 5Ampere 3 pin type.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required. TV antenna socket outlet
20/25 A switch
6 pin 20/25 A socket outlet
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) for net port
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in heavy duty PVC conduit (conduit included) as required. 1 run of cable
Supply and installation of flush mounted Enhanced Category 6 outlet. The plastic shall be high impact, flame-retardant, UL rate thermoplastic. Dust cover / blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover shall be provided to protect jack wiring. D-link Single outlet faceplate with RJ-45 jack
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the heavy duty PVC conduit as required cost of conduit included
Supplying and fixing in position the following sizes of powder coated MS housing for telephone tag block with hinged & lockable door including supply & fixing of tag block made out from self extinguishing polystrene material, corrosion resistant, highly resistant to shock, strudy and maintenance free KRONE type telephone tag block complete as required. 20Pair
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections and modular plate etc. as required Telephone socket outlet
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / DBs etc.
Providing and fixing of GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required.
Providing and fixing of lighning conductor finial, made of 25 mm dia. 300mm. Long GI tube, having single prone at top, with 85mm. Dia. 6mm thick GI base plate including holes etc. complete as required.
Providing, fixing and Cladding with 3 mm thick matt finish Aluminium composite panel with all fixing arrangements to cover the pipe line/ finishing etc.
Providing and fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)
Providing and fixing of 4.5kg. capacity I.S.I. Marked. (IS : 15683) Carbon-di-oxide fire extinguishers consisting of welded M.S cylinderical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long ISI marked high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge.
PORTABLE FIRE EXTINGUISHERS 'Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity
Supplying, fixing of Automatic fire fighting ball “TECHIDEAS” ELIDE FIRE or equivalent ABC type extinguishing ball, automatic fire extinguishing technology. AUTOMATIC fire fighting ball Size (Diameter.) 6 inches. or 152 mm. (ELB01) WEIGHT (Kg.) 1.3 Kg. +/- 0.2 Kg. COVERAGE AREA 4 sq. meter radius 360 degree Installation ambient temperature -40 C° up to +85 C° Service life of automatic fire surveillance (years) 5 years Operating time (sec.) 3-5 seconds Operating temperature 280 C° or touching the flame etc. including Providing, fixing of suitable holding stand for same
Supplying,Fixing, Testing and Commissioning of outdoor LED street light luminaries flood lights 120 Watt. Reputed make as per approval of engineering wing.
FIRE ALARM SYSTEM Supplying and fixing of following sizes of heavyduty class conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. 2 core 1.5 sq. Mm
Supply, installation, testing and commissioning of UL listed multi LooP (not less than 255 modules aceptance/ L)Addressable fire Alarm Control panel complete with 960 character Liquid Crystal Display,with sufficient panel enclosure and cabinet size.The panel shall be able to give location of all fire/fault condition of addressable units via the address codes. Further,the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output,external/inbuilt printer to Log all fire or fault events complete in all respects.The panel shall have a built in Power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 8 hours with battery charger complete as required.panel shall be able to sense & indicate fire or fault.
(MR) Supply,installation ,testing and commissioning of UL listed intelligent Addressable Multi Criteria Smoke cum Heat Detector ,optical type with blinking LED and being capable of being addressed electronically .Manual Addressing (Dip/Rotary Switches) not acceptable,with Mounting Base.
(MR) Supply,installation ,testing and commissioning of UL listed intelligent Addressable Double action manual pull station capable of being addressed electronically.Manual Addressing ((Dip/Rotary Switches) not acceptable,complete as required.
Supply, installation, testing and commissioning of UL listed Fire Alarm Hooter (sound output of minimum 90 dB upto a distance of 30 meters) ,made Addressable with the help of intelligent Addressable Signal Module,capable of being addressed electronically .Manual Addressing (Dip/Rotary Switches) not acceptable , with seperate power supply arrangement complete as required and suitable for wall/ceiling mounting.
Supply,installation ,testing and commissioning of UL listed Addressable Fault isolator module complete as required for determining the short in a circuit and separating the segment having the short capable of being addressed electronically .Manual Addressing (Dip/Rotary Switches) not acceptable ,Complete as required.
Supply,installation ,testing and commissioning of UL listed Addressable control Module complete as required for driving hooters capable of being addressed electronically .Manual Addressing (DIP/ Rotary/Switches) not acceptable
supplying and fixing of LED type Response indicator having at least 2 nos. Coloured LED lamps including connections etc. Complete as per specifications
supplying and fixing of MS deep junction boxes in slab for detectors
Supply, installation, testing and commissioning of Control Module complete as required for driving hooters, capable of being addressed electronically. Manual Addressing (Dip/ Rotary Switches) not acceptable.
"Design , Supply , Installation , Testing and Commissioning of Passenger Elevator including system control panel and with following specifications including all necessary Chanelles/Gauders and all other accessories complete, should have following technical parameters: Note: Free maintenance for twelve months. The period of this maintenance shall commence from the date of handing over of the lift. " Capacity / Load:8 Persons (Gear Less MRL) Speed: 1 MPS Type of drive: VF Regenerative (closed loop) Rise (m): as required. Serving: GF , 1st , 2nd, 3rd & 4th Stops: 5 Controller type: ACD3-MRL/eq. Power Supply: 400/415 Volts 3Phase Operation: Full collective Car group: One car (simplex) Machine: PM Gearless ( located in Shaft on top of guide rails) Ventillation: Cross flow fans No. of Car entrance: One location front at all floors Hoistway/ Car entrance door: Centre opening, Glass , SS Hairline finish Traction Media: Flate Coated steel Belt Operation: Automatic Control: Simplex False ceiling Type: CD-41/eq False ceiling Finish: Stainless steel Hand rails: Stainless steel Mirror Finish on all sides of car Panels Flooring: Vinyl Car door finish: Stainless steel Landing door finish: Stainless steel Car & Hoistway Door Type: Central Operating (CO) doors AdvancedFeatures: E- call system, auto ionic sanitization COP: COP for Stops ≤ 12(950mm) in stain less steel Car position indicator/Hall button arrangements: LCD Monochrome Dot matrix multi color
Providing and fixing of Lighting point in loop wiring for lift with 1.5 mm2 PVC insulated copper wire of FRLS through PVC conduit pipe/ PVC channel with all necessary accessories including providing and fixing of ceiling rose of with round junction plate 5Amp switches recessed in wall using Modular plate of required size, point taken upto D.B. duly tested and commissioned, including holder etc.
Providing and Fixing of Bluck Heads including LED 9W lamp
Providing and fixing of 8 way Double door distribution Board
Providing and fixing of Heating points for lift using 4 sq.mmPVC insulated copper wire through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire t as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all as pects
Wiring for circuit (lift)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required ) Note : Rates of Suitable PVC conduit included in above description for the follwing items of make 4 X 10 sq. mm + 1 X 10 sq. mm earth wire
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 125 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 Amp 4 P MCCB
Foundation Construction of Foundation for 125 KVA servo transformer (as required at site) of 600mm high and 600mm deep below ground level, size (1500mmx1500mm) with roofin in CGI sheets along with supports etc in all respects . Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). As required as per site, complete in all respects.
Substation and LT networking 11 kV Double Pole Structure Supplying, installing, testing & commissioning of 2 pole structure for providing 1 no, 11kV, 200A GOS with following The rate to be include the following: 2 nos. 9 mtrs long MS steel poles complete pole excavation,MS steel foundation,back filling complete with MS steel channel/ angle iron etc. (9MTR +9 MTR)- 2 nos 75 mm x 40 mm 'C' channel ( 5 mtr. Long)- 7 Nos. 11 kV 200A TP Gang operated Air break switches complete with 25mm dia GI pipe operating machanism, handle & locking arrangement.)-1 Set 11 kV Drop out fuse (200A)-1 Set 11 kV Pin Insulator - 12 Nos 11 kV lightning arrestor and connecting to all phases- 3 nos. Caution Board & Anti-Climbing Devices-1 Set 50 mm Pin insulator for fixing LA earthing strip- 3 Nos. 1 No. 150 mm dia GI pipe class "E" ( for XLPE cable protection) as prequired.- 3 Mtrs. GI Nuts & bolts ( 300 mm long ) - 10 Nos. 11 kV ,90/120 kN Disc insulators with hardware - 3 Nos. ACSR Dog Conductor- 10 Mtrs 25 mm PVC pipe for conductor- 15 Mtrs 2 Set 50 mm dia 3m long GI pipe earthing with 50 x 6 mm GI earth strip complete as required (for GO, DO & LA).- 2 Set 50x6 mm Cu/Al earthing strip- 30 Mtrs. HDPE for cable included
supplying , errecting of 0.05 ACSR HT conductor on existing 11 KV HT poles
Providing , Erecting of 165.1mmx139.7mmx114.3mm swaged type steel tubular poles 410SP-31 of 9meters height with base plate/ top cap etc. and should be planted 1.50 meters deep concerted in M15 mix including cost of block above the ground around the SST pole (0.5 meters x 450mm dia.) in same concrete mix with finished plaster dully curried and applying of primer coats/paint coats as per site requirement complete.
Providing fixing of MS cross Arms 75 mm X 40 mm X 6 mm suitable for 11 KV line with bracing and clamps support duly painted ISI marked
Providing,fixing of 11KV pin type insulator including pin etc ISI Mark
Providing, laying , fixing of aluminum 300mm² PVC cable single core , XLPE un armoured 1.1 KV grade as per IS 7098(part 1) . (3 run for 630)
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 4 X 300 sq. mm
Providing, fixing of multi cable holding Solder less Clamps (brass) suitable for 630 KVA LT side with nuts bolts etc ISI mark.
Providing, fixing of MS Nuts & Bolts ,washers (Galvanized of sorts)
Providing/fixing of Anti-Climbing Devices heavy duty as per IS standards.
Providing, fixing of duly painted with required writing Danger Plate heavy duty as per IS standards.
Supplying, transportation, insurance, installation, testing & commissioning of pilfer resistant 11KV metering Kiosk suitable for housing Resin cast CT, PT and bi-directional Tri-vector meter fabricated out of MS Sheet steel of thickness not less than 2mm duly powder coat painted. The foundation base should be of MS channel iron not less than 100mmx50mmx6mm should be suitably grouted in M15 cement concrete. it should have two chambers, HV chamber and LV chamber both chambers having one side hanged door arrangement. The LV chamber shall be suitable for installation of tri-vector meter and HV chamber suitable for installation of CTs/PTs and termination of 11KV cable. it should be possible to take meter readings manually, through CMR and computer without opening the LV chamber door, including 11KV cables, the chamber also should contain the following essentials. a) 11kv CT 1set 40/5A for 630 KVA ISI mark. b) 11Kv/110V PT 3phase 1set resin cost of ISI mark. c) 1 set of copper bus bar duly insulated by the monopolist tape. d) Nuts bolts washers of brass as required. e) 1 lot of PVC insulated copper wire flexible multi-strand multi-core of required size for secondary connection. For CT wiring the minimum size shall be 4mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). f) Copper lugs preferably ring type duly crimped for termination of wires and cables. g) Grounding bus bar of minimum 40mm copper 25cm long fixed to the unit in HV chamber. The CTs and 11KV Cable sheath shall be grounded to the bus through grounding wire (green) of minimum 10mm2. h) Supply,fixing ,testing &commissioning of DLMS complaint HT, bi-directional Tri-vector meter of 3 phase/4wire/--5Amp &110/63.5volt i) Supply, fixing, testing & commissioning of 3 core 11KV aluminum XLPE armored cable 50mm2 of make including cost of thimbles/ clamps for fixing where ever required complete .From pole to transformer through metering chamber in all respects j) Supply, fixing ,testing & commissioning of Heat Shrink outdoor cable termination kit suitable for 3x50 sqmm, 11KV cable ISI mark. 4set k) Supply, fixing ,testing & commissioning of Heat Shrink indoor cable termination kit suitable for 3x50 sqmm 11KV cable ISI mark. 2set l) Supply, fixing of grounding to the metering in 40mm dia GI pipe 2.5 meter long including connectivity in all respects as per site requirement 2no. As per standards m) Bi directional Tri Vector Meter
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supply, installation, testing & commissioning of advance maintenance free Chemical Gel Earthing of Single Pipe Technology (Copper) of 3mtrs length 60-63 mm dia CHEMRODE filled with highly conducting metallic compounds with the permanent sealings at the both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connected the strip/wire to the load. including environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying /fixing /testing/ commissioning of 630 KVA level 2 copper wound transformer 11KV/433V 50 Hz 3ø, delta- star connections, ONAN type cooling, DYN11 Vector group ,including controling WTI, OTI, Bucholz Relay with alarm & trip Contacts, accessories, dehydration heat run complete including cost of transformer oil /loading un-loading/ Transportation/ in all respects etc . Complete job Note: all material used in manufacturing shuold be ISI certified and manufacturer be ISO certified Transformer should have five years manufacturer warranty or guaranty period
Foundation Construction of Foundation for 630 KVA HT / LT transformer (as required at site) of 1200mm high and 600mm deep below ground level, size (2400mmx2400mm). Excavating/ steel bars/ Reinforced cement concrete work in well-staining, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse Sand (zone-III): 3 graded stone aggregate 20 mm nominal size). As required as per site, complete in all respects.
Supply, installation, testing and commissioning of M.V. cubicle totally enclosed free standing type (stand height 1 meter INCLUDING CEMENT BOTTOMING) , Double door, fully out door type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,space heater, power outlet, illumination lamp, Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enameled painted and having following incoming and outgoing Circuit Breakers complete as required. 1 No. 1260 Amps 4P ACB (50KA) electrically operated manually draw out type air circuit breaker with microprocessor release unit for short circuit, over current Instantaneous and earth fault protection with adjustable setting & adjustable time setting as per specification with terminals suitable for cable connection on one side and Bus bar connection on other side. Suitable to receive Al./Cu. Armd Cables size Bus bar 1set TPN Aluminium 1260 Amp. for in commer and Out. 1 no. Digital metering OUTGOING: 2 No.1 No.630 Amps 4P MCCB (50KA) with suitable multi termination Bus bar connection on other side. Suitable to receive Al./Cu. Armd Cables size INDICATING & METERING Digital Multifunction Meter , with suitable rating Class-I CT's for each outgoing feeders For all out goings/ incoming LED indicating lamp with MCB protection. ADDITIONAL ACCESSORIES Following additional Accessories to be considered complete with wiring & controlled with suitable MCB. 6/16 Amp Power socket outlet with switch. 9 watt LED lamp controlled by door switch.Heating Element with switch & necessary protection.
supplying , errecting of of 7.5 meters height with base plate/ top cap etc. and should be planted 1.25 meters deep concerted in M15 mix including cost of block above the ground level around the SST pole (0.5 meters x 0.5meter dia.) in same concrete mix with finished plaster dully curried as per site requirement complete. including duly paint coating
Providing and fixing of 1.1 KV grade Reel spacer insulators including all fixing arrangements as required
Providing fixing of Shackle LT insulators including clamping duly painted clamps nuts and bolts what so ever required to install insulators
Providing fixing of Muki Clamps for LT insulators including nuts and bolts what so ever required to install insulators to hold the street light switching line.
supplying and errecting of 0.1 ACSR LT conductor in all respects
Supplying and erection of stay set complete (galvanised) with19/20mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench including sand cushioning and protective covering etc., complete as required. 150 mm dia for road cross
Supplying and fixing approved make fire buckets of 24 gauge galvanized steel sheet with 4 no sand buckets, standard 9 liters capacity as per IS:2546:1974 and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 4 buckets).
First Aid Kit as per Red Cross Standards, complete with Medicines for Burns, Cut Vomiting , Swelling , Cotton Wool, Cotton Bandage , Surgical Sprit etc placed in a wall mounting box with 6mm thick front hinged glass cover, with the sign " +" and the inscription "FIRST AID" in Red Paint - Overall size not less than 450mm x 300mm x 200mm deep in two tier shelf pattern.
Supplying of 6 pair tool set kit 1. plair,2. screw driver set,3. Adjustable spaner,4. Goti set 12 to 24 no,5. 2kg hammer 6 no. multimeter digital 2No.
CHAIN LINK FENCING Providing and Fixing Chain Link fencing with 9 gauge wire conforming to IS 2721 (2003) woven in a 50 mm (2 inch) mesh. Top and bottom selvage shall have twisted and barbed finish. Zinc‑coating weight shall be 570 grams/m2 2.0 ounces per square foot with following items (included) : Truss rods with turnbuckles or other equivalent provisions for adjustment. Top rail and bottom rails fitted with suitable expansion sleeves and means for securing rail to each gate, corner, and end posts. Top & Bottom tension wire as per ASTM A817 and ASTM F626, zinc‑coated, having minimum coating the same as the fence fabric. Item shall include accessories as necessary caps, rail and brace ends, wire ties or clips, braces and tension bands, tension bars, truss rods, and miscellaneous accessories conforming to ASTM F626.
Providing and laying in position of cement concrete M(1:2:4) in RCC for all types of structures including proper vibration and curing including broom finish if required including cost excavation, backfill etc of formwork and reinforcement etc all complete as per direction of EIC.
HUBBI ELECTRICALS
M/S ZAHID ENTERPRISES
F M INFRASTRUCTURE BUILDERS PRIVATE LIMITED
Powermech Engineering Services
stage.html
html • 0.03 MB
finance_396880.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .