Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.5 LAccepted-Finance | 1 | Accepted-Finance Admitted | |
| 2 | 2₹5.5 L+₹3,068 (0.56%)Accepted-Finance | 2 | Accepted-Finance Admitted | |
| 3 | Rejected-Technical | - | Rejected-Technical FDR/EMD is not submit | |
| 4 | Rejected-Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | - | Rejected-Technical FDR/EMD is not submit | |
| 5 | Rejected-Technical | - | Rejected-Technical FDR/EMD is not submit |
| Sl No | Description | Qty | Unit | Prime India Associates L1 | arun engineers and contractors L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of outdoor type 7.5 to 10 HP hut type electrical feeder pillar / metal board of welded construction of size 1370 mm x 760mm x 460 mm fabricated with 16 SWG MS sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double door with 14 SWG SS hinges along with double locking arrangement with arrangement for mounting of switchgear and electrical energy meter including powder coated, vermin proof having following item:
a) MCCB 63 Amp, 4Pole -1 No.
b) RCCB 63 Amp, 4Pole - 1 No
c) Fully automatic star delta starter (10 HP) 3 Phase oil immersed type -1 No.
d) Digital Ampere meter 96 x 96 mm. Square shape 0-30 Amp-1 No.
e) Digital Voltmeter 96 x 96 mm. Square shape 0-500 volt-1 No.
e) Indicating lamp (a set of 3 lamps) – 1.set
f) Shunt capacitor of 5 KVAR with 3 phase isolator – 01 No.
g) Motor protection assembly having earth leakage protection phase sequence connector, single phasing, protection, overload protection, high voltage / low voltage protection – 01 No.
h) Programmable time switch i.c. RYB phase facility to change over from automatic to manual & vice versa upto 10 H.P - 01 Nos.
i) Complete wiring of panel board installation of electrical accessories in the panel with required copper conductor wire and thimbeling etc. as required. The panel board shall be mounted on the base frame of 600 mm height made of 50x50x6 mm angle iron frame.
Make- Make of all the above components installed must be of DJB approved make. | 10 | Nos. | 4,67,400 ₹5,51,532 Lowest | 4,70,000 ₹5,54,600 |
Tender Value
Refer Docs
EMD Value
₹11,100
Closing Date
17 Dec 2025, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Procurement of feeder pillar for improvement of various tube wells in Khanpur ward under Ambedkar Nagar Constituency AC-48.
2025_DJB_282353_19
NIT No. 17/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
Works
3 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹11,100
Yes
7 Feb 2026
4 Dec 2025
17 Dec 2025
4 Dec 2025
17 Dec 2025
4 Dec 2025
Select, Excess (+), Less (-)
Tender Inviting Authority: EE(E&M)M-11
Name of Work: Procurement of feeder pillar for improvement of various tube wells in Khanpur ward under Ambedkar Nagar Constituency AC-48.
Contract No: NIT No. 17/EE(EM)M-11/(2025-2026)Item No-19
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Applicbale % of Basic Rate (on which Service Tax will be calculated) in Rs. P Applicbale % of Basic Rate(on which VAT will be calculated) in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P GST in % Service Tax in % GST Amount in Rs. P Service Amount in Rs. P Total Unit Price in Rs. P Total Amount in Rs. P Total Landed Cost (TLC) in Rs. P TOTAL AMOUNT In Words
1 Supply of outdoor type 7.5 to 10 HP hut type electrical feeder pillar / metal board of welded construction of size 1370 mm x 760mm x 460 mm fabricated with 16 SWG MS sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the panel robust, having double door with 14 SWG SS hinges along with double locking arrangement with arrangement for mounting of switchgear and electrical energy meter including powder coated, vermin proof having following item: a) MCCB 63 Amp, 4Pole -1 No. b) RCCB 63 Amp, 4Pole - 1 No c) Fully automatic star delta starter (10 HP) 3 Phase oil immersed type -1 No. d) Digital Ampere meter 96 x 96 mm. Square shape 0-30 Amp-1 No. e) Digital Voltmeter 96 x 96 mm. Square shape 0-500 volt-1 No. e) Indicating lamp (a set of 3 lamps) – 1.set f) Shunt capacitor of 5 KVAR with 3 phase isolator – 01 No. g) Motor protection assembly having earth leakage protection phase sequence connector, single phasing, protection, overload protection, high voltage / low voltage protection – 01 No. h) Programmable time switch i.c. RYB phase facility to change over from automatic to manual & vice versa upto 10 H.P - 01 Nos. i) Complete wiring of panel board installation of electrical accessories in the panel with required copper conductor wire and thimbeling etc. as required. The panel board shall be mounted on the base frame of 600 mm height made of 50x50x6 mm angle iron frame. Make- Make of all the above components installed must be of DJB approved make. item1 10 Nos. 80 100 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select %
Quoted Rate in Words
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.27 MB
BOQ_373105.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .