| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 60 4 MOTILAL GUPTA ROAD GROUND FLOOR KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹15.1 L+₹6.3 L (71.6%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹16.4 L+₹7.6 L (86.4%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L3 | Rejected-Finance Quoted Higher Rates | |
| 4 | L4₹17.2 L+₹8.4 L (95.5%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L4 | Rejected-Finance Quoted Higher Rates | |
| 5 | L5₹17.9 L+₹9.1 L (104.2%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹29,840
Closing Date
19 Nov 2020, 6:00 pmClosed
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION OF WIRING, FANS, ELECT METER, MCBS, DBS AT BHAGIRATHI, SARASWATI AND TEESTA UNDER GE (I) (CGP) KOLKATA
2020_MES_391918_1
8872/e8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹29,840
Yes
5 Feb 2021
2 Nov 2020
21 Nov 2020
2 Nov 2020
19 Nov 2020
13 Nov 2020
Amount
Taking out copper/aluminium point wiring cable from existing concealed conduit point wiring (light, fan, socket or power) complete, including fixture such as switches, ceiling roses, pendants, regulators, sockets, etc. removing materials from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. (Note:- Disturbed surfaces of wall shall be make good by applying two coats of OBD over a coat of wall care putty over cement mortar plaster (1:3) where necessary to match with existing surface finish)
M&L point wiring with 1.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FR copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for one light point / ceiling fan point / call bell point controlled by one way switches complete all as specified and directed. Note: Wiring wire color code i.e. Red/ Yellow /Blue for Phase, black for neutral and Green for earth shall be maintained.
All as per item no.02 above but for one light point controlled by two way switch.
All as per item no.02 above but for one three pin 5 Amp socket outlet on same board.
All as per item no.02 above but for one three pin 5 Amp socket outlet on independent board.
M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FR copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core HRFR / FRLS copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for 3 pin socket outlet 15 Amps on independant board complete all as specified and directed. Note: Wiring wire color code i.e. Red/ Yellow /Blue for Phase, black for neutral and Green for earth shall be maintained.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S & F Switch socket combination 5 Pin, 16/6 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed.
S & F Switch socket combination 5 Pin, 6 Amps, 240 Volts, flush type multi-purpose, conforming to IS complete all as specified and as directed.
S&F socket outlet 3/5 pin 5 Amps flush type complete all as specified and as directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, two way, conforming to IS complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type 100 watt on the existing phenolic laminated sheet etc. as reqd complete all as specified and as directed.
M&L call bell ding dong single pole complete all as specified and as directed.
S&F bell push flush type, 5 Amps 230 Volts complete all as specified and as directed.
M&L Sub main wiring with two runs of 6.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through and including rigid PVC non mettalic surface conduit medium duty with conduit accesseries such as junction boxes, bends, tees etc. complete including one run of 4.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one. (Note :-(i) One run of PVC conduit, Two runs of 6.0 sqmm single core cable, one run of 4.0 sqmm earth continuity wire to be measured as one length). (ii) Chase cutting for replacement of defective/ unserviceable concealing conduit by new conduit if ordered, shall be measured & Paid separately under respective item in this schedule.).
M&L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through and including rigid PVC non mettalic surface conduit medium duty with conduit accesseries such as junction boxes, bends, tees etc. complete including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one. (Note :-(i) One run of PVC conduit, Two runs of 2.5 sqmm single core cable, one run of 1.5 sqmm earth continuity wire to be measured as one length). (ii) Chase cutting for replacement of defective/ unserviceable concealing conduit by new conduit if ordered, shall be measured & Paid separately under respective item in this schedule.).
M&L cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps cills, sunshades, shelves, lintels etc. in brick walls and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc. 10 cm girth complete all as specified & directed. (Note:- Disturbed surfaces of wall shall be make good by applying two coats of OBD over a coat of wall care putty over cement mortar plaster (1:3) where necessary to match with existing surface finish).
S & F for 1x20 watt LED tube light with batten fitting and fixture including driver and all accesorries connecting with PVC insulated three core flexible 1.5 sqmm copper conductor cable with earthing complete all as specified and directed including taking down old one. (Make: CG cat no. LCTLN-20-CDL or equivalent in Bajaj/Havells)
S & F for 1x10 watt LED tube light with batten fitting and fixture including driver and all accesorries connecting with PVC insulated three core flexible 1.5 sqmm copper conductor cable with earthing complete all as specified and directed including taking down old one. (Make: CG cat no. LCTLN-10-CDL or equivalent in Bajaj/Havells)
S & F for surface mounted indoor decorative 2x2 LED luminaire , 24 watt suitable for gypsum ceiling complete and connecting with PVC insulated three core flexible 1.5 sqmm copper conductor cable from ceiling to rose complete all as specified and directed including taking down old one. (Make: CG cat no. LCTLSNE-24-FO-CDL or equivalent in Bajaj/Havells)
S & F for surface mounted indoor decorative 1x1 LED luminaire , 18 watt suitable for gypsum ceiling complete and connecting with PVC insulated three core flexible 1.5 sqmm copper conductor cable from ceiling to rose complete all as specified and directed including taking down old one. (Make: CG cat no. LCTLSNE-18-FO-CDL or equivalent in Bajaj/Havells)
S & F for LED light luminaire, 25 watt in pressure die cast aluminium housing, IP-66 protection with driver and accesories complete and connecting with PVC insulated two core flexible 1.5 sqmm copper conductor cable from ceiling to rose complete all as specified and directed including taking down old one. (Make: CG cat no. LSTS-25-CDL-M or equivalent in Bajaj/Havells)
S & F MS bracket made of 25 mm dia MS pipe medium grade 1.0 mtr long suitable for street light on wall with suitable bolts, nut etc. with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including taking down old one complete all as specified and as directed .
Supply and fix sheet steel enclosure SPN DBs, 8 way, double door for MCBs with 200 Amps rated bus bar complete all as specified and directed including taking down old one. ( Make Legrand cat No 5076 11 or equivalent equiv in Schneider /GE)
Supply and fix sheet steel enclosure SPN DBs, 4 way, double door for MCBs with 200 Amps rated bus bar complete all as specified and directed including taking down old one. ( Make Legrand cat No 5076 10 or equivalent equiv in Schneider /GE)
Supply and fix sheet steel enclosure TPN DB with provision for FP MCB as incomer and SP MCB as outgoing , double door type Number of way 4, No of module 8 + 12, complete all as specified and directed including taking out old one. (Make Legrand cat No 5076 70 or equivalent equiv in Schneider /GE)
Supply and fix MCB SP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4085 87-95 or equivalent in Schneider/GE )
Supply and fix MCB SPN 240V, 63 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4086 20 or equivalent in Schneider/GE )
Supply and fix MCB SPN 240V, 32 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4086 17 or equivalent in Schneider/GE )
Supply and fix MCB SPN 240V, 40 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4086 18 or equivalent in Schneider/GE )
S&F MCCB 63 Amps, 3 Pole,16 KA breaking capacity, 415V fixed magnetic setting Type - DPX 160 including taking out old one complete all as specified and directed.(Cat -4200 03 of Make- Legrand or L&T/Schneider)
S&F MCCB 100 Amps, 4 Pole,16 KA breaking capacity, 415V fixed magnetic setting Type - DPX 160 including taking out old one complete all as specified and directed.(Cat -4200 15 of Make- Legrand or L&T/Schneider)
M & L for dismantling burnt winding of ceiling fan (any size/ sweep/make) and taking out existing winding wire, and rewinding the same after proper cleaning with super enamelled copper winding wire as per existing gauge and turn to achieve the required RPM, cleaning/ replacement of bearings, bushes capacitor etc as required and testing complete for fan of old model requirement of super enamelled winding wire n.exc. 500 grms complete all as specified and directed.
M & L for dismantling of burnt motor of exhaust fan and taking out existing winding and rewinding the same with super enamelled bare insulated copper winding wire as per existing gauge and turn to achieve required RPM including replacement of unserviceable parts as required and testing complete all as directed of size 225 mm to 350 mm sweep. complete all as specified and directed.
Taking down repairable exhaust fan of any size/sweep from existing position including taking down old connections wire complete all as directed and keep in safe custody for repairs and refixing the same on the same / different location with provision of new flexiable wire including cleaning of external surfaces & servicing the fan by dismantling complete greasing oiling and replacement of unserviceable parts as complete all as specified & directed ( Note :- Any parts needed to be replaced for satisfactorily running of exhaust fan shall be measured and paid separately under appropriate items.)
Supply only capacitor of capacity 2.5 mfd 230 volt suitable for exhaust fan of any make / model and sweep .
Supply only Ball bearing No. 6201 suitable for exhaust fan of any sweep.
Taking down repairable ceiling fan of any size/sweep from existing position including taking down old connections wire complete all as directed and keep in safe custody for repairs and refixing the same on the same / different location with provision of new flexiable wire including cleaning of external surfaces & servicing the fan by dismantling complete greasing oiling and replacement of unserviceable parts as complete all as specified & directed (Note :- Any parts needed to be replaced for satisfactorily running of exhaust fan shall be measured and paid separately under appropriate items).
Supply only capacitor of capacity 2.5 mfd 230 volt suitable for ceiling fan of any make / model and sweep .
Supply only Ball bearing No. 6201 suitable for ceiling fan of any sweep. (Make- TATA/SKF or equivalent)
Supply only Ball bearing No. 6202/6203 suitable for ceiling fan of any sweep. (Make- TATA/SKF or equivalent)
Supply only MS split pin size 2''x1/8'' for ceiling fan of any sweep.
Supply only rubber bush of size1,1/2" dia x 1'' thick for ceiling fan of any sweep.
Supply only capacitor of capacity 4.0 mfd 230 volt suitable for ceiling fan of any make / model and sweep .
M&L for painting to ceiling fan of any sweep complete with one coat of synthetic enamel paint by spraying including filling cavities with fillar with necessary preparation of surface including hanging the ceiling fan and connecting up complete all as directed.
M&L for painting to exhaust fan of any sweep complete with synthetic enamel paint by spraying including filling cavities with fillar including necessary preparation of surface including refixing the same at site complete all as directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed including taking down old one.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed including taking down old one.
S & F Switch socket combination 6 Pin, 16/6 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed including taking down old one.
S & F Switch socket combination 5 Pin, 6 Amps, 240 Volts, flush type multi-purpose, conforming to IS complete all as specified and as directed including taking down old one.
S&F socket outlet 3/5 pin 5 Amps flush type complete all as specified and as directed including taking down old one.
S&F bell push flush type, 5 Amps 230 Volts complete all as specified and as directed including taking down old one.
M&L electrical and musical type bell AC 230 Volts single pole complete all as specified and as directed including taking down old one.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and as directed including taking down old one.
S&F of RCCB's for earth leakage protection double pole sensitivity 30mA, 63Amps capacity incl taking down old one complete all as specified and directed.( Make : Legrand cat No 4118 53 or equivalent of /ABB/Schnieder. )
M & L earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected with 4mm dia GI wire by means of bolts washers and protected by 15mm bore, medium grade GI pipe, funnel with 20mm bore GI medium grade watering pipe, wire mesh, copper lugs including concrete pit in PCC 1:3:6 type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350X350X50 mm, reinforced with 8mm dia deformed bars @15 cm C/C both direction and 10mm MS handle of suitable size, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil, all as shown in Electrical Plate No 3 of MES Schedule Part-I and testing, complete all as specified and as directed.
Supply and fixing in repairs single phase KWh meter with LCD display, 1P LCD meter 5-30A with box, including connection wire and grouting of nut, bolts, complete all as specified and directed. (Make- L&T model no EM 101+ class 1 base mounting Cat No WM101BC5DL0BOX or equivalent in C&S/HPL/ABB)(Note-Old u/s meter shall be h/o to MES department)
UNIVERSAL TRADING CENTRE
M A ENTERPRISES
MS HORIZEN
Somani Builders
BASU AND CO
MS JYOTI INDUSTRIES
JOY-EN-JOY
DEB AND COMPANY
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .