Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹46.1 L+₹2.9 L (6.82%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹46.8 L+₹3.6 L (8.32%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹47.4 L+₹4.2 L (9.81%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹48.0 L+₹4.8 L (11.1%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Feb 2025, 6:00 pmClosed
GE AF Chabua
Office of GE AF Chabua, PIN-786102
As per BOQ Details
2024_MES_684084_2
540/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chabua
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF Chabua
₹80,000
Yes
25 Apr 2025
21 Jan 2025
22 Feb 2025
21 Jan 2025
20 Feb 2025
6 Feb 2025
Amount
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 800 to 1250 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CTC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. d) Check arching contact for damage . e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation. j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like Shunt release & trip coil/motor etc will be measured & paid separately under relevant schedule items
Supply only fixed arching contact suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
Supply only moving arching contact suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
Supply only shunt trip (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating upto 1250 Amps as all per existing of Make complete all as specified and directed.
Supply only under voltage release 240V AC suitable for air circuit breakers of rating upto 1250 Amps as all per existing of Make complete all as specified and directed.
Supply only closing coil suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
Supply only charging motor 240 V AC suitable for air circuit breakers of rating upto 1250 Amps complete all as specified and directed.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 630 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 400 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction by Engr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 315/320 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 250 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 200 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 100 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.as per direction byEngr-in-Charge complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with MS enclosure, advance neutral on load ,current rating 63 Amps,415 volts fron/side operated including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 630 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 400 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 320 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 250 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 200 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 160 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 125 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 100 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
Supply and fix in replacement of four pole Change over switch with open execution type, advance neutral on load ,current rating 63 Amps,415 volts fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 32 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 63 Amps with breaking capacity 16 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 63 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 100 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 100 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 125 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 125 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 160 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 160 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 200 Amps with breaking capacity 25/27 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 200 Amps with breaking capacity 35/36 KA,50 Hz cfixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 3 pole, 415 volt 250 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 250 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 320 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 350 Amps with breaking capacity 35/36 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 400 Amps with breaking capacity 35 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 630 Amps with breaking capacity 36/37 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
S&F in repair MCCB 4 pole, 415 volt 630 Amps with breaking capacity 50 KA,50 Hz fixed with panels including any type of addition/alteration complete all as specified and directed at site.
All as per ser item No 42 here-in- before but 150 KVR APFC panel board.
All as per ser item No 42 here-in- before but 80 KVR APFC panel board.
All as per ser item No 42 here-in- before but 70 KVR APFC panel board.
All as per ser item No 42 here-in- before but 50 KVR APFC panel board.
All as per ser item No 42 here-in- before but 30 KVR APFC panel board.
S&F in repair power factor improvement static condenser of size 1 KVR (Capacitor) of required capacity all as specified and directed at site.
All as per ser item No 48 here-in- before but 2 KVR capacitor.
All as per ser item No 48 here-in- before but 4 KVR capacitor.
All as per ser item No 48 here-in- before but 5 KVR capacitor.
All as per ser item No 48 here-in- before but 7.5 KVR capacitor.
All as per ser item No 48 here-in- before but 8 KVR capacitor.
All as per ser item No 48 here-in- before but 10 KVR capacitor.
All as per ser item No 48 here-in- before but 12.5 KVR capacitor.
All as per ser item No 48 here-in- before but 15 KVR capacitor.
All as per ser item No 48 here-in- before but 20 KVR capacitor.
All as per ser item No 48 here-in- before but 25 KVR capacitor.
S&F in repair power contactors MCX 34 4 pole complete all as specified and directed at site.
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
S&Fix in repair contactor MNX 9 complete all as specified and directed at site.
S&F in repair 3 pole MO C5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 pole MO C8.5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 Pole MO C10 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 Pole MO C12.5 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 Pole MO C15 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 Pole MO C20 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
S&F in repair 3 Pole MO C25 capacitor duty contactor with auxiliary contact 01 NO complete all as specified and directed at site.
Supply and fixing in repair of MCB TP 415 volts 16 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TP 415 volts 20 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TP 415 volts 25 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TP 415 volts 32 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TP 415 volts 63 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TPN 415 volts 40 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing in repair of MCB TPN 415 volts 63 amps, 'C' curve, 10 KA complete all as specified and directed .
Supply and fixing, in repair detuned reactor, copper wound 440 V, 50 HZ of capacity 1 KVR complete all as specified and directed.
All as per ser item No 76 here-in- before but 2 KVR
All as per ser item No 76 here-in- before but 3 KVR
All as per ser item No 76 here-in- before but 4 KVR
All as per ser item No 76 here-in- before but 5 KVR
All as per ser item No 76 here-in- before but 8 KVR
All as per ser item No 76 here-in- before but 10 KVR
All as per ser item No 76 here-in- before but 12.5 KVR
All as per ser item No 76 here-in- before but 15 KVR
All as per ser item No 76 here-in- before but 20 KVR
All as per ser item No 76 here-in- before but 25 KVR
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level ) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to main GI strip 32 x 6 mm as earth strip by means of bolts ,nuts and washers of galvanised iron or steel as shown in electrical plate No. 3, including exc , and earth work in any type of soil disposal of soil providing alternate layers of charcol and common salt construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick 1:2:4 type B-1 cover reinforced with 8 mm dia MS bars both ways with lift hook made out of 8 mm dia bar,watering arrangement. Note : Main earth strip beyond 7.5 meter shall be measured and paid saperatly. Taking down old unserviceable dilapidated chemical earthing are included in quoted rate. Note : (1) 7.5 RM GI strip deemed to be included in quoted rates beyond 7.5 RM GI strip shall be measured and paid separately. (2) Earth resistance of earth pit should be less than 5 Ohms.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI Plate.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
M&L for painting on old painted surface of LT panels by brushing/cleaning stains & grease spots with thinner and sand paper and painting the cleaned surface with synthetic enamel paint (Light gray) Shade No 631 or as approved by the Engr-in-charge to achieve good finish by applying two coats of paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc with white paint on newly painted surfaces details as given by Engr-in-charge
S&F in repairs MS sheet covers/doors of any thickness and shape for LT panels including required fabrication,welding,cutting etc and fixing of hinges, including locking arrangement as per site requirement all as specified and directed at site.
Disconnecting electrically switch boards/ electric panels/ distribution boards of any size by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/burnt out//overheated cable ends/ thimbles etc including excavation /earthwork etc and M&L for fixing of new aluminium lugs of any size up to 300 sqmm as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing system.Note :- (i) any addition/alteration required included in the quoted rate in the items. (ii) All consumable items such as lugs/cable piece etc required at site included in the quoted rate in the items.
Singhs Construction (BID ID -3244520)
M/S Dee Dee Singhania & Sons (BID ID -3244092)
M/s Pramillabh Construction (BID ID -3244131)
M/s Sashi Enterprise (BID ID -3244163)
M/S RK Trading (BID ID -3244495)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .