Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.0 CrAccepted-AOC 17 SADAR BAZAR JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹6.0 Cr Quoted ₹6.3 Cr | L-1 | Accepted-AOC L1 |
| 2 | L-2₹6.4 CrRejected-Finance 560 SADAR BAZAR JHANSI UTTAR PRADESH 284001 UDYAM UP 39 0009380 09AACFT8755H1ZP R M | JHANSI | UTTAR PRADESH | 284001 | ₹6.4 Cr | L-2 | Rejected-Finance L2 |
| 3 | Rejected-Technical KARNATAKA | RAICHUR | KARNATAKA | 584123 | - | - | Rejected-Technical Non-Responsive |
Updated dates
Tender Value
Refer Docs
EMD Value
₹13 L
Closing Date
17 Mar 2026, 12:00 pmClosed
Superintending Engineer
S.E., PMGSY Circle, PWD, 15/5 Civil Line Kanpur
Construction work of 08 no Type 4 houses in the old Executive Engineer Complex of District Jhansi
2026_WBEAP_1120467_1
427/167C-PMGSYC/2025-26 DT. 20.02.2026
Open Tender
Civil Works - Buildings
365 days
jhansi
Please refer Tender documents.
2 documents required · 2 mandatory
₹9,450
₹13 L
S.E., PMGSY Circle, PWD, 15/5 Civil Line Kanpur
18 May 2026
27 Feb 2026
17 Mar 2026
27 Feb 2026
17 Mar 2026
27 Feb 2026
6 Mar 2026
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:DSR 2.6.1
Providing and laying in position cement concrete in Foundation 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)DSR4:1:8
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding in Super Structure. Thermo-Mechanically Treated bars of grade Fe-500D or more.DSR 5.22.6
Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 4.1.2
Brick work with nonmodular fly ash bricks confirming to IS:12894, class designation 10 in foundation. Cement mortar 1:4 (1 cement : 4 coarse sand)DSR6.34.1
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.DSR 2.35.2.1 & 2.35.1
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: DSR 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1%
Earth work and filling with cartage 5 Km. distance including loading, unloading, levelling and dressing etc complete.Analysis
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, including the cost of centering, shuttering and finishing : 1:1½:3 (1 cement : 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 4.2.2
Brick work with clay fly ash bricks (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) With F.P.S.(non modular) bricks :dsr6.32.2
Half brick masonry with (non modular) fly ash bricks of class designation 10 confirming to IS:12894 in sup structure above plinth up to floor V level 1:4 (1 cement : 4 coarse sand) dsr6.45.2
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x6mm, joints mitred and welded by angle iron 40x40x6mm or 40x 6 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. Dsr 10.31
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. Dsr 9.48.2
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1, 35 mm thick Fixing with hinges of required size and necessary screws Dsr 9.20
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) 9.22.1 On one side only Dsr 9.22
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 9.27.1 35 mm thick shutters 9.27.1.1 with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1.1 Second class teak wood Dsr 9.27
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 9.47.2 25 mm dia (heavy type) Dsr 9.47
Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : 9.71.1 125x64x2.50 mm Dsr. 9.71
A Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body. 9.147.A2.1Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) (Height upto 1.8m). Dsr 9.147
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
13.16 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) FOR SLAB,BEAM CEILING
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm DSR 11.41A.1.1
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mix) having VOC content less than 50 gram/litre, of approvved manufactiurer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement prime DSR 13.41.1
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Varnishing with varnish of approved brand and manufacture: One or more coats with copal varnisH DSR13.113.2
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red DSR 11.56
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by thee Engineer-in-Charge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate.
Centering and shuttering including strutting, propping etc. and removal of from for Foundations, footing, bases of columns etc for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of from for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of from for Columns, pillars, abutments, post and struts
Centering and shuttering including strutting, propping etc. and removal of from for Lintels, beams,slab, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick.
providing and fixing white viterious china pedestal type water closet(Eropeantype)w.c pan with ISI marked white solid plastic seat and lid 17.3.1
Wash hand basin 550x400 mm size of white glazed earthen ware DSR 17.7A
Providing and fixing PTMT Bottle Trap for Wash basin and sink.17.70.2, Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms DSR 17.71
C.P. Brass towel rail 600 MM LONG mm together with pair of C.P. brass brackets to fit the towel rail. 17.73.2
P.V.C ball float valve with brass and union complete 15 mm dia C.P BRASS FITTINGS DSR 18.8.1
P.V.C ball float valve with brass and union complete 25MM DSR 18.18.3,
C.P bib cock heavy quality (Gem Mikadeo/Encess’s williams or eqv.) 18.49.1, 15MM DSR 18.49
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore15 mm nominal bore DSR 18.51.1,
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore15mm nominal bore DSR 18.53.1,
150MM DIAC.P Brass shower heavy quality (Gem Mikadeo / Encess’s williams DSR 18.22.2
providing and fixing gun metal gate valve with C.I wheel of approved quality 25mm dia DSR 18.17.1
providing and fixing gun metal gate valve with C.I wheel of approved quality 20mm dia DSR 18.17.1A
providing and fixing gun metal gate valve with C.I wheel of approved quality 32mm dia DSR18.17.1
providing and fixing gun metal gate valve with C.I wheel of approved quality 40mm dia DSR 18.17.3
C.P Brass stop Cock 20 mm DSR 18.16.2
CP Brass Stop 15MM Cock DSR 18.16.1
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. completeS. 110MM PVC PIPES &FITTIMGS AND RAIN WATER PIPES DSR 12.43.2
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 12.42.1.2 coupler 110mm DSR 12.43.2
single pushfit coupler 110mm DSR 12.42.2.2
Single tee with door DSR 12.42.3.2
Single tee without door Dsr 12.42.4.2
Bend 87.5 DSR 12.42.5.2
Shoe DSR 12.42.5.2
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm dia meter and waiting not less than 440 gram DSR 12.44
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR 12.22
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etcConcealed work, including cutting chases and making good the walls etc..INTERNAL & EXETERNAL WATER SUPPLY WORKS18.8.1, 15 mm nominal outer dia Pipes DSR 18.80
20 mm nominal outer dia Pipes DSR 18.8.2
25 mm nominal outer dia Pipes DSR 18.8.3
32 mm nominal outer dia Pipes DSR 18.8.4
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. ETERNAL WORK18.9.5 40 mm dia nominal bore DSR 18.90
Providing and fixing Fullway Gate Valve with C.I. wheel of approved quality18.17.1A 20 mm nominal bore DSR 18.17.1
Providing and fixing Fullway Gate Valve with C.I. wheel of approved quality18.17.1 25 mm nominal bore DSR 18.17.1
C.P Stop cock heavy quality (Gem Mikadeo/Encess’s williams or eqv.) DSR 18.52.1
Supply and installing of low density polyethylene seamless one peace moulded tank and placing the same in proper position including all taxes labour and T&P etc for proper completion of the work. Tank should be ISI marked (for 500 Liters)Capacity in per liters DSR 18.48
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m SEWERAGE SYSTEM Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia All kinds of soil DSR 2.10.1.2,
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :100 mm diameter DSR 19.1.1,
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete150 mm dia. R.C.C. pipe DSR 19.6.2
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design 150 mm diameter R.C.C. pipe DSR 19.2.2
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:150 x 100 mm size P type DSR 19.4.2.2
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 15 DSR 19.7.1.1
Extra for depth for manholes :Size 90x80 cm with First class brick DSR 19.8.1.1
HEP nahani trap of indian make HCI 100*75mm. 4kg chapter 22 si no. 60
P/F 0f submersible pump I/c supply 0f approved quality motoer of 2Hp I.S.I mark and boaring casing Dia of 125 mm with starter panel cable and necessarily all fittings comp with labour T&P ctc. Rquired for proper completion of work as per direction of ingineer E/i
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25 DSR 16.78.2 For Road
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 16.79For Road
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). DSR 16.75For Road
Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2For Road
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) DSR 5.2.2 FOR RWH
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. FOR RWH
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar D.S.R. 19.15.1 FOR RWH
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality MD-10-circular shape 560 dia internal dia meters FOR RWH
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.23.1.1 All types of soil 300 mm dia FOR RWH
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (200mm nominal size dia) FOR RWH
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. FOR RWH
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 10 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. FOR RWH
Supplying, filling, spreading & leveling stone boulders of size range 1.5 cm to 2 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. FOR RWH
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. FOR RWH
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : FOR RWH
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m FOR RWH
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. Complete 150mm dia. R.C.C. Pipe FOR RWH
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter R.C.C. Pipe FOR RWH
Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminium paint of approved brand and manufacture over a priming coat of ready mixed zinc chromate yellow primer on new work : 75 mm diameter pipes 13.95.1FOR SAPTIC TANK
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 D.S.R. 19.32.1FOR SAPTIC TANK
Construction of Masonary chambers(60x60 CM) DRS Sl no 18.33 FOR SAPTIC TANK
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 FOR DRAIN
Supply & Fixing of 63Amp TPN (Disconnector Fuse Switch) DIN Type Make-Havells or equivalent
Wiring for Light point Point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B)
Wiring for Fan and Fresh air Point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B)
Wiring for Call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B)
Wiring for Twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings) (For Plug Point and Aquaguard)((2 No. for TV)
Supply and Fixing of brass Angle holder including connection etc. as required.
Supplying and drawing 1 x 1.5 sq. mm size of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (For Inverter Wiring)
Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 25 A modular socket outlet with 25 A modular SP MCB C curve including connections painting etc. as required. (AC & Geyser)
Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.
Supply and Fixing of 4 way (4+12), Double Door, Horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator).
Supply and Fixing of 6 way (4+18), Double Door, Horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator).
S/F of 63Amp Four Pole MCB (10KA), C curve Make-Havells or equivalent
Supplying and fixing of 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply and fixing of 25/32 amp rating 240/415V, 10KA, C curve DP MCB suitable for inductive load in existing DB complete with connections, testing and commissioning etc. as required.
Supply and fixing of 5 to 32 amp rating 240/415V, 10KA, C curve SPMCB suitable for inductive load in existing DB complete with connections, testing and commissioning etc. as required.
LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt
Supply and Fixing of 9 watt LED DECORATIVE WALL light Complete in all Respect.Make Havells or Equivalent 360-720 systems lumens, 120lm/W, PF › 0.95, THD <10% , CRI>80,with 5 years warrantee Make-Havells or equivalent.
LED Down lighter (SMD Type) (System lumen efficacy ≥120<135lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium body inccluding trimming. 18 watt
Supply and Fixing of 20 watt LED Mirror Light Complete in all Respect.Make Havells or Equivalent 2160-2400 systems lumens, >120lm/W, PF › 0.95, THD <10% , CRI>80,with 5 years warrantee Make-Havells or equivalent.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90 degree. 90Watt.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Submain wiring along with earth wire with the 2 x 1.5 sqmm +1x 1.5 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(for Plug,Computer, Aquaduard,TV point)
Submain wiring along with earth wire with the 2 x 4 sqmm +1 x 4 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Power Plug)
Submain wiring along with earth wire with the 2 x 6 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(AC and Geyser)
Submain wiring along with earth wire with the 2 x 10 sqmm +1 x 6 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Submain wiring along with 4×25 Sqmm + 2×6 Sqmm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Supply and Laying of 400 Sq mm 3-1/2 Core Aluminium Conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by Engineer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
Brush Less Direct Current (BLDC) Fan without Remote - Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, airdelivery 210 CM/Min (Minimum)
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supply and Fixing of BLDC Fresh air Fan 200 mm size sweep single phase including cartage and fixing Complete in all respects.Make Havells or equivalent
Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and Fixing of 25 Litre Geyser Make-Havells or equivalent.
Meter Panel Board:- Design, Manufacturing, Supply installation, testing and commissioning of LT meter panel board suitable for 433 V, 3 phase, 4 wire, 5 Hz power distribution system. The panel shall be Indoor, free standing, floor moutning sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14/16 SWG CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate each bus bar of adequate cross section through out of the length of the panel. The incoming and outgoing feeders shall be accommodated in a fully segregated, modular multitier arrangement with adequate size and distinct cable alley, bus bar alley/ chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. The panel shall a) 1 Nos Incoming 400A 36 KA FP MCCB with O/C & S/C Protection , phase indicating lights. b) 9 Nos Outgoing 63A 36 KA FP MCCB and with space for Mounting 3 Phase Energy meter.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_2084215.xls
BOQ • 0.40 MB
CBDJhansi.pdf
Tender Documents • 2.41 MB
Download all tender documents and submit your bid