Execution of indoor and outdoor signalling work and alteration of Existing Electronic Interlocking System (Centralized) of Make: M/s Siemens Rail Automation Pvt Ltd at PURI station in connection with one new island Platform in between Rt 1A- 300 M , 1B-300 M & extension of existing engine stabling line-110 m at Puri Railway station of Khurda Road division of East Coast Railway
STCBBSPURI-ISLAND-eOT27~ECOR
STCBBSPURI-ISLAND-eOT27
Open
Works - General
4 Months
Khordha, Odisha
₹0
₹3.2 L
26 Dec 2025
25 Nov 2025
12 Dec 2025
C-Drawing & Design
Design of SIP & submission of Three paper copies for approval For a Eight-Line Station or more
Design of SWRD & submission of Three paper copies for approval For a Eight-Line Station or more
Design of Cable Route Plan (Distant to Distant) & submission of Three paper copies for approval For a Eight-Line Station or more
Design of Cable Distribution Plan & submission of Three paper copies for approval For a Eight-Line Station or more
Design of Circuit Diagrams consisting of the items as mentioned below & submission of 5 Three paper copies for approval (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems For a Eight-Line Station or more Note : Unit should be read as Per Station
Design of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval For a Eight-Line Station or more Note : Unit shoule be read as Per Station
Design of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval For a Eight-Line Station or more Note : Unit should be read as Per Station.
Supply of Original Tracing of SIP after incorporating all the corrections. For a Eight-Line Station or more
Supply of Original Tracing of Cable Distribution Plan after incorporating all the corrections. For a Eight-Line Station or more Note : Unit should be read as Per Station
Supply of Original Tracing of Circuit Diagrams consisting of the items as mentioned 10 below after incorporating all the corrections. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for EI Systems For a Eight-Line Station or more Note : Unit should be read as Per Station
Supply of Original Tracing of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) after incorporating all the corrections. For a Eight-Line Station or more. Note : Unit should be read as Per Station
Supply of Original Tracing of Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) after incorporating all the corrections. For a Eight-Line Station or more.
Supply of Original Tracing of Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) after incorporating all the corrections.For a Eight-Line Station or more Note :Unit should be read as Per Station.
Supply of Original Tracing of Cable Route Plan (Distant to Distant) after incorporating all the corrections.For a Eight-Line Station or more
Alteration of Existing Location Box Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval Note : Unit should be read as Per Sheet
Alteration of Existing Goomty Drawings (Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc) and submission of Three paper copies for approval Note : Unit should be read as Per Sheet.
Supply of Amonia Print of Approved Cable Route Plan(Distant to Distant).For a Eight- Line Station or more
Supply of Amonia Print of Approved Circuit Diagrams consisting of the items as 18 mentioned below. (i) Wiring Diagrams (ii) Relay Disposition Charts (iii ) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars For a Eight-Line Station or more Note : Unit should be read as Per Station.
Supply of Amonia Print of Approved SIP . For a Eight-Line Station or more
Supply of Amonia Print of Approved SWRD. For a Eight-Line Station or more
Supply of Amonia Print of Approved Cable Distribution PlanFor a Eight-Line Station or more
Supply of Amonia Print of Approved Location Box Drawings (Including Contact Analysis, Fuse Particulars etc).For a Eight-Line Station or more Note : Unit should be read as Per Station.
Supply of Amonia Print of Approved Goomty Drawings ((Including Relay Disposition Chart, Contact Analysis, Fuse Particulars, CT Rack Particulars and Floor Plan etc).For a Eight-Line Station or more Note : Unit should be read as Per Station.
"Supply of Original Tracing in A-3 Size. NOTE:- For Drawings larger than A-3 Size, payment shall be made in multiples of A-3 Size. " Note : Unit should be read as Per Sheet
"Supply of Amonia Prints in A-3 Size. NOTE:- For Drawings larger than A-3 Size, payment shall be made in multiples of A-3 Size. " Note : Unit Should be Read as Per Sheet/
[b] Compilation, preparation, correction, updating, printing and supply of Final station working rules with contractor's stationery, tools, plants and materials.Note: Final SWR to be submitted in 2 sets ( Hindi & English) for each station. Note : Unit should be read as Page
[d] Printing and supply of approved SWR with contractor's stationery, tools, plants and materials.Note: Approved SWR to be submitted in 20 copies ( Hindi & English) for each station. Note : Unit should be read as Page.
[e] Colour Printing and supply of Top covers with Station Photo for SWR with contractor's stationery, tools, plants and materials.
[f] Hardboard binding and supply of 6 copies of station/Gate working rules with contractor's stationery, tools, plants and materials.
[g] Supply of soft copy in CD of station/Gate working rules with contractor's stationery, tools, plants and materials.
A1-EI Execution Schedule: Note for Item No. 1 to 5: The tenderer
Modification and designing of WESTRACE MK2 EI system (logic circuit and Interface 01 circuit including VDU,MT application,software and Datalogger database updation) as per approved SIP for alteration of Electronic Interlocking System(Centralised) of Make: M/s Siemens Rail Automation Pvt Ltd for PURI station. VDU & MT logic to be 4K based.
Alteration in wiring of existing Electronic Interlocking System (Centralised 02 configuration with Hot standby feature) of Make: M/s Siemens Rail automation Pvt Ltd , testing and commissioning including supply of wire coils, wiring, materials, Fuse, WAGO terminals, connector materials etc at PURI station.
Supply of as made documents as per east coast railway practice.
Factory acceptance test (FAT) with Railway Officials as per RDSO guidelines and extant practice.
Site acceptance test (SAT) with Railway Officials as per RDSO guidelines and extant practice.
Provision of Maintenance free perimeter Earth/Ring Earth for EI equipment, Relay Racks, Power equipment along with the supply of all requisite materials as per Signal Engineering 06 practice. Site specific Diagram of perimeter Earth/Ring Earth should be supplied to Railway for approval. Execution to be done as per the approved diagram. Materials for earthing and bonding to be inspected by RDSO. The Technical specification of Ring earth is enclosed in the technical specifications at Chapter-8- Section-H. Above/
A2-Indoor & Outdoor Execution Schedule
Alteration of wiring in existing apparatus cases full/half. This includes supply of all 01 materials in connection with alteration in wiring. All the materials shall be supplied by the contractor at his own cost. This includes entry of cables, sand filling and masonry work involved. Lettering and painting to be done by the contractor at his own cost. Railway shall supply only relays and relay bases.
Fixing of relay bases and wiring, bunching, fixing of relays, wiring in Old relay racks/location box and also carrying out any alteration in existing relay rack duly wiring and 02 connecting New to old and Old to old relays by standard wires (RDSO Approved Sources) as per Circuit diagram. Fuses of bases, condensers, ND fuses, LED indicator & its wiring for relay rack. All materials required for this work will be supplied by the contractor from RDSO Approved Sources. Relays with accessories will be supplied by the Railway.
Supply, installation, testing and commissioning of Maintenance free and permanent earth as per RDSO Specification No. RDSO/SPN/197 Version 1.0 and Technical Specification as per section H, Chapter 8. Materials for earthing and bonding to be inspected by RDSO.
Transportation & fixing of Calling On Signals/ dependent shunt signals with marker for 04 multiple aspect colour light signals on the erected signal posts complete with marker including termination of cables, wiring, signal testing, and focussing. Railway will supply only calling-on- signal/dependent shunt signal with off-set bracket from stores. Tenderer shall supply all other materials required for the work.
[iii] Fixing of Calling On LED type lamp unit with current regulator in Calling on signal unit. This includes taking the cable inside the unit, fixing of current regulator etc., complete wiring, 06 fitting of terminals, LED signal lamps, and fittings as required. The painting and lettering of existing markers and numbering plate to be done by enamel paint. All materials including PVC wires, blanking stretcher, PVC flexible pipe, hylum strip (6 mm thick), terminals and all sundry materials are to be supplied by the contractor. Railway will supply LED Units.
Transportation, installation of point machine on MS plate fixed on wooden/psc/steel sleeper complete with fixing of anti theft arrangement, 'D' Bracket, junction boxes, connection including smithy works involved for ground connection, including rivetting/welding of angle cleats, 07 termination of cables. Preliminary adjustment for operation of points by crank handle. oiling, greasing, painting and lettering as required. This also includes supply and fixing telescopic arrangement using GI pipes of required dia for provision of wires from junction box to point machine. Railway will supply point machine, ground connection from stores. Tender shall supply all other materials required for the works.The contractor shall overhaul the point machine before installation.
Wiring and testing of electric point machine as per the wiring diagram supplied by the 08 Railway. This also includes the connection of complete ground connections of electric point machine and fixing of insulation materials and providing one numbers of seven lever [7 levers] Godrej locks with three keys each, per machine for outside cover, fixing arrangement of crank handle interlocking in point machine, and fixing of 'E' type lock [if required]. Railway will supply electric point machine, ground connections with insulations and junction boxes. Tenderer shall transport the materials issued by Railways to the site of work at his own cost and shall also supply materials such as PVC wire for wiring, one numbers of Godrej (7 Levers) locks with three keys each per lock, per point machine, and any other materials that are required for installation, wiring, testing and commissioning of the said work at his own cost. Also Preparation of point parameter history records and maintenance register duly recording the measurements in prescribed format jointly with Railway representative and handover all records to the Railway.
b] Installation of Curved Portion (Point Zone) track circuits including supply of materials as per directive of site Engineer. NOTE: (i) This includes drilling 9/32" holes on rails, provision of bonding, fixing of track lead junction box, provision of track lead jumper wires, fixing of track circuit equipment i.e. track charger, resistance, fuses, batteries, chokes, relays, anti-titling 10 arrangement (if required), painting, lettering and numbering etc. This includes insulation of gauge tie plates, Crossing plates, rod in siding points if required or any other place as instructed by Railway Site Engineer, by tenderer's insulation materials. (ii) Preparation of Track circuit history records and maintenance register duly recording the measurements in prescribed format jointly with Railway representative and handover all records to the Railway. NOTE: 1.Railway will supply Track Charger, B - type choke, Resistance, battery, TLJB and relays from the stores at and are to be transported to site of work at contractor's cost. Tenderer shall supply any other materials that are required for the work.
Supply, transportation, fixing and execution of continuity bond for Glued Joints. The 11 contractor shall supply bond wire of 8-SWG, channel pins, drill twist of size 9/32" and any other materials to execute the work. The drilling machine, hammer, packing materials, lubricant and any other materials required to execute the said work shall be arranged by the contractor. The work will be carried out as per instruction of Site Engineer of Railway.
Transportation, Charging, installation, wiring of low maintenance Secondary cells as per manufacture's instructions and Railway's directive. This includes supply of distilled water and sulphuric acid by the contractor at his own cost. The un charged batteries with connector shall be supplied by the Railway. Materials including 3/0.29 PVC wires, battery connector , brass bolts and nuts , PVC tapes eyelets, etc and all other materials shall be supplied by the contractor. Note: [1] 12 Before completion of works contractor shall prepare jointly with Railway Engineer at site and submitt battery capacity test report as per approved format of Railway and hand over all relevant records to the Railway. [2] All the cells failing in the discharged capacity test in the Railway premises will be replaced by new ones free of cost. Railway Engineers decision shall be final. . Capacity test register ( binded size no. 10) in prescribed format shall be supplied by the contractor. In case of failure in capacity test tenderer will be responsible for fresh charging/replacement of the batteries. 2 Volts/80 AH
Supply, transportation, erection, and grouting of Composite Relay Racks / Relay Racks / CT racks as per Drg.No. SK/DRG/OL/SER/192, SH-1/2 (for Composite Relay Racks), Drg.No. SK/DRG/OL/SER/192, SH-2/2 (for Relay Racks) and Drg.No. S&T/CON/HQ/VSKP/95/92 (for CT Racks) respectively, including fixing of racks, PBT terminals 1-Way/6-Way, ND Fuses, Bus Bars, Eyelets, Hylum strips of required thickness [12 mm] as per length required at site, condensers and resistances etc., wherever required as per directions of Site Engineer. Inspection of Composite Racks / Relay racks/CT racks by Representative of Railway before use. Tenderer shall supply all the materials from RDSO approved sources such as PBT terminals 1-Way/6-Way, ND Fuses, Fuse blocks, Bus Bars, Eyelets, Hylum strips (12 mm thicknessn ISI Mark) condensers and resistances etc., and any other materials required for the work at his own cost.
Supply, transportation and fixing of MS ladder with suitable clamping arrangement & associated masonary and smithy work in Relay room, equipment room, Battery room, Goomties and 14 cabins etc. The MS ladder should be made of 1" X 1" (1/8"/3 mm thickness) and MS flat size of 1" wide X 1/8" / 3 mm thickness. MS flat shall be provided at every 8"apart. Width of ladder shall be 8". Tenderer shall supply all materials for this work. Inspection By representative of Railway before use. [RM=Running Meter] Note : Unit should be read as Running Meter
Wiring and testing of complete Relay Rack / CT Rack / Composite Relay Rack as per wiring diagram for maximum number of plug in type relay & shelf type relays of different sizes or as directed by Railway Engineers at site. This includes rack to rack wiring through MS ladder fixed on the top of the relay rack, crimping eyelets in the terminals fitted in the cables termination rack, numbering by ferrules 2.5 sq. mm, bunching of wires by bunching Tape/Thread and buttons, painting and lettering as required. Wiring of the racks shall be done with PVC wire of size 16/0.2 mm and 15 3/0.75 mm. Tenderer shall supply all wires & wiring materials purchased from RDSO approved sources. "Note: 1) Only relay and relay bases will be supplied by the Railway. Contractor has to supply all other materials for the above work and make arrangement for transportation of materials supplied by Railway at his own cost. 2) Only brass screws shall be used for fixing of relay bases. 3) All types of wires and wiring materials, eyelets of sizes (make: Dowell's or similar), ferrules (2.5 sq.mm), resin core solder, insulating tape, bunching belt & buttons etc. are to be supplied by the contractor. Wires will be procured from RDSO approved sources only. and all other components will be supplied by the contractor as per requirement at site."
Alteration of wiring in existing Relay rack/ CT rack/composite relay rack. This includes 16 supply of all types of wires, eyelets, nuts & bolts, bunching material, ferrules, ARA terminals, fuses & fuse blockes by the contractor at his own cost. Lettering & painting to be done by the contractor at his own cost. Wire (RDSO Approved Sources) to be inspected by the representative of Railway before use.
Transportation, installation, wiring, testing and commissioning of RKT on 20 mm pre- 17 laminated, BWP, termite proof, borer proof plywood (or on a 12 mm Hylum sheet ISI Mark) of size 300 mm X 400 mm X 12 mm per RKT, including termination of cable/indoor wire, LED, push buttons etc. Railway will supply only RKT. Tenderer will supply all other required materials for the work. Inspection of plywood/Hylum sheets by Representative of Railway before use.
Manufacture, supply, transportation and fixing of wooden box/MS box/Hylem board for terminating the power cable in Goomties, Relay room and any other places as instructed by site Engineer.
Painting, varnishing, numbering, lettering and graphiting of all outdoor and indoor 19 signalling equipments over and above the initial painting as per instruction of Railway representative at site. This includes supply of paints, varnish, graphites and any other consumables by the contractor. Note : Unit should be read as Lumpsum Station (LS/STN)
"Wiring, testing and commissioning of overall circuits and ground gears of approved interlocking arrangement as per approved circuit diagram and Interlocking plan. This also includes making corrections/alterations in As Planned drawings and documents as per the execution at site. This includes Free home signal connection at site and SM's office, telephone connection in the 20 tents/goomties and any other communication arrangement for the Non interlocking at the station or as decided by the representative of Railway during non interlocking. The materials required for preparation of Free Home indication board will be supplied by the tenderer.This also includes painting and lettering of gears. Telephone , VHF Sets/Walkie Talkie sets will be supplied by railway. Note: In case of IBS : It includes overall testing and commissioning of IBS and both the end stations associated with IBS modification." Note : Unit should be read as Stn./IBS
Maintenance of all the installation of PI/EI stations under an able and competent supervisor for a period of 30-days from the date the works of a station is handed over to the traffic and as per directive of Rly. Representative. This includes supply of minimum 5 Kg of grease, Lubricating oil of 5 Ltrs. for Point Machines, lubricants(black oil), distilled water , Cotton Waste of 5 Kgs and all other petty consumables for regular maintenance. "Note: (i) During maintenance period all sorts of repairing, replacement of defective gears, oiling, greasing, cleaning and transportation of materials required thereof shall be carried out in addition to regular maintenance works by the contractor. (ii) During maintenance period maintenance staff shall be provided by the contractor round the clock to assist Rly. Official as directd by Railway. (iii) During the above maintenance period contractor has to replace/repair any defect to the corrections of the fact pointed out by the Railway Administration at contractors cost without endengering Railway safety and safety rules. " (iv) During the above maintenance period contractor shall comply all the residual works and carry out petty repair works and attending failures promptly by keeping artisan staff who must be available round the clock.The contractor will supply, prepare and fill up all the required following registers: Cable Insulation Register, Track History Cards, Battery History Register, Equipment History Register, Signal Lamp Replacement Register, Joint P-Way & S&T Inspection register, Relay History Register, Diesel Generator Log Book, Point Machine Over-hauling Register, Relay Room Key Register, Seperate Register for Each Counters and any other registers and documents as per standard guide lines issued by the Railway time to time and as per directives of the Railway Administration. Contractor shall maintain all the records neatly and hand over all the registers and documents to the Railway Administration.During maintenance and for taking all the above parameters tenderer staff will work as instructer by Railway. Maintenance of 6 & above line station.
(b) Dismantling of the RCC structure of Signal & Loacation box or any other signalling structure by hydraulic breaker/Manual. This includes transportation and removal of debris from site as instructed by the Railway.
[g] Supply of soft copy in CD of station/Gate working rules with contractor's stationery, tools, plants and materials.
Supply and execution of Earth Leakage Detector 12 Channel as per RDSO specification No: RDSO/SPN/256/2002 or latest.Inspection by RDSO.
Supply and execution of Earth Leakage Detector 8 Channel as per RDSO specification No: RDSO/SPN/256/2002 or latest. Inspection by RDSO.
Transportation, Installation, testing and final commissioning of Data Logger Equipment in view of Up gradation of existing Data Logger with Scanner card and software as per RDSO Spec. No. 99/2006 or latest. The Scanner card and software will be supplied by the Railway.
Miscellaneous arrangement for NI period comprising of Provision of water-proof 30 temporary goomty/tent at both side of the station yard and at central panel building. Each goomties to be furnished with one iron table, six chairs, emergency light and mosquito repellent caps for NI staff, PA system, crowbar men for operating point and men for supplying water to tents. Note : Unit should be read as Stn./IBS
Transportation and jointing (straight through and derivation) of PIJF/quad cables size TSF-IV as per Specn No. IRS: TC-31/96 & IRS 30/97. Jointing kits shall be supplied by the Railway. All other materials shall be supplied by the tenderer.
Supply, transportation a n d Installation of 10/20/50 pair Aluminium CT Box and 32 termination of cables inside C.T. Box in station building cabin/office/quarters as per instructions of site Engineer. All materials like C.T. Box shall be supplied by the contractor at his own cost. Inspection by representative of Railway. This also includes painting and lettering of description.
Transportation of HDPE pipe from the store to work site, laying of the same (With 4 33 mm nylon rope, pre inserted inside the HDPE pipe) in excavated trench/ already laid GI/ RCC pipe / tubes, jointing, leveling and end sealing the pipes, HDPE pipe, couplers and end caps shall be supplied by Railway, Nylon rope shall be supplied by the contractor.
Transportation of OFC from the store of to work site with care, and pushing/ pulling OFC through the HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by 34 mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof. Per Block
End to end testing of all fibers of the optical fiber cable between station/ cable huts. This includes submission of test results in 4 copies as detailed in the technical specifications to be collected from the Railway. Note : Unit should be read as Section.
Supply, transportation, installation OFC termination box suitable for 19" rack mount as per RDSO specification no. IRS:TC:81-2000 part B with latest amendment, Splicing & deriving of 36 optical fiber cable inside the fiber termination box. All materials shall be arranged by contractor except optical patch cords which will be supplied by Railway. The OFC termination box shall be fitted on the wall using laminated board of 25 mm thickness suitable to accommodate 3 nos. of OFC termination box. Laminated board shall be fitted on the wall using clamps.
Supply ,transportation & installation of Optical Fibre cable joint enclosure and splicing of OFC (24 Fibre) and testing. OFC spicing shall be done in presence of Railway Representative.
Excavation of cable joint pit of size 1m x 1mx 1.2 in all types of soil for jointing of copper cables, back filling and ramming after jointing.
Cutting of Trench across /on Platforms with refilling and repairing the Platforms for concealed wiring for a depth of about 25 cm and width 10cm with marble cutting machine and filling the trench after cable laying and restoring the surface /trenching in non concrete area to depth of one meter.Refilling after cable laying and restoration the surface to normal condition etc.
Concealed wiring of cat-6 cable/telephone cable/ OFC cable in the PVC pipe/PVC channel by making groove in the wall, fixing the PVC pipe with clamps, nails and plastering and distempering to make it as it was earlier as per instructions of engineerin-charge.This includes laying 40 and fixing of allthe PVC pipes as per colour in systematic way as per instruction of Rly. Engg. at site. required for laying of all types of cables for railnet, telephone connection etc.,All the sundry items for the work has to be supplied by the contractor. Railways will supply telephone cables/Cat-6 cables and PVC pipe/channels. All the telecom cables will be drawn from the specified location , approved drawing.
Laying of OFC/Powercable/CAT-6 cable/ PACable/ Data cable and all the other types of telecom cable through HDPE pipe/casing capping /false ceiling with laying/fixing of HDPE pipe/casing 41 capping/PVC pipe for connecting/ interfacing various components and system integration. All materials for jointing and termination of power cable/CAT-6 cable as per site requirement are to be supplied by contractor. This item also includes supply of RJ-45 connector with cap for terminating CAT- 6 cable and (This includes releasing ofexisting cables, displayboards if any as per the instruction of Rly. representative at site)
Supply, installation, testing and commissioning of Train formation At A Glance display board with all accessories as per RDSO specification no.RDSO/ SPN/ TC/ 108/2019 Rev.0.0 with Amdt - 1 or latest. Inspection by RDSO.
Installation, testing and commissioning of PDC as per RDSO Specification No.RDSO/SPN/TC/ 108/2019 Ver.0.0 with Amdt 1 or latest as supplied.
Installation, Testing and Commissioning of Double Faced Coach Guidance Display Boards and daisy chain junction box in Open area including supply, erection & fabrication of pole, angles, fastening & rain-hood as per Technical instruction given in Section-H.
Installation, Testing and Commissioning of Coach Guidance Display Board and Daisy Chain Junction Box in covered area. All fixtures required for this purpose will be arranged by the contractor at his own cost as per Technical instruction given in Section-H.
Supply of Counter Communication system model no.CCS.-2300 (Ahuja make) or similar. Inspection by the representative of Railway.
"Supply and installation [splicing of fiber] of Rack Mount LIU 12 Core Loaded with SC Adaptors. Make: D Link or similar of reputed make. Inspection by the representative of Railway. "
Supply and installation of cablofil wire mesh cable tray as per detailed specifications. It should be of size 150 mm width and 54 mm depth Electro Galvanised type ( cat No. 000081 of legrand), fast couplers EDRN type (Legrand cat no. 558241) and Kitaster (Legrand cat no 558081) for 48 Joining two length, round corners and centre joint, wall mounting type accessories in GS material CSN for running the cable tray along with the wall (legrand cat No.556110)and Faslock for roundcorners (cat no 558347 of legrand)and equipped with Cover (legrand cat No 646030) equal to the length of the Cable tray and fixing clips for the cover (cat no 646200) and RCSN 200 (legrand cat no 13200) support for vertical mounting. Inspection by RITES.
Supply, installation, testing and commissioning of 2core screened/shielded multi strand PVC insulated wire [24/0.2mm dia.] for speaker load line. Inspection by the representative of Railway.
"Supply, installation, testing and commissioning of Single line Double Face train Arrival/ Departure display board as per RDSO specification no. RDSO/SPN/ TC/ 108/2019 Rev.0.0 with Amdt -1 or latest. Inspection by RDSO. "
Supply, transportation, installation, testing and commissioning of 55 inch or higher LED TV having 24 x 7 duty cycle with processing module as per Annexure-I. Necessary software to interface the LED TV with CDC to be provided by the contractor. The system should be intigrated with CDC for giving display. The system should be placed inside a suitable perforated metal casing having rain hood. Front of the TV should be protected with transparent polycarbonate sheet. Rain Hood of suitable design made of CRCA Sheet of minimum 16 SWG thickness shall be provided on the top of LED TV. All the materials required for installation of LED TV, local electrical sockets, plugs etc. will be supplied by the contractor. Inspection of LED TV before installation will be done by representative of Railway.
Supply and installation of Surface Mount Speakers similar to Make EV Model EVID 4.2t as per specification in section-H or better. Inspection by representative of Railway. (Unit: Pair = 2nos.)
Optical Fibre cable splicing and testing. OFC spicing shall be done in presence of Railway Representative
Supply, Installation and commissioning of On Line UPS 5KVA make 54 APC/Uniline,Indicative backup time 240Minutes (3200 VAH Minimum)with SMF batteries of EXIDE/AMCO/ SF/AMAR RAJA/AMRONwith suitable rack to beprovided for battery & UPS. Inspection by representative of Railway.
"Supply and Installation of double faced GPS based Digital clock as per RDSO Spec. No. RDSO/SPN /TC / 62 / 2008 Rev.3. or latest. Inspection by representative of Railway."
Supply & Installation of Professional 19" mount Equipment Racks 9U for housing telecom Equipment.Inspection by Representative of Railway.
Supply, transportation and installation of Horn speakerModel No. UHC 25 XT or similarof Ahuja /Studiomaster make.Inspection of speaker by representative of Railway.
Supply, Installation,Testing and commissioning of 2 MP HD IP Bullet camera as per RDSO spec with all accessories . Inspection by the representative of Railway.
Supply, Installation,Testing and commissioningof 2 MP HD IP Dome camera as per RDSO spec with all accessories. Inspection by the representative of Railway.
Supply, Installation ,Testing and commissioning of High Performance Enterprise Indoor 60 Access Point 2.4 Ghz & 5GHz dual band support 256 Concurrent user . Make and model : CISCO/RUKUS/Cambium/Cn pilot E400 Warranty : 3 Years with Centralized Wireless controller software capable of handling 4000 Acess points. Inspection by RITES.
Supply, Installation, Testing & Commissioning of 42 U Rack with PDU,FAN, loaded patch paneland other accessories asper detailed Technical Specification given in chapter 8 section-H of Tender document. Inspection by RITES. Above/
A3-Execution of Outdoor work
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including 02 transportation and laying of DWC/RCC/Split RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and 03 width 0.3 Mts. at the bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. to 1.0 mtr at places to be indicated by site Engineer for entering of cables inside the 04 building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.
"Trenching and fixing of G.I. pipes of different sizes/DWC pipes in hard rocky area up to a depth of 0.3 M to 0.6 M or at places as per instruction of site Engineer and concreting [1 : 3 : 6] up to height of 100 mm above the pipes. G.I. pipes with the socket/ DWC pipes shall be supplied by the 05 Railway. All other materials required for the works shall be supplied by the contractor. Note: [1] In case of girder bridges, G.I. pipes shall be suitably clamped by the contractor as advised by the site Engineer. Clamps shall be supplied by the contractor. [2] The work including excavation of trenches in hard rock area up to a depth of 0.3 M to 0.6 M and back filling, ramming after completion of work where ever required. [3] In case of concrete bridges clearing of ballast for laying of pipes and re arranging the Railway ballast after completion of work shall be done by the contractor.
Laying of Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with left 06 over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
Excavation of trenches including clearing of roots of trees etc. in rocky areas with 07 chisel cutting up to a depth of 0.6 M and width of 0.3 M at the bottom. This includes concreting (1 : 1.5 : 3) at a height of 100 mm after laying of cables as per instruction of site Engineer and back filling of trench by digging. All materials including cement and chips of size 20 mm. etc. to be supplied by the contractor.
Transportation, excavation of pit, casting of foundation, plastering and erection of 08 Steel Apparatus case (full size) with fixing of E-Type lock, wiring, cable entry, termination clamping, filling cable pit with sand, painting and lettering etc., as per Drg.No. S&T/CON/SK/16. This includes earth work and/or masonry work required for securing the apparatus case as per site condition. Railway will supply apparatus case with 'E' type lock only from Railway stores at. Tenderer will supply all wiring materials, PBT Terminals, fuses, fuse blocks, bus bars, hylum sheet ISI mark [6mm thickness], wood plank board of good quality [minimum 3/4" thick, Cement and transport all the materials to site of work at his own cost. The wiring materials such as wire coils, PBT terminals, fuses, fuse block, etc. should be used from RDSO approved sources. "1) Modifiaction of inside arrangement of Apparatus cases if required for fixing of relays/transformers etc. shall be done by the contractor. Extra shelf, if any, shall be deposited to the Railway stores by the contractor. 2) All cables shall be terminated by providing copper eyelet of suitable size." Note:-(i) If location box foundation is available at site 20% of the cost is to be deducted.(ii) 40% payment shall be released after erection of location boxes.
"Supply, Transportation and Installation of earth electrode (make TATA or Jindal as per Rly. practice) including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rcak, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as 09 per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat (make TATA/Jindal or Similar) to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) NOTE: This includes testing of earth value and indicating the same on the Earth enclosure by paint.
Transportation of Position Light Shunt Signal complete with post, units, bases and 10 other fittings; excavation of pit, casting of concrete foundation (1 : 3 : 6) as per Drg. No. CON/SK/T/13, complete fittings of signal including termination of cables, wiring, focusing and testing. Railway will supply position light shunt signal with base from store. Tenderer shall supply all other materials required for the work.
Transportation of signal posts for multiple aspect color light signals, complete with signal units, bases, ladders and other fittings, excavation of pit, casting of cement concrete foundation, plastering as per Drg.No Con/SK/T/12, erection and fixing of complete fittings of the 2/3/4 aspect signal/signal posts including termination of cables, wiring, LED fixing, signal testing and 11 focusing. Name plate & marker and all other materials shall be provided by the contractor at his own cost. Required cement shall be supplied by the contractor. Arrangement of Screening to be provided by the contractor if required as instructed by site Engineer. Contractor shall prepare jointly with Railway Engineer at site and submit Signal Sighting report and Signal test report as per approved format of Railway. NOTE: (i) 50 % Payment shall be released after erection of signal post. Balance 50 % shall be released after termination of cable, wiring, painting, testing & focusing of signal. (ii) If foundation is available at site 30% of the cost is to be deducted.
Supply, transportation, foundation, erection, painting and lettering of SLB/BSLB, warning/sighting board of standard size etc, with 6" (minimum) G.I channel iron support of 12 appropriate length as per G&SR, SEM and IP. This includes excavation of pit as per approved drawing of the railway for casting of foundation (ratio 1 : 3 : 6). All the materials required for above work shall be supplied by the contractor. Note: SLB/BSLB shall be fitted with ladder as per standard practice. Inspection of SLB/BSLB, warning board by the representative of the Railway.
Concreting (Mix 1:2:4) 200 mm x 200 mm on G.I. Pipes on bridges/ culverts or any other location as specified by the Rly. supervisor. All materials including cement required for the above works are to be supplied by the tenderer.
Concreting (1:1.5:3) at a height of 150 mm & width of 0.3 m after laying of cables 14 where it is not possible to dig up to full depth of 1.2m/1.0m/0.8m in normal soil due to existing cables are in the trench, culverts, bridges. All materials including cement and chips of size 20mm. etc. to be supplied by the contractor. Payment for the depth of trench to be paid in proportionate to the rate specified for 1.2 mtr depth (excluding the concreting rate).
Supply, transportation, and installation of RCC joint chamber with two piece top cover 15 and bottom cover with hole for drainage and cable entry as per drawing No.RCIL/ER/DRG-02/06 (Section-H). This includes trenching for joint pit, back filling and ramming of pit after placing the joint closure and cable loop in the chamber without causing damage to the same and consolidation of soilas well as disposal of excess soil.
Supply, transporting and positioning of good quality full bricks length wise inside the trenches for separation between Signalling and power cable at the @ 04 [Four bricks] per meter.
Entry and Termination of cable, wiring, painting, testing & focusing of signal 2/3/4 aspects in existing signal posts. Name plate & marker shall be provided by the contractor at his own cost. All materials for wiring and termination of cable to be supplied by the contractor.
Massonary chase cutting 3/2" X 3/2" at work site plastering of PVC pipe in the chase, drawl of 2/5/10/20/50 pair switch board cable through it, covering and plastering the chase with contractor's cement. All materials required for the work are to be supplied by the contractor.
Horizontal direction drilling/boring without damage of surface of road/track formation. The bore shall be 150 mm dia. and shall be at the proper depth as per site conditions decided by Enginer-in-charge. The ground level shall be considered ignoring the bankheight of the bank of the 19 road. The length of the bore shall be minimum 04 Mtrs long. This include insertion of different dia. DWC/GI/HDPE pipes coupling etc as per direction of Engineer-in-charge. NOTE: The cost of pipe is not included in this item. Contractor shall provide all material required for boring and adequate nos. of labourers for proper laying of cables in to the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling and pressure on cable.
A4-Fire Alarm System Supply & Execution Schedule (Note: Item No. Above/
Supply, Installation, Testing & Commissioning of Networkable Single loop addressable Fire alarm Control panel expandable upto 2 loops & interface with GSM/LTE module working as per RDSO/SPN/217/2021 ver-3 or latest. The control panel shall be networkable to Zonal /Divisional Headquarters preferably over TCP/lP and shall have clock synchronization facility. This schedule includes supply of TCP/IP converter/ Networking card. The control panel shall have provision of Graphical software to enable remote monitoring of entire fire detection and alarm system of a station from Head Quarters. The control panel shall be designed to work on power supply of 110V/230V AC as well as on DC battery backup of adequate capacity to work upto 24 hrs. Backup. The Power supplies 01 like batteries and chargers shall be supplied by the contractor. The Control Panel shall have means for the user to visualize and interact with the complete Automatic Fire Detection and Alarm System layout through a user-friendly software executable on a standard Windows based Personal Computer. It shall be possible to download data and extend alarms from Control Panel through suitable ports like RS485/RS232/USB/TCP/IP into a PC/Laptop available with SSE at the installation and remote location (Divisional Control room) operating on Windows platform. The software for downloading and analysing fault data shall be provided & shall be compatible with the latest windows operating system. Detection, actuation, and control system shall have provision for automatic as well as manual operation. The GSM/LTE module for interfacing with Control panel duly providing compatible SIM with SMS facility on minimum of 5 numbers (users) and all other accessories. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation ,testing and commissioning of single channel laser or High power LED based Aspiration detection unit ( for AC room) with area covering 5000 sq. ft. with programmable 4 stage alarm generation and with 4 addressable modules. It should have auto cleaning facility in 02 optical chamber, electronic discrimination of particle size, ultrasonic air flow sensing auto learn feature with TCP/IP network capability, the aspiration system shall also include external power supply unit with battery backup. Approval-UL/LPCB/VDS listed and shall comply to specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation testing & commissioning of Heat and smoke multi sensor with back box with integral short circuit isolator as per specification No. RDSO/SPN/217/2021 ver-3 or latest and 03 required to be provided at suitable locations inside the diesel generator room, battery room, ASM room, and other S&T service rooms as directed by the Railway site Engineer. The location of fixing is to be meticulously decided so that full advantage of the system is achieved. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation and Testing, commissioning of Audio Visual alarm (Hooter and strobe) with back box controlled through addressable control model. Visual Alarms (Strobe): It shall be 04 preferably flashing type RED/WHITE Color. Audio Alarms (Hooter): It shall be preferably with Piezoelectric type sounder. The sound level shall be preferably adjustable type up to 90dB at a distance of 1m as per specification No. RDSO/SPN/217/2021 Ver - 3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation and Testing, commissioning of Analogue Addressable and resettable Manual call point with back box with integral short circuit isolator, Analogue addressable 05 protocol having status LED for alarming & standby mode, Binary coded dip switch addressing. It shall have inbuilt fault isolator or alternate arrangement which shall isolate the Manual Call Point in case of open/short circuit fault within it as per specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, Testing and Commissioning of Analogue Addressable type Isolator 06 modules device for isolating in case of any fault, complying to the RDSO/SPN/217/2021 ver-3 or latest. Inspection by Rep. of Railway Engineer. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing and Commissioning of Relay module with back box and all other accessories as per RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, testing and commissioning of Monitor module with back box and all other accessories as per RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, testing & communication of Linear Heat Sensing (LHS) Interface 09 module with all accessories for integration with main line fire alarm control panel as per RDSO specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation Testing and commissioning of Analogue type Linear Heat Sensing 10 cable with required module to be integrated on main Fire Alarm Panel as per specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing, Commissioning of Auto Telephone Dialler (GSM) Module to 11 send the pre-recorded message (fire and fault massage) to multiple mobile numbers, programmed earlier, complying to the RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15
Supply Installation, Testing, Commissioning of Power supply System 24 V/2 Amp with built in Charger with battery backup as per specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation Testing and commissioning of FRLS/Fire Survival Circuit Integrity 13 Cables and power cable with all accessories for connection of Fire Alarm devices specification No. RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, Installation, Testing & Commissioning of UL/LPCB/VDS listed CPVC Pipe with 14 suitable diameter as per requirements & pipe accessories for the Aspiration detection shall comply to RDSO/SPN/217/2021 ver-3 or latest. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply, installation, configuring, testing and commissioning of remote monitoring 15 software (GUI) along with license for Min. 20 addressing control panels with license as per RDSO/SPN/217/2021 Ver-3.0 or latest. This includes necessary gateway card and network interface card for the system fully functional as desired by railways. Spares cost are also included & to be supplied as per RDSO para no. 4.15.
Supply & Insttallation of CO2 Fire extinguisher 4.5 kg capacity confirming to IS 15683: 2018 or latest with ISI mark provided with all fittings and accessories. Inspection by representative of Railway.
B1-EI Supply Schedule (For EI alteration of M/S WESTRACE MK2)
Supply of additional materials required for the modification of EI. Items of vital materials like cards, modules will be inspected by RDSO. Above/
B2-Supply Indoor & Outdoor Materials Schedule
Supply of Shunt Signal Position Light, ground type independent complete as per RDSO Spec No. RDSO/SPN/153/2011 with base, hoods, number plate, Post wire mesh, post to Drg. No. SA- 23840 (Adv) latest for shunt signal, SA-23202 for base, IRS:S-6/81 for post. Inspection by RITES.
Supply of Shunt Signal Position Light, dependent post type complete as per RDSO Spec 02 No. RDSO/SPN/153/2011 with offset bracket 90 mm dia to suit 140 mm dia post to Drg. No. SA- 23840(Adv.) with latest amendments for shunt signal & SA-23040/M for offset bracket 90 mm. Inspection by RITES.
(c) Supply of Signal colour light multi unit as per specification No: IRS: S-26/64 with 04 latest amendment as per RDSO Spec No. RDSO/SPN/153/2011 long range working on 110 V- AC 50 Hz complete 2-Aspect suitable for 140 mm dia. post as per Drg.No:SA-23003 A/M [Adv]. Inspection by the RITES.
Supply of 4.6 Mts CLS tubular steel post specification No. IRS: S-6/81 with latest Amnd to suit 140 mm dia base. Inspection by the RITES.
Supply of Signal Base 140 mm dia [Type tube] Drg. No. S-2011/M. Inspection by the RITES.
Supply of Ladder 4.5 meter for CLS post as per Drg. No. SA: 23153 [Adv] Alt-1, specification No. IRS: S-10/78 (with latest Amendment) consisting of ladder base, platform and guarding, ladder support complete. Inspection by the RITES.
Supply of Bracket Off set 140 mm outside dia. for colour light signal post as per IRS:S- 10-78 and Drg.No:SA-23080. Inspection by the RITES.
Supply of Track lead junction box made of glass fibre reinforced plastic Drg. No. SI- 10272, Alt-C, specification No. RDSO/SPN/151/1997. Inspection by the Representative of Railway.
Supply of Track feed resistance 30 Ohms [2,4,8,16 Ohms] Drg, No. SA-20161- 66 /M and Spec IRS:23/88 (with latest amendment) with PBT base. Inspection by the Representative of Railway. Track feed resistance should be supplied from only RDSO approved sources.
Supply of Track feed battery charger input 110VAC, 50 +/-2 Hz with boost and trickle charging for 1 to 4 cells of 80AH, 10A capacity as per spec. No: IRS:S-89/2013 Ver. 1 or latest. Inspection by RDSO.
Supply of Choke coil type-B, impendence 120 Ohms and resistance 3 Ohms DC [For feed end and Relay end], specification No. IRS: S-65/83 Amnd. 3 or latest. Inspection by RDSO.
Supply of low maintenance lead acid secondary cells of capacity 2 V - 80 AH with nuts, bolts, interconnector, ceramic vent plug, battery float etc. Specification No. IRS: S-88/2004 with latest amendment with connectors, nuts, bolts, vent plugs, etc. Inspection by RDSO.
Supply of Relay AC Immune, plug-in type, style 'QNA1', Neutral line, 24V DC 8F/8B 14 contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS:931A,IRS: S - 60, IRS: S - 34, IRS: S-23 (As applicable). Interlocking code: ABDGH. Inspection by RDSO.
Supply of Relay AC Immune, plug-in type, style 'QNA1', Neutral line, 24V DC 12F/4B 15 contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and connectors conforming to BRS:931A, IRS S - 60, IRS: S - 34, IRS: S-23 (As applicable). Interlocking code: ABDFH Inspection by RDSO.
Supply of Relay AC Immune, plug-in type, style 'QSPA1', DC, Neutral line, slow to pick 16 up, 24V DC, 8F.4B contacts, Front and back contacts metal to carbon, complete with plug board, retaining clip and copper annealed connectors conforming to BRS:933A, IRS: S - 60, IRS: S - 34, IRS: S- 23 (As applicable). Inspection by RDSO. Interlocking code: ABDEJ
b] Supply of Relay Non-AC immune, plug in type, style QN1, neutral line, 24V or 50V DC, 12F/4B contacts metal to carbon with plug board, retaining clip and connectors confirming to BRS: 18 930, IRS: S-34 and IRS: S-23 (As applicable). The interlocking code for this unit shall be ABCDE for 24V and ABCEF for 50V. Inspection by RDSO. NOTE:- Depending upon the EI System, the operating voltage of the relay may change. Accordingly the quantity of relays of different operating voltage needs to be approved by railways on request of the OEM of EI System. The contractor shall supply the compatible relays at the same rate.
Supply of Relay Non AC Immune Plug in Type Style QL1 magneticaly latched, Neutral 19 line 24 V DC , 11 F/4B Contacts metal to carbon , complete with plug board, retaining clips and copper annealed connectors conforming to BRS :935A, IRS-S - 34, IRS;S-23. Interlocking code: ABDEG. Inspection by RDSO.
Supply of Relay plug-in type Point Contactor relay AC immune plug in type style QBCA1 DC based contactor ,24 V DC with 2 HF ,4B contacts, Heavy duty metal to carbon front 20 contacts and back contacts metal to carbon, complete with plug board retaining clip and connectors confirming to BRS: 943, IRS S - 34, and IRS S -23. Interlocking code for this unit shall be BCEJK. Inspection by RDSO.
Relay plug in type , Style AC-LED: ALL aspect, AC lamp proving Relay unit with in built 21 current transformer type, slow release neutral line relay, 4F/4B contact , front and back contact metal to carbon shall be suitable for working in series with 110V AC, LED signal lamp rated at 15W conforming to RDSO Spec No- STS/E/Relay/AC lit LED/signal/09-2002, Amdt. 1, BRS:941A, IRS:S:34 & IRS:S:23 {as applicable}. The interlocking code for this unit shall be ABDHK. Inspection by RDSO.
Supply of Fail safe "Q" series electronic timer of 120/60 Sec. As per requirement of Railway (plug in type) as per Specn. No. IRS:S-61/2000, Amd-2 or Latest . Inspection by RDSO.
Supply of Electric key transmitter with different key ward as per requirement as per Drg.No. SA-22601 [Adv], Alt-4 for rotary key transmitter, SA-3577 (M) for Key and IRS:S:21/01. Ward No shall be specified by Railways. Inspection by RDSO
Supply of Steel Apparatus case 'large Size' as per Drg. No - CON/SK/1/1/86 and Spec.No. IRS:S-10/78 (adv) with latest amnd. with "E" type lock and key of ward No-32 with handle. Inspection by RITES.
Electric point operating machine 143 mm non trailable to operate on 110V DC complete with lock, detector, Point Junction Box along with telescopic pipe and slides for lock and 25 detector - rotary locking Universal type as per specification No: IRS/S/24/2002 with latest amendment Drg. No. RDSO/S-10800 and IRS : S-37/82 Amdt. 3 with Drg. No: RDSO/S: 10910 for motor along with standard tool kit set for every 4 point machines & PBT [6-way] Terminals for Junction Box. Inspection by RDSO for all items except PBT 6 way terminals which shall be inspected by Representative of Railway. NOTE: Tool kit shall be supplied in a suitable tool box.
Supply of Ground connection set complete suitable for rotary locking type IRS Electric Point Machine as per Drg. No S-3361-62 for 60 Kg rail with insulating materials as specified in IRS/S/24/2002. Inspection by the Representative of Railway.
Supply of junction boxes with covers and terminal plates 24/30 way to suit Drg. No- 23967/1 (as amended up to date) and IRS: S-10/78. This includes supply of PBT terminal. Inspection by the Representative of Railway.
Supply of Surge protection Devices complete with all accessories, fixtures as per the 29 following description as per given in Chapter -8 of Section - H. Inspection by RDSO. [a] Surge protection Device for 110V AC input to signals complete with connected wire as per technical specificition No:RS-SPD-7 .
Supply of Data concentrator along with one dual card modem, high speed dual port E1 to RS232 converter card, Dual port RS232 to OFC media converters (05 nos), patch cords of 15 mtrs length (12 Nos) for media converters and USB to RS485 converter. Inspection by RITES.
Supply of CMU/maintenance console (computer and printer) as per following 31 configration: PC make Dell/HP/Lenovo with 10th generation or latest Intel (R) Core i3 - processor (3M Cache, 3.6GHz) or latest, 4 GB single channel DDR3 1600MHz - 1DIMM, 500 GB 7200 rpm SATA 6Gb/s Hard drive, Windows 10 Professional or latest with Microsoft office, Monitor 20" (19.5 Inch VIS), E2014H, DVI/VGA, Intel (R) HD Integrated graphics Video card, 16xCD/DVD burner (DVD +/- RW) write to CD/DVD, 32 GB pen drive, UPS with minimum 6 hours battery backup for central monitoring unit, Quick heal total Security antivirus or similar 24 month subscription, EM (ROA) NMDL Software module, 3Nos Serial ports. Printer: make EPSON M100/HP laser jet 1020 plus or similar. One year site service warranty in Computer and Printer. Inspection of CMU by RDSO. This also includes supply of one set of computer table and chair (Make Godrej). Inspection of table and chair by Representative of Railway.
Supply of Work station for data input, configuration, simulation, functional testing, 32 diagnostic and trouble shooting for commissioning of EI system. Work station shall be capable of reconfiguring the system in case of any alterations in the yard or in the interlocking in the future. Backup software should be given in CDs. The technical specification of work station is as given in Section-H , Chapter-08. Inspection by the Representative of Railway.
Supply of PPTC (Polymeric Positive Temperature Coefficient) resettable fuses with 2 A, 120V AC ratings of Raychem RPG make or better. Inspection by the Representative of Railway.
PPTC 3A/120V AC. Inspection by the Representative of Railway.
Supply of PPTC (Polymeric Positive Temperature Coefficient) resettable fuses with 3 A, 60V DC ratings of Raychem RPG make or better. Inspection by the Representative of Railway.
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 36 mm inner dia, with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for under ground cable protection . Colour-Orange. Inspection by RITES. Note: If required, the DWC pipe shall be supplied split in two halves.
Supply & Uploading of software for upgradation of Datalogger as per Spec. No. IRS:S- 99/2006.Inspection by Representative of Railway.
Integrated LED Signal for RED aspect as per RDSO Specification No. RDSO/SPN/199/2010Rev1.1 or atest. ( Warranty Period : Upto 60 months from the date of supply) Inspection by RDSO.
Integrated LED Signal for YELLOW aspect as per RDSO Specification No. RDSO/SPN/199/2010Rev1.1 or atest. ( Warranty Period : Upto 60 months from the date of supply). Inspection by RDSO;
Integrated LED Signal for GREEN aspect as per RDSO Specification No. RDSO/SPN/199/2010Rev1.1 or atest. ( Warranty Period : Upto 60 months from the date of supply). Inspection by RDSO;
Supply of Calling-On LED signal Lighting 110 Volt AC retrofitable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No.RDSO/SPN/153/2011 [Rev.4]. (Draft) up to date if any.Inspection by RDSO;
Supply of ROUTE LED signal Lighting 110 Volt AC retrofitable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No.RDSO/SPN/ 153/ 2011 [Rev.4.1](Draft).Up to date if any. Inspection by RDSO;
Supply of Shunt LED signal Lighting 110 Volt AC retrofitable in existing CLS housing compatible with AC LED ECR as per RDSO Specification No.RDSO/SPN/ 153/ 2011 [Rev.4.1]. (Draft) up to date if any Inspection by RDSO;10
Supply of Magneto Telephone Desk type to Specification No. IRS: TC-36/97 amd 2. or IRS:TC 79/2000 Amdt. 4 as per Railway requirment. Inspection by the Representative of Railway.
Supply of Thermo shrink jointing kit for underground cable as per Specn No. IRS: TC- 45 77/2012 [Rev.3] Amd 3. (Cable jointing kit shall be procured from RDSO approved sources only). Inspection by RDSO.
Supply of 20 pair Aluminium CT box to spec No- IRS:TC 18/75. Inspection by the Representative of Railway.
Supply of Emergency socket box of FRP Material approved type complete with 6 pin way female pin as per RDSO Spec. No. RDSO/SPN/TC/44/2002 Ver. 2 Amd 3 or latest amendment. Inspection by the Representative of Railway.
Supply of multi strand (Red and black) insulated copper 7/20 mm wire. From RDSO Approved firm. Inspection by the Representative of Railway.
"Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner 49 dia 33 mm with three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. RDSO/SPN/TC/45/2013.Rev.2.0 Amendment 2.0 or latest. Inspection by RITES. Note: The HDPE Duct should be pre inserted with 4 mm nylon rope, inside the HDPE Duct."
Supply of OFC patch cord of 10 mtrs length as Draft RDSO Specn. No. RDSO/SPN/TC/69/2007 or letest for connecting fiber to the equipment. Inspection by the Representative of Railway.
Supply of Digital multimeter Fluke-287 or latest higher version with testing lead complete with case and spare set of batteries. Inspection by the Representative of Railway.
PVC Switch board cable 20 pair/0.5mm,as per TEC Spec No- GR/WIR-06/03, MAR-2002 with latest Amendment. Inspection by the Representative of Railway.
PVC Switch board cable 10 pair/0.5mm,as per TEC Spec No- GR/WIR-06/03, MAR-2002 with latest Amendment. Inspection by the Representative of Railway.
Supply of optical fibre joint closure for straight through joint with modification for 24 fibre as per RDSO Specn No. RDSO/SPN/TC/68/2014, Revision 0.1 Amnd. 1 or latest. Inspection by the Representative of Railway.
Supply of AC/DC Digital clamp meter, KOICO 3.5 digit Backlit LCD Hand Held True Rms. Inspection by the Representative of Railway.
Supply of Digital Earth Tester to measures Earth Resistance and Earth Voltage KOICO 5600 make. Inspection by the Representative of Railway.
Supply of Insulation resistance tester 500V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by the Representative of Railway.
Supply of Insulation resistance tester 100 V DC 500 Mega Ohms hand generator type metal body to Spec. no. IS:2992 make WACO. Inspection by the Representative of Railway.
Supply of High Power, Electronic Cable Route Tracer/ Pipe and Cable locating kit with Active multi frequency options including 200Hz, 512Hz, 797Hz, 815Hz, 8kHz, 33kHz, 65kHz, 82kHz, 200kHz passive detection @ 50Hz for power cables, Radio Mode for locating metallic utilities whether 59 energised or not, Current measurement, LCD Display with left-right arrow function , Modes: peak, peak with arrow, pin point peak and null modes, Compass function; Depth measurement. Supply includes locating receiver, Transmitter (Max power : 12Watt) with Li-ion Rechargeable Batteries for both Transmitter & Receiver, Battery charger, Induction Signal Clamp 4'', supplied in a carry bag. Similar to 3M-Dynate/Radio detection/Stanlay Pathfinder LOC10. Inspection by RITES.
Supply of 19" 12U rack wall mount type. Inspection by the Representative of Railway.
Supply of Double Face Coach Guidance Display Board with accessories as per RDSO/SPN/TC /108 /2019 Ver 0.0 Amdnt 1.0 with latest amendments, Versions. Inspection by RDSO;
Supply of Platform Data Controller (PDC) conforming to System requirement of RDSO Specification No.RDSO/SPN/TC/108/2019 Ver.0.0 Amdnt 1.0 with latest amendments,Versions. Inspection by RITES
Supply of PVC insulated flexible 3 core x 2.5 sq.mm multi strand power cable as per specification no. IS:694:1990 reaffirmed 1995 or latest. Inspection by Rep. of Railway
Supply of STP/UTP CAT-6 Cable of 305 Mtr box as per the requirement. Inspection by Representative of Railway.
Supply of PVC conduit pipe rigid plain ended conduit size 1 inch (25 mm) 1S:9537(part-3) and 9537 (Part-1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & one socket at every 3 meter pipe. (Inspection by representative of Railway.
Supply of OFC single mode 6 fiber armoured cable of makefinolex/Polycab/Paramount. (Inspection by representative of Railway.
Supply of public address amplifier solid state of capacity 500 watts (RMS) output The 67 amplifier shall be of type SSA 5000 EM of Ahuja make or Shure OR Bosch OR Studio Master OR Ahuja or Philips or latest version. Details conforming to clause No 4.6 of Part IV in the tender document. (Inspection by representative of Railway.
Supply of GPS based-digital clock office type as per RDSO specification no.- RDSO/SPN/TC/47/2008 rev 3.0 or latest make/brand- Autolite or Similar as per TS. (Inspection by representative of Railway.
Supply of Layer-2 Switch (minimum 8+2port manageable) with 8 nos.10/100/1000 69 Mbps Ethernet port, PoE and 2 nos. 1000 BaseX SM SFP port withoptical modules complete with allaccessories etc. as per RDSO spec. No:RDSO/SPN/TC/65/2021 Rev 6.0 or latest,Clause 14.0(iii). Inspection by therepresentative of Railway.
Supply of 24 Port 10/100/1000 Mbps Layer 2 managed POEswitch with minimum 1 combo SFP. Make: HP ARUBA 2530 24G-POE+switch or similar. Inspection by authorized Railway representative.
Supply of CAT-6, 0.5 Meter Patchcord. Make: Dlink/ Digisol/Molexorsimilar. (Inspection by representative of Railway.
Supply of fiber optic patching cord (05mtrs length) FC-FC/FC-PC/FC-SC/LC-SC/LC-LC duplex as per site requirement/site engineer. (Inspection by representative of Railway.
Supply of HDPE pipe of 110 mm dia, Pressure rating: PN 10, Material grade: PE 80 and wall thickness:10.0 to 11.1 mm, colour: Black with blue stripes confirming to spec IS 4984:1995 and latest. Coil length: 100 Mtrs. Inspection by RITES.
Supply of Indoor cable, 40 x 1 x 0.6 mm Dia. Material to be supplied from RDSO approved/proven source. Inspection by RITES.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .