Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Lowest Bid L1 rank competitive and reasonable during Scrutiny |
| 2 | L2₹1.7 Cr+₹30.9 L (22.8%)Rejected-AOC | ₹1.7 Cr+₹30.9 L (22.8%) | L2 | Rejected-AOC Not lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Two class below the eligible class |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
14 Nov 2022, 6:00 pmClosed
CWE
CWE AF BAMRAULI
IMPROVEMENT TO WATER SUPPLY INFRASTRUCTURE AT AF STATION BAMRAULI
2022_MES_536103_2
87200/C/E8
Open Tender
Civil Works - Water Works
Item Rate
182 days
BAMRAULI ALLAHABAD
Class B category a ii and other criteria as per NIT
9 documents required · 9 mandatory
₹1,000
GE AF BAMRAULI
₹2.6 L
Yes
11 Jan 2023
17 Oct 2022
21 Nov 2022
17 Oct 2022
14 Nov 2022
31 Oct 2022
17 Oct 2022 - 20 Oct 2022
Amount
Surface dressing not exceeding 15 cm and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes each not exceeding 0.5 Cum in soft/loose soil , getting out and removing surplus soil to a distance not exceeding 50 metre and making good surface. Note :- PCC for filling shall be measured and paid for separately under respective item of this schedule.
Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point.
Material and labour sand cushioning in with clean dry unsheathed gently punning around cable for protection complete all as specified and directed.
Material and labour provide, plain cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregate) as in mass concrete, sub base and foundation etc complete all as specified and directed.
Material and labour provide, plain cement concrete 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) as in mass concrete, sub base and foundation etc complete all as specified and directed.
Supply only liquid integral water proofing compound.
Material and labour provide plain cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping, hold fasts, cills etc including necessary form work complete all as specified and directed.
Supply and lay sub class ‘B’ bricks (old Size) ,common burnt clay building bricks for cable protection laid length wise perpendicular to the axis of cable, abutting each other gap should not be more than 10mm.
Taking down wooden Windows/Doors chowkats or frames not exceeding 1.5 sqm each (without taking off shutters from the frames) including making good for fixing new frame. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion.
Taking down wooden Windows/Doors chowkats or frames exc 1.5 sqm but not exc 4 sqm each (without taking off shutters from the frames) including making good for fixing new frame complete all as specified and directed. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion.
Supply and fix 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc including teak wood beading on all edges complete all as specified and directed. Note :- Thickness of beading for hinge sides shall be 25 mm and on other three edges 6mm thick. (ii) Builder hardware shall be measured and paid for separately at supply only.
Supply and fix Solid PVC door frame size 50mm x 47mm made out of 5mm plain colour (wood grain finish) PVC sheet reinforced with M S square tube as per specification and drawing on page No. 160 of MES SSR Part-I complete all as specified and directed.
Supply and fix Factory Made Solid PVC Moulded door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelaminated PVC Sheet on the front face and 2mm prelam PVC sheet on back face, as per specification and drawing in SSR Part - I complete all as specified and directed.
Supply only Aluminium, anodised, barrel tower bolts of extruded section size 200 mm long complete all as specified and directed.
Supply only extruded Aluminium, alloy handles of fabricated type of size 150 mm long complete all as specified and directed.
Supply only 300 mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Supply only 100mm size mild steel butt hinges with mild steel medium weight cold rolled complete all as specified and directed.
Supply only 100mm size extruded alu minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
Supply only Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn spring, (overall length of cover plate) 140mm complete all as specified and directed.
Material and labour mild steel framed work such as grills, grating etc with ends of bars shoulded, framed guard bars and similar work conforming to Fe-290 Gde E-165 fixed to frame with screws complete all as specified and directed.
Material and labour mild steel framed work such as grills, grating etc with ends of bars shoulded, framed guard bars and similar work conforming to Fe-290 Gde E-165for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, with screws complete all as specified and directed.
Mild steel work as post and strut in fencing including cutting tops to shape as directed drilling holes, notching for wire etc Flat iron strip for securing chain link fencing with angle iron post etc including all necessary drilling, bolting or riveting etc. conforming to Fe-290. Note :- Excavation in post holes, PCC & chain link fencing shall be measured and paid for separately under respective items of this schedule.
Material and labour mild steel TMT bars 10 mm dia, and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking, ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material and labour Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete, as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm long, diameter of neck exceeding 12 mm and not exceeding 15 mm.
Material and labour 1.25 mm thick pressed steel frames of size 105 x 60 mm and for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete, as specified and directed.
Supply and fix steel window with side hung shutter with box type hinges, steel peg stay, lugs, steel handles, with glazing bars dovetailed or welded complete including one shop coat of red oxide primer complete all as specified and directed.
Supply and fix steel ventilator with top hung shutter including hinges, steel peg stay, lugs, complete including one shop coat of red oxide primer complete all as specified and directed complete all as specified and directed.
Supply and fix Chain link fencing 3.00 mm dia GI wire, 50 x 50mm mesh to angle iron post including provn of binding wire etc complete. Note :- (i) Angle iron post, fillet, line wires and bolts for fixing chain link shall be measured and paid for separately under repective item of this schedule. (ii) Weight of chain link fencing shall be ascertain at site based on actual weight through Board of Officers to be conveened by GE.
Supply and fix Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Material and labour 0.63 mm thick mild steel, plain, black sheet in n hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and directed.
Material and labour 1.25 mm thick steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type complete all as specified and directed.
Taking down the cover of existing rolling shutters of gear / manual operated type (area of shutters not exceeding 11 squaremetre) carefully and complete overoiling the shutter by applying grease, lubricants etc in bearings springs guide channel operating rod etc smooth and free operation and refixing the cover back in the same position complete all as specified and directed.
Material and labour cleaning the roof surface (padding) from dust/dirt and provide water proofing treatment using APP based polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt including screed bed, tack coat, cement concrete tiles etc with the following operations :- (a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with liquid water proofing compound as per manufactures instructions when concrete is still green (PCC padding) complete all as specified & directed (Note - WPC shall be measured and paid separately). (b) After the plaster is fully dried cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. (c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer. (d) Over hot bitumen laying polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/150 mm end lap on prepared surfaces and under strict supervision of manufacturer’s technical representative & sealed complete all as specified & directed. (e) Cement concrete tiles 20cm x 20cmx20mm thick machine pressed, set jointed with grey cement and no pigment pointed in neat cement slurry over roof slab cut and polished including 20 mm thick screed bed in cement mortar (1:4) mixed with water proofing compound as per manufacturer instructions or @ 100 ml per bag of cement. (Liquid Water proofing compound shall be measured and paid in respective item of this schedule at supply only). (f) Water proofing treatment shall be carried out through authorized applicators only. (g) The work shall be carried out strictly as per manufacturer’s instructions.
Material and labour 75mm thick plain cement concrete 1:3:6 type C2, (using 40 mm graded crushed stone aggregate) as in sub base / plinth protection etc complete all as specified and directed.
Material and labour 25 mm thick plain cement concrete 1:2:4 type B0, (using 12.5 mm graded crushed stone aggregate) as levelling course on existing concrete surface over a coat of cement slurry as specified in MES SSR Part I complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour 25 mm thick plain cement concrete 1:2:4 type B0, (using 12.5 mm graded crushed stone aggregate) as levelling course on existing concrete surface over a coat of cement slurry as specified in MES SSR Part I complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour 450mmX350mm X 7-8 mm thick glazed ceramic coloured tiles in vertical surfaces such as skirting, dado, etc set & jointed in neat cement slurry and pointed in white or colured cement to match over & including 10 mm thick backing coat in cement and sand mortar (1:3) complete all as specified and directed. Note :- (i) Quoted rate shall deem to be included cost of backing coat. (ii) Tles shall be Ist quality / premium grade.
Material and labour 300mmx300mm x 7-8 mm thick non skid coloured ceramic tiles in floor, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement and sand mortar (1:6) complete all as specified and directed. Note :- (i) Quoted rate shall deem to be included cost of screed bed. (ii) Tles shall be Ist quality / premium grade.
Material and labour 20-25mm thick machine cut kota stone slab size (550x550mm) in flooring mirror polished, set and jointed in neat cement slurry, pointed with grey cement slurry mixed with pigment to match the shade of the slab complete including rubbing and mirror polishing over and including 20mm thick cement and sand mortar (1:6) bedding layer including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and cement slurry shall be applied over existing concrete surface for bonding with new one as specified in MES SSR Part-I complete all as specified and directed. Note:- (i) Quoted rate shall deem to included cost of bedding layer, cement slurry, and roughening surfaces of old concrete floor.
Material and labour 20-25mm thick machine cut kota stone slab in riser of steps skirting, dado's and pillers etc mirror polished, set and jointed in neat cement slurry, pointed with grey cement slurry mixed with pigment to match the shade of the slab complete including rubbing and mirror polishing over and including 10mm thick cement and sand mortar (1:4) bedding layer including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and cement slurry shall be applied over existing concrete surface for bonding with new one as specified in MES SSR Part-I complete all as specified and directed. Note:- (i) Quoted rate shall deem to included cost of bedding layer, cement slurry, and roughening surfaces of old concrete floor.
Machine pressed, factory made, precast concrete interlocking paver block with heavy duty designer pattern coloured paver block using grey cement and pigments any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade laid over sand cushioning including filling of joints with sand complete. Note :- (i) Quoted rate shall deem to be included cost of 30 mm thick sand cushioned below paver and during compaction. (ii) Design and colour of paver block shall be as approved by GE. (iii) Paver shall be rubber moulded.
Material and labour Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) including jointing with neat neat cement slurry mixing pigment to match the color complete all as specified and directed. Note :- (i) Quoted rate shall deem to be inlcude cost of cement bedding.
Dismantling, floor, hearth or wall tiling including cement mortar bedding etc including preparation of surface to received new floor finish/wall tiles and removing rubbish outside MOD land.
Material and labour 10 mm thick rendering in cement and sand mortar (1:3) on fair faces of brick work or concrete surfaces on ceiling finished even and fair complete all as specified and directed.
Material and labour 15 mm thick rendering in cement and sand mortar (1:6) on fair faces of brick work surfaces finished even and fair complete all as specified and directed.
Material and labour 15 mm thick rendering in cement and sand mortar (1:4) on fair faces of brick work surfaces finished even and fair complete all as specified and directed.
Taking down cement plaster on brick walls, etc, including raking out joints, hacking for key, scrubbing down with water etc & prepare surface to receive new plaster complete all as specified and directed.
Preparing new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
Material and labour preparing new plastered surfaces of wall and applying three coat of white wash complete all as specified and directed.
Material and labour preparing new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour preparing old decorated plastered or unplastered surfaces of wall including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salt and trading oil and greasy spots and applying one coat of white wash on wall surfaces complete all as specified and directed.
Material and labour preparing old decorated plastered or unplastered surfaces of ceiling including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efforescent salt and trading oil and greasy spots and applying one coat of white wash on ceiling surfaces complete all as specified and directed.
Supply and fix in repair 3mm thick sheet glass, ordinary quality in square not exceeding 0.5 square metre each pane complete all as specified and directed.
Supply and fix 3mm thick sheet glass, ordinary quality in square not exceeding 0.5 square metre each pane complete all as specified and directed.
Supply and fix 3mm thick sheet glass, ordinary quality glazing with oil putty or wooden beads in square not exceeding 0.5 square metre each pane complete all as specified and directed.
Material and labour preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for preparation old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour preparing new or previously untreated surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Trial Boring 250 mm dia size pilot bore in any kind of starta including hard stone/boulder by means of direct rotary or reverse rotary or reverse rotary ring method upto 155 metre depth below ground level. Note :- 03 Numbers trial bore each having 155 metre depth
Drilling reaming vertical bore 625 mm dia at approved site/location in any type of strata for 300 mm ERW casing pipe for 70 metre depth from ground level including all works pertaining to boring complete in all respect complete all as specified and directed.
Drilling reaming vertical bore 525 mm dia at approved site/location in any type of strata for 200 mm ERW casing pipe total depth exceeding 70 metre from ground level and not exceeding 155 metre depth from ground level including all works pertaining to boring complete in all respect complete all as specified and directed.
Supply and assembling including jointing lowering ang fixing in position plain mild steel sheet ERW casing pipe 300 mm bore, Heavy duty wall thickness of pipe 8 mm confirming to IS 3589 class 8.1.1 plain end pipe, jointed and welded with coupler rings welding shall be done through out circumference of the pipe and coupler ring both side complete all as specified and directed. . Note :- Length of one piece of pipe shall not be less than 2.4 mtr except where pipe length required is less than 2.4 mtrs.
Supply and assembling, jointing plain mild steel sheet ERW casing pipe 200 mm bore wall thickness of pipe 8 mm confirming to IS 4270-1992 complete and lowering and fixing in position depth exceeding 70 metres of reducing socket for the bore of 300 mm x200 mm bore centering guide made out of 50x6mm MS flat iron on liner assembly complete all as specified and directed. Note :- (i) Unit quoted rate shall be deemed to included the cost of reducing socket. (ii) Length of one piece of pipe shall not be less than 2.4 mtr expect where pipe length required is less than 2.4 mtrs. (iii) Jointing and welding with coupler rings welding shall be done through out circumference of the pipe and coupler ring both side.
Supply, assembling, jointing, lowering and fixing in position MS strainer / slotted pipe of size 200 mm dia slot size size 1.55mm x75 mm as per IS provn uniformly distributed on the surface wall thickness of pipe 8 mm and max length of pipe 6mtr long mild steel, plain beveled ends in built welding complete all as specified and directed.
Supply and fix mild steel reducing socket 300 mmx200 mm dia of suitable length including welding, mild steel strip 40x6mm 2 Nos on each joint extended on each side complete all as specified and directed. (The wall thickness of socket not less than 7 mm thick).
Supply and fix wrought iron well plug 200 mm bore wall thickness 10 mm made up with mild steel sheet including two coats of syenthetic enamel painting over one coat of primer complete all as specified and directed.
Supply and fix well cap for 316mm dia housing pipe and 8 mm thick MS sheet threaded and similar to housing pipe complete all as specified and directed.
Supply and fix two Nos MS flat iron 150mm x 15mm housing clamp for holding to 300 mm dia housing pipe with 16 mm MS bolt & washers including casting of PCC blocks 1:2:4 type B-1 using 20mm graded stone aggregate of size 1.20 M x 1.00 M including 50mm dia MS pipe 2 Nos each 1.5mtr long with cap plug and cap top for filling pea gravel including necessary excavation & each work in any type of soil complete all as specified and directed.
Material and labour for pea gravel of size 2 to 4 mm of natural shape brought direct from rever bank and packing around the casing pipe of mild steel to entire depth upto ground.
Development of tube well by means of high capacity air compressor, not less than 600 PSI for minimum 24 hrs till the water become sand and silt free including removal of surplus soil mud to a distance not exc 50 mtr away, complete all as specified in IS 11189-1985 para 4.3 and as directed by the Engineer in charge. Note:- (i) Compressor, fuel, manpower and any other equipment of suitable capacity for the development of tube well shall be arranged by the contractor at under his own arrangement and no extra shall be paid on this account. (ii) A proper record and log sheet for running of compressor shall be signed by the contractor and Engineer-in-Charge and countersigned by GE.
Supply of sodium meta hexa phosphate for disinfection of borewell all as specified and directed.
Development of tube well by means by means of over pumping for subsequent hours until clear discharge as per clause 9.3.2 of IS 2800 (Part-1) -1991 all as specified and directed.
Supply only strata sample box with glass cover 3mm thick and having internal dimension 1.0 mtr x 0.60 mtr x 0.10 mtr made out of shisham plank 20mm thick with hinges and staples including polishing complete with samples at various depth met at the time of boring including stata chart in duplicate.
Chemical bilogical and potability testing of water sample taken from the bore at Govt approved laboratories. Note:- (i) Testing charges and transportation shall be born by contractor. (ii) Test certificate obtained from approved lab will be submitted by the contractor in original.
Yield testing for bore well by continuous pumping for 16 hrs to determine safe pumping yield of the tube well as per clause 5 of IS 2800 (Part-II) -1979 complete all as specified and directed.
Electric logging in trial bore precise delineation of annular zones and also the quality of ground water including report interpreatation complete all as specified and directed. Note :- (a) Electric logging shall be carried out by approved agency. (b) Unit rate quoted by tender shall be deemed to include cost of MS pipe and transportation of rig accessories required, developing and testing etc at site of work and removal of the same on completion from the site including necessary supervision and rent charges of rig machine compressor & OP unit (any other T&P not specifically mentioned) in respective item of Sch 'A' above, no extra payment shall be admissible on this account.
Supply and fix air release valve of cast iron with suitable to connect column pipe of rising main flanged and column pipe compelte with nut, bolt washer etc including grouting 4 numbers bolt on PCC platform (PCC 1:2:4 type B-1 using 20 mm graded stone aggregate) suitable size and thickness as directed by Garission Engineer. Note :- (i) PCC platform including excavation etc shall e included in quoted rate. (ii) Minimum size of plateform shall be 1.00 mtr x 1.00 mtr x 0.15 mtr height above natural ground level.
Supply, lowering, jointing and testing MS black column pipe heavy duty 100 mm bore wall thickness 5.4mm both ends flanged with heavy duty MS flanged not less than 16mm screwed and welded in side and outside. The flanged end making surface shall be smooth including welding of 04 strip of 5.04mm thick 25mm wide and 50mm long covering pipe and flanged, both end flanged having 08 Nos predrilled hole not less than 16mm including rubber gasket, nut bolts and washer, pipe should be duly painted with anti corrosive paint complete all as specified and directed. Note: Length of each column pipe is 3 mtr long.
Supply, installation, commissioning and testing submersible pumping set electric driven of capacity to discharge 700 LPM at 80 mtr head, directly coupled with electric motor, AC 3 phase, 415 volts 50 Hz, with copper wound water proof winding complete with flange adoptor suitable for connection with 100 mm dia flanged column pipe with price list and literature as recommended by manufacture complete.(for PH-12)
Supply, installation, commissioning and testing submersible pumping set electric driven of capacity to discharge 945 LPM at 80 mtr head, directly coupled with electric motor, AC 3 phase, 415 volts 50 Hz, with copper wound water proof winding complete with flange adoptor suitable for connection with 100mm dia flanged column pipe with price listand literature as recommended by manufacture complete.( for PH-11)
Supply, installation, commissioning and testing submersible pumping set electric driven of capacity to discharge 1375 LPM at 75 mtr head, directly coupled with electric motor, AC 3 phase, 415 volts 50 Hz, with copper wound water proof winding complete with flange adoptor suitable for connection with 100mm dia flanged column pipe with price list and literature as recommended by manufacture complete.(for PH -16)
Supply and fixing round strand steel wire sling 3/8" dia from submersible pump to outside fixing arrangement including proper anchoring as per strandard norms complete all as specified.
Supply and fixing of PVC insulated flat copper submersible cable heavy duty 16 sqmm 3 core 1100 volt grade of the following size complete all as specified and directed.
Supply and fixing of PVC insulated flat copper submersible cable heavy duty 25 sqmm 3 core 1100 volt grade of the following size complete all as specified and directed.
Material and labour upto 150mm bore cast iron (CI)/ ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
Supply, fixing, jointing and testing in repair of cast iron sluice valve 100mm class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed.
Supply, fixing, jointing and testing of cast iron sluice valve 150mm class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed.
Material and labour for PVC pipe heavy grade 75mm bore 6 Kg bar pressure and laid in trenches for protection of submersible cable with all fixing accessories etc complete all as specified.
Material and labour for Boring of holes of 200 mm dia under the road/ hard standing by horizontal boring method 2 mtr below the surface for fixing requiste 2 nos. All Equipments & Machinery required to carry out the work will be provided by the contractor (If due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same) complete all as specified and directed.
Supply and fix of DIGITAL WATER LEVEL INDICATOR DEVICE, operating on Single Phase Supply, direct display in 19 mm size digit system in meter/centimeter of water level of OVER HEAD TANK/ UNDER GROUND SUMP, the entire unit must operate through a compact electronic circuit, which must ensure reliable operation at 230 volts +/- 5% with reliable in digit display, the circuit must be housed in M.S. CRC Sheet box with nylon moulded connection strips. The level system must resistance transducer, which unaffected by corrosion and other contacts available in water. The product must be controlled by micro switch (should not be sensor system), the whole unit must electronically controlled and the upper level and lower level indicator must be highly sensitive MICRO SWITCH. The complete unit must be in tow parts. Each complete part must be fitted in MSCRC Sheet Box separately One must be installed at over head tank/UG sump and second at PUMP HOUSE with proper powder coating paints, complete all as specified and directed.
Supply and fix of 01 Sq mm 03 core PVC insulated copper cable For WATER LEVEL MONITOR DEVICE including GI wire 2mm thick for hanging with copper cable complete all as specified and directed.
Supply Installation of AUTOMATIC PHASE SEQUENCE CORRECTOR for Submersible pump capacity upto 21 HP to 30HP, Type :- RPC-30Automatically Correct Input Supply Reverse Phase and for Protections against Single Phasing Voltage Unbalancing, Low Voltage High Voltage with time delay complete all as specified and directed.
Supply Installation of AUTOMATIC PHASE SEQUENCE CORRECTOR for Submersible pump capacity upto 31 HP to 50HP, Type :- RPC-30Automatically Correct Input Supply Reverse Phase and for Protections against Single Phasing Voltage Unbalancing, Low Voltage High Voltage with time delay complete all as specified and directed.
Supply & fixing single core 4 sq mm multistand and Flexible copper cable for Automatic Phase Sequence Corrector complete all as specified and directed.
Supply & fixing single core 10 sq mm multistand and Flexible copper cable for Automatic Phase Sequence Corrector complete all as specified and directed.
Supply & fixing single core 16 sq mm multistand and Flexible copper cable for Automatic Phase Sequence Corrector complete all as specified and directed.
Supply installation, commissioning and testing of bulk water meter Cast Iron enclosed 100 mm dia (metallic gear) Flanged end complete all as specified and directed.
Supply installation, commissioning and testing of bulk water meter Cast Iron enclosed 150 mm dia (metallic gear) Flanged end complete all as specified and directed.
Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends for reusing and removal of unserviceable part from the site including burning out joints and recovering lead complete all as specified and directed for 150 mm bores size of pipe. complete all as specified and directed. Note :- Necessar Earth work shall be measured and paid separately in respective item of BOQ.
Supply and fix 15mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings or laid in floors etc and testing. Note :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe.
Supply and fix 20mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings etc and testing. Note :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe.
Supply and fix 50mm dia Tubes, ‘light grade’ galvanised, with all fitting fixed on walls, polls with clamps nut bolts and washers or laid under road crossing complete all as specified and directed.
Refixing old steel tubing and connections in new or old, connection in wall position (walls, ceiling, floors etc) of 15mm bore size including new fittings. Note :- (i) Quoted rate shall be deemed to include cost of taking down old pipe, including fittings as fuxture, cleaning and refixing old pipe with new fittings. (ii) Old fitting and fixture retrieved shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's dus.
Refixing old steel tubing and connections in new or old, connection in wall position (walls, ceiling, floors etc) of 20mm bore size including new fittings. Note :-(i) Quoted rate shall be deemed to include cost of taking down old pipe, including fittings as fuxture, cleaning and refixing old pipe with new fittings. (ii) Old fitting and fixture retrieved shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's dus.
Taking down 15mm bore GI tubing and connection fixture etc from wall complete. Note :- Old retrived pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment.
Taking down 20mm bore GI tubing and connection fixture etc from wall complete. Note :- Old retrieved pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment.
Material and labour hoisting and fixing Rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered, 500 Ltr capacity, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection including ball brass valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed 20mm dia polythene floated fly nut, tank nipple, 2 Nos 20mm dia union, wash out pipe etc including dismantling of existing unserviceable water tank of any type complete Note :- (i) Old tank with fitting shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.
Material and labour taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
Supply and fix 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floor or fixed to wall. Note :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely as supply only. (ii) Excavation and earth work shall be measured as paid for separately under respective item of this schedule.
Supply and fix PVC vent cowl suitable for 110mm bore pipe complete all as specified and directed.
Supply and fix cast iron floor trap, 100mm outlet dia, plain with stainless steel grating including jointing with cement complete all as specified and directed.
Supply and fix PVC junction (single T) equal or unequal with access door suitable for 110mm bore pipe complete all as specified and directed.
Supply and fix PVC SWR bend any radius suitable for 110mm bore pipe complete all as specified and directed.
Supply and fix PVC waste pipe 32 mm dia 800 mm long for wash basin etc complete all as specified and directed.
Supply and fix PTMT 15mm bore PVC braided connection 450 mm long with two numbers check nut washers etc including taking out existing PVC connection complete all as specified and directed. Note : Make Paryag/Hindware/Cera
Supply and fix 15mm bore pillar taps fixed in repair chromium plated cast copper alloy, fancy type, screwed for iron pipe or for brass for iron pipe or for unions and fixed including taking out existing pillar tap complete all as specified and directed. Note : Make Paryag/Hindware/Cera
Supply and fix 15mm bore angle valve cast copper alloy, fancy type, with long shank and cup (concealed type) chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends (externally threaded) for iron pipe or for unions and fixed. Note : Make Paryag/Hindware/Cera
Supply and fix in repair bib tap with wall flange, fancy type, chromium plated, brass, screwd for 15mm bore iron pipe with capstain head complete. Note : Make Paryag/Hindware/Cera
Supply and fix in repair 20 mm dia brass Gun metal gate valve with iron wheel screwed both ends for iron pipe or for unions and complete all as specified and directed.
Supply and fix in repair vitreous china squatting pan Orissa Pattern of size 580 x 440 mm with integral foot rests, cast iron 'P' or 'S' trap, connection to trap and flushing pipe, antisyphonage pipe etc with and includng provision of PCC (1:5:10) type E2 in filling, PVC low level flushing cistern of 10 liter capacity, 32mm dia PVC flush pipe connected to water closet with inlet, PVC braided connection and angular valve with wall flange etc complete all as specified iand directed.
Supply and fix in repair vitreous china wash hand basin (white), flat back of minimum size 550mm x 440mm with and including a pair of cast iron brackets embedded in PCC (1:3:6) type C1 blocks of size 10x 7.5x15cm, 32 mm dia PVC waste pipe of suitable length, 32mm bore chromium plated brass waste fitting, PVC braided connection, CP coupling, pillar tap CP long neck, CP angular valve with flange, CP bottle trap etc complete all as specified and directed. Note :- (i) Make - Cera cat part No 1007, Hindware cat part No 10036 or equilvant make of Perryware (ii) Make of pillar tap Paryag/Hindware/Cera
Supply and fix in repair shelf PTMT fixed with and including chromimum plated brass screws wooden/plastic cleats (minimum weight 300 gms) complete all as specified and directed.
Supply and fix in repair 600mmx450mm and 6mm thick bevelled edge looking mirror mounted on 6mm thick backing comercial plywood with aluminimum frame fixed with CP plug with chromium plated brass screws and cup washer fixed on wall complete including taking out existing mirror. Make : SAINTGOBIN/MODIGUARD
Supply and fix in repair tubular towel rail 20 mm dia 600mm long chromimum plated fixed to wall with chromium plated stainless steel screws and PVC sleeves complete.
Taking down carefully existing aluminium/copper batten concealed point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fitting and fixture as directed and deposited in MES store yard of GE (AF) Bamrauli. Receipt shall be obtained before claiming the payment of new fittings. (ii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iii) Old unserviceable wiring fittings, fixture, etc other than light fittings shall be contractor's property and necessary amount as per schedule of credit from contractor due payment.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for switches, sockets and switch for one light point /fan point/exhaust fan / calling bell controlled by one switch. Note : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (ii) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly suitable for bell push for one bell/buzzer point controlled by one switch on independent board. Note :-(i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (ii) Switches, sockets, etc shall be measured and paid for separately under respective item of this schedule.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for 3 pin 5 Amp sockets for one sockets outlet on same board controller by one switch. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 4 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 4 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controller by one switch 15/16 Amps. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Supply and fix modular Switch piano flush 6 A single pole one way.
Supply and fix Ceiling rose, surface bakelite, 60 x 25, mm three terminals.
Supply and fix modular socket 2 in 1 6/16 Amp, 5 pin combined flush type.
Supply and fix modular socket 6 Amp, 2 in 1, 2/3 Pin flush type.
Supply and fix Switch piano flush, 15/16 A, single pole, one way.
Supply and fix steped type electronic fan regulator 120 watts and connecting upcomplete all as specified and directed.
Sypply and fix factory made sheet metal enclosures distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, single pole and neutral, 8 ways, 240 volts including taking out old DBs. Note :- (i) MCBs shall be measured and paid for separately under respective item of this schedule. (ii) The unit rate quoted by tenderer is deemed to included the cost of makin good to damaged portion of wall.
MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before..
MCB, Single pole and neutral, 230 volt, 32 Amp rating 10KA, C series fixed in DBs catered herein before.
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supplying, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade, connecting both end with suitable lugs of cross sectional area 10 sqmm 2 core, . Note :- (i) Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. (ii) Cost of Aluminimum thimbles / lugs and cable gland is included in unit rate quoted by contractor.
Supply, fixing in and connecting wall mounted LED light fitting 1 x 18 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection complete all as specified and directed.
Supply, fixing and connecting batten extruded surface mounting LED light fitting mirror type with 10 Watt LED (6000K/6500K) 2 feet long extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection complete all as specified and directed.. .
Supply, fixing and connecting post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrision resistant with driver and lamp including necessary electric connection complete all as specified and directed.. .
Supply, fixing, connecting and testing LED light fitting 35 Watt, 6000 K pressure die cast aluminium housing, heat resistant toughned glass, with frame IP-66 protection, better optics for uniform distribution road way luneiaries complete and connecting the fitting electrically including provision of single arm bracket made of 40 mm dia light grade GI pipe (1.2 metre long) bending to angle of 120 degree and mild steel flat iron 32 x 6 mm clamps of suitable size two numbers including nut, bolt and washers fixed on wall complete. Note :- (i) Fitting shall be of Havells/Crompton/Philips/Bajaj (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor. (iii) MS clamps shall be painted with two coat of aluminium paint over a coat of redoxide primer.
Supply and fix of exhaust fan steel body 300/308mm sweep, heavy duty, four blade, double ball bearing 1400 RPM minimum air delivery discharge 6120 CMH suitable for SP, 230/250 volts, 50Hz, AC supply with louver shulter complete making of hole for exhaust opening, grouting nut, bolts and connecting with and including 3 run 1.5 sqmm single core, PVC insulated but unsheathed FRLS multistranded copper conductor cable from ceiling rose to fan and making good the disturbed surface with existing matching schedule of finishes complete.
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 32x6 mm as earth strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 150mm thickness below or above ground floor including hacking of concrete surfaces to receive new concrete/ floor finishes and removing rubbish out site MOD land. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Material and labour demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Material and labour dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Material and labour dismantling posts or struts (wood, steel or RCC) any section including taking out embeded portion and making good disturbed ground complete all as specified and directed.
Material and labour dismantling of brick tiles laid bedded and pointed in any mortar or brick tiles on roof, floors, channels, kerbs, aprons etc. cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, including cleaning the surfaces with wire brushes etc complete all as specified and directed. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
M/s NSA Engineering Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .