| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹45.5 L+₹1.2 L (2.82%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹51.0 L+₹6.7 L (15.1%)Rejected-AOC NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹54.7 L+₹10.5 L (23.6%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹54.9 L+₹10.6 L (23.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹58 L
EMD Value
₹1.1 L
Closing Date
30 Apr 2022, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
PROVISION OF LT PANEL AND ALLIED ELECTRICAL INFRASTRUCTURE AT SAIDAPET AND MEENAMBAKKAM UNDER AGE (I) NAVY CHENNAI
2022_MES_516335_1
CA No.CWE/NAVY/CHN/82504/E8 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHENNAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE I NAVY CHENNAI
₹1.1 L
Yes
26 May 2022
2 Apr 2022
2 May 2022
2 Apr 2022
30 Apr 2022
23 Apr 2022
4 Apr 2022 - 18 Apr 2022
Amount
Fabrication, Supply, Installation, Testing and commissioning of Outdoor type LT Panel , self supporting, totally enclosed mounted on Base channel of size 40 mm x 40 mm x6mm, from CPRI certified Panel builder, factory fabricated made out of not less than 3 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (25 x 6 mm) connecting provision - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. Panel board shall be suitable for 3 phase 4 wire, 415 volts 50 hz, panel size shall be suitable for mounting and including the following items and connecting all outgoing feeder cables using suitable size lugs of any type and bus bar should be electrolytic copper bus bar with not less than 50mm width x 5 mm thickness or current carrying capacity not less than 630 amps complete all as specified and directed.
(I) Incomer - MCCB 415 V,400 A, 4 pole 36 KA with protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current. 01 Nos
Outgoing- (i) MCCB 415 V,200 A, 4 pole 36KA with protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current.- 02 Nos
(ii)MCCB 415 V,160 A, 4 pole 36KAwith protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current.- 01 Nos
(iii) MCCB 415 V,100 A, 4 pole 16KA with protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current.- 02 Nos
(iv)Smart Demand controller as per IEC 62053 21/22versatile and fully user programmable suitable for HT/LT with CT/PT with demand planning Present demand,max demand,predictive demand with date/time etc
(v)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard praticealongwith indicating lamps
(vi) Resin cast current Transformer 250/5A - 3Nos
Supply ,fixing,testing and commissioning of servo voltage stabilizer copper wound of capacity 100 KVA for automatic operation three phase,natually oil cooled in and including transformer oil complete,Outdoor type and designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second including cable termination box for incoming and outgoing cable and necessary platform with minimum 60cm above ground level and plan size as recommended by manufacturer.complete all as specified and directed. Note:(i) The quoted rate inclusive of connecting the existing outgoing cables of anytype to the servo voltage stabilizer by using new lugs,glands as per site requirement.
Supply, fixing, testing and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity not less than 100 KVAR( 25+25+15+10+5+5+5+5) alongwith incoming MCCB of size not less than 160 Amps and selecor switches/push buttons to operate the APFC Panel manually and indicating lamps of 10 nos to indicate the ON/OFF capacitor bank alongwith incoming cables air circulators -02 Nos internal wiring making/connecting the APFC Panel to the existing main LT Panel complete all as specified and directed. Note:(i) Capacitors should be of oil immersed box type. (ii) It is the contractors responsibility to maintain PF b/w 0.95 to 1 at full load and make suitable arrangements.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 240 sqmm 3.5 core all as specified and as directed (laying in trenches /on wall/cable tray) . Note for items 4 to 7: (i)Excavation ,earthwork, sand filling and laying of HDPE pipe shall be measured and paid for separately. (ii) Cl path indicator fixed on MS angle and painted in blue colour shall be provided as directed by Engr-in-charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 120 sqmm 3.5 core all as specified and as directed (laying in trenches /on wall/cable tray)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 25 sqmm 3.5 core all as specified and as directed (laying in trenches /on wall/cable tray)
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 16 sqmm 4 core all as specified and as directed (laying in trenches /on wall/cable tray)
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc.and getting out for soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm for soft/loose soil complete all as directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply and lay HDPE Pipes PN 10 of 75mm for cable protection,laid complete all as specified and directed.
Supply and fixing , cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 sqmm x 3.5 core complete all as specified and directed.
Supply and fixing , cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm x 3.5 core complete all as specified and directed.
Supply and fix weather proof cable junction boxes suitable for outdoor installaions with knockout for cable entry looping in box PVC with side dimension155mmx210mmx92 mm comprising of connector -01nos including mounting arrangements and lugs etc complete all as specified and as directed.
Supply and erecting Galvanized Octagonal pole of 5 mtr height with galvanization of 65 micron average thickness and Bottom 130mm, top 70mm and base plate 12mm thickness with necessary arrangements including 4 nos of J bolt & nuts and supply of 1 no of 16A double pole MCB as incomer with neutral link complete in a proper position with CI base plate, finial taper plug, bolts, nuts, screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed Note:- Earth work shall be measured and paid seperately under the respective item.
Supply and fix energy saving ,street light fittings LED 40 watts luminaire with high power LEDs and unique flood optics to ensure uuniform distribution and saving upto 50% w.r.t conventional system and maintenance free system ,including fixing arrangement on pole by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two Nos made out of 25x3 mm FI, prewired all as specified and as directed.
Material and labour for Cement concrete for foundation of type 1:3:6 C1 using 20 mm graded aggregate complete all as specified and directed.
Supply and fix PVC insulated two single core 1.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including suitable dia non metallic rigid PVC conduit and accessories complete all as specified and as directed. Note: (i)Two runs of 1.5 Sqmm main wire+ one run of 1.5 sqmm earth conductor and one run of PVC conduit will be measured as one unit for payment.
Cutting the existing road for passing cable (45 cm width and 75 cm depth) and making good the disturbed surface by using 15 mm thick, PCC (1:2:4) , Type B1 (using 20 mm graded aggregates) as in mass concrete complete all as specified and directed.
Material and labour for Earthing complete with using copper plate60cm×60cm ×3.15mm thick electrodeand 20×3mm copper strip as earthing lead and GI protection Pipe as protection 15 mm pipe and alternate 5 layers of charcoal (250 Kg) & salt crystal (200Kg) and top two inches layers with Back filling compound (100 Kg), all as specified. buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and by means of GI bolts and nuts,check nuts,washers and copper earth strip protected by GI pipe light grade 40 mm bore upto 7.5 mtr and connecting to earth terminal/ test point etc as per site requirement including necessary excavation, earth work in any type of soil PCC (1:3:6) type C1 chamber and 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No. 3 of MES Schedule Part 1 including watering pipe 20 mm dia medium grade with funnel and with mesh , refiling soil all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included in the rate quoted by the contractor. (iii) Beyond 7.5 mtr the copper earth strip20X3 mm & GI pipe light grade 40 mm dia shall be measured under relevant item of the schedule. (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Material and labour for Chemical earthing with copper earth plate 900x600x5mm & copper earth electrode buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) and chamber to be filled with carbon/bentanite compound incl copper strip 32 x 6 mm upto 7.5 mtr by means of GI bolts and nuts,check nuts,washers and connecting to earth terminal/ test point etc as per site requirement including necessary excavation, earth work in any type of soil PCC (1:3:6) type C1 chamber and 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No. 3 of MES Schedule Part 1 Note:(i) Quoted rate deemed to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) copper earth strip , (iii) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 1 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Material and labour for 4mm dia galvanised iron or steel wire as Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor for 25 sqmm 4 core, for connecting the cable from state electricty board to new LT Panel as per the estimate provided by TNEB, complete all as specified and as directed (laying in trenches /on wall/cable tray)
Supply and lay HDPE Pipes PN 10 of 50mm for cable protection,laid complete all as specified and directed.
Fabrication, Supply, Installation,Testing and commissioning of Outdoor type LT Panel , self supporting totally enclosed mounted on Base channel of size 40 mm x 40 mm x6mm from CPRI certified Panel builder factory fabricated made out of not less than 3 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (25 x 6 mm) connecting provosion - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc panel board suitable for 3 phase 4 wire ,415 volts 50 hz, panel size shall be suitable for mounting and including the following items and connecting all outgoing feeder cables using suitable size lugs of any type complete all as specified and directed.
(i) Incomer - MCCB 415 V,100 A, 4 pole with protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current. Standard: IEC/IS 60898-1, IEC/IS 60947-2 Icn=10 kA- 01 Nos
(ii)Outgoing- MCCB 415 V,16-63 A, 4 pole with protection and control of the circuits against overloads and short-circuits protection for resistive and inductive loads with low inrush current. Standard: IEC/IS 60898-1, IEC/IS 60947-2 Icn=10 kA- 05 Nos
(iii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard praticealongwith indicating lamps
(iv) Resin cast current Transformer 250/5A - 3Nos
(v) Smart Demand controlleras per IEC 62053 21/22versatile and fully user programmable suitable for HT/LT with ant CT/Ptwith demand planning Present demand,max demand,predictive demand with date/time etc alongwith connected items making it fully functional
Fabrication,Supply, Installation,Testing and commissioning of self supporting totally enclosed mounted on Base channel Outdoor type Timelite distribution board with astronimical time switch contactor connectors and all other necessary connected items.
Excavating in post holes each not exceeding 0.5cum getting out in soft/loose soil, complete all as specified and as directed
Supply only chain link MS galvanised fencing any size or type complete all as specified and as directed
Fixing only Chain link fencing including line wires, any mash, size and type to any type of standard, rail, straining bolts, etc. including provision of binding wire complete all as specified and as directed
Supply and Fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut dia of neck 11 to 15mm and length exceeding 5 not exceeding 10cm Long complete all as specified and as directed
Supply and Fix Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing's and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Supply and Fix mild steel section and embedding in concrete, posts or struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc. flat iron fillets (for securing wire mesh) including all necessary drilling, bolting etc and similar work conforming to Fe410-0. complete all as specified and as directed
Supply and Fix mild steel bars for straightening / ties bars for chain link fencing 10mm dia of over, cut to length and tying with MS wire not exceeding 0.6mm. complete all as specified and as directed
Material and Labour painting to new steel surface of any description not exceeding 10cm width or girth not otherwise described including preparation, priming with zinc chromate and two coats of synthetic enamel paint Complete all as specified and as directed
Material and Labour painting to new steel surface of any description exceeding 10cm width or girth not otherwise described including preparation, priming with zinc chromate and two coats of synthetic enamel paint Complete all as specified and as directed
Material and Labour for Cement concrete type D2, 1;4:8 (40mm graded stone) as in foundations, filling and mass concrete Complete all as specified and as directed
Material and Labour for Brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 Complete all as specified and as directed
Supply and Fix for Framed work such as gates, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including spindle hinges and hold fasts etc Complete all as specified and as directed
Material and Labour Cement concrete 1:2:4 Type B-2 (using 20mm graded stone aggregate) as in bed concrete or fixing of hold fasts Complete all as specified and as directed
Removing excavated material/soil not exceeding 250M and not exceeding 500M and depositing where directed at a level not exceeding 1.5M above the starting point Complete all as specified and as directed
Material and Labour for Rendering 10mm thick on fair faces of brick work or concrete cement in CM 1:4. complete all as specified and as directed
Material and Labour preparation of new surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed
Global Safety Engineering and Management Solutions
SRI LAKSHMI ASSOCIATES
EVEREST ENGINEERING WORKS
M/S.RANGA AND CO
Green Ray Technologies
gandhie constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .