| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹69,798Qualified Make: Panther-I
Model: KEYUN TECHNOLOGY PANTHER -1 | Make: Panther-I
Model: KEYUN TECHNOLOGY PANTHER -1 | ₹69,798 | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
26 Oct 2018, 5:00 pmClosed
breath alcohol analyzers Breath Alcohol Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 500 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 2 2 Easily replaceable mouthpiece with Sputum Trap yes * 1/5 Sample Taking Duration 3 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 10 * Recovery Time at (1/2) mg/ltr 5 * Warm up Time (after putting on) 6 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 600 * Shelf Life of Fuel Cell 2 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 470 * Size ( mm x mm x mm ) - * BATTERY OF ANALYZER Power Source Rechargeable Battery and also work through automobile 12 V DC Power. * Chemistry of Rechargeable Battery Li-ion * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 24 * Number of Spare Rechargeable Batteries supplied with the instrument 0 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type LCD * Display Size 2.8 * Availability of audible beeper for over range
low battery etc yes * 2/5 Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen Minimum Record Fields Full Information as per the user's requirement such as Driver Name
Vehicle number
inspector name
test report with time
date
geolocation
instrument id
etc * Record Memory (Minimum) 10000 10000 Record Data Downloadable to PC yes * Data Interface USB * GPS true * If yes
Capable to display the geolocation of test inspection location yes * Camera false true
false If yes
Capable to capture the clear image of test target NA * PRINTER Printer With With Type of Printer Internal Thermal Printer Internal Thermal Printer Print Resolution (dpi) 200 * Printer consists of Inbuilt Rechargeable Battery
Paper for offence printouts
Charger yes * Minimum number of printouts that can be taken with the paper available with the Printer 100 * "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints
if 'With Printer' May indicate '0' if not applicable)" 100 * Bis Registration number for Printer - * 3/5 under CRS of MeitY WARRANTY Warranty 1 1.0 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement
The instrument is hand held
portable and easy to operate true * If Yes
the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface
meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -15 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 80 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest true * Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest true * Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * 4/5 Test Report Number and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Reny Varghese 560017
AOC 26 EQUIPMENT DEPOT
AIR FORCE po- vimanpura
Bangalore - 17 2 30
692924
GEM/2018/B/98062
breath alcohol analyzers
30 days
Karnataka; Bengaluru Urban
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| breath alcohol analyzers Breath Alcohol Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 500 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 2 2 Easily replaceable mouthpiece with Sputum Trap yes * 1/5 Sample Taking Duration 3 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 10 * Recovery Time at (1/2) mg/ltr 5 * Warm up Time (after putting on) 6 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 600 * Shelf Life of Fuel Cell 2 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 470 * Size ( mm x mm x mm ) - * BATTERY OF ANALYZER Power Source Rechargeable Battery and also work through automobile 12 V DC Power. * Chemistry of Rechargeable Battery Li-ion * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 24 * Number of Spare Rechargeable Batteries supplied with the instrument 0 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type LCD * Display Size 2.8 * Availability of audible beeper for over range | - | - | - |
| low battery etc yes * 2/5 Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen Minimum Record Fields Full Information as per the user's requirement such as Driver Name | - | - | - |
| Vehicle number | - | - | - |
| inspector name | - | - | - |
| test report with time | - | - | - |
| date | - | - | - |
| geolocation | - | - | - |
| instrument id | - | - | - |
| etc * Record Memory (Minimum) 10000 10000 Record Data Downloadable to PC yes * Data Interface USB * GPS true * If yes | - | - | - |
| Capable to display the geolocation of test inspection location yes * Camera false true | - | - | - |
| false If yes | - | - | - |
| Capable to capture the clear image of test target NA * PRINTER Printer With With Type of Printer Internal Thermal Printer Internal Thermal Printer Print Resolution (dpi) 200 * Printer consists of Inbuilt Rechargeable Battery | - | - | - |
| Paper for offence printouts | - | - | - |
| Charger yes * Minimum number of printouts that can be taken with the paper available with the Printer 100 * "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints | - | - | - |
| if 'With Printer' May indicate '0' if not applicable)" 100 * Bis Registration number for Printer - * 3/5 under CRS of MeitY WARRANTY Warranty 1 1.0 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement | - | - | - |
| The instrument is hand held | - | - | - |
| portable and easy to operate true * If Yes | - | - | - |
| the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface | - | - | - |
| meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -15 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 80 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest true * Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest true * Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * 4/5 Test Report Number and Date - * Name of the Lab and Address - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Reny Varghese 560017 | - | - | - |
| AOC 26 EQUIPMENT DEPOT | - | - | - |
| AIR FORCE po- vimanpura | - | - | - |
| Bangalore - 17 2 30 | - | - | - |
Exempted
26 Oct 2018
16 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_692924.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].