| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹59,998.37 (1.72%)Rejected-Finance HOLDING NO 198 178 WARD NO 23 NEAR SHAKTIBHAVAN INDA KHARAGPUR WEST BENGAL 721 305 | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721305 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹37.0 L+₹2.1 L (6.13%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹38.4 L+₹3.5 L (10.1%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L4 | Rejected-Finance Not Being L1 |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
29 Dec 2021, 6:00 pmClosed
GE (AF) KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
SPECIAL REPAIRS TO TRANSIT-I and II ,VIP-II OF OFFRS MESS AND CERTAIN LIVING IN SNCO,S ROOMS AND PROVISION OF SOCKET FOR AIR CONDITIONER WITH ALLIED INFRASTRUCTURE IN CERTAIN SMQ,S IN PHASE -I AT AIR FORCE STATION SALUA UNDER GE (AF) KALAIKUNDA
2021_MES_492192_1
8726/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN SALUA
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) KALAIKUNDA
₹69,800
Yes
9 Apr 2022
3 Dec 2021
31 Dec 2021
3 Dec 2021
29 Dec 2021
17 Dec 2021
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down shutters of any description exc 1 sq. m and not exc 2 sq.m each complete all as specified and directed.
Refixing in same opening shutters of any description exc 1 sq. m and not exc 2 sq. m each complete all as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Dismantling water tanks capacity exceeding 250litres but not exceeding 1000 Litres and removing to store complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil ,complete all as specified and directed.
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 Metres and depositing where directed at a level n. exc. 1.5 M above the starting point complete all asspecified and directed.
Materials and Labour for, broken stone or boulder hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
Supply only integral water proofing compound all as specified
Cutting holes in brick walls in cement mortar and stone walls built in lime mortar for inserting holdfasts or lugs upto depth exceeding half brick but not exceeding one brick measured from the face of the jamb into the wall and making good dismantled portion in cement mortar 1:3 or cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
S & F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, quality confirming to GDE Fe410-W (Gde-E-250) complete all as specified and directed.
Materials and Labour for for 75 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded aggregate as in sub base floor/paving/hardstanding/Plinth protection, complete all as specified and directed.
M&L for cement concrete 25 mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) as in base of flooring, finished even and rough to receive the top layers all complete as specified and as directed
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 8 to 9mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,conforming to IS 15622, Grade B II, in riser of steps, skirting, dado and pillar laid over cement screed base including 15 thick rendering Cement mortar (1:3) complete all as specified and directed
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 8 to 9 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 300 X 8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
Material and Labour for Digital Vitrified Ceramic Tiles, , 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, on floors, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match colour over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6), complete all as specified and directed.MAKE:- (Johnson/Kajaria or equivalent make )
Materials and Labour for, Digital Vitrified Ceramic Tiles, , 10 mm thick (square/rectangular) polished area of each tile not exceeding 0.36 Sq M, conforming to IS 15622, Grade B II, on vertical surfaces of wall such as dados, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.MAKE:- (Johnson/Kajaria or equivalent make )
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface other than fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling /chajja surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls/ceilings including priming with alkali resistant priming paint and including preparation of surfaces complete all as specified and directed.
M&L for preparation of new plastered or un -plastered from walls, and applying two coats acrylic distemper on walls, over and including a coat of 3 mm thick white wall care putty and a coat of primer complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor) /Nerolac (Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coats acrylic distemper on the wall all as specified and directed. Note: 2nd shall be applied after dried of Ist coat and after approval from Engineer incharge .
Preparation of old surfaces of ceiling by brooming down with steel wire brushing scrapping down smoke dust, moulds, moss and efflorescent salts and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying two coats acrylic distemper on the ceiling all as specified and directed. Note: 2nd shall be applied after dried of Ist coat and after approval from Engineer incharge .
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling /soffits including cornices, pilasters and other ceiling /soffits features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with external wall care putty as per existing thickness and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with external wall care putty as per existing thickness and applying one coat of cement base paint on wall complete all as specified and as directed.
Material and Labour for complete removal of existing treatment and making good with putty as per existing thickness and applying two coats acrylic distemper on the wall all as specified and directed
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparation of old painted surfaces of Steel surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel painting complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood base surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel painting complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M & L for frame work consisting sections made of mild steel sheet galvanised with zinc coating of grade 120 gram per sqm as per IS 277 as per IS 277: 2003 and the sections of perimeter channel of size 20 mm (flange) X 27 mm (web) X 30 mm (flange) X 0.50 mm (thickness), intermediate channel of size 15 mm (flange) X 45 mm (web) X 15 mm (flange) X 0.80 mm (thickness), ceiling section 80 mm (total width) X 26 mm (flange) X 51 mm (web) X 0.50 mm (thickness), angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, angle hangers of size 25 mm X 10 mm X 0.50 mm and of required length, mild steel galvanised with zinc coating dash fastener of size 12.5 mm dia x 50 mm long and connecting clip made out of 2.64 mm dia x 230 mm long galvanised mild steel wire, fixing perimeter channel on the wall along the perimeter of ceiling using nylon sleeves wall plug at 450 mm centre to centre spacing, hanging intermediate channel at 900 mm centres to centre spacing with soffit of ceiling using rawl plug, dash fastener, angle cleat, angle hangers at 900 mm centre to centre spacing, fixing ceiling section to the intermediate channel transversely at 450 mm centres to centre spacing using connecting clip at every junction with and including gypsum wallboard, 12.5 mm thick as per IS 2095 (Part 1): 2011, tapered edge, fixing to ceiling section and perimeter channel using dry wall screws of size 3.5 mm X 25 mm at 230 mm c/c including jointing and finishing to a flush finish of tapered edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint complete all as specified and as directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
Supply and Fix, factory made solid panel Plain PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M&L for medium density fibre board 18/19mm , exterior grade, prelaminated both sides with decorative choice laminations , fixed with screws to timber frame work complete all as specified and as directed
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 25mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply and Fix,steel ventilator with fixed type shutter including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 75 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 100 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F PVC connectors 15 mm bore 600mm long with brass connections & washers all as specified.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and Fix, in repair fancy bib tap, brass cast copper alloy, , chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
S & F in repairs 15 mm nominal size, fancy pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
S & F in repair 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repair vitreous china squatting pan, 'Orissa" pattern, size 630 mm X 450 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repair 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs wash basins, vitreous china, white, flat back, size 650 mm X 450 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings,brass pillar tap 15mm bore cp, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
Supply and Fix Corner Shelf assembly consisting of 5.5mm thick glass shelf with chromium plated bracket guard and railing all as per Make Parry ware Cat no. T6010A1 Corner Shelf or equivalent of make Jaquar/ Kohler/Marc, complete all as specified and directed.
S&F brass chromium plated hand shower (health faucet) complete all as specified and as directed. Make- Jaquar cat No-ALD-BLK-583 or Marc/Kohler/Parryware)
Supply and Fix, brass chromium plated, 20mm dia towel rail, 60cm long between flanges, complete all as specified and directed.
Supply and Fix, in repair brass chromium plated shower rose 125mm size,with swivel joints, fixed to steel pipe or union 15 mm bore with and including 195mm long arm, complete all as specified and directed.
Supply and Fix, brass CP fancy wall mixer with L bends (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Make Hand shower cat part no. HSH-CHR-1717 and wall mixer cat part no. QQT-7281 of Jaquar or equivalent make Kohler/Marc)
Supply and Fix, in repair brass CP fancy centre hole basin mixer for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed. (Make mixer cat part no. QQT-7169B of Jaquar or equivalent make Kohler/Marc)
S & F in repair Vitreous China wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern, cp jet nozzle for EWC and flush pipe with and including PVC seat cover complete all as specified and as directed.
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 4 sqmm cable and one run of conduit will be measured and paid as one unit length. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) One light point controlled by one switch 5 Amps
(b) One fan point/Exhaust fan point controlled by one switch 5 Amps
(e) One bell point controlled by one bell push
(d) One 3 pin socket outlet 5 Amps on same board
(c) One 3 pin socket outlet 5 Amps on Independent board
Materials and Labour for concealed type point wiring with 2.50 Sq. mm (nominal area) (FRLSH) as per IS 694: 2010, ISI marked PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, drawn in and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc including sunk type pressed steel terminal boxes 60 mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switch socket outlet etc and including 2.50 Sq. mm (nominal area) (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3 Pin 15 Amps socket out let independent, complete all as specified and directed.(Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule.
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Socket, 6 Amps, 2/3 Pin, 2 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Socket 6A/16A - 2/3 pin combined 2 module,complete all as specified and directed.
Supply and Fix in repairs, Modular Fan step regulator, 120W - 2 module,complete all as specified and directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and Fix in repairs, Modular Bell Push, 6 Amps, 1 Module, complete all as specified and directed.
Supply and fixing LED light fitting mirror type with LED tube lamp nominal power 10 Watt, 2 feet ,LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1000Lumen efficacy of minimum 100 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120 degree clear, IHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per Make :- Century Cat No.BWUL010C OR equivalent of Syska LED/Philip/Wipro or equivalent make as per make catered in Particular specification complete all as specified and as directed. Note : Make of batten and LED tube lamp shall be same
S & F LED tube light fittings(T8 TYPE) with LED tube lamp nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 2100Lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120 degree clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per Make :- Century (Batten Cat No.KCCF0200 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Century Cat No. TWPP020C (retrofit LED tube lamp 20 Watt, Single end connection) OR equivalent of Syska LED/Philip/Wipro or equivalent make as per make catered in Particular specification complete all as specified and as directed. Note : Make of batten and LED tube lamp shall be same make.
Supply and Fix in repairs, LED panel 15 Watts, recess mounted down lighter,round, with polycarbonate housing and polycarbonate diffuser, ceiling cutout 170 mm dia., cutout dimension 155 mm dia., height 37 mm,lumen efficacy up to 100lm/W, CRI :>80,intregrated driver, THD:<20%, integrated colour temperature:6500K, surge protection:2.5 KV, operating voltage:220-240 V AC, Ta:-10°C to 45°C, complete all as specified and directed. [Cat No. "LED Panel 15 W 65 K RD Recess PC Backlit I " Code:6PP26I8RB15 of Make 'Eveready' or equivalent Model of Make 'Philips'/ 'Bajaj'/Century ]
S & F LED bulkhead light with pressure die-cast housing light fittings nominal power 12 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts. frequency of 50 Hz, lumen output of minimum 1100, lumen , , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 3 KV, protection grade IP 65, CRI greater than 80%, ITHD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours as per catalogue No. CENTURY - HWAR012C OR equivalent of CG/Philip/Wipro complete all as specified and as directed.
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated bus bar, Single Pole & Neutral, fixed in repairs including blanking plate , complete all as specified and directed. [Cat No. 5076 11 of Make Legrand or equivalent Model of Make L&T/ Seimens]
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
Supply, installation, commissioning and testing of LT Bus Bar Feeder Piller Box type factory made CPRI approved weather, dust & vermin proof Feeder Piller Box outdoor type having provision of double door openings with rubber beadings cubical type of size 1.00x0.75x0.40 Mtr as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 40 x 40 x 5 mm shall be used for making legs/ frame, duly including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces, including provn of Aluminium Busbar 600 Amps and Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 16 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In. Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.] – 02 (Two) Nos. and suitable insulators and cable gland for terminal connections of cables and fixed with suitable size nuts and botls of size as directed including provn of PCC Platform of suitable size with PCC 1:2:4 as per manufacturer,s all as directed by the Engineer-in-charge. Note: The schematic diag of LT Panels shall be approved by GE before procurement.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through 50 mm bore, galvanised steel tubing,complete all as specified and directed.
Material and labour for 50 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 185 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
All as per item No.114 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and as directed.
All as per item No.114 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and as directed.
All as per item No.114 here-in-before but of size 25 Sqmm 4 core complete all as specified and as directed.
All as per item No.114 here-in-before but of size 10 Sqmm 2 core complete all as specified and as directed.
Supply and filling in dry sand in cable trenches before and after the cables are laid, as in sand cushioning to cables, complete all as specified and directed.
Supply and laying common burnt clay building bricks, sub-class ‘B’ designation 75, old size bricks, in cable trenches, as cable protection, complete all as specified and directed.
BUILDCON
STAR ENTERPRISES
NATIONAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .