Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹1.7 Cr+₹41.8 L (31.9%)Rejected-Finance | ₹1.7 Cr+₹41.8 L (31.9%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.9 Cr+₹56.6 L (43.2%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | ₹1.9 Cr+₹56.6 L (43.2%) | L3 | Rejected-Finance Other than being lowest |
| 4 | Rejected-Technical 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | - | - | Rejected-Technical Not having category c (i) |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
14 Feb 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF AFDS SYSTEM FOR BLDG NO 87 88 120 144 AT ND PROVISION OF DG SET FOR COLD ROOM AND COOL ROOM AT OLD DGNP BUILDING GROUND FLOOR AT ND UPGRADATION OF LT PANELS LT CABLES AND DISTRIBUTION BOX ETC AT AUDITORIUM ARMOURY STORES AND BSQ EMERGEN
2022_MES_499663_1
8446/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Kunjali
Class B
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹2.2 L
Yes
1 Apr 2022
5 Jan 2022
16 Feb 2022
5 Jan 2022
14 Feb 2022
31 Jan 2022
5 Jan 2022 - 29 Jan 2022
Amount
Supplying installation, Testing & Commissioning of Microprocessor based 2 loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved) as per tender specificaiton.Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and as directed. Make : Honeywell/Schneider/Bosch
LANDLINE FIRE ALARM AUTO DIALER WITH sms and Memory Available To Store 10 Phone Numbers dialling facility to reach the fire brigade to get the intimation about the location of the area Builtin Emergency Speech Dialer with 8 Numbers & 1/ 2 Messages,NO/NC contacts for both fire and fault, Automatic changeover arrangement to standby supply with battery charger with low battery indication,Fault/ failure indication such as MAINS FAIL, short, open, Battery FAIL etc,Micro-Controller Based System,Both Dialling Modes Can Be Used (Pulse/Tone),Recorded Message Playback Speaker Provision Available complete all as specified and as directed. Make : Agni/Ravel/Atss
Supply, Installation, testing and commissioning addressable Manual call point(Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters laboratories listed, semi flush type complete all as specified and directed. Make : Honeywell/Schneider/Bosch
Supplying installation, Testing & Commissioning of Addressable monitor modules for Sprinkler Flow Switch and Door Holders complete all as specified and as directed. Make : Honeywell/Bosch/Schneider
Supply fix and commissioning and test of addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as specified and directed. Make : Honeywell/Schneider/Bosch
Supplying installation, Testing & Commissioning of Analog addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC(Above Ceiling & below ceiling.) as complete all as specified and as directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Conventional Beam detector complete as required for hall & indoor open area. complete all as specified and as directed. Make : Honeywell/Schneider/ Bosch
Supplying installation, Testing & Commissioning of Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes etc complete all as specified and as directed. Make : Honeywell/Schneider/Bosch
Supply and fix fault isolator module with automatic resetting arrangement complete all as specified and directed. Make : Honeywell/Schneider/Bosch
Supply & laying PVC FRLS armoured cable 1.5sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supplying installation, Testing & Commissioning of Response indicator for Above ceiling detectors & Cabin Detectors complete all as specified and as directed. Make : Honeywell/Schneider/Bosch
Supplying installation, Testing & Commissioning of The GUI based main network software must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’locations. The GUI software shall be located in control room in one of the blocks and shall monitor all the blocks panel connected with each other. Along with workstation complete all as specified and as directed.
Supply, install, Test and commissioning windowtype AC 1.5 TR capacity units complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating complete complete all as specified and as directed.
Supply, install, Test and commissioning windowtype AC 2.0 TR capacity units complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating complete all as specified and as directed.
Supply and fix Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V all as directed incl taking down old existing unsv enclosure complete all as specified and as directed.
Material and labour for submain wiring with 2 runs of 4 sqmm and one run of 4 sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable with proper colour coding drawn through and including non metalic PVC casing & caping not less than 25mm width ISI marked with all accessories like PVC elbow, PVC Tee etc fixed on wall complete including connecting up complete all as specified and as directed.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set with silent enclosures, fully prewired alternator AC to give an output of 160 KVA continuous rating at a PF of 0.8 lagging, 415 volts + 2.5% AC 3 phase 4 wire 50 HZ + 1% supply , 1500 RPM , directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank of capacity 360 Ltr (service tank) of adequate capacity with fuel line & accessories, vibration damper pads, control panel & other accessories etc complete all as specified and as directed.
(a) Diesel Engine with direct injection, water cooled engine, 6 cylinders, in line 4 stroke rated at 1500 RPM, conforming to ISO 3046/S5541 has the following specifications.
(i) Mechanical - FIP (ii) Mechanical- Governor/Electronic Governor (Optional) (iii) Turbocharger, Exhaust manifold, Stainless steel exhaust flexible connection (iv) Radiator cooled with turbocharged after cooled (v) Plate type lube oil cooler (vi) Filter - Fuel lube oil (vii) Dry type replaceable paper element air cleaner (viii) Flywhell housing and flywheel to suit single bearing alternator (ix) Starting Motor - Electric , Battery charging alternator (x) First fill lube oil and coolant
(b) Engine Electrical System :- Charging alternator voltage/Current (DC) - 12 Volt/35 Amp , Starter Motor rated voltage (DC) - 12 Volt & Battery voltage (DC) /Capacity (AH) - 12 V/120 AH maintenance free battery with lead terminals (Make of battery : Exide/AMRON)
(c ) Fuel System :- Recommended fuel- HSD & Fuel tank capacity (Ltr) -360 , Flexible fuel lines/SS fuel lines Fuel pressure Gauge/Fuel flow meter Note First fill of oil and diesel full tank during commissioning and 12 hours testing.
(d) Lubricating Oil System :- (i) Lub Oil sump capacity- 17 Ltrs (ii) Oil Change Period (Hrs) - 500, (iii) Oil consumption (% of SFC) < 0.2 (iv) Oil filter quanity (Nos/type) - 01 /Spin on type (v) Oil cooled Water Cooled.
(e) Cooling System : (i) Cooling system is designed for max ambient temp, Deg C at rated load - 50 (ii) Radiator System capacity including engine (L) - 40 Ltrs (iii) Water pump type - Centrifugal, gear driven
(f) Alternator Specification :- (i) Voltage 380 - 440 V (ii) Frequency - 50 HZ (iii) Current @ 0.8 PF (Amps)- 222.6 Amps (iv) Type - 4 Pole, Rotating Field (v) Exciter Type - Brushless (Permanent magnet Optional (vi) Leads Quantity , Type- 6 Fixed 12, Re connectable (Optional) (vi) Voltage regulator - Solid State (vii) Insulation - Class H (vii) Temperature rise- 125 Deg C (Class H) (viii) bearing quantity type - 1 Sealed (ix) coupling - Flexible disc closed coupled (x) Voltage Regulation : No load t full load - 2 phase sensing +- 1 % (xi) One step load acceptance - 100 % of rating (xii) unbalance load capability- 25 % of rated current
(g) Acoustic Enclosure : Engine alternator assembly mounted on AVM with silencer and S>S exhuast below suitably optimized to meet straingent sound & Emission standards as laid down by MOEF /CPCB (i) ase rail with draw cut type fuel tank is provided with a drain plug, air vent inlet and outlet connections, level indicators manholes etc (ii) sub Base fuel tank with 13 hours capaicty (iii) 12 volt dry , batteries with connecting leads and terminals 90 % gloss RAL 9003 white pure polyester powder coaed, base in black colour.
(h) AMF Control Panel (i) RAL 9003 white powder coated control Panel Manufacured with CRCA Sheet (ii) Water and lube oil drain outer located on the ourter surface- Leading to ease of maintenance and Cleanliness (iii) MCCB of suitable rating with short circuit protection (iv) Controller which displays voltage, current, KW, PF, frequency, KWH (v) Indicating lamps for Load ON and Set Running (vi) Current transformers of suitable ratings (vii) Aluminum busbars of suitable ratings capacity with incoming and outgoing terminations (viii) Control Fuses duly wired and ferruled (ix) Power cables Uninying copper conducator cables between alternartor & Control Panel inside the canopy.
(j) Generator controller (GCU 6120 - MKII) - (i) Compact and microprocessor based fully configurable control unit (Display Parameter- Engine Oil Pressure ) ( Audio Visual Warining- Low Oil Pressure ) (Shut down with audio - Low Oil Pressure (ii) Four line LCD Display - Coolant temp & High coolant Temp (iii) Rhe unique intergrated DG Set controller - Fuel level indication % & Low battery Voltage (IV) Incorporate both engine and alternator parameter in one console - Battery voltage , Low fuel Level & Engine under Speed (v) Fully configurable digital out put - Enigne rpMaterial and labour ow fuel level (vi) All parameter are settable and password protected - DG set running hours & over load etc
(k) Open Unit : Exhaust Silencer - Hospital/Residential grade, Stainless steel, Flexible Pope
(l) Literature :- Operation Manual General maintenance & Installation Guideline & Parts Manual
(m) Miscellaneous : Air cleaner (Heavy Duty/Air Cleaner Restrication indicator Digital/Closed crankcase ventilation .
Material and labour for RCC 1:2:4 (20 mm graded stone agg) type B1 Nominal mix as in foundations , Including rafts footing, foundation beams, plinth beams, bases for columns etc basement slabs under reamed piles and mass concrete including complete in PCC (1:2:4) type B-1 using 20mm graded with aggregate, cement plaster 15mm thick in cm 1:4), finishing the surfaces even & fair, making fixing arrangement with suitable nuts, bolts, vibrating pads all as per manufacturer’s instructions. (Size of foundations LXBXD ( 5 x 2.7 x 1.6 ) Mtr. complete all as specified and as directed.
Supply and fixing PVC insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 120 sq. mm 3.5 core with suitable accessories all as specified and directed by EIC.
Excavation in trenches n exc1.5m wide and n exc 1.5 min depth for foundation laying of cables shafts , manholes pier holes etc n exc 10 sqm on plan and n exc. 1.5 m in depth and getting out in loose/soft soil complete all as specified and as directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
Supply and layingreinforceced precast concrete cable cover, class LV type , I, flat size 250mmx150mmx40mm laid across the cable complete all as specified and directed.
Supply and install testing and commissioning of DC Supply LT panel board/Feeder Piller box In door type , dust and vemin proof, made out of 3.15 mm thick CRCA sheet with locking arrangement , both sides openable, having cable alley of suitable size for easy connection of cables , dust vermin proof suitable for 3 phase 4 wire 415 volt 50 Hz AC including suitable size copper conductor control wiring and powder coating with 7 tank process connecting the cable with necessary cable glands, lugs etc , proper arrangements for ventilation complete with and including cable glands and the following accessories :-
(a) Copper bus bar with PVC sleeve suitable for 630 amps for phase and 300 for neutral-01 set
(c) Phase indicating lamps LED type (Red, Yellow, Blue) - 03 set
(e) MCCB 400 A, 4 pole,36KA, Thermal magnetic DC Type-01 Nos (Incomer)
(f) MCCB 200 A,4P 25KA Thermal magnetic DC Type-02 Nos (Out going)
(g) MCCB 125 A,4P 16 KA Thermal magnetic DC Type-02 Nos (Out going)
(j) Changeover switch 315A - 01 No.
Supply and fixing in replacement of earth continuity conductor with adequate size saddle fixed to wall on batten or recess or any other indicated situation for loop earthing etc as required 32mm x 6mm copper Strip complete all as specified and directed.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl complete all as specified and as directed. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front and back openable doors having aluminium bus bar of capacity1200 amps for phases and 600 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, foundation, supporting channels,cable termination,cable gland etc complete all as directed and suitable to accommodate the following switch gears and meters :-
MCCB 630Amps, 4pole, 65KA - 01 Nos ( Incoming) (make C&sS cat No CSC6S4630) or equivalent in L&T, Legrand, ABB, Siemens, Schneider, Havells, Indo Asian
MCCB, 3 pole 300 Amps,37KA,Thermal magnetic- 2 Nos (Out going) (make C&sS cat No CSC5N3300) or equivalent in L&T, Legrand, ABB, Siemens, Schneider, Havells, Indo Asian
MCCB, 3 pole125 Amps,18KA,Thermal magnetic - 2 Nos (Out going) (make C&sS cat No CS3A3c125) or equivalent in L&T, Legrand, ABB, Siemens, Schneider, Havells, Indo Asian
MCCB, 3 pole 100 Amps,18KA,Thermal magnetic -05 Nos (Out going) (make C&sS cat No CS2N3100) or equivalent in L&T, Legrand, ABB, Siemens, Schneider, Havells, Indo Asian
Digital type Volt meter , digital type ,0 - 500V - 1 Nos
Digital type Ammeter, digital type with CT's - 1 No
indication lamps (R,Y,B) LED type - 1 set
Provn of Change Over Switch Capacity-315 Amp Qty-01
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as specified and as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
Material and labour for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC modular box with cover plate any size fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
(i) One light point controlled by one 5A switch
(ii) One Fan point controlled by one 5A switch
(iii) One 5A flush type switch socket point on same board board
(iv)One 5A flush type switch socket point on independent board
Material and labour for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC modular box with cover plate for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. (c)
Supply and fixing ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC.
Supply and fixing modular switch 1 way 6A,1 module all as specified and directed by EIC.
Supply and fixing modular switch 1 way 16A,1 module all as specified and directed by EIC.
Supply and fixing modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC.
Supply and fixing modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by EIC.
Supply and fixing for modular fan step regulator, 120W - 2 modular all as specified and directed by EIC.
Material and labour for Point wiring complete with PVC insulated, unsheathed cable, 1100 volts grade with multistranded copper conductor of 1.5 sq mm (FRLS) drawn through and including in stova enamelled steel conduit of suitable size fixed on wall including PVC insulated unsheathed multistranded copper conductor of size 1.5 sq mm (FRLS) as earth continuity conductor and connecting to common earth dolly including PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of suitable size all as specified & directed. Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green Make: Havells/ Finolex/ Plaza/Gloster
(b) One light point controlled by one 5A switch
Supply & fix CMRI certified LED flame proof 2x16W/20W LED tube light fitting complete all as specified & directed. Make CG cat No EXTN 2LT8-16/20 or equivalent in philips/surya/Havells/Bajaj
Supply and fixing switch flame proof rotary type with termination box in LM-6, single pole 250 Voltz complete all as specified as directed by Engr-in-charge. Note : As per STEC Pamphlet No 7
Supply and fixing in repair new generation recessed LED 4x1 Luminaire 36 watt CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting suitable for Gypsum ceiling complete all as specified & directed by EIC.
Supply and fixing in repair new generation slim recessed LED 2X2 Luminaire 36 watt CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified & directed by EIC.
Supply and fixing in repair of the ceiling light Suspended unique product with 15W LED bulb natural white colour rose gold finish & clear glass pendent complete including connecting up with two core white copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /C&S/Wipro/Benlo/Bajaj/ Jaguar cat No KCH-RDG-MD160030111A
Supply and fixing in repair of the wall lamp opal glass with chrome finish with natural white lamp 9W complete including connecting up with two core white copper conductor cable with suitable size and all as directed by Engr-in-Charge. Make : CG /C&S/Benlo/Bajaj/ Wipro/Jaguar cat No KCH-CHR-MB160275211A
Supply and fixing LED bulk head light fitting, 1x10 W luminaries protected to IP65, with front toughened glass including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and directed by EIC.
Supply and fixing in repair of MCB TPN DB 4 Way,415V with 200A busbar, double door type all as specified and directed by EIC. Note : DBs shall be concealed in wall where ever completely possible including making good the surface to match with surrounding.
Supply and fixing in repair of MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar all as specified and directed by EIC. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding complete all as specified and directed by EIC.
Supply and fixing in repair of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A all as specified and directed by EIC.
Supply and fixing MCB SP 6-32 Amps, 10 KA all as specified and directed.
Supply and fixing MCB SP 40 Amps, 10 KA all as specified and directed.
Supply and fixing MCB SPN 63 Amps , 10 KA all as specified and directed.
Supply and fixing MCB TP 63 Amps,415 volts, 10 KA all as specified and directed.
Supply and fixing in repairs of MCCB sheet metal enclosure for holding MCCB of up to 160 Amps capacity four pole type including fixing accessories etc complete all as specified and directed.
Supply and fixing MCCB FP 125 Amps,16KA, complete all as specified and directed.
Supply and fixing MCCB FP 100 Amps,16KA, complete all as specified and directed. all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised earth wire of size 4mm dia means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 5 of SSR part-I including welding with suitble electrode and testing complete all as directed. Note : 4mm dia GI wire shall be arc welded to GI plate electrode.
Supply and fixing galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter etc all as directed by EIC
Supply and fixing monoblock Pump set having capacity 5HP suitable for 415 Volt 3 Phase system including automatic star delta starter complete all specified and as directed
Supply and fixing monoblock Pump set having capacity 15HP suitable for 415 Volt 3 Phase system including automatic star delta starter complete all specified directed
Supply and fixing Submersible pump electric driven 415Volt TP suitable for 200/250 mm dia bore well (casing pipe site 200x 250 mm)supply and install complete 15 WHP Inclusive of 40mtr long submersible cable and including automatic star delta starter complete all specified directed
Supply and fixing Submersible pump electric driven 415Volt TP suitable for 200/250 mm dia bore well (casing pipe site 200x 250 mm)supply and install complete 11.25 WHP Inclusive of 40mtr long submersible cable and including automatic star delta starter complete all specified directed
Supply and fixing 7.5 WHP Pumping set Centrifugal. Electric driven supply and install commissioning and testing complete including automatic star delta starter and PCC Foundation complete all specified directed
Supply and fixing 22.5 WHP centrifugal Pumping set Electric driven with starter supply and installation, commissioning and testing complete including PCC Foundation complete all as specified and directed. Note for Sl Item No 62 to 67:- Old U/S starter and motors deposit to MES store yard
Dismantaling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Dismantaling asbestors cement and any type of corrugated semi-corrugated etc sheets in roof coverings complete all as specified and as directed
Excavation in post holes in hard/dense soil (or similar holes) each n.exc 0.5 mm getting out returning and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and directed
Material and labour for PCC 1:4:8 type D2 using (40mm graded stone aggregate) as in foundations, fillings & mass concrete etc all as specified and directed.
Material and labour for Framed work such as grills, gratings, chequered/plain plate,beam,rolled section framed, truss purline,rafter sun shed etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars, barred iron doors, ladders, farmed balastures, walk ways, railings, frame work of water tanks and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
Material and labour for preparing new or previously untreated steel surface of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
Supply and fixing pre-painted galvalume aluminium zinc coating Gl based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks as specified and as directed
Supply and fixing pre-painted galvalume aluminium zinc coating Gl based Plain steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks as specified and as directed
Material and labour brick work with sub class 'B' brick straight or curved on plan exe. 6 meters mean radius built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement including Neeru finish complete all as specified and directed
Material and labour for 1.5 mm thick galvanised steel sheet as in Valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope etc fixed with self tapping screw/J hooks and including scafolding upto any height complete all as specified and as directed by Engr-in-Charge
Dismantling of wall, wall panneling, partition and ceiling boards (fibre, pulp, insulation) or insulation boards, bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed
Supply and fixing false ceiling with powder coated exposed GI grid suspension system a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4 mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, complete all as specified and as directed.
Material and labour for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening on plastered surfaces complete all as specified and directed.
Material and labour for rendering 20 mm thick on fair faces of brick/concrete surfaces with two coats i.e (15 mm thick backing coat in CM (1:6) and 5mm thick finishing coat in CM (1:4)) ,mixed with 3% integral water proofing compound as per manufacturers instructions, finished even and smooth without using extra cement including all safety and scafolding complete all as specified and directed.
Material and labour for new or previously untreated surfaces of any description & applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof complete all as specified and directed
Material and labour prepration of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper on plastered/decorated wall surfaces complete all as specified and directed.
Material and labour for preparation of old wall surfaces of any description & applying one coats of acrylic (antifungal) exterior grade paint on wall/roof including scaffolding complete all as specified and directed
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .