Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.4 L+₹1.4 L (6.02%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹26.5 L+₹2.5 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.7 L+₹3.7 L (15.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹30.7 L+₹6.7 L (27.8%)Rejected-Finance H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Alwar
GE Alwar
REPAIR/CLEANING OF SEWAGE SYSTEM IN MD AND OTM ACCN UNDER AGE B/R-I AT CITY AREA ALWAR
2023_MES_598612_1
8175/E8
Open Tender
Civil Works
Item Rate
270 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹60,000
Yes
11 Jul 2023
26 May 2023
21 Jun 2023
26 May 2023
19 Jun 2023
8 Jun 2023
26 May 2023 - 7 Jun 2023
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above ground level) & removal of rubbish material complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving exc 15 cm thick above ground level & removal of rubbish material all as specified & directed.
M&L 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of path / hardstanding complete all as specified & directed.
M&L 60mm thick machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006, M-35 Grade and over 25mm thick sand complete all as specified and as directed.
M&L 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring complete all as specified & directed.
S&F glass dividing strips, 3 mm thick and 38mm width complete all as specified & directed.
Dismanlting of kerb stone including cement bedding & removed off rubblecomplete all as specified & directed.
M&L PCC type D2 1:4:8 (40mm graded stone aggregate) cement concrete in foundations, filling and mass concrete complete all as specified & directed.
M&L precast cement concrete solid block factory made as in Kerb stone in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) set in CM 1:6 (size of precast concrete block) complete all as specified & directed
M&L 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection finished fair and even complete all as specified & directed.
M&L coloured rubberized moulded chequered cement concrete tiles 30cm x 30cm x 18/19mm thick, set, jointed and pointed in neat cement slurry in floors over with and including 15mm thick cement screed in CM 1:6 complete all as specified and directed.
M&L 25mm thick, PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in sub base complete all as specified & directed.
M&L vitrified ceramic tiles 8 to 9 mm thick in light shade (square/rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over with and incl 15 mm thick cement screed in CM 1:6 complete all as specified and directed.
M&L non skid ceramic tiles colored 300mm x 300mm x 7mm thick in floor set and jointed in neat cement slurry and pointed in white or colour cement and over with and including 15mm thick screed bed in CM 1:6 complete all as specified & directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
M&L glazed ceramic coloured tiles in vertical surface 450mm x 300mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over with and including 10mm thick rendering in CM 1:4 complete all as specified & directed.
M&L glazed ceramic tiles in vertical surfaces 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L vitrified ceramic tiles 10mm thick (square/ rectangular) polished, coloured (light shade as approved), area of each tile n.exc 0.36 sqm, in wall, dado, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over with and including 10mm thick rendering in CM 1:4 complete all as specified & directed.
S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed.
S&F in repair white vitreous china wash hand basin 'Flat back' of size 550x400mm fixed on and including new brackets CP waste coupling and PVC Waste pipe complete all as directed.
S&F in repair vitreous China squatting pan, Orissa pattern, size 580mm x 440mm white with integral foot rests connection to trap and to flushing pipe, etc including making good to floor complete all as specified & directed.
S&F in repair vitreous China urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) alongwith preader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) complete all as specified & directed.
S&F in repairs PVC low level flushing cistern 10 ltrs capacity (white ISI marked) with inlet ball valve, float and handle, syphonic action type including brackets and flush pipe of polythelene of low or high density of PVC 32mm dia for LLFC complete all as specified.
Taking down cement plaster any description on brick or stone walls etc.
M&L rendering 15mm thick in CM 1:4 on stone / brick wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound all as specified.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick/stone masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L rough cast plaster on exterior walls applying the under coat of cement and sand morrtar 1:3 not less than 10mm thick and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm) mixed with coarse aggregate, sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered complete all as specified and directed.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces as in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed.
M&L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.
M&L preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified& directed.
M&L preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
Demolition of brick/stone masonry built in cement / lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified & directed.
M&L brick work with fly ash bricks {As per IS-13757 (1993) burnt clay fly ash building bricks}, (old size bricks) straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
M&L brick work with fly ash bricks {As per IS-13757 (1993) burnt clay fly ash building bricks}, (old size bricks) straight or curved on plan to any radius in half brick thick wall, built in CM 1:4 complete all as specified and directed.
M&L brick work with sub class B bricks, straight or curved on plan to any radius in old type brick thick walls built in CM in 1:4 complete all as specified and directed.
M&L walling of random rubble,bedded and solidely hearted uncoursed built in CM (1:6) complete all as specified and directed.
All as per item No 37.00 above but except stone complete all as specified and directed. Note:- Old serviceable stone obtained from item No 33.00 shall be used.
Extra over stone walling for hammer dressed to face stones and dressing of face beds and joints as specified of random rubble walling uncoursed or brought upto course with maximum depression on face from straight edge held against the depressed surface on lime or sand stone not exc 20mm for rock faced.
M&L providing cement concrete 1:2:4 type B-1 concrete (using 20mm graded stone aggregate) as in water throughs, surface channels of drains and manhole benching including finishing the top of benching even and smooth using extra cement complete all as directed.
M&L PCC 1:2:4 type B-0, (using 20mm graded stone aggregate) as in coping complete all as specified.
M&L plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin) corbels, brackets, etc. including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified& directed.
M&L providing precast cement concrete type B-0, 1:2:4 (using 12.5mm stone agregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar Set in CM 1:4 complete all as specified & directed.
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal to store
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal to store
S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor all as specified.
S&F steel tubing medium grade 20mm bore with all fittings fixed complete to wall and or laid in floor all as specified.
S&F in repair PVC connection of 15mm bore with 2 Nos PTMT nuts, 45cm long fixed with one end to pillar tap & the other end to stop cock or iron pipe all as directed.
S&F in repair Pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore all as specified.
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butter fly handle, fancy type chromium plated complete all as directed.
S&F in repair 15mm bore Stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union.
S&F in repair 15mm bore Stop/angle valves,fancy type chromium plated cast copper alloy screwed down high presure, screwed both ends for iron pipe or for unions complete all as specified.
S&F in repair chromium plated health faucet for EWC with including PVC Connection 1m long suitable for 15mm bore with all connected fittings.
S&F in repair Jet spray chromium plated brass for EWC with & including PVC connection 600 mm long suitable for 15 mm bore GI pipe with PTMT nut & nipple complete.
Cleaning of all blockages of Nahani trap/floor trap, bottle trap, gully trap, P or S traps of WCs, 100 mm/75 mm dia CI pipe stacks upto 1st Manhole, CI/SGSW pipe between gully trap & 1st Manhole, CI Tee/Door bends etc to maintain internal sewage system in the area of AGE B/R - I (City area) with and including manual/pressure cleaning pump & flexible rods and other necessary equipments complete all as specified and directed by Engr-in-Charge. Note : (i) Contractor or his authorised representative collect such type of complaints from AGE B/R - I complaint cell at 8.00 AM on daily basis except sunday /Holiday. No extra payment shall be made on account of collection of complaint. (ii) Complaint must be completed within 24 hours without any fail otherwise recovery shall be made double the market rate to the contractor.
Cleaning of sewage line of 100mm bore from gully traps, grease traps etc upto 1.5m deep by removing all filtn/silt, foreign materials and other deposit whatsoever completely and making the line free from all obstacles and testing the flow of sewer line evenly, smoothly by filling water. The cleaning operation will be carried out in suitable lengths by blocking the first and last manholes of sewage line and removing the silt/sludge & other deposits out side of MD land in covered van/trolley all as specified & directed.
All as per item No 57.00 above but sewage line of 150 mm bore and depth of sewage line upto 1.50m.
Cleaning of septic tank of any capacity or description including cleaning and pumping out fluid, cleaning of sludge from compartment of septic tank including intercepting chamber & washing down with water complete and removing the sludge in covered van/trolley out side the MD land, complete, all as directed.
Cleaning of manholes depth upto 1.5 mtr by removing all silt, sludge, any other materials making clean and flushing with water complete incuding removal of spoils out side MD land and taken out cover slab and reset in the same position after cleaning and testing all as specified and directed. cleaning shall be done either manually or mechanically as required and directed.
All as per item No 60.00 above but depth exceeding 1.5 m and not exc 3 m deep complete all as specified and directed.
Demolition of reinforced cement concrete as in cover /slab of manhole/septic tank/soakage well all a specified & directed.
M&L precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) for manhole cover including placing and set in CM 1:4 all as specified.
S&F 75mm thick steel fibre reinforced concrete (SFRC) manhole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 5 ton /Sqm in square rectangular or Circular shape complete all as specified and directed.
S&F 50mm thick steel fibre reinforced concrete (SFRC) manhole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 3 ton /Sqm in square rectangular or Circular shape complete all as specified and directed.
M&L mild steel (TMT bar) 6 to 8 mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for copying for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia.
M&L mild steel (TMT bar) 10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for copying for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia.
M&L use and waste of form work to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work, n.exc 200mm thick flat, rough finished surfaces of cencrete complete all as specified and directed.
M&L form wok to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, floor and roof n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide complete all as specifed and directed.
M&L M-25 RCC (using 20mm graded stone aggregate) as in slabs sopported on walls ,beams and columns in floors ,roofs, soak well, septic tank slab etc complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm dia (salt glazed ware AC or reinforcement concrete set in cement mortar.
M&L 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in concrete bed for 150 mm dia bore drain pipe for bed concrete including packing under and hunching against the sides of pipe after they are laid and tested complete all as specified and directed
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n.exc 1.5m in depth and getting out any type of soil complete
All as per item No 74.00 above exc 1.5m deep and n.exc 3 m deep.
Returning filling in including spreading, levelling watering and well ramming in layers not exc. 25 cm using excavated soil.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Cutting into existing manholes for new drains, for removing existing branch drain, making good to walling and rendering cutting out branch channel and making good benching (bore of pipe 150 mm).
S&F in repair 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors including dismantling old u/s pipe complete all as specified.
S&F in repair PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls with and including dismantling existing pipe complete all as specified & directed.
S&F in repair PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls/floor with and including dismantling existing pipecomplete all as specified & directed.
S&F in repair PVC (SWR) bends any radius 75 mm bore complete all as specified & directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore complete all as specified & directed.
S&F in repairs MS grating CP 100mm dia, with hole for waste pipe of approved make including fixing with CM to floor /nahani traps etc complete all as directed.
S&F PVC (SWR) vent cowl 110mm complete all as specified & directed.
S&F in repair 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified & directed.
S&Fin repair PVC (SWR),110mm junction single, (Single T) equal or unequal complete all as specified & directed.
M&L sealing the sides of traps in bath/kitchen using Aqua TS of "Aquashield water proofing" incl cleaning the traps with suitable chemical to remove foreign material all as required & directed .
M&L 300mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
Dismantling framed timber scantlings 40 sqcm and over in section, in any position complete all as specified.
S&F MS steel work in tubular trusses and tubular posts, purline, rafter including special shaped washers etc, complete using but welded. RHS/SHS confirming to IS 4923 : 1997 complete all as specified & directed.
S&F mild steel screw bolts dia of neck 5mm to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but n.exc 10cm long compleete all as directed.
M&L plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 W (Gde E-250) quality 'B' complete all as specified & directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
Dismantling asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified & directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified & directed.
shiva construction
M/s Laxmi Enterprises
M/S Naglot Enterprises
virendra constructions
J.J.ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .