Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-Finance JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | JAYKRISHNAPUR | HOOGHLY | WEST BENGAL | L1 | Accepted-Finance Lowest quoted amount | |
| 2 | L2₹4.1 L+₹18,927 (4.87%)Rejected-Finance 10 SATISH MUKHERJEE ROAD KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance Higher than lowest quoted amount | |
| 3 | L3₹4.1 L+₹20,014 (5.15%)Rejected-Finance 3 N K CHATTERJEE STREET KOLKATA 700 056 | KOLKATA | KOLKATA | WEST BENGAL | 700056 | L3 | Rejected-Finance Highest quoted amount | |
| 4 | Rejected-Technical 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | - | Rejected-Technical Rejected due to nonsubmission of shortfall documents |
Tender Value
Refer Docs
EMD Value
₹8,622
Closing Date
27 Feb 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE KCESD II PWD
OFFICE OF THE AE KCESDII PWD Beliaghata sales tax Complex Kolkta-15
AMC Electrical Installation GCECT Kolkata SITC of AC machines installation at 3rd floor Faculty room two room and Server Room Main Building of Govt College of Engg and Ceramic Technology Kolkata
2024_PWDE_667402_1
WBPWD/AE/30/Q/KCESD/II of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Govt College of Engg and Ceramic Technology Kolka
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,622
OFFICE OF THE AE KCESDII PWD
7 Sept 2026
15 Feb 2024
29 Feb 2024
15 Feb 2024
27 Feb 2024
21 Feb 2024
20 Feb 2024
Amount
SITC of 1.5 TR capacity wire HAT type R410A Split Air conditioner of rated cooling capacity of 18000 BTU/hr with 1 no. rotary compressor, 1 no IDU of rated power supply - 230 Volt - 1ph - 50 Hz, 1 no ODU of rated power supply - 230 volt - 1ph - 50 Hz. Air - flow : - 650 CFM. (Make - Hitachi) with remote control. Installation the outdoor, indoor unit & Connecting the pipe line testing the leack by nitrogen gas pressure (minimum 400 PSI )and vacuuming the unit properly (Minimum -30 PSI) by double stage vacuum pump, after release the gas testing the metal type HAT type Air conditioner. (Make : Hitachi /Daikin)
Refrigeration Piping: Installation and commissioning of hard / soft copper refrigerant piping, complete with fittings, elbows, bends, globe valve of suction & liquid line supporting arrangement on walls incl. S&F of 19 mm thick Nitrile Rubber Insulation tube (Make-Armacell/K-Flex) with supports & brackets as per direction of EIC. (a)5/8” dia 0.6mm Suction Line. (For 1.5 Tr & 2.0 Tr Machine)
(b) 1/4" OD with 0.6 mm thick Liquid Line.. (For 2.0/1.5Tr Machine)
Wrapping both the copper pipe with kenofoam sulation by 26 SWG aluminum sheet to make it vermin proof.
Supply & Charging Refrigerant - 410A
Supply and fixing fire retardant non porous flexible double canvas connection for concealed split air-conditioners.
Supply and laying communication screened Cu. Cable ( MK. KEI /Havell's / Polycab / Finolex/Gloster). (i)3- core 2.5 Sq.mm
Supply and laqying of necessary electrical arrangements 4 core x 2.5 mm² PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. ( MK. KEI /Havell's / Polycab / Finolex/Gloster)
Supply and fixing of Al. powder coated continuous Grill of requisite size & dimension as per direction of EIC.
Charges for construction of Trap Door for IDU of AC Machines for Maintenance purpose made of Aluminium Channel & Plywood of requisite size & dimension as per direction of EIC. (prior approval of drop ceiling design & material to be approved from EIC to be made before starting of construction) Dimension-4 feet x 2.5 feet.
Supply & Laying Drain Water piping work out of PVC/HDPE hard pipes with 6 mm thick nitrile rubber Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(Mk. Oriplast / Supreme) (i) 25mm dia
Supply & Fixing of Heavy Duty Anti-Vibration Pad for Isolation of Unwanted Vibration during the ODU in operation.
Supplying, fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm x 25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm having size of 600mm x 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer - in - charge.
Cool Point
P. M. COOLING AND ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.71 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .