Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 | |
| 2 | Progressive Builders L2₹21.1 L+₹2.0 L (10.4%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.0 L+₹3.9 L (20.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹26.5 L+₹7.4 L (39.0%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹29.4 L+₹10.4 L (54.3%)Rejected-AOC 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPAIR/MAINT OF HT DISTRIBUTION SYSTEM AND ALLIED WORKS IN NORTH AREA UNDER GE (U) E/M MEERUT CANTT
2020_MES_345374_1
93935/Mrt/2020-21/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Class D category b (ii)
7 documents required · 7 mandatory
₹500
GE (U) E/M Meerut
₹80,000
Yes
26 Jun 2020
16 May 2020
15 Jun 2020
17 May 2020
8 Jun 2020
1 Jun 2020
60 days
Amount
Dismantling of old ACSR conductor of any size/type from HT poles after proper taking of shutdown of respective feeder from respective power houses complete all as specified and directed.
M&L for aluminium conductor steel reinforces (ACSR) straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc of any type and sizes complete all as directed by Engr-in-Charge. Note : 3% conductor shall be measured extra for sagging
Dismantling of existing GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed.
M&L for cradles, heagonal/rectangular, fabricated with galvanised steel wire 4mm dia complete all as specified and directed by Engr in Charge.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolation of concrete excavation and earth work as reqd and removing the same form site complete all as specifed and as directed.
S&F stay assembly comprising of 7/10 SWG galvanised stay stranded wire of required length fixed to pole with and including flat iron clamp, bolts, nuts and washers, galvanised 14mm dia, 400mm long stay bow with 20 mm dia 180 cms, long stay rod with threaded end, GI nut & washers GI stay plate 230 x 230 x 6mm thick plate 2 Nos thimble, MS clamp made out of 50 x 6mm flat iron, loop insulator 90mm x 140mm dia hole, 25mm porcelain complete all as specified and shown in electrical plate No 1 of SSR Part I.
Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site complete all as directed.
S&F Disc type ,insulator porcelain, vitreous,brown white or green Two-in-series assembly, 145mm high &225mm dia ball & socket type, with tension clamp,single disc assembly for conductor working pressure 11000 volts complete all as specified and directed.
Supply and fix HT 11 kv, 150 mm height and 150 mm dia pin type insulator, porcelain, vitreous, white/brown/green, for 11000 Volts grade inclding one galvanised mild steel spindle, two galvanised iron washers and gavanised iron nut complete all as specified and directed.
Dismantling HT Danger notice plate from existing position and removing from site complete all as specfied and directed.
Suuply & Fixing 11000 Volts Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25X20cm size including taking down.
Dismantling of cross arms/ channel fixed on steel tubular poles carefully and removing from site complete all as specified and directed.
Supply & fix cross arms, channels,bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed by Engr-in-Charge.
Dismantling of old U/S rusted PCC pole /steel tubular poles of any size necessary disconnecting cables/over head conductor and removing unserviceable pole from site complete all as specified and directed.
Supply and errecting steel tubular pole swaged type 11.0 Meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc. Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m heightcomplete all as specified and directed by Engr-in-Charge.
PCC (1:3:6) type C2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work complete all as directed by Engr-in-Charge.
PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping/plinth of pole, finish the exposed surface even and smooth without using extra cement including necessary form work etc complete all as directed by Engr-in-Charge.
Taking out under ground cable 11000 volt grade of size 95 sqmm to 185 sqmm, 3 core from trenches, ducts floor, pipes and removing materials from site of work complete all as directed by Engineer-in-charge. ( Note: Excavation and earth work shall be measured and paid separately.
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
All as per item srl No 2 but in depth beyond 1.5 Mtr and n. exc 3.00 Mtr and taking out in any type of soil.
Returning, filling including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm, ISI marked complete all as specified and directed.
M&L ,XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (earthed) cable size of 185 Sqmm, 3 core including laying in trenches, fixing on wall complete all as specified and directed.
M&L ,XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (earthed) cable size of 120 Sqmm, 3 core including laying in trenches, fixing on wall complete all as specified and directed.
M&L ,XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade (earthed) cable size of 95 Sqmm, 3 core including laying in trenches, fixing on wall complete all as specified and directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) of 100mm bore for protection of under ground cable on poles/ walls/under road crossing etc including suitable size iron clamps with nuts, bolts & washers for proper fixing of pipe complete all as specified and directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) of 80mm bore for protection of under ground cable on poles/ walls/under road crossing etc including suitable size iron clamps with nuts, bolts & washers for proper fixing of pipe complete all as specified and directed.
M & L for boring in any type of soil under road 1.5 Mtr below the top surface of road by convential method complete for passing through 80mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separately . Any damage to existing cables of any type and road will made good by the tenderer without any extra payment.
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 50Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cable jointing kit for HT 11KV grade (Earthed) cable for straight through joint suitable for XLPE armoured aluminium conductor cable of 240 to 400 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit for HT 11KV grade (Earthed) cable for straight through joint suitable for XLPE armoured aluminium conductor cable of 120 to 185 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit for HT 11KV (Earthed) grade cable for straight through joint suitable for XLPE armoured aluminium conductor cable of 50 to 95 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination indoor type for HT 11KV grade cable for end termination jointsuitable for XLPE armoured aluminium conductor cable of 240 to 300 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination indoor type for HT 11KV grade (Earthed) cable for end termination jointsuitable for XLPE armoured aluminium conductor cable of 120 to 185 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination indoor type for HT 11KV grade cable for end termination jointsuitable for XLPE armoured aluminium conductor cable of 50 to 95 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade (Earthed) cable for end termination joint suitable for XLPE armoured aluminium conductor cable of 240 to 300 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade (Earthed) cable for end termination joint suitable for XLPE armoured aluminium conductor cable of 120 to 185 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint suitable for XLPE armoured aluminium conductor cable of 50 to 95 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Dismantling of old unserviceable GOD 11 KV and DO fuse unit of any type and capacity complete all as specified and directed.
Material and labour for switch air brake gang operated triple pole mechanically operated mounted on HT insulators(09 insulators type ), single breaking tilting type and MS galvanised steel frame with operating mechanisam worked from ground level including operating rod for current rating upto 200 Amps 11000 volts complete, locking arrangement MS clamps,bolts and nuts and washers required size to suit load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified.
Material and labour for switch air brake gang operated triple pole mechanically operated mounted on HT insulators(09 insulators type ), single breaking tilting type and MS galvanised steel frame with operating mechanisam worked from ground level including operating rod for current rating upto 400 Amps 11000 volts complete, locking arrangement MS clamps,bolts and nuts and washers required size to suit load at site including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified.
Supply & fixing DO fuse assembly, triple pole mounted on HT insulator 6 Nos and MS galvanised steel frame rating upto 200 Amp, 11000 Volt, post insulator type on channel (two insulator for one phase) complete with expulsion type fiberglass fuse carrier barral type and including DO fuze and electrical connections, jumpring by ACSR conductor and connectors.
Dismantling of UNSV HT lightening arrestor from the electric pole and removing from site complete all as specfied and directed.
S&F HT lightening arrestor for out door use expulsion type complete with all fittings,65 Kilo amps dicharge capacity, distribution class complete all as specified and directed.
M&L, Anti climbing device, spikes type fabricated out of MS bars (round squire and flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole complete all as specifed and directed.
Earthing complete with galvanized steel plate electrode 60cm X 60cm X 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanized strip 32 X 6mm size by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 40mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth strips connected to HT/LT equipment testing the earthing after completion all as specified and shown in electrical plate No 3 of MES SSR Pt- I 2009 print, complete all as specified & directed.
Earthing complete with galvanized steel plate electrode 60cm X 60cm X 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 15mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth strips connected to HT/LT equipment testing the earthing after completion all as specified and shown in electrical plate No 3 of MES SSR Pt- I 2009 print, complete all as specified & directed.
M&L, Triming of tree branches (tree prunning) up to 75mm dia to clear the route of HT/LT over head lines arround the 3 Mtr from the external conductors including removing the cut branches from site and depositing at places all as directed by Engeer in Charge.
M&L, Scraping, including cleaning and preparation of old surfeces of steel tubular pole 11 Mtr long including steel fitting complete and M&L for painting with two coat for aluminium paint after preparation of the steel surfaces of pole and steel structure of pole and steel strcutre fixed along pole and then applied strap with two coats black & white/yellow & Red paint in strap alternatively all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos writing pole no of letter size 2” by sign with white paint as directed by engineer in charge.
M&L,Surface Dressing/ Cleaning of surrounding area of 2/4 pole/pilinth TR structure including removing of tree branches small tree plants tarbushes etc complete all as directed.
M&L, Tightening and straightening of any type/size/span overhead line of ACSR conductor/ GI wire of any size and span by disconnecting and removing from insulators and tightening the conductor by using rope, chain pulley block etc and binding the conductor on insulators with and including binding wire and jumpers of ACSR complete all as directed by the Engr-in-charge.(Note: 3/4 run of ACSR conductor +2 run of GI wire of any size of length upto 40 to 60 RM will be measured as one span)
M&L, Re- adjustment and alignment cleaning of contact greasing and testing of out door type air break switch 11 kv current rating upto 200/400 Amps including all materials required for smooth functioning from ground level for AB/GO 11/33KV switch in fixing and replacement of unserviceable parts connections with and including lugs, GI nuts, bolts etc complete all as directed. (Note :- Replacement of unserviceable parts shall be measured and paid separately under relevant items)
M&L, Brass termianl plate for mounting male contact of AB/GO 11 KV 200 /400 Amp switch insulator in replacement of old unserviceable plate including GI nuts and bolts washers etc as required complete all as specified and directed.
M&L, Male contact for AB/GO 11 KV 200/400 Amp switch in replacement of unserviceable old male contact complete all as specified and directed.
M&L, Female contact for AB/GO 11 KV 200/400 Amp switch in replacement of unserviceable old female contact complete all as specified and directed.
M&L in repalcement Post insulator for AB switch with metal part sitable for HT 11 KV complete all as specified and directed.
M&L in replacement Post insulator double stack for AB/GO 11 KV with metal part complete all as specified and directed.
M&L in repacement DO insulator suitable for 11 KV with metal part complete all as specified and directed.
Finding out the cable fault of any size and any capacity of cable from LT 1100 Volt grade to 33000 KV with the help of cable fault loacator and with Necessary disconnection of cable from two ends and connection after repairs and having the following items with electrician at site up to length of 0.5 KM cable complete all as specified and directed by Engr-in-Charge:- (a) Surge Generator with accessories-01 Nos (b) Head Phone- 01 Nos (c) Pin Point set T-505 with accessories- 01 Nos (d) Earthing cable with clamp-01 Set (f) Cable fault locator T-905 with accessories -01 Nos (g) TC-808 with accessories -01 Nos (h) Soldering Iron-01 Nos (j) Plier- 01 Nos (k) Soldering paste -01 Nos (l) Capacitor Unit -1 Nos (m) Capacitor connecting cables-01 Nos (n) Power cable-01 Nos (o) Nose plier -01 Nos (p) Card for SSG -1100-01 Nos. Note:- Transportation charge for shifting cable fault locater will deem to be including in above send job and nothing extra on this account will be admissible.
M&L for opening of jumpers of 11 KV OH line at cut points and incoming/outgoing of GOD , DO and refixing properly with new ACSR conductors (Farret) and 3 phase 3 wire will be considered as one job complete all as specified and directed by Engr-in-Charge.
Progressive Builders
Microsys Controls India
BASANT RAM AND SONS
Vishal Traders
Jain Traders
SURAT SINGH AND SONS
GEPS PROJECTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .