| 1 | L1₹40.4 LAccepted-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹45.1 L+₹4.3 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹50.2 L+₹9.3 L (22.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
11 Jan 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/ MAINT OF ROOF TREATMENT INCLUDING REPAIR TO ELECTRICAL APPLIANCE SUCH AS CEILING FAN EXHAUST FAN GEYSERS AND CERTAIN MISC E/M WORK IN PRATAP CHOWK TAURAS ENCLAVE ARJAN VIHAR AND OTHER ADJOINING AREAS OF AGE B/R-II UNDER GE CENTRAL DELHI CANTT
2022_MES_558153_1
GE/C-63/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
24 Jan 2023
17 Oct 2022
13 Jan 2023
17 Oct 2022
11 Jan 2023
31 Oct 2022
17 Oct 2022 - 31 Oct 2022
Amount
Dismantling of brick tiles or terracing tiles single layer on roof and removing the rubbish outside complex (MOD land),incl removal of vagitation if any upto G+5 storey bldg complete all as specified.
Demolition of mud in roof, any thickness, including mud plastering and mud phuska under brick tiles at any situation and height, upto G+5 storey bldg incl removal of mtrls upto 1.50 km away from defence land complete all as specified.
M&L for 15mm average thick (average) rendering in cement mortar 1:4 using WPC on roof surfaces & finished even and smooth with using extra cement and applying two coat of building grade bitumen 85/25 @ 1.2 Kg/Sqm in each layer in any position upto G+5 storey bldg complete all as specified.
M&L for ready mix plaster of 15mm thick rendering on top of roof surfaces incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer instruction.upto G+5 storey bldg complete all as specified.
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints upto G+5 storey bldg complete all as specified.
M&L for applying two coat of silver Shield BITUMINIOUS paint on app membrane complete all as specified and directed by Engr-in-Charge.
M&L for heat resistant tiles of size 300x300x 9mm thick with solar effectivereflectance =0.7567, emissivity= 0.935 made from screened ground minerals blend with fiber bonding agent compound and other chemicals with high emissive and water proofing complete all as specified and directed.
M & L Cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs, coping/ coving or mud stops etc including weathering slightly rounded or chamfered edges, finished even and smooth without using extra cement complete all as specified.
M & L for 15mm bore GI tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc incl, cutting chases in wall where ever required and then making good including dismantling of old GI tubing complete all as specified and directed.
M & L for 20mm bore GI tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc incl, cutting chases in wall where ever required and then making good including dismantling of old GI tubing complete all as specified and directed.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 500 litres and n.exc 1000 litres capacity of any condition or type incl complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position, upto G+5 storey bldg complete all as specified.
Brick work with old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), upto G+5 storey bldg complete all as specified.
All as per serial item No 13 but except bricks, all as specified. (Servicable bricks retrieved from Serial Item No 01 shall be used).upto G+5 storey bldg complete all as specified.
Taking down cement plaster in any thickness from brick or stone etc including raking out joints, hacking for key, scrubbing down with water etc upto G+5 storey bldg complete all as specified.
M&L for ready mix plaster of 15mm thick on brick or conc surfaces incl necessary cement slurry with bulk density 1.40 to 1.70 kg, water ratio 17 to 19% by weight & compressive strength as per IS 4031 part 6 applied as per manufacturer instruction.upto G+5 storey bldg complete all as specified.
Preparation of newly plastered surfaces of walls and applying two coats of Apex over a coat of primer, complete all as specified and as directed.
Disconnecting existing water tanks, setting aside (or lowering if required) for cleaning,repairing and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes and reconnecting and refixing in position for tanks capacity exc 500 and n.exc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including refixing the same after necessary repairs/ replacement of unserviceable/ wornout part and testing as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note : Spare parts suchg as blade, canopy, ball bearing, gun metal bush, shaft, exhaust fan motor etc. shall be measured and paid seperately under relevent of supply only.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as specified and directed by Engineer-in-Charge. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm 1400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete including taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of Exhaust fan 225/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete including taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as per item No 22 above but 450 mm sweep complete including taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of wall mounted fan 250/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete including taking down and testing of the wall mounted fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as per item No 24 above but 600 mm sweep Almonard fan in 61 CAV Stable complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
Supply only Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge. (As per sample)
Supply only exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample)
All as per item No 27 but 450mm sweep complete all as specified and directed.(As per sample)
Supply only PVC fresh air fan blade suitable for 250/200 mm size with all fixing accessories complete all as specified and directed by Engineer-in-Charge.
Supply only canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample) complete all as specified and directed by Edngineer-in-Charge.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor of 1.0 MFD complete all as specified and directed by Engineer-in-Charge. Make : Orient/Epcos/Havells.
S&F in replacement capacitor of 2.5 MFD complete all as specified and directed by Engineer-in-Charge. Make :Orient/Epcos/Havells.
S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge. Make : Orient/Epcos/Havells.
S&F in replacement capacitor 4.0 MFD complete all as specified and directed by Engineer-in-Charge. Make : Orient/Epcos/Havells.
S&F in replacement capacitor 6.0 MFD complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing No. 6203 complete all as specified and directed by Engineer-in-Charge.
Supply only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Engineer-in-Charge.
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 230 mm size exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan (Metal body) 300mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete and making holes for fitting etc complete all as specified and directed by Engineer-in-Charge.
S&F fresh Air fan 250mm sweep with louvers including connecting with suitable size of copper conductor from ceiling rose to fan complete all as specified and directed by Edngineer-in-Charge.
Supply & Fix fan regulator electronic type 5 steps connecting complete all as specified and directed by Engineer-in-Charge.
Supply & fix Modular five stepped type electronic fan regulator 100W,2 module 360 degree rotatable type 230V AC complete all as specified and directed by Engineer in charge.
S&F of modular 25 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘B’ curve, single phase 240 V, AC including modular frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge.
M&L for fixing in replacement safety pressure valve (as per sample) for geysers complete all as directed by Engineer-in-charge.
S&F in replacement SS braided pipe of 12 mm (internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element of 2 KW,(as per sample) with nut bolt washer complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element of 1.5 KW (as per sample) with nut bolt washer complete all as specified and directed by Engineer-in-Charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engineer-in-Charge.
M & L neon lamp/indicator lamp for geysers complete all as specified and directed by Engineer-in-Charge.
M&L plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 3 above) complete all as specified and directed by Engineer-in-Charge.
Supply only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and directed by Engineer-in-Charge.
Supply only inner Steel tank for geysers of capacity 50 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
Supply only inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
Supply only outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) complete all as specified and directed by Engineer-in-Charge.
Supply only top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade complete all as specified and directed by Engineer-in-Charge.
Supply only bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
M & L in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
S & F sheet metal enclosure with 2 pin and earth plug and socket complete with and including MCB 20 Amps 240 volts heavy duty complete all as specified and directed by Engineer-in-Charge.
M&L of modular AC Box consisting of 25 Amp multipower socket including MCB of capacity 25 Amp mini MCB, ‘C’ curve, single phase 240 V, AC including modular metal box, frame, cover plate including plug top with indicator complete all as specified and directed by Engr-in-Charge
S&F factory made epoxy powder coated Distribution Board TPN 4 ways (TPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN MCCB 125/160 Amp as incomer and 12 SP or 4 No TP MCBs as outgoing complete all as specified and conforming to IS : 8623 complete all as specified and directed by Engineer-in-Charge.
S& F in repairs sheet metal enclosure one way for independent mounting of 4 pole MCCB, incl MCCB 4 pole 250 Amp 25 KA, 415 Volts complete all as specified and as directed by Engr-in-Charge.
Supply & Fix in replacement MCCB 160 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 125 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 100 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 63 Amp,16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCCB 250 Amp, 16 KA, 415 Volts 4 pole with copper lugs complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement MCB SPN 32- 63 Amps, 240 Volts, 10 KA capacity C' curve complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SP 6-32 Amps 240 volts curve 'C' series 10 KA 50 HZ complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 (using 20mm aggregate) Type B-1 as in leveling course using WPC finished even and smooth without using extra cement as directed by Engr-in-Charge.
Schedule of Credit
POONAM ENTERPRISES
M/s SAAR ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .