Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.8 L+₹1.7 L (5.92%)Rejected-Finance HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.4 L+₹4.2 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.4 L+₹5.3 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.4 L+₹7.2 L (25.6%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Jun 2022, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
REPAIRS TO WALL SEEPAGE / DAMPNESS AND CERTAIN CONNECTED B/R NATURE WORKS OF MD AND OTM ACCN UNDER AGE B/R-I OF GE (WEST) AGRA
2022_MES_507886_3
8012/868/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST AGRA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE WEST AGRA
₹70,000
6 Jul 2022
6 Jun 2022
16 Jun 2022
6 Jun 2022
14 Jun 2022
6 Jun 2022
Amount
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Cutting, chases, pinning in of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring,brick wall etc cutting exc 20cm girth complete all as specified & as directed.
M & L APP based polymeric membrane minimum weighing 3kg/sqm and min 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gm/sqm) land on primed surface by forced application complete all as specified.
M&L PCC 1:2:4 type B1 using 20 mm graded aggregate with integral water proofing compound as per manufacturer instruction finished fair and even in lintels upto 1.5 m clear span, cills steps siesmic and other similar bands, plinth courses etc as directed (Note: WPC will be measured and paid separatly)
M&L for rendering 15mm thick plastering in CM 1:4 on fair faces of brick or concrete surface with water proofing compound as per manufacturers instructions and finishing the surface even and fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M&L for rendering 15mm thick plastering in CM 1:4 on other than fair faces of brick or concrete surface with water proofing compound as per manufacturers instructions and finishing the surface even and fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying two coats of oil bound distemper over a coat of average 1mm thick Birla putty complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant priming paint on wall complete all as specified and directed.
M & L for applying two coats of water proofing coating liquid by brush applying in wall surfaces all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for brick work with sub class ‘B’ bricks old size (EXCEPT BRICKS), straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed. Note:- Bricks obtained from item No 1 shall be reused after cleaning.
M&L washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified. (Payment for providing grooves shall be made separately)
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and directed.
Cutting the roots of trees from the brick walls/stone wall made in cm exc half and not exc one brick thick and making good the disturbed surfaces including coating of paving hot bitumen to arrest further growth to the roots including repair existing surfaces with cm 1:3 or PCC 1:2:4 complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed.
S&F 15mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Refixing old steel water tubing 15mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
S&F 20mm bore steel water tubing medium grade galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Refixing old steel water tubing 20 mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F in repair 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
M & L cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sq cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
S&F mild steel joist channel angle or tee sections fixed independently with out connecting plates etcof grade fe-410-0 & fe 310-0 complete all as specified and directed..
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L cement concrete type B-1, 1:2:4 mix ( 20 mm graded agg) in padding, roof kerbs or mud stops, rounded or chamfered on edges and similar work incl necessary formworkall as specified and directed.
Dismantling PVC water tank of capacity 500 lit complete all as specified & as directed.
Dismantling PVC water tank of capacity 1000 lit complete all as specified & as directed.
M&L rotational moulded polyethene water storage tank (cylindrical / vertical with closed top) 500 ltr capacity, triple layes, hoisted and fixed in position with threaded PVC lid, nipple of suitable size complete all as specified & as directed.
M&L rotational moulded polyethene water storage tank (cylindrical / vertical with closed top) 1000 ltr capacity, triple layes, hoisted and fixed in position with threaded PVC lid, nipple of suitable size complete all as specified & as directed.
M&L 20mm bore ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified & as directed.
M&L in repairs 20mm bore ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified & as directed.
SHRI RADHAYSHYAM JHA
M/S DEVENDRA KUMAR GUPTA
R.S BUILDERS
Attar Singh and Sons
C P Singh and Co
JWALA ELECTRIC CONTRACTORS
M/s J S & SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .