| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹26.6 L+₹2.5 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹26.6 L+₹2.6 L (10.9%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹28.4 L+₹4.4 L (18.3%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹31.0 L+₹7.0 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
REPAIR/MAINT AND REPLACEMENT OF STREET LIGHTS/FLOOD LIGHTS AND CONNECTED ACCESSORIES AT CENTRAL AREA AND DUNKRIK LINE AREA UNDER AGE E/M-I AT GE (C) KHADKI.
2024_MES_661635_1
8938/E8 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CENTRAL AND DUNKRIK LINE area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹80,000
Yes
12 Nov 2024
24 Jun 2024
23 Jul 2024
24 Jun 2024
18 Jul 2024
12 Jul 2024
24 Jun 2024 - 4 Jul 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cables, pole foundation, stays etc and getting out in soft loose soil, complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed by Engr-in-Charge
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge
Material and labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed by Engr-in-Charge
Material and labour for PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed by Engr-in-Charge
Material and labour for road cutting upto 300mm deep and 200mm wide for crossing GI water pipe line through road including making good the disturbed surface by filling mass concrete 1:3:6 type C2 complete all as specified and directed by Engr-in-Charge. NOTE :- Mass concrete will be measured and paid as saperate item.
Material and labour for fine stone dust for cousioning of UG cable/ at cable trenches / inside substation building complete all as specified and directed by Engr-in-Charge.
Material and labour for brick protection with sub class 'B' brick for UG cable complete all as specified and directed by Engr-in-Charge.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205& 14930 (Part-I and Part-II ) for protection of undeground cable of size 40 mm outer dia with all fittings such as clamps, coupler etc laid in trenches/roads/nallah or fixed along wall/poles or laid under floor (including cutting floor/road and making good to match with existing adjoining surface etc for cable protection all as specified (excavation and earth work shall be measured and paid separately) MAKE :- Alcorr/Rex/Gemini
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying / refixing or carrying to store for Sch of Credit complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core with required aluminium cable lugs, heat shrink joints, Colour code heat shrink sleeves at both cable ends complete all as specified and directed by Engr-in-Charge MAKE :- Polycab/Asian/Finolex/Grandlay
Description all as per item No. 11 above but 10sqmm 2 core cable complete all as specified and as directed.
Description all as per item No. 11 above but 16sqmm 2 core cable complete all as specified and as directed.
Description all as per item No. 11 above but 10sqmm 4 core cable complete all as specified and as directed.
Description all as per item No. 11 above but 16sqmm 4 core cable complete all as specified and as directed.
Description all as per item No. 11 above but 25 sqmm 3.5 core cable complete all as specified and as directed.
Dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing or carrying to store for credit, complete all as specified and directed by Engr-in-Charge
Supply and fix steel tubular swaged pole complete with cast iron base plate , finial taper plug bolts nuts and screws confirming to IS : 2713 and made out of structural steel tube confirming to IS: 1161 and painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type 410 SP-31 (9 mtr long). complete all as specified and directed by Engr-in-Charge
Supply and fixing cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed including taking out old and unsv items carrying to store or for credit schedule, complete all as specified and directed by Engr-in-Charge
Supply and fix earth continuity wire using GI wire not less than 4mm dia on pole incl dismentling taking out unsv GI wire complete all as specified and directed by Engr-in-Charge
Dismantling and taking down old/unsv ACSR conductor any size complete for reuse at site or carrying to store for Sch of Credit all as specified and directed.
Supply and fix ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as specified and directed. MAKE :- M/s All Ind, ICC, M/s Bharat Conductors, M/s NICCO and M/s Indian Aluminium co
Material and labour for painting of steel pole any type up to 7.5 mtr height above ground level including cross arms,clamps,stay clamps, brackets, swan neck etc with two coats of aluminium paint after surface preparation complete all as specified and directed by Engr-in-Charge
Material and labour for numbering of LT poles serially with letter/number size width and height up to 40 mm in situ with black paint on white back ground all as directed by Engr-In-Charge.
Supply and fix GI tubing light grade 40mm bore,on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection, complete all as specified and directed by Engr-in-Charge
Supply and fix GI tubing light grade 50mm bore on pole /wall with necessary clamps, nuts, bolts and washers/under road cross ISI marked, for cable protection, complete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of old unserviceable LED security fitting 45 watt with LED driver and lens complete with suitable size bracket made of GI Pipe Light grade, clamps, nut, bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. NOTE :- The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: TRP-417-45-57-SL-LM-NBK or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED security fitting 60 watt with LED driver and lens complete with suitable size bracket made of GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge.NOTE: The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: TRP-421-60-57-SL-LM-NBK or techno commercial equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED security fitting 70 watt with LED driver and lens complete with suitable size bracket made of GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge.NOTE: The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: TRP-421-70-57-SL-LM-NBK or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED security fitting 90 watt with LED driver and lens complete with suitable size bracket made of GI Pipe Light grade, clamps, nut, bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable from junction box of pole incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. NOTE :- The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: TRP-425-90-57-HL2-LM-NBK or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED flood light fitting 80 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. NOTE :- The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: LFL-80-CDL/60M or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED flood light fitting 100 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. NOTE :- The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: CFS-504-100-57-60D-SL-GL-NSG or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED flood light fitting 120 watt with LED driver and lens complete with all fittings incl 1.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. NOTE :- The contractor must produce the IK10 and LM79 - LM80 test report of the batch of fittings before installation. MAKE :- CG Cat no: LFLN-120CDL/60M or techno commercial Equivalent in Philips/Wipro.
Supply and fix in replacement of old unserviceable LED Highbay light fitting 100 watt, 230 V with lens complete with all accessories and including connecting upto ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener etc all as specified and directed by Engr -in-Charge . MAKE :- Surya Cat part-SLE HB 100W COMET NEO -N or techno commercial Equivalent in Philips/Wipro
Supply and fix in replacement of old unserviceable LED Highbay light fitting 120 watt,230 V with lens complete with all accessories and including connecting upto ceiling rose with 0.5 sqmm three core copper flexible conductor cable,One GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener etc all as specified and directed by Engr -in-Charge . MAKE :- Surya Cat part-SLE HB 120W COMET NEO -N or techno commercial Equivalent in Philips/Wipro
Supply and fix in replacement of old unserviceable LED post top lantern 25 watt complete with 40/50 mm GI Pipe Light grade, clamps, nut, bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no CBP-610-25-57-SL-CA-NBK or techno commercial Equivalent in Philips/Crompton Greaves/Jaguar.
Supply and fix in replacement of old unserviceable LED post top suspended lantern 60 watt made up of die cast aluminium housing, polycarbonate diffuser, power coated IP-65 complete with all fittings, incl three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- Jaguar Cat No: LGTP08X060XW or techno commercial Equivalent in Philips/Surya.
Supply and fix in replacement of old unserviceable LED post top lantern 40 watt complete with 40/50 mm GI Pipe Light grade,clamps,nut,bolt and washers, incl 1.5 sqmm three core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: LPTC-40-WW or techno commercial Equivalent in Philips/Wipro
Supply and fix in replacement of old unserviceable LED Bollard light with optically design reflactor and indirect-direct, downward directional, high performance, smartly designed asymmetric lighting landscapes of 11 watt ,230 Volt AC with all fittings complete on PCC foundation all fittings complete all as specified and directed by Engr-in-Charge.. MAKE :- Wipro Cat no: LB13-131-XXX-65-08 or techno commercial Equivalent in Philips/Jaguar .
Supply and fix in replacement of old unserviceable LED Bollard light, Tripod type made of extruded aluminium housing to redefine landscape with better light quality and enhance architectural design, rated IP-65 of 10 watt, 230 Volt AC with all fittings complete on PCC foundation complete all as specified and directed by Engr-in-Charge. MAKE :- CG Cat no: LBLSN-10-CDL/WW or techno commercial Equivalent in Philips/Jaguar.
Supply and fix in replacement of old unserviceable LED Bollard light with robust design and efficient light distribution of 10 watt, 230 Volt AC with all fittings complete on PCC foundation all as specified and directed by Engr-in-charge. MAKE :- CG Cat part no- LBLSR-10-CDL/WW or techno commercial equivalent in Philips/Wipro/Jaguar.
Supply and fix in replacement of old unserviceable LED garden light compact and aesthetic polyester coated aluminium housing in ground/bushlight offers safe and vibrant parking area, pathway and gardens with high illumination and soothing experience of 8 watt ,230 Volt AC with all fittings complete all as specified and directed by Engr-in-Charge. MAKE :- Wipro Cat no: LF05-600-036-27-XX or techno commercial Equivalent in Philips/Jaguar .
Supply and fix in replacement of old unserviceable LED building security light 25 watt, 230V with lens complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20/25mm dia bracket of total length 50 to 80 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed. MAKE :- CG, Cat Part No-CBP-610-25-57-SL-CA-NBK or techno commercial equivalent in Philips / Wipro / Jaguar
Supply and fix in replacement of old unserviceable bright light 8 inch Milky Doom, round shape outdoor type including taking down unserviceabble complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed by Engr-in-Charge MAKE :- Hensel Cat No.DK 2525 G
Supply and fix in replacement of old unserviceable LED driver suitable for 25, 35, 45 & 60 watt LED security light including taking out defective driver any type, complete all as specified and directed by Engr-in-Charge. MAKE :- CG/Wipro/Havells
Material and labour for timer dial type suitable for panel mounting including taking out old and unservicable time switch any type any size complete all as specified and directed by Engr-in-Charge. MAKE :- L&T/Legrand or equivalent.
Material and labour for 3 pole contactor, 240 volts,50 HZ up to 415 volt 50 Hz, complete all as specified and directed by Engr-in-Charge. MAKE :- L&T/Legrand or equivalent.
Supply and fix Surge protector suitable for 25, 35,45/60 watt LED security light including taking out defective Surge protector any type. complete all as specified and directed by Engr-in-Charge.
Material and labour for three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through PVC Conduit incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. MAKE :- Polycab/Finolex/Havells
Material and labour for rigid non-mettalic PVC conduit of siz 20mm inclusive of all fittings i.e. tees,bends,elbows, bell mount tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc complete all as specified and directed by Engr-in-Charge
Material and labour for restraining of overhead ACSR conductor of any size of 4 wire 35-40 metre span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of ACSR conductor of any size of 2 wire 35-40 metre span on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of GI Cradle guard hexagonal/rectangular of any size on 35-40 metre span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engr-in-Charge.
Material and labour for restraining of GI earth wire of any size 35-40 metre span on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P complete all as specified and directed by Engr-in-Charge
Cutting/Trimming of tree branches around 3.00 m distance from conductors of LT over head line of span up to 40 meters including removing of creepers/vegitation etc from poles complete all as specified and directed by Engr-in-Charge.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay for reuse at site or carrying to store for sch of credit complete all as specified and directed.
Supply and fix pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fix shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed by Engr-in-Charge.
Supply and fix Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm complete all as specified and directed by Engr-in-Charge
Supply and fix Heat shrink straight through joint LT 1100 volts grade 6 sqmm, 2 core, complete all as specified and directed. MAKE :- Raychem, Cat No-EPKJ0081 or techno commercial equivalent of M-Seal/Birla-3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 2 core, complete all as specified and directed. MAKE :- Raychem, Cat No-EPKJ0081 or techno commercial equivalent of M-Seal/Birla-3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 10-16 sqmm, 4 core, complete all as specified and directed. MAKE :- Raychem, Cat No-EPKJ0123 or techno commercial equivelant of M-Seal/Birla-3M
Supply and fix Heat shrink straight through joint LT 1100 volts grade 25-50 sqmm, 4 core, complete all as specified and directed. MAKE :- Raychem, Cat No-EPKJ0130 or techno commercial equivalent of M-Seal/Birla-3M
Labour for disconnecting LT cable of any size from DBs/Panel/pole/transformer for finding fault , Material and labour for defect rectification. LT cable laid in trenches or any location by detecting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge all as specified and as directed. NOTE :- (i) complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs. 500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, (ii) Relaying of sand and protective cable covers are deemed to be included in the quioted rate. Joint kit will be measured seperately in appropriate item in this schedule
Labour only for disconnecting LT cable of any size from pole (height 7.5 to 9 mtr) /transformer panel and re-connecting of cable at both end after removing carbon /burnt insulation part of cable by cutting refixing cable with new cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge as specified. NOTE :- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs. 500/- per day complaint will be recoverd.
Material and labour for earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at 1.25m below ground level after making bore hole of size not less than 300 mm dia using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary earth work returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Material and labour for earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at 1.25m below ground level after making bore hole of size not less than 300 mm dia using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 32x6 mm strip all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 40 mm light grade GI tubing for protection of GI strip 32x6mm, charcoal and salt in alternate 150 mm thick layers around GI earth pipe, including necessary earth work returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Supply and fix in repair MCB, Double Pole 5 to 32 amps, 240 Volts, 10 KA ‘’C” curve complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4086-09 to 4086-17 or equivalent Schneider / ABB
Supply and fix in repair MCB, Single Pole, 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4085-87 to 4085-95 or equivalent Schneider / ABB .
Supply and fix in repair MCB TPN 40-63 Amps, 415 volt 10 KA, complete all as specified and directed by Engr-in-Charge MAKE :- Legrand cat part No 4086-59 to 4086-61 or equivalent Schneider / ABB
Supply and fix in repair Automatic street light switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light. The sensor (Nature Switch) along with suitable Power contactor, MCB and support Terminals should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof,Termite proof and FR grade special moulding compound (Sintex make SMC junction box) conforming to IP54. The contactor, MCB and circuit wiring should suitable enough to take load of 8 kW single phase load, Contactor rating :40Amps (2-pole), MCB (Single pole) Rating 63 Amps (2 Nos) complete all as specified and directed by Engr-in-Charge. Nature Switch : Kakatiya Energy System Ltd, Hyderabad, Model : SWADEEP -02C8KW1P
Supply and fix in repair Automatic street light switch using NATURE SWITCH for automatic switching of street lights based on LUX level of natural light. Th sensor (Nature Switch) along with suitable Power contactor, MCB and support Terminals should be enclosed in pole/wall mountable enclosure made of Rust proof, Electric shock proof,Termite proof and FR grade special moulding compound (Sintex make SMC junction box) conforming to IP54. The contactor, MCB and circuit wiring should suitable enough to take load of 12 kW load equally distributed over three phase load, Contactor rating :40Amps (4-pole), MCB (Single pole) Rating 63 Amps (3 Nos) complete all as specified and directed by Engr-in-Charge Nature Switch : Kakatiya Energy System Ltd, Hyderabad, Model : SWADEEP -02C12KW3P
Supply and fix in replacement for PVC insulated, PVC sheathed twin core 1100 volts grade, 10 sqmm aluminium stranded conductor (incl PVC conduit/wire guard where required) complete all as specified and directed by Engr-in-Charge. MAKE :- Finolex/Polycab/RR cable
Description all as per item No. 73 above but size of cable 6 sqmm.
Description all as per item No. 73 above but size of cable 4 sqmm size.
Description all as per item No. 73 above but size of cable 2.5 sqmm size.
Om Construction (BID ID -3066143)
VP DEVELOPERS AND CONTRACTOR (BID ID -3066640)
JP ENTERPRISES (BID ID -3064975)
MAYUR ELECTRIC SERVICES (BID ID -3065927)
MANGAL ELECTRICAL STORES (BID ID -3066705)
SKS Electricals (BID ID -3066706)
Rama Electricals (BID ID -3066473)
ASHWAMEDH ENGINEERS (BID ID -3066599)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .