Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 2 102A SREE COLONY KOLKATA 700092 | KOLKATA | KOLKATA | WEST BENGAL | 700092 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹8.5 L+₹54,830 (6.86%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹9.0 L+₹97,965 (12.3%)Rejected-Finance | L3 | Rejected-Finance EMD TO BE REFUNDED |
Tender Value
Refer Docs
EMD Value
₹16,633
Closing Date
19 Jan 2021, 3:00 pmClosed
EXECUTIVE ENGINEER
1ST ADMINISTRATIVE BUILDING, CITY CENTRE, DURGAPUR
Electrical Work
2021_ADDA_315021_1
ADDA/DGP/ED/N-33/2020-21(SL-1)
Open Tender
Electrical Work/ Equipment
Item Rate
365 days
ADDA OFFICE, DURGAPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹16,633
Yes
25 Feb 2021
12 Jan 2021
22 Jan 2021
12 Jan 2021
19 Jan 2021
12 Jan 2021
Amount
Supply of Hot dip Galvanized Swaged type Steel Tubular pole of 7.0 mtr long with inbuilt junction box including cut-out, terminal etc. for cable termination, base plate, pole cap & 1.5 mtr long swan neck as per specification IS : 410 SP 3 at work site of make BPP/Utkarsh Tubes and Pipes Ltd./Skipper Steel Ltd./Subham Pole
Erection of Single steel tubular pole in C.C foundation of size 600 mm x 600 x 1500 mm including muffing (cylindrical shape) of size 450 mm x 450 mm above ground level with stone chips including cement plastering & neat finishing with supply of materials & labour
Supply of XLPE armoured cable of 1.1 KV grade to the work site of size 16 mm2 x 4 core of make Polycab/Finolex/KEI
a) Laying of above cable after cutting the trench in all sorts of soil of size 460 mm x 760 mm average depth, with sand & brick protection (08 Nos. brick per meter, width wise) including back filling of shifted soil to restore the surface in original conditions.
b) Laying of above cable through Pipe/Pole etc.
Supply & laying of 50 mm dia, GI pipe (ISI - Medium) for protection of cable, road/drain crossing etc.
Supply & drawing of 1.5 sq.mm PVC single core multistrand copper wire from pole box to fittings through the pole & connection, testing complete of make Polycab / Finolex / KEI.
Finishing of PVC cable end with crimping method including supply & fixing of solderless socket, anti corrosive paste & jointing materials. 4C x 16 sq. mm.
Supply, installation, commissioning & testing of outdoor type feeder pillar box made of 2 mm CRCA sheet duly rust inhibited and stove enamel painting, complete with rubber gasket, hinged door at least 800 x 450 x 200 mm in size projected top cover, suitable ventilation and MS iron frame work with adequate space for provision of WBSEDCL meter. The panel consisting with 63 A TPN incoming, Astronomical time switch, toggle switch, contractor of L&T make for automatic operation of street light system.
a) Earthing with 50 mm dia GI pipe 3.64 mm thick X 3.04 Mtrs long and 1 x 4 SWG GI (Hot Dip) wire (4 Mtrs long), 13 mm x 80 mm long GI nuts bolts with double washer including (Tata-Medium GI pipe) making digging of soil etc. complete.
b) Treatment of soil by using salt and charcoal or coke.
Supply, fixing, connection & testing of outdoor type Street light fittings of IP66, IK05 LED Integral type streetlight luminaire with system lumen > 11500 Max system wattage 90 W with pressure die cast aluminium housing, Luminaire should be operable with auto adjustable 140V-270V supply voltage with same driver and with 3 KVA Surge protection, LM 80 For LED Source & LM79 for Luminaire is mandatory, Confirming the lighting level as per B1 category road of IS 1944 with spacing [Make: Philips (Cat no. BRP 409 LED 115 CW SLC FG PSU GR V2 SPD)/ Approved equivalent from Crompton/Wipro/Bajaj make]
Excavation of soil for installation of Earth Electrode and filling and ramming. For soft soil.
Excavation of soil for installation of Earth Electrode and filling and ramming. For morrum soil.
Extra for treatment of soil by using salt & charcoal or coke for electrode.
Connecting the equipment to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor/through pipe with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid GI wire. a) 4 SWG.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 16 sq. mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying & fixing solderless socket (Dowels make), tapes, anticorrosive paste and jointing materials: 4C x 16 sq. mm cable.
Supply at the work site of 1100 volt grade 1.5 sq. mm FR PVC insulated single core unsheathed multistrand copper cable conforming to IS: 694:1990. (Ph., N & E) from pole box to light fitting as per direction of EIC. Finolex/KEI/ Polycab/ Mescab.
Drawal of 1100 volt grade 1.5 sq. mm FR PVC insulated single core stranded copper wire conforming to IS: 694:1990 (Ph., N & E) from pole box to light fittings as per direction of EIC.
Painting of Steel Tubular Pole of lengths and no. of coats of paint,as given below with ready mixed paint/primer of approved make,and brand incl. preparation of surface by sand paper/emerypaper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long pole , 1st coat of aluminium paint over 1 coat of RO priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint,Upto 9.0 mtr. long pole , 2nd coat of aluminium paint over 1st coat. as given below with ready mixed paint/primer of approved make,and brand incl. preparation of surface by sand paper/emerypaper, cleaning etc. for receiving fresh coat of paint , Upto 9.0 mtr. long pole, 2nd coat of aluminium paint over 1st coat.
M/S JOYA ELECTRICALS
MONISH ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .