Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.7 L+₹3.2 L (7.97%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹43.3 L+₹3.7 L (9.43%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹43.4 L+₹3.9 L (9.74%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹43.5 L+₹4.0 L (10.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Jun 2023, 6:00 pmClosed
GE BENGDUBI
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR REPLACEMENT MAINTENANCE OF OLD UNSERVICEABLE INTERNAL WIRING SUB MAIN WIRING DBS FITTINGS ETC FOR OUTSIDE POCKET UNIT AND OLD UNSERVICEABLE XLPE CABLES PANELS MCCB EARTHING ETC FOR VARIOUS UNITS INCLUDING NEARBY MISC UNIT AREA UNDER AGE
2023_MES_601241_1
8457/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of D and above category b(i)
7 documents required · 7 mandatory
₹500
GE BENGDUBI
₹90,000
Yes
30 Jun 2023
5 Jun 2023
26 Jun 2023
5 Jun 2023
24 Jun 2023
19 Jun 2023
6 Jun 2023 - 10 Jun 2023
Amount
Dismantling of ACSR or AAC condutor from LT service feeder or distribution line complete all as specified and directed.
Taking out old/Unsv damaged existing steel/concrete poles of any size/length from existing position including necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed.
Dismantling insulators any type any sizes complete all as specified and directed.
Supply,erecting and fixing in proper position steel tabular electric pole swaged type 410 SP-31 (9 meter long) complete with CI base plate, final taper plug bolts nuts screw and pole cap and including two coat of aluminium paint over a coat of red oxide primer including preparing the surface complete all as specified and directed.
S&F in replacement digital Ammeter 3 phase LED display class 1 in replacement for measuring alternating current of range : 0 - 200 A flush type all as specified and directed.
S&F in replacement digital Voltmeter in replacement for measuring alternating current voltage of range : Range 0-500 V flush type 96x96MM size all as specified and directed.
S&F in replacement LED indicator - R/Y/B/G 240 V AC complete all as specified and directed.
Repairs to LT panel out door/indoor type including taking out old damaged / unserviceable door hinges and welding new hinges of size as per existing and providing one locking arrangement complete all as specified and directed.
M&L for preparation for old rusted steel surface of feeder pillar box/LT panel of any size ,applying one coat of synthetic enamel paint as per the existing pattern above the PCC and black paint on legs of feeder pillar/LT panel and cutting vegetation growth all around and on the feeder pillar box/panel board upto 1 mtr radius complete all as specified and directed.
M&L for earthing complete of advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgrated (Zinic & alloy coated) Zinic coated (80-100) microns with pure (99.9%) & alloy coating (200-250) microns earthing system confirming IS-3034 the outer and inner pipe should be 76.2mm & 41.9mm dia 2 mtr length zinic coated with additional special alloy coating 300mm on the topside for additional protection of the terminal the annular space between the pipes being filledup with compact fill(CF) (Crystalline conductive compound) the compact fill (CF) mixture which is machine pressed in the pipes should not disintgrate or collapse when outer pipe corrods, the inner pipe should be extended with terminals for connectivity. The job includes digging the pits and refilling the same by electrode/conductolite back fill compound (Ground enhancer)the BFC should dbe eco friendly it should not contain environmentally hazard materials having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP earth pitcover for protection and safe guard of terminals. In area where soil condition is bad good earth is to be arranged to fill the excavated pits by mixing the same with BFC 4 bags (as per soil condition) extra perpit/unit. As earth electrode is the main component of the earthing system which is indirect contact with the ground and thus provides ameans of releasing or collecting earth leakage current. The materials should have a good electrical conductivity & anti corrosion properrty in wide range of soil condition complete and testing on completion including dismantlingh unserviceable earthing complete all as specified and directed. (Make ASHLOK/JMV/True power or equivalent make as listed in list of make)
S&F in repairs MCCB 100 Amps 4 pole, 415 V, breaking capacity 16 KA,Ics=100% ICU,O/L & S/C protection including spreader terminals & connected accessories complete all as specified and directed. (Make:- Legrand / ABB / L&T/Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs MCCB 160 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25 KA, Ics=100 % ICU,O/L & S/C protection including spreader terminals & connected accessories complete as specified and as directed. (Make:- Legrand / ABB / L&T /Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs MCCB 200 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25KA,Ics=100 % ICU,O/L & S/C protection including spreader terminals & connected accessories complete as specified & directed. (Make:- Legrand / ABB / L&T /Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 25 KA, 100 % ICU,O/L & S/C protection including spreader terminals & connected accessories complete as specified & directed. (Make:- Legrand / ABB /L&T/Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs MCCB 320 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, Ics=100% ICU,O/L & S/C protection including spreader terminals & connected accessories complete as specified & directed. (Make:- Legrand / ABB / L&T/Scneider /C&S or equivalent make as listed in list of make)
S&F in repairs MCCB 400 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100% ICU,O/L & S/C protection including spreader terminals & connected accessories complete as specified & directed. (Make:- Legrand / ABB / L&T /Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs MCB 63 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 10 KA, 100% ICU including spreader terminals & connected accessories complete as specified & directed. (Make:- Legrand / ABB / L&T /Scneider/C&S or equivalent make as listed in list of make)
S&F in repairs on load changeover with handle in enclosure 100 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. (Make :-Legrand/L&T / ABB /Havells /C&S or equivalent make as listed in list of make)
S&F in repairs on load changeover with handle in enclosure 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. (Make :-Legrand/L&T / ABB /Havells /C&S or equivalent make as listed in list of make)
S&F in repairs On load changeover with handle 200 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. (Make :-Legrand/L&T / ABB /Havells /C&S or equivalent make as listed in list of make)
S&F in repairs On load changeover with handle 400 Amps, 4 Pole, 415 V, AC, 50 Hz complete all as specified & directed. (Make :-Legrand/L&T / ABB /Havells /C&S or equivalent make as listed in list of make)
Supply and fixing in repair 3 phase and neutral, 415 volts outdoor type Bus bar chamber 100 Amps, TPN, 4 way, 415 V, AC, 50 Hz, Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032) and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable. Suitable openable doors shall be provided of all operational busbar shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding complete for 3 phase 50 Hz electric supply complete all as specified & directed.
All all as per items No 24 here-in-before but 200 Amps, TPN, 4 way 415 Volt, AC, 50 Hz complete all as specified and directed.
Ditto all as per items No 24 here-in-before but 400 Amps, TPN, 4way, 415 V, AC, 50 Hz complete all as specified & directed.
M&L for cement concrete 1:3:6 type C-2(Using 40mm graded stone aggregate ) as lean concrete in foundation of poles, filling and mass concrete , stay assembly, etc, including formwork( as/if required) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1(Using 20mm graded stone aggregate ) as in coping of poles, including formwork( as/if required) complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Excavation in trenches , Exc 1.5m wide and n exc 3.0m in depth for foundation etc or for shafts,wells cesspits, manholes pier holes, laying of cable laying in pipes in exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
M&L clean dry sand in trenches/ ducts for cushioning to cable 8cm below the cable and 15cm above the cable complete all as specified and directed.
Supply & Laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
Relaying of old serviceable brick as in cable protection all as specified and directed.
Taking out old unserviceable under ground cable of any size, any position forn trenches, floors and wall and serviceable cable reuse all as specified and directed. (Earth work,segregating cable cover/brick, sand measured separately)
Relaying of serviceable cable from item No 36 after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 6 Sqmm 2 core to 16 Sqmm 2core complete all as specified and directed. Note : Straight through joint shall be measured and paid separately.
Relaying of serviceable cable from item No 36 after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 16 Sqmm 4 core to 70 Sqmm 3.5core complete all as specified and directed.Note : Straight through joint shall be measured and paid separately.
Relaying of serviceable cable from Item No 36 after detecting the fault and making straight through jointing kit of LT 440 volt under ground system of LT feeder/location of size 95 Sqmm 3.5 core to 200 sqmm 3.5 core complete all as specified and directed.Note : Straight through joint shall be measured and paid separately.
Supply and laying insulated, armoured, heavy duty electric cables with aluminium conductor 1100 volts, cross sectional area 6 sqmm 2 core laid in trenches/ through pipes/ducts or on pole/wall/floor jointing to OH conductor, LT panels, main switch with cables size aluminium lugs and testing complete all as specified and directed. (Note : excavation and RFR shall be measured and paid separately under respective items of Sch 'A') (Make : Polycab/Havells/KEI or equivalent make as listed in list of make)
Ditto all as per items No 40 here-in-before but 10 Sqmm 2 Core
Ditto all as per items No 40 here-in-before but 16 Sqmm 2 Core
Ditto all as per items No 40 here-in-before but 16 Sqmm 4 core
Ditto all as per items No 40 here-in-before but 25 Sqmm 3.5 core
Ditto all as per items No 40 here-in-before but 35 Sqmm 3.5 Core
Ditto all as per items No 40 here-in-before but 50 Sqmm 3.5 core
Ditto all as per items No 40 here-in-before but 70 Sqmm 3.5 core
Ditto all as per items No 40 here-in-before but 95 Sqmm 3.5 core
Ditto all as per items No 40 here-in-before but 120 Sqmm 3.5 core
Ditto all as per items No 40 here-in-before but 150 Sqmm 3.5 core
Material and labour for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting /removal of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes complete all as specified and directed.
Cutting and trimming of tree branches of any grith all around the LT over head lines upto 2 mtr from all around the over head lines complete and removing the cut branches from the site to a distances not exc 50 mtr complete all as specified and directed.
M&L for MS steel work (structure) as in cross arms breacing of MS channel or angle sections of required size and shape including clamps, D clamps, eye hooks, back plate with bolts, nuts and washers, drilling holes for bolts, insulator etc and welding to make rail to rest the cables in the existing ducts including priming coat and two coat of aluminum paint complete all as specified & directed.
Supply and fixing LT line polyproplene composite phase separators 2 line (bolted Type) at suitable spans conforming to IS 1445 complete all as specified and directed.
Supply and fixing LT line polyproplene composite phase separators 3 line (bolted Type) at suitable spans conforming to IS 1445 complete all as specified and directed.
M&L for painting of LT Steel tubular pole (9/11 mtr long) any type or size externally above foundation including all MS work with one coats of aluminium paint after scrapping / clearing well the existing surface all as directed and as specefied. (The above work includes painting of 3 Nos black & 02 nos yellow bands width 30 Cm by fluorescent paint in alternate layers upto 1.5 mtr height above foundation / plinthblock)
M & L for painting of 9 m PCC pole with cement wash two coat by using the cement and two coat of aluminium paint over cross arms, clamp of any length and shape for LT overhead line including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three black & two yellow bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
M&L for repairs to main electrical panel at sub stations by tightning the all loose connections of the cable ends & replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portin of cable ends inside the panel by taping with good quality of insulation tape, clean the dust by air blower complete all as specified and directed.
M&L for stringing, ACSR conductor of required size for O/H lines, on LT poles, including binding wire, including taking down old ACSR Conductor complete all as specified & directed.
Restringing of each OH conductor with to permissible sag rebinding to insulators with new wire where cut point jumpers to be higher size of the OH conductor all as per specified and directed.
Horizontal boring using ultra sound technique/any other suitable mechanical means at approx 1 metre below the road, pavement, hardstanding etc without damaging the existing surfaces getting out & disposal of soil to a distance not exceeding 50 metre from the site of work complete all as specified and directed.
S&F in repair/replacement of energy saving, environmental friendly, long life, pressure die-cast aluminium housing with IP66 protection flood light with high power LEDs as light source connecting and testing LED flood lights of 200 watts capacity fixed on high mast/ street light pole complete all as specified and directed. (Make:- Havells/Crompton/C&S or equivalent make as listed in list of make)
All as per item No. 65.00 here-in-before but of 120 W capacity LED Flood light
All as per item No. 65.00 here-in-before but of 50/60 W capacity LED Flood light
S&F in repair GI pipe 50 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound condition complete all as specified and directed.
S&F junction box made of thermoplastic of size 205mm x 255mm x 112mm consisting of 4 Nos terminal on porceline support inside enclosure with MCB SP 6 Amps and using 40 x 6mm size MS clamps of required shape & size with bolts, nuts & washers and making connection by providing suitable size of lugs / binding and testing directed complete all as specified and directed. (Make : Hensel or equivalent make as listed in list of make)
M&L for load distribution of LT panels/feeder pillar box and building panel upto transformer phase balance, including insulation tap lugs etc if required for load distribution complete all as specifed and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as specified and directed.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Part I with using stay rod of 20mm dia and insulator etc. complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid seperately under relevant item.
M&L for 3 core cable 1.5 sqmm FRLSH PVC insulated copper conductor weather proof in existing surface/ recessed/on pole complete all as specified and directed.
M&L for PVC conduit pipe medium grade 20mm dia (ISI Marked) including necessary clamps, nuts, bolts etc. as required complete all as specified and directed.
Supply, jointing and testing straight through cable jointing kit (Heat shrinkable type) for 1100 volt grade cable complete with and including jointing materials and including accessories suitable for 2 core XLPE armoured aluminium conductor cable of size 6 sqmm 2 core to 16 sqmm 2 core and including provision of aluminium thimbles, complete all as specified and as directed. (Make: Denson / M Seal / Reychem or equivalent make as listed in list of make)
Supply, jointing and testing straight through cable jointing kit (Heat shrinkable type) for 1100 volt grade cable complete with and including jointing materials and including accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16sqmm 04 core and including provision of aluminium thimbles complete all as specified and directed. (Make: Denson / M Seal / Reychem or equivalent make as listed in list of make)
All as per items No 76 here-in-before but 25sqmm to 50 Sqmm 3.5 Core
All as per items No 76 here-in-before but 70sqmm to 150 Sqmm 3.5 Core
All as per items No 76 here-in-before but 185sqmm to 250 Sqmm 3.5 Core
S&F in repair danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for 25x20 cm size complete all as specified and directed.
S&F in repair earth continuity conductor GI strip 25x4mm size complete all as specified and directed.
S&F in repair earth continuity conductor GI strip 32x6mm size complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site (Note : To be measured only when found serviceable in all respects complete for reuse)
M & L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit piping in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface for the following. : (make :havells/polycab/finolex/KEI or equivalent make as listed in list of make)
One light point or one fan point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
M & L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent. (make :havells/polycab/finolex /KEI or equivalent make as listed in list of make)
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc for the following: - (make :havells/polycab/finolex/KEI or equivalent make as listed in list of make)
One light point controlled by 2-way switch.
One light point or one fan point or bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
M & L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent. (make :havells/polycab/finolex/KEI for cable)
M&L for concealed flame-proof point wiring FRLSH PVC insulated unsheathed single core multi-standard copper conductor cable 1100 volt gade of 1.5sqmm drawn through and including (medium grade) stove enamelled steel conduit in concealed of FRLS PVC insulted unshelathed single core multi standard copper conductor cable for earth continuity wire, connected to earth dolly and to be terminated in control Gear box/Flame proof switch wih and including flame proof junction box as per requirement including testing on completion compete including cutting chases for concealed conduct pinning in making good to facing and pointing in using cement mortar and making good disturbed surfaces complete all as specified and directed.
All as per item No 89 here-in-before but for one 15 amps 3 pin switch socket outlet, independent with FR-LSH PVC insulated unsheathed mltistandard copper conductor cable grade of 2.5 sqmm size alongwith one earth continuity conductor with FR-LSH PVC insulated unsheathed multistranded copper conductor cable grade of 2.5 sqmm size complete all as specified and directed.
Supply and fixing switch flame proof rotory type with termination box in LM6, 16A single pole 250 V complete all as specified and directed.
Supply and fixing flame proof switch socket & plug combined in LM6 cable termination box in LM 6, 16 A 250 V,2p+ Earth complete all as secified and directed.
S & F LED fitting 1x16/20 watts flame proof type FLP-WP made of aluminium alloy LM6, with all accessories LED lamp rod, pre wired and including connecting up copper conductor cable with suitabe size complete all as specified and directed.
S & F in replacement Switch piano, flush button, 5/6 Amps, single pole, two way, 230 Volts complete all as specified and directed.
S & F in replacement Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
Fixing only Switch piano any type complete all as specified and directed.
S & F in replacement Socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
Fixing only Socket outlet 5 Amp any type complete all as specified and directed.
S & F in replacement Switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
Fixing only Switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
Supply and fixing in replacement switch socket combination multipurpose 3 pin 15 amp flush type all as specified and as directed. (Make:Anchor/Plaza/ Kinjal or equivalent make as listed in list of make) .
Fixing only Switch socket combination 5A/ 16A, 5 in 1flush type complete all as specified and directed.
S & F in replacement Bell push, flush type, 5 amp complete all as specified and directed.
Fixing only Bell push complete all as specified and directed.
S & F in replacement Bell , AC, 230 Volts, single pole complete all as specified and directed.
S & F in replacement Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
Fixing only Ceiling rose any type complete all as specified and directed.
S & F in replacement stepped socket type electronic fan regulator flush type (2-Module) complete all as specified and directed.
S & F in replacement stepped switch type electronic fan regulator flush type complete all as specified and directed.
S & F in replacement LED Tube Light Batten luminaries, aluminium body with high performance LED with driver 1 x 20W (4 Feet long, Cool day/Warm white) complete all as specified and directed . Make :HPL/philips/Havells/Crompton.
S & F in replacement Decorative CITY 1 wall light fixture made up of Polycarbonate suitable for 9 W LED lamp (B22) includin 10W LED Bulb etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexiblecopper conductor cable with suitable size complete all as specified and directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make)
S & F in replacement light fitting,1x10W LED bulk head luminaries IP65, complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V,50HZ complete all as specified and directed. . (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make)
S & F in replacement Building security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including GI bracket medium grade bent to shape all as specified and as directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make)
S&F in replacement Lamp holder , PVC / Polycarbonate type with back plate suitable for B22 lamp including LED Bulb 9W complete all as specified and directed.
S&F in replacement 12W LED Round/Square surface mounted downlighter including suitable driver & all accessories to fixed on Ceiling/Wall complete all as specified and directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make) .
S&F in replacement 12W LED Round/Square recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement complete all as specified and directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make)
S&F in replacement 36W LED Square Type 2' x2' recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make) .
S&F in replacement 36W LED Square Type 2' x2' surface mounted downlighter including suitable driver complete all as specified and directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make) .
Fixing only serviceable light fitting any type complete all as specified and directed.
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site complete all as specified and directed.
S & F in replacement sheet metal enclosure for MCB, DBs, Vertical type, double door, 4 Way, phosphatised, Powder coated , Triple Pole and Neutral (TPN), fixed flush to wall , IP 30 and IK 08 Protection Grade, including adjustable type MCCB as incoming of capacity 100Amp,4 pole with breaking capacity 25kA, 4 way, Double door 415 Volts complete all as specified and directed. (Make:LEGRAND/ABB/schneider or equivalent make as listed in list of make)
S & F in replacement Sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/ABB/schneider or equivalent make as listed in list of make)
S & F in replacement Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/ABB/schneider or equivalent make as listed in list of make)
S & F in replacement Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/ABB./schneider or equivalent make as listed in list of make)
S & F in replacement Sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with common bus bar at incomming end complete all as specified and directed. (Make:Legrand/ABB/.schneider or equivalent make as listed in list of make)
S & F in replacement Sheet metal enclosure for MCB DB Single door single pole & Neutral 2 way without busbar complete all as specified and directed. (Make:Legrand/havells/L&T/ABB or equivalent make as listed in list of make) .
Refixing of MCB DB any type complete all as specified and directed.
S & F in replacement MCB Four pole, 415 volts, 40-63 Amps, breaking capacity 10KA complete all as specified and directed. (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make)
S & F in replacement MCB 'C' series Double pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make)
S & F in replacement MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make)
Refixing of MCBs any size any type complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation all as specified and directed.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as directed. (Make :Polycab/Finolex/KEI (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make). Note:For concealed sub-main wiring cutting chases will be included in same rate.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as directed. (Make :Polycab/Finolex/KEI (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make). Note:For concealed sub-main wiring cutting chases will be included in same rate)
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit complete all as directed. (Make :Polycab/Finolex/KEI (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make). Note:For concealed sub-main wiring cutting chases will be included in same rate)
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 1.5 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 1.5 sqmm as earth continuity conductor drawn through PVC conduit complete all as directed. (Make :Polycab/Finolex/KEI (Make:Legrand/ABB/C&S/schneider or equivalent make as listed in list of make). (Note:For concealed sub-main wiring cutting chases will be included in same rate)
S & F in replacement Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F in replacement Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F in replacement Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F in replacement Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F in replacement Modular Regulator Step Type 120 watt, 2 module complete all as specified and directed.
S & F in replacement Modular Blank plate, 1 module complete all as specified and directed.
S & F in replacement Modular type White cover plate with frame 2 module complete all as specified and directed.
S & F in replacement Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F in replacement Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F in replacement Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F in replacement Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F in replacement modular metal flush box 1/2 module all as specified and as directed.
S & F in replacement modular metal flush box 3 module all as specified and as directed.
S & F in replacement modular metal flush box 4 module all as specified and as directed.
S & F in replacement modular metal flush box 6 module all as specified and as directed.
S & F in replacement modular metal flush box 8 module all as specified and as directed.
S & F in replacement LED bedside light fitting 18/20W and in-built on-off switch as directed.
S & F in replacement surface and wall mounted LED batten luminaries, aluminium body 20W with integrated electronic driver (4 Feet long) complete all as specified and directed . (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make).
S & F in replacement surface and wall mounted LED batten luminaries, aluminium body 9/10W with integrated electronic driver (2 Feet long) complete all as specified and directed . (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make).. .
Supply and Fix in replacement LED down lighter with aluminium housing recess mounted round / squre type 15 watt complete all as specified and directed. (Make:philips/Havells/Crompton/HPL or equivalent make as listed in list of make).
Supply and Fix in replacement LED down lighter with aluminium housing surface mounted round / squre type 15 watt complete all as specified and directed. (Make: philips/Havells/Crompton or equivalent make as listed in list of make).
S&F in replacement 50W LED Flood Light including suitable driver, nut, botls, washer, bracket & clamps , IP-66 complete all as specified and directed. (Make: philips/Havells/Crompton or equivalent make as listed in list of make).
S & F in replacement LED post top light 25 Watt IP65 Efficacy ≥110LPW as suitable including all accessories complete all as specified and directed. (Make: philips/Havells/Crompton or equivalent make as listed in list of make).
S & F LED in replacement SPOT light with spike 15 watt cool day/Warm White any colour adjustable type complete all as specified and directed.
S & F in replacement surface and wall mounted LED batten luminaries, aluminium body 22W with integrated electronic driver (4 Feet long) complete all as specified and directed . (Make: philips/Havells/Crompton or equivalent make as listed in list of make).
S & F in replacement MS Box in concealed of any type and any size complete all as specified and directed.
S & F in replacement hylum sheet of size 300 x 250 x 3 mm all as specified and as directed
S & F in replacement hylum sheet of size 250 x 150 x 3 mm all as specified and as directed.
S & F in replacement hylum sheet of size 150 x 100 x 3 mm all as specified and as directed.
S & F in replacement PVC rectangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep complete all as specified and directed.
S & F in replacement PVC rectangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 175 x 100 x 50 mm deep complete all as specified and directed.
S & F in replacement flexible wire 2 core copper size 1.5 sqmm complete all as specified and directed.
S & F in replacement Single Pole and neutral enclosure with a two pin and earth plug and socket complete with MCB Amp complete all as specified and directed. (Make ABB/Legrand/scheinder or equivalent make as listed in list of make).
Materials and labour for earthing complete with galvanised earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.50 mtr below normal ground level connected to galvanised lead lead wire 4.0 mm dia by means of bolts, nuts and washers and check nuts of galvanised iron or steel GI earth strip protected by 40 mm medium grade galvanised iron pipe including of 20 mm dia medium grade GI water tubing sheet metal 4mm wire mash funnel, charcoal or coke and common salt in paint and testing on completion as shown on electrical plate No.5 ofm SSR Part-I. including taking out unserviceable one complete all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 42,451.00 (refer Tender Srl Page No 42). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
UNIVERSAL CONSTRUCTION
M/S POWER ENGINEERS
M/S KAR CONSTRUCTION
PRADIP KUMAR BOSE
NABIN CONSTRUCTION AND CO.
M/S R. K. INDUSTRIES
NAYAK BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .