DIRECTOR ICDS
DIRECTOR ICDS 3RD FLOOR INDIRA BHAWAN LUCKNOW
ROOM NO 615 OF INDIRA BHAWAN 6TH FLOOR LUCKNOW ESTABLISHED CONFERENCE HALL-INTERIOR WORK AND ELECTRICAL WORK
2025_DICDS_1098048_1
C1180/BVP/NAZARAT/25-26 DT 10.12.2025
Open Tender
Civil Works
Fixed-rate
35 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Director, Bal Vikas Seva Evam Pustahar
₹78,500
5 Jan 2026
10 Dec 2025
29 Dec 2025
10 Dec 2025
26 Dec 2025
10 Dec 2025
Laying and Jointing PVC Pipe. Heading
Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coating of grade 350 as per IS 277 and consisting of angle cleat 25x1.6mm with flanges of 22mm and 37mm at 1200mm c/c one flanged fix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia bolt to the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ c shall be fixed in direction perpendicular to GI channels with connecting clips made out of 2.64MM diax230mm long GI wire at every junction including fixing the gypsum board with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partition with help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixing to a flush finish of tappered end sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting.12.50mm thick tapered edge gypsum board.
Providing & Fixing of Armstrong Suspended Ceiling System with Armstrong H4988 BP4988S DUNE Bev. Teg. 600x600x15mm (Microlook) EDGE TILES WITH ARMSTRONG Silhouette Exposed GRID. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm ,and 600x1200x15mm suitable for Green Building application, with Recycled content of 66% GW.The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm. Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and a load carrying capacity of 10 Kgs/M2.The Tile & Grid system used together, all complete as per drawing, specification and direction as approved by the Architect/ Engineer -in-Charge
Providing and fixing of 8mm Thick Laminated Herringbone Wooden flooring Classification of Use 23/32 (Heavy Domestic/Domestic) with a Surface Abrasion Resistance of class AC3 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1212 mm X 137 mm having Uni fit locking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Make-FloorMaster/Armstrong/Haro. all complete as per drawing, specification and direction as approved by the Architect/ Engineer -in-Charge. Make-Action Tessa/Equivalent
Providing & Making & Fixing of Commercial Wall Panneling made with Aluminium Section of 2"x1" @ 2'CC frame work cladded with 12MM Ply complete with painted or polishe. as per the approved design all complete as per drawing, specification and direction as approved by Engineer -in-Charge.
Providing & fixing Toughned glass In Window with 12mm Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge.
Providing & Making & Fixing of Wall Panneling made with 1MM Laminate & 5.5MM MDF on Existing Surface complete with painted or polishe. as per the approved design all complete as per drawing, specification and direction as approved by Engineer -in-Charge.
Providing and supplying Acoustical Wall Paneling with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire -resistant fabric with an option of colours as per the choice of the Architect/ Person in-charge of size as desired design providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers and construction adhesives as per the instructions laid down by the manufacturer as per the approved design as approved by Engineer -in-Charge.
Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm or as required by the Architect/ approving engineer, made of a high density particle board substrate with a laminated facing as per the approved shade & finish and a PU balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. as per the approved design as approved by Engineer -in-Charge.
Providing & Making & Fixing of Wall Panneling made with Coloured Lacquered Glass on Existing Surface complete with Melamine Polishe. as per the approved design all complete as per drawing, specification and direction as approved by Engineer -in-Charge.
Providing & fixing of Flush Door Laminated both side complete with all fittings,Round mortis lock,door closer etc all complete as per drawing, specification and direction as approved by Engineer -in-Charge.
Providing & Fixing of Zebra Blinds of approved shade as per drawing & specification as approved by Engineer -in-Charge.
Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specification as approved by Engineer -in-Charge.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Supply & Fixing of windows made from multi chambered UPVC profiles of minimum 60/108 mm thickness of (Wintech make or equivalent) in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced with galzvanized steel profiles of designed thickness.Float glass of approved colour in 5mm Toughened Glass or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as approved by the Architect/ Engineer -in-Charge.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work.
Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire
Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable)
Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM
Supply & Fixing
of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
S&F of 160 Amp 4 pole MCCB (16 KA) Thermal Magnetic release
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Wireman for Dismentalling Old Electrical Circuit & Electrical Fittings & Fixtures
Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA
Supply and Fixing of recess mounting round 7 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.
Supply and Fixing of recess mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.
Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent
Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent
Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent
Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed, for computer networking complete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with 2nos RJ-45 Data outlet
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
TD.pdf
Tender Documents • 14.55 MB
BOQ_2022125.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .