| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹45.8 L+₹3.2 L (7.48%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹46.6 L+₹4.1 L (9.53%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹48.0 L+₹5.4 L (12.7%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹55.3 L+₹12.7 L (29.9%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹89,500
Closing Date
3 Nov 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-10
PROVN OF COMMERCIAL AND STANDBY POWER SUPPLY FOR ORTHO-I AND II WARDS, PROVN OF VOLTAGE STABILIZER ALONG WITH UNINTERRUPTED COMMERCIAL AND STANDBY POWER SUPPLY FOR CARDIOLOGY DEPT AND REPAIR/ REPLACEMENT OF UNSERVICEABLE STREET LIGHT/ FLOOD LIGHT ETC
2020_MES_381822_1
GE/BH-45/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D, Category b(ii)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹89,500
Yes
11 Jan 2021
1 Oct 2020
5 Nov 2020
1 Oct 2020
3 Nov 2020
21 Oct 2020
Amount
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded aluminium conductor 11000 Volt grade of size 3 Core, 95 Sqmm, earth system complete all as specified and directed.
S&F cable jointing kit for 11 KV earth grade cable for outdoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
S&F cable jointing kit for 11 KV earth grade cable for Indoor type termination, Hot shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE insulated, screened, PVC inner sheathed, armoured with galvanised steel strip or wire, electric power cable, heavy duty with stranded aluminium conductor 1100 Volt grade, laid in trenches / duct, passing through pipe / duct or fixed on pole, complete all as specified and directed of the following sizes:-
240 Sqmm 3.5 core
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 32 x 6 mm GI earth strip electrode welded and revetted to earth plate up to a distance of 7.5 metre long, GI earth strip encased in and including 40mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supply, installation, testing and commissioning 200 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @2.5 % by means of hand operated off load tap changing gear, 200 kVA capacity transformer, copper wound, step down, outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled, with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 % to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be double copper wound (Leve-2) as per IS-1180 (Part-I) 2014 with HT & LT box including the following standard fittings including necessary foundation with block masonry work complete all as specified and as directed with following specifications specified in Srl No 7.1 here-in-after:-
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning Diesel Engine driven generating set of 160 KVA capacity, 3 phase, 4 wire, 415 V, 1500 RPM, AC power supply, with power factor 0.8, coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features), modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design there by facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer including necessary earth work, PCC foundation with Block Masonry & Plastering work as required at site complete all as specified and as directed with following specifications specified in Srl No 8.01 to 8.06 here-in-after:-
(A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 160 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002. The Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan ( Blower type ) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters ( mounted) (xii) 12 v self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type ) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with the followings accessories:- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water (j) Safety control against low lubricating oil pressure (k) Over speed stop with double driven adopter
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation. Brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364. (ii) Type :- Self excited self regulated with automatic voltage regulator . (iii) Rating :- 160 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : - 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected . (vii) Enclosure :- Screen protected drip proof . (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H
(C) CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 160 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Fuel tank - One No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features:- (i) Level indicator. (ii) drain plug. (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP: - Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two Nos 24 plates 12 Volt, 180 AH connected to the system, fully charged including lead and battery terminal's complete . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.
(E) AMF PANEL : - Supply, fixing, testing & commissioning Auto main failure ( AMF) panel, 15 SWG, 160 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick totally enclosed dust, vermin and water proof, duly painted with powder coated (shade No. 7032 Siemens gray ) fully wired up and ready to connect load & control lines in comprising the followings:- (a) Under Voltage relay 415V AC for main - 01 No. (b) Under voltage relay 415 V AC for DG – 01 No. (c) AC Timer 230 Volt, 2 No. +2 NC - 01 No. (d) DC Timer 12/24 V - 01 No. (e) Engine Start relay 12/ 24 V - 01 No. (f) Control MCB SP 6 Amp. 230 V – 01 No. (g) Transformer 12 / 24 V – 01 No. (h) Rectifier suitable size – 01 No. (i) LED Indicating Light for Main & DG - 06 Nos. (j) LED Indicating Light for Main & Gen. ON – 02 Nos. (k) LED Indicating Light for battery Charger – 01 No.
Supply, erection and fixing new pre-stressed concrete pole in true vertical position, 11.0 metre long, cross sectional area 152 mm X 152 mm at top and 152 mm X 260 mm at bottom, class 9 complete all as specified and as directed. Note: Earth work & PCC for foundation shall be measured & paid separately under respective item of this Schedule.
S&F lightening arrestor, non-linear type, HT, 11 KV, having 10 KA discharge capacity, confirming to IS 3070 part I, including connecting complete all as specified and as directed.
S&F Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia, ball and socket type, white, brown or green, 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts with hardware fitting complete all as specified and as directed.
S&F pin type insulators, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut of 150 mm dia for 11000 grade volts complete all as specified and as directed.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over and including one coat of red oxide primer complete all as specified and as directed.
S&F Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 250 mm x 200 mm size complete all as specified and directed.
Supplying, installation, testing and commissioning 100 KVA Servo controlled voltage stabilizer in sheet steel ventilated natural oil cooled construction (complete with first filling of transformer oil) having construction is in such a manner that all the 3units of single phase line voltage stabilizers connected in star. The set shall cater for unbalanced load and unbalance supply provided the input voltage between any phase and neutral and output current in any phase are with in limits complete all as specified and directed with the following specifications:- I/P Voltage : 320V-480V 3 Phase unbalance I/P Frequency : 47-53 Hz O/P Voltage : 415V ± 1%, 3 Phase, 50 Hz O/P should be star connected as per is 9815 O/P Adjustment : ± 5% of rated O/P O/P Voltage accuracy : Better than + 1% Rating : 100 KVA at UPF Load : Unbalance Speed of Correction : 13V / Sec (ph-ph) Efficiency : Better than 96% Waveform distortion : Nil Effect of load : Nil Environment : Indoor tropical use Ambient : 0-50 deg. C. Material for windings : Copper The Servo controlled voltage stabilizer shall have following additional features:- Full solid state control circuit, No effect ON load Power factor, Auto/manual operation facility, Tripping indication : High/Low I/P voltage tripping with overload /short circuit tripping facility, By pass arrangement with changes over switch, Audio visual alarm circuit, Indicator for I/P/O/P Volt O/P Amp frequency meter Digital/Analog.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation/ fixing pole/ laying cable and pipe line etc or for man hole etc not exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated Soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and as directed. Note: For measurement & payment purpose, punned thickness of sand only shall be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm for cable covering complete all as specified and as directed.
S&F PCC cable route indicator, pedestal type, size 30cmx30cmx10 cm, made out of RCC with 10 mm dia rod circular, 60 cm above the ground level & 30 cm below ground level, with PCC (1:2:4) type B1 above GL, PCC ( 1:4:8) in foundation below ground level duly engraved letter HT/LT cable complete all as specified and as directed.
Supply, installation, testing and commissioning 160 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @2.5 %, by means of hand operated off load tap changing gear, 160 kVA capacity transformer, copper wound, step down, outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled, with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV), in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 % to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be double copper wound ( Level -02 ) as per IS : 1180 (Part -1) 2014 with HT, LT cable Box including comprising with the following standard fittings, PCC foundations with block masonry work and plastering complete all as specified and as directed with following specifications specified in Srl No 22.01 here-in-after:-
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed.
Supply, installation, testing and commissioning diesel Engine driven generating set, 100 KVA capacity, 3 phase, 4 wire, 415 V, 1500 RPM, AC power supply, with power factor 0.8, coupled directly to alternator mounted on a common base plate complete, with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer including necessary earth work, PCC foundation with Block Masonry & Plastering work as required at site complete all as specified and as directed with following specifications specified in Srl No 23.01 to 23.06 here-in-after:-
(A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 100 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002 the Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan (Blower type) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters (mounted) (xii) 12 V self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with followings accessories :- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water (j) Safety control against low lubricating oil pressure (k) Over speed stop with double driven adopter
(B) BRUSH LESS ALTERNATOR: - (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type :- Self excited self regulated with automatic voltage regulator. (iii) Rating :- 100 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed :- 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected drip proof. (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H
(C) CONTROL PANEL: - The control panel shall be with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it shall display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 100 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and as directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP:- Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two Nos, 24 plates 12 Volt, 180 AH, connected to the system, fully charged including lead and battery terminals complete . (d) Base plate :- Fabricated out of MS channels ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.
(o) DC Volt Meter 15/30 V - 01 No. (p) DC Amp Meter 0-15 A. - 01 No. (q) Trickle / Boost switch – 01 No. (r) Auto / Manual Switch - 01 No. along with AMF Digital controller SCADA compactable with inbuilt RS 485 Port and Communication cable of Make: Procom Model No ECON-A-322 HSN: 85030010 or equivalent Model of Make Deepsea/ Wood ward (s) Start & Stop Push Button - 02 Nos. (t) Frequency Meter – 01 No. (u) Power Contactor MNX 265 3 Pole 415V for DG. - 01 No. (v) Power Contactor MNX 265 3 Pole 415V for Main.- 01 No. (w) MCCB 400 A 35 KA 3 Pole - 02 Nos. (x) Control Relay - 01 Set. (y) Over Load Relay 2.5-4A. – 01 No. (z) Hooter 24 V DC - 01 No. (aa) On load change over Switch 630 A. for bye Pass Main Supply & DG – 02 Nos.
Supply, installation, testing and commissioning 11 KV , 630 Amps, outdoor type Compact switch gear Ring Main unit, Non-Extensible type, having 02 Nos. Load Break Switches and 01 No Vacuum circuit breaker, all Manual Operated modules with IP class as IP 54, for outer door separately , inside the RMU there shall be an additional cable door with IP3X and Mimic of IP2X and necessary PCC foundation work as per manufacturer's instructions, along with bottom cable entry and front cable termination complete all as specified and as directed with following Accessories & specification specified in Srl No 24.01 to 24.06 here-in-after:-
(A) 630A manual Load Break Switch module for making of fault current along with Earth Switch of full making capacity -2 Nos. Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28kV Impulse withstand voltage - 75kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable up to 3 core 300 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B) Set of 03nos. Ring Core Metering CTs 150-300/1A as per feeder load, 2.5VA, Class 1.0
(B) 630A manual VCB module for making & breaking of fault current along with Earth Switch of full making capacity -1 No Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28KV Impulse withstand voltage - 75kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Right angle non-touch proof Termination boots - 1 Set (R,Y,B)
Stored energy mech. for manual operation - 01 Nos Set of 03nos. Ring Core Protection CTs of ratio 40-80A/1A as per feeder load, 2.5VA, 10P10 - 01 Set Set of 03nos. Ring Core Metering CTs of ratio 40-80A/1A as per feeder load, 2.5VA, Class 1.0 - 01 Set Capacitive voltage indication fixed type VPIS 6-12 kV - 01 Nos
(C) Set of 03 Nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side.- 01 Set Space Heater (230VAC)- 01 Nos Low Voltage Box containing • Multifunction Meter for each module showing kVA, kVAR, kW, Hz etc in the same . • R-Y-B Phase Indication Set of Coupling bus bars along with suitable coupling kit.- 01 Nos Manometer- 01 Nos Operating handle- 01 Nos
Notes for item No 24.00: - (a) RMU Tank shall be IAC AFL 20kA/1s tested to ensure utmost operator safety .Test report (from an STL member Lab) shall be submitted along with drawings of the RMUs . In case the test report is not found suitable , the RMU shall stand liable to be rejected. (b) The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. (c) Additional items like Operating handle etc. shall be delivered with the RMU (d) RMU shall be completely manual with all SCADA contacts for monitoring of LBS/VCB (control not required) terminated on a designated Terminal Block for easy take off by the SCADA team for integration in future. Also, motorization of RMUs shall be possible at a later date, if required. Same contacts shall be clearly mapped in the Engineering drawings for approval with designated TB Nos. for easy identification and integration. (e) RMU tank shall be of 304 grade, Non-magnetic, Non-ferrite Stainless Steel. Inferior Grade of Steel shall not be acceptable. (f) RMU shall have site replaceable bushings for ease of trouble shooting at site and quick repair and restoration at site. (g) Earth switch shall be on line side and shall have making capacity.
Notes for item No 24.00 (Contd...): - (h) Contractor shall purchase RMU directly from OEM and necessary factory inspection shall be arranged before dispatch RMU from OEM premises. The testing officer shall be nominated by accepting officer after written confirmation received from contractor for RMU is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in OEM premises in presence of testing officer and contractor. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect shall be bear by contractor and inclusive in quoted rate. Nothing extra shall be admissible to contractor in this respect. (j) The Quoted rates for RMU shall be inclusive of making Platform as per OEM instructions, made with bricks and necessary PCC at Bottom and Top and plastering complete all as directed by Engr-in-Charge.
Supply, installing, testing and commissioning Outdoor type Feeder Pillar Box, floor mounted, suitable for 415 Volt, 3 phase, 4 wire, 50 Hz, AC supply system, having bus bar chamber with duly insulated Aluminium Bus bars of rating 500 Amps mounted on epoxy/ SMC type insulator and the minimum inside depth of panel is not less than 500mm of size 900mm x 1200mm. The panel shall be dust and vermin proof IP 54 class protection and made out of 3.15mm CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work, 90 cm height and grouted 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear) openable type for cable entry, with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable, IS 694 marked, of adequate size but not less than 1.5 Sqmm complete all as specified and as directed with the following incoming and outgoing feeders:- (a) Incoming :- (i) MCCB TPN, LT 415 Volts, 50 Hz, AC grade, 315 Amps rating and 35 KA : 01 No. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade, 160 Amps rating and 25 KA rupturing capacity - 02 Nos (ii) MCCB 4 pole, LT 415 volts, 50 Hz AC grade, 100 Amps rating and 25KA rupturing capacity - 03 Nos Note:- Earthwork and PCC foundation/Platform shall deemed to be included in quoted rates.
S&F in repairs LED Street Light fitting 25 Watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED Street Light fitting 45 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED Street Light fitting 90 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED Street Light fitting 120 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED FLOOD Light fitting 150 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED FLOOD Light fitting 240 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and as directed.
S&F in repairs LED FLOOD Light fitting 300 Watt, system efficiency not less than 100 lumen / Watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and as directed.
Supply, fixing and connecting in repairs weather proof twin core PVC Insulated, PVC sheathed cable, 650 V grade, copper multistranded conductor of size 2.5 Sqmm, as in service wire conductor for looping box, overhead line to street light fittings complete all as specified and as directed.
S&F in repairs Street light brackets made out of 40 mm bore GI light grade pipe, and 1200 mm long with a bend of 120 degree suitable for street light fittings with 2 sets of clamps of mild steel flat 30 mm x 6 mm suitable for RCC pole with nuts, bolts and washers complete all as specified and as directed.
S&F in repairs pole mounted junction box ( Street light boxes) sliding type (Door fits to base by means of sliding) for 3 phase, 4 wire lighting system, moulded in FRP including provision of 2 Nos MCB 16 Amps and bus bar insulator- 4 Nos, with nut & bolts with fixing arrangement, outdoor type of dimensions 340 x 160 x 123 mm ( H x W x D) complete all as specified and as directed.
S&F in repair LED decorative post Top lantern, 25 Watt fittings including all accessories and clamp including 4 metre height black painted galvanised pole, fixed in position including necessary PCC work and excavation as per manufacturer's instruction complete all as specified and as directed.
S&F in repair LED decorative post Top lantern, 35 Watt fittings including all accessories and clamp including 4 metre height black painted galvanised pole, fixed in position including necessary PCC work and excavation as per manufacturer's instruction complete all as specified and as directed.
Cutting/trimming of tree branches around street light fitting and flood light fitting along with trimming near and around HT four pole and two pole structure up to 5 metre distance at all sides and disposal of debris out side MOD land complete all as specified and as directed.
Shiv Enterprises
Leo Air and Power Solution pvt Ltd.
M/s Adhikari construction co.
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .