Supply, Installation, Testing and Commissioning of MGPS System in 150 Bedded CCHB at AIIMS Bhopal.
2026_IMSBP_923359_1
10/NIT/SE/E/ABEU/AIIMS/BPL/ 2026-27
Open Tender
Miscellaneous Works
Item Rate
90 days
AIIMS BHOPAL
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹9.8 L
Office of the Superintending Engineer, 4th Floor,
22 Aug 2026
22 Aug 2026
14 Sept 2026
22 Aug 2026
12 Sept 2026
7 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing and Commissioning of Medical Grade BSI Kite Mark & CE certified Copper Pipes/Tubes CDSCO: It shall meet with BS:EN: 13348:2016 standards, Solid Drawn, seamless, deoxidized, non-arsenical, half hard, tempered and degreased copper pipe confirming to the standard. All copper pipes should be medical grade degreased &delivered capped at both ends. The Copper pipes should be accompanied with Manufactured Test certificate for the physical properties & chemical composition. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified. Valid BSI Kite Mark and CE certificate must be submitted. Installation & testing: Installation of piping be carried out with utmost cleanliness. Only pipes, fittings and valves that have been degreased and fittings shall be used at site. Pipe fixing clamps shall be of nonferrous or non-deteriorating plastic suitable for the diameter of the pipe. Inert gas welding technique should be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing, in order to avoid carbon deposition inside the copper pipes. Only copper-to-copper joints are permitted on site except threaded or flanged joints may be made where pipelines are connected to items such as valves and control equipment. No flux used for joining Copper to Copper joints and on for joints made on site. Copper to copper joints be brazed using a 5% silver-copper phosphorous brazing alloy CP104. Suitable sleeves shall be provided wherever pipes cross through walls / slabs. All pipe clamps be non-reactive to copper. After erection, the pipes are to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice. All the pipes from manifold/plant upto the outlets painted with two coats of synthetic enamel paint and colour codification should be as per standards. | |||||
| 1.01 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 108 mm OD x 1.5mm thk | 60 | Mtr | - | - |
| 1.02 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 76 mm OD x 1.5mm thk | 100 | Mtr | 100 | ₹10,000 |
| 1.03 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 54 mm OD x 1.2mm thk | 350 | Mtr | 53 | ₹18,550 |
| 1.04 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 42 mm OD x 1.2mm thk | 600 | Mtr | 10 | ₹6,000 |
| 1.05 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 35 mm OD x 1.2mm thk | 1,240 | Mtr | 11 | ₹13,640 |
| 1.06 | Supply, Installation, Testing and Commissioning of Medical Grade Copper Pipe size 22 mm OD x 1mm thk | 1,835 | Mtr | 10 | ₹18,350 |
| 2Imported Medical Gas Isolation Valve with Pipe line assembly Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It should be blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa]. Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation. | |||||
| 2.01 | Imported ISO VALVE - SINGLE PORT/LOCKING 1-1/4" (35mm) | - | Nos | 10 | - |
| 2.02 | Imported ISO VALVE - SINGLE PORT/LOCKING 1-1/2" (42mm) | - | Nos | 22 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_970312.xls
BOQ • 0.40 MB
NIT10Final.pdf
Tender Documents • 8.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].