| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | ₹29.2 L Quoted ₹29.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹33.8 LRejected-Finance | ₹33.8 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹40.7 LRejected-Finance MAHALSA ROAD BINAGA KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | ₹40.7 L | L3 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | ABDUL RAHIM L2 | M/S KAMALKANTH NAIK L3 | NAGESH BEERAPPA NAIK WORKS CONTRACTOR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling /taking out existing Textile coverings including frames (if any) or hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing of dismantled material etc complete all as specified and directed. | 300 | Sqm | 40 ₹12,000 | 100 ₹30,000 | 30 ₹9,000 |
| 2.00 | Roughening/cleaning surfaces of roof/top surface of RCC slab etc with wire brush, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. | 300 | Sqm | 40 ₹12,000 | 50 ₹15,000 | 30 ₹9,000 |
| 3.00 | S&F for woven chicken wire mesh to exposed top surface of slab including necessary fixing materials, nails etc complete all as specified and directed. | 330 | Sqm | 130 ₹42,900 | 150 ₹49,500 | 75 ₹24,750 |
| 4.00 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in padding for levelling course of roof, rounded or chamfer edge sloping, coving all around at the junction of parapet and the roof slab etc concrete mixed with water proofing compound etc complete all as specified and directed. | 15 | Cum | 9,000 ₹1.4 L | 8,000 ₹1.2 L | 5,100 ₹76,500 |
| 5.00 | M&L for screed bed 15mm thick using WPC on concrete surfaces on roof top in CM 1:3 finished fair and smooth (without using extra cement) and mixed with water proofing compound @ 1% of weight of cement or as per manufacturer's instructions whichever is higher complete all as specified and directed. Note: (i) WPC shall be measured and paid separately. (ii) Water Ponding Test to be carried out after cement concrete/Plaster work for roof for min 72 Hrs | 300 | Sqm | 225 ₹67,500 | 350 ₹1.1 L | 150 ₹45,000 |
| 6.00 | Supply only water proofing compound complete all as specified and directed | 65 | Kg | 40 ₹2,600 | 40 ₹2,600 | 50 ₹3,250 |
| 7.00 | M&L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, at the rate of 0.40 ltr/Sqm, providing and laying 3 mm thick APP modified water proofing membrane weighting not less than 3.6 Kg/Sqm of approved make including minimum 10 cm side lap and 15cm end lap, laid and pasted with blue flame torching applications and finally finishing with solar reflective bituminous aluminium paint at the rate of 0.1Kg/Sqm complete all as specified and directed. | 300 | Sqm | 725 ₹2.2 L | 1,000 ₹3 L | 400 ₹1.2 L |
| 8.00 | M&L for applying two coats of Smart care damp proof of Asian Paints by roller/brush over a coat of primer with smart care damp proof 33 % dilution of Asian paints including preparation of existing surface by complete removal of existing treatment by means of chipping the surface to remove loose particles and mortar and clean the surface with wire brush and water wash etc including filling & coving with smart care repair mortar (wherever required), filling of crack filler with smart care crack filler of Asian Paints (wherever required) complete all as per manufacturer’s instructions, all as specified and as directed. | 300 | Sqm | 450 ₹1.4 L | 500 ₹1.5 L | 425 ₹1.3 L |
| 9.00 | S&F in repairs PVC Rotational moulded polythene water storage tanks triple layered (cylindrical vertical with 2000 ltrs capacity) incl lid with locking arrangements and all fittings & fixtures to connect with existing pipe line complete all as specified and directed. | 5 | Each | 20,000 ₹1 L | 30,000 ₹1.5 L | 10,100 ₹50,500 |
| 10.00 | Demolition of stone slabs and tile of any description laid bedded and pointed in any mortar in floors | 6 | 10 sqm | 1,000 ₹6,000 | 600 ₹3,600 | 340 ₹2,040 |
Updated dates
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
2 Apr 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
SPECIAL REPAIRS TO INDUSTRIAL CANTEEN AT NAD (KAR) AND PROVISION OF EARTHING POINTS and LIGHTNING CONDUCTORS IN BUILDING P-51, P-52, P-53 and P-54 OF NCS (KAR) AT KADAMBA VANAM, NAVAL BASE KARWAR.
2026_MES_754545_1
8478/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹68,000
Yes
22 May 2026
27 Feb 2026
4 Apr 2026
27 Feb 2026
2 Apr 2026
13 Mar 2026
27 Feb 2026 - 6 Mar 2026
Dismantling /taking out existing Textile coverings including frames (if any) or hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing of dismantled material etc complete all as specified and directed.
Roughening/cleaning surfaces of roof/top surface of RCC slab etc with wire brush, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
S&F for woven chicken wire mesh to exposed top surface of slab including necessary fixing materials, nails etc complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in padding for levelling course of roof, rounded or chamfer edge sloping, coving all around at the junction of parapet and the roof slab etc concrete mixed with water proofing compound etc complete all as specified and directed.
M&L for screed bed 15mm thick using WPC on concrete surfaces on roof top in CM 1:3 finished fair and smooth (without using extra cement) and mixed with water proofing compound @ 1% of weight of cement or as per manufacturer's instructions whichever is higher complete all as specified and directed. Note: (i) WPC shall be measured and paid separately. (ii) Water Ponding Test to be carried out after cement concrete/Plaster work for roof for min 72 Hrs
Supply only water proofing compound complete all as specified and directed
M&L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, at the rate of 0.40 ltr/Sqm, providing and laying 3 mm thick APP modified water proofing membrane weighting not less than 3.6 Kg/Sqm of approved make including minimum 10 cm side lap and 15cm end lap, laid and pasted with blue flame torching applications and finally finishing with solar reflective bituminous aluminium paint at the rate of 0.1Kg/Sqm complete all as specified and directed.
M&L for applying two coats of Smart care damp proof of Asian Paints by roller/brush over a coat of primer with smart care damp proof 33 % dilution of Asian paints including preparation of existing surface by complete removal of existing treatment by means of chipping the surface to remove loose particles and mortar and clean the surface with wire brush and water wash etc including filling & coving with smart care repair mortar (wherever required), filling of crack filler with smart care crack filler of Asian Paints (wherever required) complete all as per manufacturer’s instructions, all as specified and as directed.
S&F in repairs PVC Rotational moulded polythene water storage tanks triple layered (cylindrical vertical with 2000 ltrs capacity) incl lid with locking arrangements and all fittings & fixtures to connect with existing pipe line complete all as specified and directed.
Demolition of stone slabs and tile of any description laid bedded and pointed in any mortar in floors
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for 20mm Granite (of any type) work (table rubbed and polished ) in steps, jambs, pillars, window -cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including provision of screed bed 15mm thick in CM 1:4 complete all as specified.
Demolition of concrete in ground floor and pavings not exc 15 cm thickness (below or above GL) for cement concrete un-reinforced all as specified.
M&L for plain cement concrete 1:2:4 type B-2 using 40mm graded stone aggregates as in surface channels and drains all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete and as directed.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base for floors, hard standings etc all as specified and directed.
M&L for sand filling under floors including watering and consolidation for laying of paver block
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M35 Grade
M&L for providing cement concrete 1:2:4 type B1 20mm graded stone aggregate as in kerbs or mud stops
M&L for 75mm thick PCC 1:3:6 type-C2 using 20mm graded stone aggregate as in hard standing/ plinth protection and finishing the concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-1, 20mm graded stone aggregate as in floor complete all as specified and as directed.
M&L for non-skid joint free coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry over and including 15mm thick screed bed or bedding layer of cement mortar 1:4 for laying floor finishes complete all as specified and directed.
Ditto all as per item No 22 above but here as in skirting/dado etc set and jointed in neat cement slurry over 10mm thick backing coat in cement mortar 1:3 on fair faces of brickwork or concrete surfaces to receive wall finishes.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.06 Sqm but n.exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding.
M&L for Glazed ceramic tiles in vertical surface 300x200mm x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed including 10mm thick backing coat in CM 1:6 complete all as specified and directed.
Cutting opening in cement concrete walls (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.
Dismantling boarding, any description, fixed any position fixed with screws all as specified and directed
S&F in repair 18 mm/ 19 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination for wooden and fixed with screws to timber frame as in cupboards, shutters, shelves, pelmet etc. including fixing 18 mm wide 6 mm thick beading of 1st class HW (Teak) all around, complete all as specified and directed.
S&F in repairs continuous (Piano) hinges, mild steel bright finish or electrogalvanized width of flap 30 mm (when open) all as specified and directed.
Taking up or down steel tubing and connections for 20mm dia, including cleaning for refixing or removal to store etc complete
S&F steel water Tubing of 20mm dia, of 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc complete all as specified and directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of concrete surfaces and finished even and smooth without using extra cement and mixed with waterproofing compound @1% by weight of cement or as per manufacturer's instructions whichever is higher all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for rendering 10mm thick in CM 1:4 on fair faces of concrete/block surfaces and finished even and smooth without using extra cement all as specified and directed.
Taking down chowkats or frames and not exc.1.5 Sqm each with shutters(without taking of shutters from the frame)
Taking down chowkats or frames exc.1.5 Sqm but not exec 4 sqm each with shutters(without taking of shutters from the frame)
M&L for solid PVC door frame of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, as per specification and drawings.
S&F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain coloured PVC “C” channel having a PVC sheet strip of 20mm width stock inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour of PVC sheet fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement etc details as per specification and manufacturer's drawings.
Dismantling of wrought iron or mild steel work of any description all as directed.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directed.
M&L for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F in repairs Aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed.
M&L for 4mm thick sheet glass, ordinary quality and glazing with wooden beading not exc 0.5 Sqm in each pane all as specified and directed.
M&L for 2nd class hardwood scantlings timber fixed, or in chowkats, styles and rails of framed work, including dismantling wood work all as specified and directed.
M&L for flush shutters 40mm thick with ,solid core construction with particle board core and plywood face panels and both sided laminated with decorative face veneers with lipping/frame to match complete all as specified and directed.
M&L for mild steel flat iron holdfast for securing new wooden frame and similar articles conforming to FE 290 Gde-E-165 all as specified and directed
M&L for cement concrete block 1;2:4 type B-1 using 20mm graded stone aggregate in holdfast block including necessary formwork etc complete all as specified and directed.
S&F in repair Vitreous china wash down water closet pan ( pedestal pattern) white (Excluding fixing bolts , flushing cistern and flush pipe as fixed in repairs.
S&F in repair low level PVC flushing tank 10 litres capacity white with inlet ball valve float and handle including brackets.
S&F in repair vitreous China wash hand basin size 580 x 450mm white with brackets and flat back including cutting for pinning in ends of brackets incl taking out the existing unserviceable WHB complete all as directed .
S&F in repairs Vitreous China Half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement.
S&F 15mm pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed but fancy type.
M&L for waste fittings brass chromium plated for sinks ,WHB etc with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed, 32mm dia fixed
S&F PVC connections 15mm size with PTMT nuts of length 600mm
S&F in repair chromium plated fancy type Bib tap cast copper alloy with crutch or butterfly handle screwed and down screwed for iron pipe or for brass ferrule 15mm
S&F Chromium plated fancy type stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends iron pipe or for union 15mm bore or pipe.
S&F Stop valves, 20mm bore cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F tubular towel rail 20mm dia D type 600mm long between flanges brass chromium plated
S&F in repair CP Health faucet 900mm long with spring pipe as specified
M&L for unplasticized PVC pipe of pressure rating 10Kg f/cm² fixed complete on walls ceilings or on floor 15mm bore.
Ditto all as per item No.62 above, but 20mm bore
M&L for unplasticized PVC pipe of pressure rating 10Kg f/cm² fixed complete on walls ceilings or on floor 25mm bore.
Cutting chases for concealed water tubing and making good, cutting not exc 10cm girth as specified
S&F PVC (SWR) Gully trap 125/110mm setting and jointing with solvent cement
S&F PVC SWR pipe single socketed in any length with rubber ring joints, 110mm, fixed to walls.
S&F PVC SWR pipes single socketed in any length with rubber ring joints, 75mm laid in trenches or floors
S&F PVC SWR pipes single socketed in any length with rubber ring joints, 75mm on walls
S&F PVC SWR bends any radius 75mm
S&F PVC SWR bends any radius 75mm with access door.
S&F in repair 75mm PVC SWR floor trap plain with grating including jointing with solvent cement
Demolition of brick/stone masonry built in cement mortar including all quoins, pillars etc and removing the debris from the premises up to 500m all as specified and directed.
M&L for providing precast cement concrete block masonry with solid blocks exc 10cm width, type C-1, using 20mm graded stone aggregate and set in cement mortar 1:6 complete all as specified and directed.
Taking down rain water pipes (any size or pattern) including all fittings, heads, shoes, bends swan necks etc and removing to store.
Excavation in trenches n.exc 1.5m wide and n.exc. 1.5m in deep for pipe lines etc. in hard/dense soil complete all as specified.
Returning filing in including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soils.
Removing surplus excavated material (Soil) to a distance not exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
M&L for cement concrete 1:2:4 type B-1 for benching and rendered smooth with extra cement in CM 1:6 as specified.
S&F PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints, or jointed with solvent cement laid in trenches or in floors complete as specified and directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 to drain pipes 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested.
M&L for chipping the spelled and old concrete removing loosely adhering particles using wire brushes and make the structure for the application of Polymer modified mortar complete complying with standard specification including lead and lift for an average thickness of 30mm including disposal of debris outside MD land complete all as specified and directed. Note: 1. The cleaning of bar shall be in such a way that No rust shall be stick on it. 2. The removal of defective concrete shall be right round the bar, when going behind the necessary thickness
M&L for providing polymer modified mortar using cement mortar 1:3 mixed with metorbond cement modifier cum bonding agent @ 5 ltr per bag of cement or using SBR liquid 5% by weight of cement or as per manufactures instructions. The repair shall be carried out in already prepared surface (i.e chipping and reinforcement priming) where the application of Renderoc RG/Emcekrete fluid micro concreting is not possible. The prepared mortar shall be applied for an average thickness of 30 mm after and including application of Nitobond EP, in any case HS epoxy or equivalent bonding agent to the cement concrete mortar complete all as specified and as directed.
M&L for preparation of new plastered surface of walls and applying 2 coats of acrylic washable distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of any description & applying two coats of acrylic (antifungal) exterior grade paint of over one coat of primer on wall/roof including all safety and necessary scaffolding complete all as specified and directed
M&L for preparation of old wall surfaces of any description & applying one coat of acrylic (antifungal) exterior grade paint on wall/roof including necessary scaffolding complete all as specified and directed
M&L preparation of old plastered / decorated surfaces of walls and applying one coat of oil bound distemper on plastered/decorated wall surfaces complete all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying one coat of acrylic washable distemper all as specified and directed.
M&L for preparation of old painted wooden surface and applying a one coat of synthetic enamel paint all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc., removing materials to store for safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC conduit medium grade with all accessories in wall/ceiling/floor/roof etc., sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:
One light point or one fan point controlled by one switch with PVC single core unsheathed cables 1.5 sq.mm size.
One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size.
One 3 pin socket outlet, 5 amps, independent, with cables 1.5 sq.mm size.
One 3 pin socket outlet, 16 amps, independent, with cables 4 sq.mm size (for building lights).
One 3 pin socket outlet, 16 amps, independent, with cables 2.5 sq.mm size.
S&F in replacement switch piano 6 Amps one way flush type complete all as specified and directed.
S&F in replacement switch piano 16 Amps one way flush type complete all as specified and directed.
S&F in replacement socket outlet 2 in 1, 3 pin, 6 Amps flush type complete all as specified and directed.
S&F in replacement socket outlet 2 in 1, 3 pin, 5 and 16 Amps flush type complete all as specified and directed.
S&F in repairs switch socket combination 3 pin 16 Amps flush type multi-purpose matching with existing make ISI marked, all as specified and directed.
S&F in repairs for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as directed.
S&F in repairs ceiling rose surface bakelite 65 x 50 mm three terminal including PVC junction box complete all as specified and directed.
S&F in repairs wiring for circuit/sub main wiring along with earth wire with FRLS PVC insulated copper conductor single core cable in surface/recessed 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire as required including PVC conduit of dia 20mm complete all specified and directed. Note: 2 runs of cable, one run of earth cable and one run of conduit pipe shall be measure as one unit.
S&F in repairs amp rating 240V, 10KA ‘C’ curve miniature circuit breaker (MCB) SP 6 to 32 AMP and current carrying capacity in the MCB DB complete with connection, testing and commissioning.
S&F in repairs amp rating 240V, 10KA ‘C’ curve miniature circuit breaker (MCB) SPN 32 AMP and current carrying capacity in the MCB DB complete with connection, testing and commissioning.
S&F in repairs MCB DB SPN 8 way 240 Volt double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and DIN channel complete all as specified and directed.
S&F in repairs LED light fitting mirror type with high output diffuser 2 feet, 10 Watt, 220V AC decorative type with driver holder and LED lamp including connecting with three core flexible copper conductor cable complete.
S&F in repairs LED light fitting 1 x 22 Watt, 220V AC decorative box type with driver and LED tube including connecting with three core flexible copper conductor cable from ceiling rose complete.
S&F in repairs LED street light fitting for building security light 60 Watt 230V AC outdoor type with high pressure die cast aluminium housing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete.
M&L in repairs for earthing complete with galvanized steel earth electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to GI strip 25 x 4 mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as specified and directed. Note: The unit rate quoted shall be deemed to include for necessary excavation and earth work in any type of soil, PCC 1:3:6 chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC 1:2:4 type B1 cover slab 50 mm thick with 8 mm dia TMT bars @ 140 mm c/c both ways etc complete.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective parts, overhauling, cleaning, greasing, rewinding etc, and hanging up/fixing back in original position, connecting up and testing complete all as directed. Note: 1. The unit rate quoted shall be deemed to include for Minor items viz nuts, bolts split pin and rubber wheel, however Capacitor and bearing measured separately under respective items. 2. Rewinding of fan will be measured and paid for separately under respective items.
S&F in replacement ceiling fan regulator electronic step type 230 Volts single phase all as specified and directed.
S&F in replacement capacitor 2.5 mfd for ceiling fan/exhaust fan complete as specified and directed.
S&F in replacement bearing No. 6201 / 6202 / 6203 for ceiling fan/exhaust fan complete all as directed.
M&L for removing of burnt copper winding wire from ceiling fan of any make and size of 1200 mm sweep including cleaning of slots etc and rewinding with super enamelled copper winding wire as per existing size/ gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for removing of burnt copper winding wire from ceiling fan of any make and size of 300 mm sweep including cleaning of slots etc and rewinding with super enamelled copper winding wire as per existing size/ gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for Painting of ceiling fans of sweep 1200/1400 mm complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc
S&F in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200 mm sweep.
S&F in replacement blade suitable for 1200 mm sweep ceiling fan complete all as directed.
M&L for Air termination single aluminium copper rod, 12mm dia 300mm long all as specified and shown on drawing
M&L for aluminium strip 25x3.15 mm fixed over porcelain insulators of suitable saddles with fixing screws etc. for fixing the strip on roof and down conductors above ground as Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated Situation for loop earthing etc. as required all as per specified.
M&L for Galvanised iron strip 32 x 6mm buried in ground complete all as specified and directed
S&F GI pipe 50mm dia light grade with all fittings laid in trenches for cable protection for road crossing or pole/wall complete all as specified and directed
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos of 8mm dia 25mm long hex. head screw complete as specified.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_845126.xls
BOQ • 0.39 MB
Tender8478.pdf
Tender Documents • 0.79 MB
Download all tender documents and submit your bid