Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 1551 5 CHARANJEEV COLONY KAITHAL 1551 5 CHARANJEEV COLONY KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹21.6 L+₹2.5 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹21.8 L+₹2.7 L (14.2%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹23.8 L+₹4.7 L (24.6%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹24.3 L+₹5.2 L (27.4%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
20 Jun 2022, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR REPLACEMENT OF UNSERVICEABLE LOFT TANKS WATER STORAGE TANKS OF VARIOUS CAPACITY CLEANING AND ALLIED WORKS AT R S COLABA AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_527472_1
8201/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE(NW)Navy Nagar, Colaba
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹76,000
Yes
13 Jul 2022
30 May 2022
21 Jun 2022
30 May 2022
20 Jun 2022
13 Jun 2022
30 May 2022 - 20 Jun 2022
Amount
Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etc by Mechanical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land at a distance exc 5 Kms & n.exc 10 Kms and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge . Note :- Rates deemed to be included for pumping out water left below foot valve.
Sump capacity ranges from 1.00 ML to 1.5 ML
Sump capacity ranges from 0.25 LG to 0.5 LG
All as per item No 1.00 above but PVC over head tank at any location and of any capacity in highrise buildings & Low rise buildings.
OHT capacity ranges from 3000 ltrs to 5000 ltrs.
OHT capacity ranges from 2000 ltrs to 500 ltrs
OHT capacity ranges from 300 ltrs
All as per item No 1.00 above but RCC over head tank at any location and of any capacity in highrise buildings
(a) OHT capacity 10000 ltrs. Note: For ser No 01 to 03. Rate is deemed to be inclusive of marking painting with two coats of synthetic enamel paint black colour( UG sump) of size 50x100cm and 30x50cm(on RCC/PVC OHT) including writing with white synthetic enamel paint, letters not exceeding 80mm in width all as specified & directed :- (a) Capacity of sump/tanks in Gallons/Liters (b ) Due date of cleaning (c) Date of cleaning (d) SAVE WATER
Cleaning the vegetation including grass, bushes small trees and all vegetation growth complete including digging out the root of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and directed.
S &F in repairs FRP lid cover for PVC water storage tank including complete accessories for closing and locking arrangement suitable for 3000 - 5000 ltrs capacity all as directed and specified by Engineer-in-Charge.
All as per item No. 5.00 above but for PVC water tanks of 300-2000 ltrs capacity
Cleaning of loft tanks of capacity 270 to 275 ltrs in existing position by mechanised pressure,cleaned by using the remedical drinking water PVC tank cleaning solution and soaking out the water by wet vaccum pump and providing sticker showing the date of cleaning complete all as specified.
Supply and fix in repairs PVC (LLDPE) rectangular loft tank with lid of net capacity 275 litres with gross capacity of tank at least 5 percent in excess of minimum net capacity including 03 Nos adaptor with water for inlet / outlet overflow as per manufacturer instruction and over all dimension as 995-1200 mm length, 620-820mm width, 285-485mm height, 300mm internal dia of hand hole, minimum wall thickness 2.75mm, complete all specified and directed by Engineer-in-Charge. Note :- The weight of tank shall not be less than 11.0 Kg excluding lid.
Supply and fix in repairs PVC profile suitable for 270 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
Supply and fix in repairs Stop valves/stop cock, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle suitable for 15 mm bore dia ,screwed both ends for iron pipe or for unions and including necessary clamp & saddles all as specified and directed.
Supply and fix in repairs Bib taps, cast copper alloy with crutch or butterfly handle suitable for 15 mm dia bore , screwed down, screwed for iron pipe or for brass ferrule and including necessary clamp & saddles all as specified and directed.
Supply and fix in repairs brass float valve (ISI marked) high pressure with (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
Supply and fix in repairs brass float valve (ISI marked) high pressure with float (flat) and fly nut complete screwed for GI pipe 20 mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
S& F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, of size Fe 410-W(GdeE- 250) quality A or all as specified and directed by Engineer-in-Charge. (ii) Cost of making necessary holes in wall making good the disturb surfaces using cement and sand mortar for fixing iron section is deemed to be including in the rate quoted.
Disconnecting LT cables of various sizes from electric motor of different capacites and decoupling from the pumping sets. Removing and taking down carefully and transporting to authorised workshop for rewinding. Strip opening and dismanting complete rotor and stator assembly. Cutting and taking out old burnt copper winding from the stator assembly and cleaning the slots of stator with carbon tetra chloride solution. Material and labour for rewinding, complete stator assembly with and including super enamelled copper winding, wire of suitable gauge matching with existing. Applying the minimum two coats of insulation varnish and keeping the stator assembly in heating chamber to improve for insulation value. Assembling the motor, transporting to site of work, coupled with the pumping set, alignments properly, connecting the LT cables and commissioning complete of the following capacity of Electric motors :-
(a) 150 HP capacity
(b) 75 HP Capacity
(c) 40 HP Capacity
Supply and fix in repair/replacement three pole power contactor type range MNX 45 to 70, 3 phase, 415 Volt, 50 Hz. Make: L&T/Siemens/Hammer cuttler
Supply and fix in repair/replacement three pole power contactor type MNX 95,3 phase, 415V, 50 Hzs. Make: L&T/Siemens/Hammer cuttler
Supply and fix in repair/replacement three pole power contactor type MNX 110,3 phase, 415V, 50 Hzs. Make: L&T/Siemens/Hammer cuttler
Supply and fix in repair/replacement three pole power contactor type MNX 140,3 phase, 415V, 50 Hzs. Make: L&T/Siemens/Hammer cuttler
Material and labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 25 X 4mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected to existing earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead 7.5m length and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion. Note :- Cost of strip upto 7.5m long galvanised earth lead 25x4mm size & PCC earth pit to be casted on the PCC base of 75cmx75cmx40mm is deemed to be included in the quoted rate.
Supply and fix in replacement of Aluminium Strip of size 25x 3.15mm thick with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and directed
S&F PVC water storage Tank hoisting and fixing in position at any location removing existing distmantling RCC/PCC/PVC OHT and new foundation making as well as disconnecting all incoming & out going connection , provision of new tank fittings & connecting it at existing position up to 50 mm GI Pipe connection complete all as specified and directed.
(a) 5000 Ltr capacity
(b) 3000 Ltr capacity
(c) 2000 Ltr capacity
(d) 1000 Ltr Capacity
(e) 300 Ltrs Capacity
Material and labour for two coats synthetic enamal paint including surface preparation on old iron surfaces of any description over 10cm in width or girth,not otherwise described all as specified and directed.
Supply and fix in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples as specified and directed.
M/S V N ENTERPRISES
Shetty Construction Co
Anil Industrial Corporation
ASHOK ENTERPRISES
SHRI SAI ENTERPRISES
BOB ENTERPRISES
jkconstruction
vikas construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .