Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC Agency Sagar Presents Stood Lowest in the tendering process. | |
| 2 | L2₹21.4 L+₹11.8 L (123.1%)Rejected-Finance SURYANAGAR COLONY NEAR MAHILA COLLEGE SILIGURI 06 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L2 | Rejected-Finance Agency Stood L2 | |
| 3 | L3₹22.5 L+₹12.9 L (134.3%)Rejected-Finance AURABINDA PALLY RABINDRA SARANI SILIGURI 734006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | L3 | Rejected-Finance Agency Stood L3 | |
| 4 | L4₹23.3 L+₹13.7 L (142.9%)Rejected-Finance | L4 | Rejected-Finance Agency Stood L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents are not in order. |
Tender Value
Refer Docs
EMD Value
₹20,500
Closing Date
8 Feb 2019, 6:50 pmClosed
EXECUTIVE ENGG (P.W.D), D/DINAJPUR ELEC DIVN
OFFICE OF THE EXECUTIVE ENGINEER (P.W.D), DAKSHIN DINAJPUR ELECTRICAL DIVISION, BALURGHAT Dakshin Dinajpur - 733101
SITC of 62.5 KVA DG Set at Gangarampur Govt. Polytechnic College in the dist. Of Dakshin Dinajpur.
2019_WBPWD_207038_1
WBPWD/EE/DDED/e-NIQ-30/2018-19 (2nd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Gangarampur
Please refer tender documents
6 documents required · 6 mandatory
₹20,500
14 Dec 2020
11 Jan 2019
12 Feb 2019
11 Jan 2019
8 Feb 2019
11 Jan 2019
Amount
Supply & delivery at site on foundation including testing & commissioning of 62.5 KVA, 415V, 50Hz, 3Ø silent DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engin & Acoustic Enclosure including transportation, loading and unloading of the DG set, having following specifications :- [ Make: JAKSON / KOEL GREEN / GREAVES POWER / MAHINDRA / ASHOK LEYLAND / EICHER ]
ENGINE
Make : CUMMINS / KIRLOSKAR / GREAVES POWER / MAHINDRA & MAHINDRA LTD. / ASHOK LEYLAND / EICHER(VECV)
Engine Type : 4 or 6 Stroke Diesel Engine
Rated Output : 80 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 4
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 90 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 11.53 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 15.31 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make : STAMFORD / KEC / CG / LEROY SOMER / LEY POWER
Rating : 415 V., 3Ph. 50 Hz., 62.5 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 62.5 KVA DG set including multi-core control cable and other accessories as required having following secification / features.
i) 125 A , MCCB type ACB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
Supply and fixing of exhaust gas piping of 80mm dia welded black MS class B pipe incl. all necy bend supports and clamps anti vibration mounting insulation of exhaust system with glass wool 25mm thick wire mesh and aluminium cladding incl. suitable clamping/supports arrangment as per situation of site with necessary tools and as per direction of E.I.C. (from DG sets to top of the building plus 3Mtr. or as per CPCB) (FOR 62.5kVA DG)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (For Road Crossing of cable)
65 mm dia.
Supply & Delivery 1.1KV grade PVC/A. XLPE insulated Aluminium armoured cable (Havells /Polycab)
4 Core 70 Sqmm.
Laying of 4 Core 70 Sqmm Cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 70 Sqmm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 70 Sqmm.
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (02 No. for Nutral earthing and 02 No. for Body Earthing).
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Making 3100mm x 1800mm x 1000mm (250mm below & 750mm above the ground level) PCC foundation (ratio 1:2:4) with 3mm thick smooth cement finish including construction of blue scope roofing shade supported onsteel stuucture consisting of atleast 4(four) vertical supports and adequate horizontal support made up of iron pipes with water prof painting on primer, capable of providing protection (Blue Scope Shade) against rain for the DG having dimension 2950mm x 1200mm x 1800mm(hight).
S & F Co2 type fire extinguisher having weight 4.5 KG. (Approved Make)
PABITRA KR SAHA
NIHAR RANJAN SAHA
A.K.CHOUDHURY AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .