Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹32.6 L
EMD Value
₹65,300
Closing Date
30 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RRWD SMC
Executive Engineer RRWD SMC REGAL LANE LAL CHOWK
Development of lawn and other allied works at Community centre Athwajan
2025_HAUDD_298582_1
Short Term NOTICE INVITING E- TENDER No.42 of 2025-2026 RRWD SMC DATED 18.12.2025
Open Tender
Civil Works
Percentage
175 days
Development of lawn and other allied works at Comm
PLEASE REFER TO TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,100
F.A/C.A.O SMC 0216010200000007
₹65,300
18 Dec 2025
18 Dec 2025
31 Dec 2025
18 Dec 2025
30 Dec 2025
18 Dec 2025
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed all kinds of soil
Supplying and laying of Stone Solling including Loading, Unloading,laying etc with all carriages of Headload by manual labour
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge to made of G.I. wire of dia 4 mm
Providing and fixing of balusters to the stair case & other places where required walnut wood (Standard size)
Providing and fixing of Nawal posts to the stair case where required walnut wood
Providing and fixing of hand rail to the stair case & other places where required walnut wood
Providing laying and fixing 50MM thick rubber moulded cement concrete interlock tile of required shape size and colour ( Weight of each tile 5.50 Kg) laid over 50MM (Average) thick sand cushion/levelling coarse, including filling joints with dry mix of 1:4 (1 cement:4 sand) including all leads lifts carriage (Mechanical/manual) complete job
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level hot rolled defprmed bars
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required 0.63 mm thick with zinc coating not less than 275 gram/m2
Elctrical Part LED Down lighter (SMD Type) (System lumen efficacy >135 lm/Watt) , Supplying, installation, Testing & Commissioning of 12-15 Watt LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminum Body including trim.
5/6 Amp modular Switch
3 Pin 5/6Amp Socket outlet
15/16 Amp Switch
6- Pin 15/16Amp Socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req . 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
12 Module (200mm x 150mm) Modular base and cover plate along with GI /PVC box on existing / recess surface as required
8 Module (125mm x 125mm) Modular base and cover plate along with GI/PVC box on existing / recess surface as required
6 Module (200mm x 75mm) Modular base and cover plate along with GI /PVC box on existing / recess surface as required
4 Module (125mm x 75mm) Modular base and cover plate along with GI /PVC box on existing / recess surface as required
3 Module (100mm x 75mm) Modular base and cover plate along with GI /PVC box on existing / recess surface as required
2 Module (75mm x 75mm) Modular base and cover plate along with GI /PVC box on existing / recess surface as required
1mm/1.5mm FRLS PVC insulated CU conductor
2.5mm FRLS PVC insulated CU conductor
4mm FRLS PVC insulated CU conductor
6mm FRLS PVC insulated CU conductor
10mm FRLS PVC insulated CU conductor
16mm FRLS PVC insulated CU conductor
35 mm² Cable (4C) (from LT Line to meter and from meter to LT pannel),1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type
32Amp DP 240/415V, 10KA MCB C Curve
63Amp 2 pole, 240/415V, isolator in the existing MCB DB complete with connections
5 amp, to 32 amps, Single Pole rating 240 volts B/ C / D Series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and Commissioning etc as required
6 amp, to 32 amps, Double Pole rating 240 volts B/ C / D Series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and Commissioning etc as required
Indicators plate on the existing modular plate and switch box excluding modular plate as required
100 Amp TP&N 25K ISI Mark
12 Way (4+36 ) double door , vertical type ,415V , TPN MCB distribution board of sheet steel , dust protected duly powder pained inclusive of 200Amp tinned CU bus bar ,common neutral link ,earth bar , din bar for mounting MCB's (but without MCB's ) as required
300 mm , AC 230/250volts 50 Hz exhaust fan with louvers of following sizes including connection etc complete as required
a. Supply installation testing & commissioning of cubical type LT pannel board suitable for 415V 3 phase 4 wire 50 Hz AC supply system including incomers, outgoing , bus bars interlocking, AMF logic etc including earthing and fixing of panel on the mounting iron stand.The legs of the stand to be rooted in the ground in M20 mix. complete job
3- phase Conventional Energy Meter 20-80 Amp, DLMS Compliant of accuracy class 1.0 (Whole Current )
35 Watt Flood Lights for outdoor illumination (Philips/Wipro/equilant)
8 Mtr Long St Pole (410 SP 15)
GI U-Clamps for Shackle Insulators
50 mm² ACSR Conductor
Galvinized Nuts and Bolts.
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
Red oxide paint
Al Paint
Cement bottoming 1:2:4 mix as per Standards 0.40 cum /pole
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.63 MB
BOQ_967790.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .