Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.0 LAccepted-Finance FIRST FOOR SCF 1 SECTOR 17 FARIDABAD FARIDABAD FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | L1 | Accepted-Finance Quoted lowest rates | |
| 2 | L2₹64.3 L+₹33,984 (0.53%)Rejected-Finance E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | L2 | Rejected-Finance Not Quoted lowest rates | |
| 3 | L3₹66.4 L+₹2.5 L (3.84%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Rejected-Finance Not Quoted lowest rates | |
| 4 | L4₹70.8 L+₹6.8 L (10.6%)Rejected-Finance | L4 | Rejected-Finance Not Quoted lowest rates | |
| 5 | L5₹72.9 L+₹8.9 L (13.9%)Rejected-Finance 1ST FLOOR FLAT NO 103 SCHEME NO 51 234 AVANTIKA NAGAR INDORE INDORE MADHYA PRADESH 452006 | INDORE | MADHYA PRADESH | 452006 | L5 | Rejected-Finance Not Quoted lowest rates |
Tender Value
₹82.3 L
Closing Date
13 Dec 2021, 3:00 pmClosed
Manager(Electrical)
Hall NO. 7, ITPO pragati Maidan New Delhi
Supply, Installation, testing and commissioning of new Air Handling Units along with the related accessories for HVAC Plant for hall no. 8-10 at Pragati Maidan, New Delhi
2021_ITPO_659063_1
169-ITPO(1)E-E/21-22/3041
Open Tender
Electrical Works
Item Rate
365 days
Pragati Maidan New Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
Yes
ITPO
Exempted
Through Vedio Conferencing
11 Feb 2022
23 Nov 2021
14 Dec 2021
23 Nov 2021
13 Dec 2021
6 Dec 2021
29 Nov 2021
Amount
Supplying,Installation,Testing,Commissioning of Double skin floor mounted horizontal Air Handling Unit that has 50 mm thick(EU-4) box type pre filter, coil section with 6 row deep chilled water cooling coil, fan section with DIDW centrifugal backward curved fan, drive set with V- belt and motor (IE3) complete with civil works to fix the new AHUs along with providing & laying of suitable size cables, cabletrays, electrical connection in all respect to make operational and dismantling and buy-back of existing AHUs etc as required with the following specification: MAKE: ZECO Aircon / EDGETECH/SYSTEM AIR / Waves Aircon Panel: Outer skin: not less than 0.8 mm Pre-coated GI, Inner skin: not less than 0.8 mm Plain GI & Thickness: 25 mm thick,CFC Free PUF injected (Density:40 kg/Cu. m) Frame work : Unit base: Heavy duty GSS & Profile: Thermal Break Aluminium profile. Cooling Coil (Chilled water type): Tube material: Copper, Tube thickness: not less than 0.41 mm, Outside dia.: not less than 12.7 mm, Header Material: MS, Coil casing: GI, Fin material: Plain Aluminium, Fin spacing: 11-13 FPI, Condensing Tray: 22G SS-304, Test Pressure: 21 kg/sq. m., Static Pressure : 65mmWG & Insulation material for drain tray: 13 mm thick close cell Nitrile rubber. Filters: Make: Spectrum/Mechmark/Puramatic, Fan(DIDW Type): Make: NICOTRA/ KRUGER/GREENHECK, AC Motor (For DIDW Fans): Make: BHARAT BIJLEE/HAVELLS/ABB/Seimens & Efficiency Factor: IE3 Special features:1. AHUs must be CE certified 2. AHUs should also certified for mechanical and thermal performance as per EN 1886 standard (European Standard) 3.All coils must be AHRI certified as per test standard ARI-410 4. All coils are UL certified for safety.
15000 CFM size AHU
20000 CFM size AHU
30000 CFM size AHU
Supplying,Installation,Testing,Commissioning of new M.S. Chilled water Piping complete with all accessories, duly insulated with 32mm Class "O" Nitrile Rubber Insulation after dismentalling and buyback of existing wornout Piping in existing AHU Rooms at various locations etc. as required. MAKE: SAIL/JINDAL/TATA
Supplying,Installation,Testing,Commissioning of following dia M.S. Drain Pipe duly insulated with 32mm Class "O" Nitrile Rubber Insulation after dismentalling and buyback of existing wornout Piping in existing AHU Rooms at various locations etc. as required. MAKE: SAIL/JINDAL/TATA
Supplying,Installation,Testing,Commissioning of following sizes Manual Butterfly Valve with SS Disc complete with all accessories and duly insulated with 32mm Class "O" Nitrile Rubber Insulation after dismentalling and buyback of existing wornout Valve in existing AHU Rooms at various locations etc. as required. MAKE : SANT/CASTLE/ AUDCO/ ADVANCE/ZOLOTO
Supplying,Installation,Testing,Commissioning of following sizes Balancing Valve Valve with SS Disc complete with all accessories and duly insulated with 32mm Class "O" Nitrile Rubber Insulation after dismentalling and buyback of existing wornout Valve in existing AHU Rooms at various locations etc. as required. MAKE : SANT/CASTLE/ AUDCO/ADVANCE/ZOLOTO
Supplying,Installation,Testing,Commissioning of following suitable sizes 2 Way / 3 Way Motorized Valve with Actuator, Thermostat and Wiring complete with all accessories, duly insulated with 32mm Class "O" Nitrile Rubber Insulation after dismentalling and buyback of existing wornout Valve in existing AHU Rooms at various locations etc. as required. MAKE: DISTECH/JCI/HONEYWELL/SIEMENS
Suitable for 80mm CHW Pipe Line
Suitable for 65mm CHW Pipe Line
Suitable for 50mm CHW Pipe Line
Supplying,Installation,Testing,Commissioning of IP Based BACNet BMS Standalone 32 Bit Controllers suitable for AHU Automation (2 AHU Per Controller ) alongwith DDC Panel Enclosure complete with copper conductor Internal Wiring, Power supply and other accessories required for DDC Panel to function, in existing AHU Rooms at various locations etc. as required. MAKE: DISTECH/JCI/HONEYWELL/SIEMEN
Supplying,Installation,Testing,Commissioning of following add on accessories/modifications for the existing IP Based BACNet BMS Standalone Controllers complete with copper conductor Internal Wiring in existing AHU Rooms at various locations etc. as required.
Duct type Return Air Temperature. MAKE: DISTECH/JCI/HONEYWELL/SIEMENS/DWYER
Curent Relay. MAKE: ABB/SIEMENS/ALSTHOM/UNIVERSAL
Accessories in AHU Electrical Starter Panel / necessary modifications to make it compatible for BMS.
2C*1.0Sqmm ATC Armoured Signal Control Cables Required for Connecting AHU, Field Devices, Electrical Panel & DDC Enclosure. MAKE: POLYCAB/FUSION POLYMER/BATRA HENLEY
Supplying,Installation,Testing,Commissioning of following accessories with necessary insulation etc. in existing AHU Rooms at various locations etc. as required.
Temperature Gauge. MAKE :H.GURU/FIEBIG/WIKA
Pressure Gauge. MAKE : H.GURU/FIEBIG/JASPIN
25mm Size Drain Valve. MAKE : SANT/CASTLE/ AUDCO/ ADVANCE/ZOLOTO
Auto Purge Valve. MAKE : SANT/CASTLE/ AUDCO/ ADVANCE/ZOLOTO
Repairing of damaged portion of Supply Air Plenum by providing and fixing 20SWG GI sheet in existing AHU at various locations etc. as required. MAKE: SAIL/JINDAL/TATA
Repairing,Testing,Commissioning of existing VFD for AHUs of 13000 CFM to 30000 CFM capacity including replacement of mother board,display card capacitor card etc. to make VFD functional and integration with mixing valve through new controller in new AHUs at various locations etc. as required(repairing of VFD must be done by authorised OEM agency) Make: ABB
Supertech Engineers
Blue Star Limited
SM AIRCONDITIONING ENGINEERS
G. D. Enterprises
welcome engineers
snowmex engineers ltd
JUHI AND JAI CONTRACTORS PVT LTD
AIR CARE REFRIGERATION SYSTEM PVT. LTD.
CONSENSUS INDUSTRIAL SOLUTION
V.K Enterprises
HV AIRCONDITIONING SYSTEMS PVT. LTD.
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .