Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC 10 BRIJ VATIKA LAXMIPURA JAIPUR RAJASTHAN 302022 | JAIPUR | JAIPUR | RAJASTHAN | 302022 | L1 | Accepted-AOC Awarded by competrent authority |
Tender Value
₹2.8 L
EMD Value
₹5,571
Closing Date
17 Feb 2025, 4:00 pmClosed
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Repairing and replacement of various faulty items in EI and Fans at TE Bldg. Jharkhnadi, Dismantling, repairing,replacement of faulty submersible motor pump set in staff Qtr colony Civil Line ,OA Gorakhpur.
2025_BSNL_225877_1
37/TED/GKP/2024-2025
Open Tender
Electrical Works
Item Rate
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹5,571
28 Mar 2025
5 Feb 2025
19 Feb 2025
5 Feb 2025
17 Feb 2025
5 Feb 2025
Replacement of conventional 40 w tube fitting with 20 W LED tube fitting i/c connection,testing etc .complete as reqd.
Repairing /rewinding of 1200 MM Sweep Ceiling fan i/c replacement of faulty condensor, bearing, bush,oiling greasing etc complete as reqd.
Repairing /rewinding of 300/450 MM Sweep Exhaust fan i/c replacement of faulty condensor, bearing, bush,oiling, greasing etc complete as reqd.
Replacement of 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
Replacement of following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 Amp
Providing and installation of 300mm exhaust fan suitable for operation on 230 V ,50 Hz AC supply i/c cutting the wall,making good the damages etc. and all accessories, connection,testing etc complete as reqd. (Make - Crompton or similar superior make)
Supply and Fixing of 450 mm air circulating fan suitable for 220-240V,50HZ ac supply i/c connection, testing etc as reqd. (Make-Crompton or SS make)
SITC of 24 hours analog timer for exhaust /air circulating fans i/c providing suitable size PVC switch box for enclosure of the timer i/c connections etc as reqd. (make Havells or SS make)
Supply and Fixing of 2x1.5 sqmm round copper cable i/c connection, testing etc as reqd.
Providing and fixing of GI duct made out of 16 SWG CRCA sheet for fixing at the out let of exhaust fan,approx.size 300x300x300 and bend at the end & jali to restrict entry of water and stray particles i/c making good the damages etc as reqd.
Replacement of 63 Amp Kit Kat fuse unit i/c fixing, connection, etc complete as reqd. (M/S L&T/Havells/S.s make)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2x 1.5 sqmm
(b) 2x2.5 sqmm
Supply and Fixing of 1200 mm sweep ceiling fan fan i/c connection, testing etc as reqd.
Supply and Fixing of electronic regulatorfor ceiling fan fan i/c connection, testing etc as reqd.
Replacement of following faulty items in existing switch boards/ LT panels etc. i/c connection, testing etc. complete as required. (a) 5 A switch
(b) 5 Amp 3pin Socket
(c ) 15 Amp Switch
(d) 15 Amp 6pin Socket
(e)125 Amp 4 pole Changeover
(f) 63 Amp TPN SFU
(g) 63 Amp HRC fuse
Supply of 5.0 HP capacity submersible motor pump set suitable to operate on 3 phase 415 volt AC supply and capable to lift water upto 3rd floor building. Pump shall be of 14 stage, with head range 23-70 M and discharge flow range shall be 9-24 cum/hr. on operating speed 2900 RPM.i/c replacement of damaged rubber packing, nut,bolts,flange , reducer etc as reqd. (Make - KSB Model- 18C/14G-UMAI or similar superior make)
Labour charges for lifting of the old/faulty submersible pump from the borewell with the help of tripole and pulley arrangement and lowering of the new submersible pump in to the borewell i/c replacement of damaged rubber packing, nut,bolts,bend, reducer etc as reqd.
Supplying and fixing of direct on line motor starter having contactor coil 360 volt rating and over load relay of 9-14 amp range for protection of the motor. It shall have start/stop push buttons and ampere and volt meters of suitable range i/c connection, testing etc as reqd. (M/s L&T Model No MU-G6 or Similar Superior make)
Replacement of 32 Amp 3 Pole isolator i/c fixing, connection, etc complete as reqd. (M/S L&T/Havells/S.s make)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .