Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 CrAccepted-AOC WARD NO 1 CHHAJU PURAM COLONY RAILWAY ROAD MOHINDERGARH 123029 | MAHENDRAGARH | HARYANA | 123029 | ₹6.8 Cr Quoted ₹7.0 Cr | L1 | Accepted-AOC Lowest rates |
| 2 | L2₹7.4 Cr+₹37.9 L (5.42%)Rejected-AOC 2339 4 NEHRU COLONY 2339 4 NEHRU COLONY JIND ROAD ROHTAK 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹7.4 Cr+₹37.9 L (5.42%) | L2 | Rejected-AOC higher rate |
Tender Value
₹6.8 Cr
EMD Value
₹13.5 L
Closing Date
14 Jan 2025, 9:00 amClosed
OM DUTT
Municipal Corporation Faridabad
DEVELOPEMENT OF COMMUNITY CENTRE / STADIUM AT VILLAGE NACHAULI FARIDABAD
2024_HRY_420701_1
2024CA394550 BBC8 498C AB29 75C929D6A5B0284ULB
Open Tender
Civil Works
Works
365 days
Faridabad (MC)
2 documents required · 2 mandatory
₹5,000
Yes
₹13.5 L
Yes
13 May 2025
30 Dec 2024
15 Jan 2025
30 Dec 2024
14 Jan 2025
30 Dec 2024
30 Dec 2024 - 1 Jan 2025
Amount
Material required- Mechanical and Electrical works, detail given below. Supply and fixing of 2½” Pump Nipple G.I. new making with flange
Supply and fixing of 2½” MS Clamp HD
Supply and fixing of Panel box Hut
Supply and fixing of 4” Tee (4”x4”x4” C.I. tee) ISI
4” Duck foot Bend C.I. ISI
4” CI Bend ISI
4” Horizontal Pipe with Flange
Labour charge for making tee connection with existing line excavation, cutting, jointing and making and making connection with existing line complete in all respects
Resistivity testing charges for checking of water/strata etc.
Supply and Erection of LED flood light luminaries make Bajaj, Phillips, Surya, Crompton, Havells etc. with ultra sleek, light weight and with secondary optics, made of pressure die-cast housings with IP66 ingress protection and impact resistance of IK07. 4KV inbuilt and 10 KV* external surge protection complete in all respect upto the entire satisfaction of Engineer-In Charge of the work.
Digital time switch (corono) LandT make 110-240 VAC,IC/o BASE/DIN 25 ON/OFF (Cat No. 67DDTO) make:-LandT, Conforms to IS/IEC 60947-4-1 and IEC 60947-4-1 The cost includes installation connection with timer and MNX contactor, energy line and maintaining the system for 2 years sending the operator for resetting with timer if any disturbance or fault replacing if burn due to single facing guarantee complete up to 2 years after installation of energy meter. Complete replacement in case of burning, accident due to whatever reason.
Supply and erection of PVC copper insulated and sheathed 3-core circular flexible wire make Havells, KEI, Kalinga, Polycab etc. Size 2.50 sqmm (80/0.20mm)
cost of connection charges for 1Nos. Electric Connection to be deposit with DHBVN including file charges, security, testing charges, energy meter etc. load 10HP Motor
3 pole power contactor Type MNX 110 make LandT Aux. Contacts (2No.=2Nc), Cat No. CS94137, AC3 Rating 110 Amp. Conforms to IS/IEC 60947-4-1 and IEC 60947-4-1 The cost includes installation connection with timer and MNX contactor, energy line and maintaining the system for 2 years sending the operator for resetting with timer if any disturbance or fault replacing if burn due to single facing guarantee complete up to 2 years after installation of energy meter. Complete replacement in case of burning, accident due to whatever reason. Note: Rate has been taken from work order no. MCF/EEElect/2022/1070 dated 29.08.2022
Providing and fixing three phase 25 KW energy meter along with installation of 63 KVA, 11 KV / 433-volt transformer with its infrastructure for providing the connection. The same is to be done by DHBVNL. The rates are taken from DHBVNL rate list (copy attached) and DHBVNL website.
Supply and erection of underground armored cable, make Havells, KEI, Kalinga, Polycab etc. loose in existing pipe or trenches complete with necessary connections. 25 Sq. mm 4 Core armored alumium Cable.
S/E of hot dip galvanized single arm bracket with each arm of 50 mm dia MS PIPE 1500 MM long (3.2 mm thick) duly welded with 450 mm long 3 mm thick octagonal canopy of suitable dia (3 mm thick) with angle of inclination 105 degree of the vertical. The top end of canopy should be closed with MS sheet of 16 SWG. The 25 mm dia MS pipe (2mm thick). The rates are inclusive of cutting, welding and all labour charges. The bracket shall be as per design and drawing enclosed complete in all respect. Single Arm
Making Sewer Connection
supply of good earth complete as per site requirement
nut bolt
Bidder Name
Amount
PRP INFRACONE (GSTN-NA) BID ID -1193864
Praveen Construction (GSTN-NA) BID ID -1199903
PRP INFRACONE (BID ID -1193864)
PRP INFRACONE (BID ID -1193864)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .