Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 35 MODEL TOWN G T ROAD JANDIALA GURU DISTRICT AMRITSAR | JANDIALA GURU | AMRITSAR | PUNJAB | L1 | Accepted-AOC accepted | |
| 2 | L2₹29.9 L+₹8,734 (0.29%)Rejected-AOC | L2 | Rejected-AOC rejected |
Tender Value
₹26.5 L
EMD Value
₹53,084
Closing Date
19 Jun 2023, 12:00 pmClosed
Executive Engineer,Kandi Canal-3,WRD,PB.Hoshiarpur
Executive Engineer,Kandi Canal-3,WRD,PB.Hoshiarpur
Restoration of Damaged Underground Outlet at RD 2787mRight side of Kandi Canal Stage 2 Hoshiarpur
2023_WR_103571_1
26
Open Tender
Civil Works - Canal
Item Rate
30 days
Village Mugowal Distt. Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
₹53,084
Yes
18 Sept 2023
3 Jun 2023
19 Jun 2023
3 Jun 2023
19 Jun 2023
3 Jun 2023
Amount
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for All classes of soil except rocky
Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete. C.I Single air valve screwed (Size 50mm)
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m.
Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. Capacity of Air compressor 300 cfm at 250 PSI
Providing, Laying , fixing & jointing of 225 mm U.P.V.C. socketed (2.5 kg pressure) Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Providing, Laying , fixing & jointing of 250 mm U.P.V.C. socketed (2.5 kg pressure) Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge
Providing, Laying , fixing & jointing of 280 mm U.P.V.C. socketed (2.5 kg pressure) Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
Providing and fixing ISI Marked 225 mm dia Alfa Valve
Providing and fixing ISI Marked 250 mm dia Alfa Valve
Providing and fixing ISI Marked 280 mm dia Alfa Valve
providing and fixing 225 mm Long bend (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 250 mm Long bend (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 280 mm Long bend (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 225 mm Long bend (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 280 mm Socket (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 225 mm Equal- T (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 250 mm Equal- T (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Brick Work First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
PLASTERING & POINTING 12.5 mm thick cement plaster 1:4
Providing and fixing ISI Marked 300 mm dia Alfa Valve
Providing, Laying , fixing & jointing of 300 mm U.P.V.C. socketed (2.5 kg pressure) Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications
Providing and fixing 300 mm Long bend (6kg/cm2 pressure) conforming to IS codes with latest amendment's if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 300 mm Socket (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 280 mm Equal- T (6kg/cm2 pressure) conforming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 300 mm Equal- T (6kg/cm2 pressure) conforming to IS codes with latest amendment's if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Providing and fixing 250 mm Socket (6kg/cm2 pressure) conferming to IS codes with latest ammendments if any of site if work including loading, in-loading and re- handling if any complete in all respects as per design and PWD specifications and instructions of engineer in charge
Any other item
The Lambra Co Operative L and C Society Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .