Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC PULWAMA JAMMU KASHMIR 192301 INDIA | PULWAMA | JAMMU AND KASHMIR | 192301 | ₹20.4 L Quoted ₹21.7 L | L1 | Accepted-AOC ACCEPTED. BEING THE L1 BIDDER. |
| 2 | L2₹25.2 LRejected-AOC C 11 100 SAIPRASAD CHSL MALWANI MHADA MALAD W MUMBAI 95 | MUMBAI SUBURBAN | MAHARASHTRA | 400095 | ₹25.2 L | L2 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. |
| 3 | L3₹28.4 LRejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹28.4 L | L3 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. |
| 4 | L4₹32.3 LRejected-AOC WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹32.3 L | L4 | Rejected-AOC REJECTED AS NOT BEING THE LOWEST BIDDER. |
| Sl No | Description | Qty | Unit | Mayur Enterprises L4 | M/s Mukesh Engineers L3 | Peerzada And Sons L1 | PICON ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials outside MD and including necessary scaffoldings complete all as specified and directed. | 200 | Sqm | 30 ₹6,000 | 10 ₹2,000 | 50 ₹10,000 | 10 ₹2,000 |
| 2.00 | M&L for rendering 15mm thick in (1:4) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed. | 200 | Sqm | 250 ₹50,000 | 200 ₹40,000 | 180 ₹36,000 | 260 ₹52,000 |
| 3.00 | M&L for preparation and cleaning new RCC of inside surfaces of wall, bottom of Dome of Over Head or UG Sump Reservoir Tank by brush and treating surfaces with the methodology as under:-
(a) Seal sanitary pipes entering through the walls and floor with Dr. Fixit Bathseal Tape (or equivalent as approved by GE) and grout the gaps with Dr.Fixit Bathseal grout - a non shrink cementitious grout (or equivalent as approved by the GE). (b) Apply the first coat of Dr. Fixit Fastflex (or equivalent as approved by GE) maintaining the saturated surfaces in dry condition. (c) Embed a glass fibre mesh measuring 50 gsm over and including the angle fillets as a reinforcing strip and allow it to soak completely. (d) Immediately apply the second coat of Dr. Fixit Fastflex (or equivalent as approved by GE) to sandwich this glass fibre mesh between these two coatings. (e) Apply the third coat of Dr. Fixit Fastflex (or equivalent as approved by GE) and sprinkle coarse sand while it is still wet. (f) Subsequent to above, apply first brush coat of Dr. Fixit Dampguard (or equivalent as approved by GE). Allow drying for 6 to 7 hours then apply second brush coat of Dr, Fixit Dampguard (or equivalent as approved by GE). Allow it to sure completely set in position for 24 hours before using. | 200 | Sqm | 590 ₹1.2 L | 1,700 ₹3.4 L | 150 ₹30,000 | 900 ₹1.8 L |
| 4.00 | M&L for rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed. | 100 | Sqm | 200 ₹20,000 | 260 ₹26,000 | 180 ₹18,000 | 250 ₹25,000 |
| 5.00 | M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oi emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed. | 20 | Sqm | 65 ₹1,300 | 100 ₹2,000 | 60 ₹1,200 | 60 ₹1,200 |
| 6.00 | M&L for preparation of old plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed. | 40 | Sqm | 65 ₹2,600 | 100 ₹4,000 | 60 ₹2,400 | 60 ₹2,400 |
| 7.00 | M&L for rendering 20mm thick in (1:4) cm (in two coats (15+5mm) with both coats mixed with liquid water proofing compound, surface finished even and fair without using extra cement c‹;mplete all as specified and directed. (Note : WPC will be measured separately). | 200 | Sqm | 260 ₹52,000 | 300 ₹60,000 | 240 ₹48,000 | 280 ₹56,000 |
| 8.00 | M&L for for preparation of new plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and indluding necessary scaffolding complete all as specified and as directed. | 200 | Sqm | 80 ₹16,000 | 100 ₹20,000 | 90 ₹18,000 | 90 ₹18,000 |
| 9.00 | M&L for preparation of old plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and including necessary scaffolding complete all as specified and as directed. | 50 | Sqm | 80 ₹4,000 | 110 ₹5,500 | 80 ₹4,000 | 90 ₹4,500 |
| 10.00 | M&L for rendering 5 mm thick in CM 1:3 as in ceiling finishing even and smooth (without using extra cement) etc complete all as specified and directed, | 50 | Sqm | 200 ₹10,000 | 160 ₹8,000 | 280 ₹14,000 | 200 ₹10,000 |
Tender Value
₹36.4 L
EMD Value
₹72,800
Closing Date
3 May 2025, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
PROVISION OF COVERED HARD STANDING NEAR BLDG. P-35 AND ADDITION/ ALTERATION AND SPECIAL REPAIRS TO STATIC WATER TANK AT INS HAMLA UNDER GE (NW) BHANDUP
2025_MES_698170_3
8393/B
Open Tender
Civil Works
180 days
HAMLA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹72,800
Yes
20 Jun 2026
12 Apr 2025
5 May 2025
12 Apr 2025
3 May 2025
19 Apr 2025
12 Apr 2025 - 15 Apr 2025
Amount
Taking down cement mortar or lime plaster of any description from stone or brick wall etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials outside MD and including necessary scaffoldings complete all as specified and directed.
M&L for rendering 15mm thick in (1:4) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparation and cleaning new RCC of inside surfaces of wall, bottom of Dome of Over Head or UG Sump Reservoir Tank by brush and treating surfaces with the methodology as under:- (a) Seal sanitary pipes entering through the walls and floor with Dr. Fixit Bathseal Tape (or equivalent as approved by GE) and grout the gaps with Dr.Fixit Bathseal grout - a non shrink cementitious grout (or equivalent as approved by the GE). (b) Apply the first coat of Dr. Fixit Fastflex (or equivalent as approved by GE) maintaining the saturated surfaces in dry condition. (c) Embed a glass fibre mesh measuring 50 gsm over and including the angle fillets as a reinforcing strip and allow it to soak completely. (d) Immediately apply the second coat of Dr. Fixit Fastflex (or equivalent as approved by GE) to sandwich this glass fibre mesh between these two coatings. (e) Apply the third coat of Dr. Fixit Fastflex (or equivalent as approved by GE) and sprinkle coarse sand while it is still wet. (f) Subsequent to above, apply first brush coat of Dr. Fixit Dampguard (or equivalent as approved by GE). Allow drying for 6 to 7 hours then apply second brush coat of Dr, Fixit Dampguard (or equivalent as approved by GE). Allow it to sure completely set in position for 24 hours before using.
M&L for rendering 15mm thick in (1:6) CM on fair faces of brick work or concrete surfaces of walls and finishing even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oi emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of alkali resistant primer using roller etc complete all as specified and directed.
M&L for rendering 20mm thick in (1:4) cm (in two coats (15+5mm) with both coats mixed with liquid water proofing compound, surface finished even and fair without using extra cement c‹;mplete all as specified and directed. (Note : WPC will be measured separately).
M&L for for preparation of new plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and indluding necessary scaffolding complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls, chajjas, slab projections and applying two coats of 100% Anti fungal acrylic emulsion paint in approved shade over a coat of primer and including necessary scaffolding complete all as specified and as directed.
M&L for rendering 5 mm thick in CM 1:3 as in ceiling finishing even and smooth (without using extra cement) etc complete all as specified and directed,
M&L for preparation of old plastered surfaces and applying two coats of white wash on ceiling etc complete all as specified and directed
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling etc complete all as specified and directed.
M&L for Removal of plant growth by injection with chemical glyphospate solution (4 % conceneration) @ 20ml or till refuse by cutting or injection in stem of plants or roots at 30mm. The area shall then be sprayed with solution 25ml glyphosphate (4 % conceneration) diluted with 1 ltr of water. All roots/ plants shall be removed completely and making good the distrubed surface and painted with cement base or acrylic paint all as directed by EIC.
Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land. Complete all as specified and directed.
M&L for brick work with sub class ‘B' bricks straight or curved on plan exc. 6m mean radius built in CM (1:6) for MH complete all as specified and directed.
Dismantling/Demolition of existing roof terracing of cement/brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to remove all dust/dirt and loose particles to expose bare concrete roof slab and removal of rubbish/demolished material outside MD land complete all as specified and directed. Note:- Demolition should be done by chiselling.
M&L brushing neat cement slurry @ 3 Kgs of cement per Sqm. Complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on roof finished even and smooth using liquid water proofing compound as per manufacturers instructions. Complete all as specified and directed. (Note:- Supply only liquid water proofing compound shall be measured & paid separately).
M&L for PCC 1 : 2 : 4 type B0 (using 12.5mm graded stone aggregate) as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc mixed witii approved water proofing compound all as per manufacturer's instructions on the roof surface to achieve requisite slope all as specified and directed. (Note:- Supply only water proofing compound shall be measured & paid separately).
Supply only polymer based liquid water proofing compound complete all as specified and directed.
M&L for providing 4 mm thick APP modified membrane in repairs including removing old treatment over (lnaccessible) RCC roof with the following specifiations :- (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 - 0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyester matt with physical propertities as under:- (i) Membrane weight >3.6 Kg/Sqm . (ii) Net wooven polyester weight >160 gm/Sqm (iii) Softening point of membrane > 150ºC (iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230ºC & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction. (vi) Elongation > 30 % (vii) lmpermeability under water pressure > 3 Kg/Sq cm. Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane. (d) Over the membrane provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kq/Sqm as prescribed by manufacture of membrane.
Removing loose concrete carefully by low impact hammer bracker or manually by chisel and hammer mechanisam including necessary scaffolding and removal of debris out of MD land. Complete all as specified and directed. REHABILITATION WORK ITEMS 22 TO 28. Note:- 1. Rehabilitation works is to be carried out by the authorised rep / applicator of the manufacturer and will render certificate at the stages to the effect that work / methodology has been executed / adoped as per the prescribed norms. 2. The rate for rehabilitation works Includes necessary scaffolding, form work, steel props, and safety works like barricade, safety net, dust net etc as per site requirement.
M&L for applying rust remover on existing reinforcement and before application of protective coating the surface should be wire brush and throughly cleaned for dust complete all as specified and directed. Note:- Mode of measurement shall be for the superficial area of concrete scaled only. Make: Foevert of Krishna Conchem or equivalent.
M&L for applying of anti Corrosive primer for exposive steel reinforcement complete all as specified and directed. Make:- IP Net RB of Krishna Conchem or equivalent.
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster or micro concreting conforming ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bonding between old concrete and new concrete. Complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar upto 20mm thickness including levelling, profiling etc complete all as specified and directed. Make: Molith PMM of Krishna conchem or equivalent. Note:- Mode of measurement: Superficial area of concrete will be measured.
M&L for building up the profile of structural members using polymer modified mortar upto 40mm thickness including levelling, profiling etc. Complete all as specified and directed. Make: Molith PMM of Krishna conchem or equivalent. Note :- Mode of measurement : Superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from M/s. Krishna Conchem (Molith MC) or equivalent of Dr. Fixit as approved by GE at any level and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing, laying, levelling, finishing, curing etc as per manufacturer's specifications complete all as specified and directed. (Note: Reinforcement only shall be measured and paid separately).
M&L for Cement concrete type B-2, 1:2:4 (using 40 mm, graded stone aggregate) 100 mm thick laying in floor/ paving and spike rolling-to surfaces or making impressions of expanded metal, whilst the concrete is green and using require form work complete all as specified and directed.
Dismantling floor, hearth or wall tiling any description and thickness including cement mortar bedding (but not backing) and removing rubbish off the premises.
M&L for PCC 30mm thick type B0, 1 : 2 : 4 (12.5 mm graded aggregate) in sub flooring complete all as specified and directed.
M&L for glazed ceramic jointless coloured tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm set and jointed in neat cement slurry over and including provision of bedding layer 10mm thick in CM 1 : 3 complete all as specified and directed.
M&L for Machine cut kota stone slab 20-25mm thick over cement screed base and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over in floors over incl 20 mm thick screed bed in cement mortar 1:4 over including finishing even and fair complete all as specified and directed.
M&L for Cement concrete type D-2 , 1 : 4 : 8 (using 40 mm, graded stone aggregate ) 75 mm thick laying in floor/ paving complete all as specified and directed.
M&L for Machine pressed precast concrete inter locking paver blocks of any shape and size conforming to IS 15658- 2006 of 60 mm thick M-35 grade with grey cement and pigment with glossy finish and including removing the existing paver blocks complete all as specifiecl and directed.
M&L for cement concrete type C-1, 1:3:6 (20 mm graded aggregate) 75 mm thick as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Demolition of Reinforced concrete in chajjas wall retaining wall and similar suspended, slab facia drop wall etc work complete all as specified and directed.
M&L for reinforced cement concrete with design Mix M-30 using 20mm graded stone Walls, retaining walls. basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete alt as specified
Formwork to faces of walls, retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter curved surface complete all as specified and directed.
M&L for RCC 1 : 2 : 4 type B1 Nominal mix (using 20mm graded stone aggregate) in chajjas complete all as specified and directed .
S&F of TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for form work for soffit and sides of chajjas, troughs and similar items including edges rough finished surface of concrete flat complete all as specified and directed.
S&F in repairs Steel rolling shutters 1.25mm thick lath, with out ball bearing, as specified including top cover, locks mild steel with 4 levers, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with bevel gear box and crank handle.
M&L Two coat of aluminium paint over a coat of alumimium red oxide primer to new steel surface including preparation complete all as specified and directed.
Dismantling of wrought iron or mild steel work in any description and in any position complete all as specified and directed.
M&L rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc conforming to Fe 410-W (Gde-E-250) complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing. framing for cladding made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc.. of required size, on the top of floor or the side of waist slab with suitable arrangement. complete all as specified and directed.
M&L for expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0,9mm dia or fixing with galvanised steel staples supplied and fixed weight per exc 4 kg / sqm square metrecomplete to wood or steel members. complete all as specified and directed.
M&L for 2 mm thick Plain colour PVC sheet fixed to Aluminium door,flush doors by u & fixing with and including 'F/U' channel not less than 1.5mm thick complete all as specified and directed. at site as per specification complete all as specified and directed.
Taking down chowkats of frames with shutters (without taking off shutters from frames) area exceeding 1.50 Sqm but n exc 4 sq. m each, including cutting holes for taking out hold fasts of dismantling brick work (holes cut and any other damages to jambs , walls for taking out hold fasl shall be finished idetical to existing finish without any extra cost of Govt) all as specified and directed by EIC.
Taking down door / window shutter of any description exc 1.00 but n exc 2.00 sqm each and refixing in the same opening after easing, adjusting & renewal of unserviceable screws etc complete all as specified and directed.
S&F stainless steel butt hinges medium weight 100mm long. complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long. complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 300 mm complete all as specified and directed.
M&L extruded aluminium alloy handles, fabricated type, anodised 150mm size. complete all as specified and directed.
S&F extruded Powder coated aluminium section as in Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and all directed.
S & F aluminium grill conforming to DG- 102 of Deco Grill or equivalent, (10mm X 5.2mm) thick of approved design or equivalent as approved by Accepting Officer and fixing with and including 'F/U' channel not less than 1.5mm thick complete all as specified and directed.
S&F Aluminium alloy wire cloth, 0.45mm nomina! dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples or aluminium f putty complete all as specified and directed.
Dewatering fromu UG sump by using mechanical pump set and discharging for disposal out side the MD land and spreading required bleaching powder over the area complete all as per specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Excavating in trenches, not exc. 1.5m wide & not exc. 1.5m in depth; for laying pipes etc and getting out in hard/dense soil all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M&L PCC (1:4:8) Type D-2 using 40mm graded stone aggregate) as in foundation filling. All as specified and directed.
Excavating in post holes (or similar holes) Each not exc. 0.5 cu. M, getting out in soft/loose soil returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for PCC 1:2:4 type B1, using 20mm graded stone aggregate in lintel band, roof band, copings and bed blocks for holdfasts complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, post or flat sections) including distance pieces, cleats etc. Fe-410- W(Gde-E-250) quality-B including distance pieces, cleats plate etc incl required welding as per relevent IS complete all as specified and directed.
S&F rolled mild steel work in plates (plain or chequered) channels, square cut or notched (ordinary and countersunk) forming holes, without any attachment, Fe 410-W (Gde-E-250) quality-B, complete all as specified and directed.
M&L for Preparation of new steel surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. All as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based orrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level). All as specified and directed.
M & L for hard core of gauge n.exc. 63mm,depasited, spread and leveled in layer n.exc 15 cm thick, watered and rammed to a true surface with broken stone of boulder. All as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) for MH complete All as specified and directed.
M & L for 15+5 mm thick ready mix plaster using WPC @ 2% by weight of cement on brick work or concrete surfaces; surfaces finished even and smooth including necessary scaffolding complete all as specified and directed. Note: Water proofing compound shall be measured & paid seperately.
M & L for preparation of new plastered surfaces and applying two coats of cement base paint over one coat of alkali resistant primer on wall complete all as specified and directed
M & L for 100 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in sub base to floors and pavings complete all as specified and directed.
M & L for sand filling 50 mm under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M&L for chequered cement concrete tile 20CM x 20CM x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 4, 20mm thick complete all as specified and directed.
S&F for 60 mm thick non skid pre polished coloured inter locking paver block made with eiectro vibro technology with rubber /pvc moulded of not less then compresive strength 30 Kg / cm shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigments complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 1,25,385.80 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2: The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
PICON ENTERPRISES (BID ID -3288183)
M/s Mukesh Engineers (BID ID -3288111)
Mayur Enterprises (BID ID -3286230)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid