Tender Value
₹7.5 L
EMD Value
₹14,902
Closing Date
27 Aug 2026, 3:00 pm4d left
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
SITC of Auto-Sequential Timer Panel in Different Sites at IIT Delhi
2026_IIT_922699_1
IITD/WORKS (SP-5379)/2026
Open Tender
Miscellaneous Works
Works
30 days
IIT Delhi, Hauz Khas
As per tender documents
13 documents required · 13 mandatory
₹0
₹14,902
19 Aug 2026
19 Aug 2026
28 Aug 2026
19 Aug 2026
27 Aug 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of two AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR TWO AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, "C"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , "C"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-1.5 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 1 no., (d)2A SP, MCB, "C" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, "C" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD) | 3 | Nos | - | - |
| 2 | Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of three AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR THREE AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, "C"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , "C"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 2 no., (d)2A SP, MCB, "C" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 2 no. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, "C" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD) | 2 | Nos | - | - |
| 3 | Supply, installation, connections, testing and commissioning of sequential timer panel for automatic operation of four AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR FOUR AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, "C"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , "C"-Curve -3 nos. AC3 Type category 2 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 2 no., (d) 2A SP, MCB, "C" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 02 nos. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, "C" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40 m x 0.20m) (LxWxD) | 2 | Nos | - | - |
| 4 | commissioning of sequential timer panel for automatic operation of five AC units with manual provision and settable / adjustable time slot comprising following components etc. complete as required. TIMER PANEL FOR FIVE AC (a) Suitable size sheet steel enclosure of 2/1.6 mm thick duly powder coated painting with IP-42 protection, (b) 40 A DP MCB, 10kA, "C"-Curve - 1 nos., RYB Indicating Lamps, 22.5 mm Dia LED Type -1 nos., 2A SP, MCB 10kA , "C"-Curve -3 nos. AC3 Type category 3 Pole power contactor ML-3 type - 02 nos., (c) Analog GIC type Quartz Timer 240 VAC - 24 hour - 3 no., (d) 2A SP, MCB, "C" Curve (e) LED type ON indication lamp, (f) Illuminated type ON-OFF push button, (g) Auto - Manual Selector / Toggle switch, 02 nos. (h) Aux Contactor for NO + NC - 02 nos. (i) SMC / DMC Connector with nuts & bolts as required, (j) Internal copper wiring with not less than 4.0 sqmm copper wire, (k) CRCA Powder coated enclosre with opening door of not less than 16 SWG thick, (l) Analog ammeter & voltmeter (m) 20A DP, MCB, 10kA, "C" Curve (Panel drawing must be got approved from Engineer-in-charge before finalisation). Size:- (0.45m x 0.40m x 0.20m) (LxWxD) | 3 | Nos | - | - |
| 5Supplying and Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Acceptable make: Any reputed make) | |||||
| 5.1 | 4 Core x 16 sqmm armoured | 60 | Metre | - | - |
| 6Providing and fixing following capacity TP&N MCCB inside with sheet steel enclosure including drilling holes, making connections, etc. as required. | |||||
| 6.1 | 40 A TP&N MCCB | 2 | Nos | - | - |
| 7Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 7.1 | 3 X 4.0 sq. mm | 320 | Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_969612.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].