Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.0 LAccepted-AOC | L-1 | Accepted-AOC final L-1 bidder | |
| 2 | L-2₹42.4 L+₹5.8 L (15.8%)Rejected-AOC 78 PARASI NEAR PRIMARY SCHOOL PARASI RENUSAGAR RENUSAGAR RENUSAGAR SONBHADRA UTTAR PRADESH 231218 | SONBHADRA | UTTAR PRADESH | 231218 | L-2 | Rejected-AOC L-2 bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Fulfill PQC | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Fulfill PQC | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Fulfill PQC |
Tender Value
₹38.0 L
EMD Value
₹40,000
Closing Date
22 Jul 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
Office of the Superintending Engineer, Operation and Maintenance Circle-II, ATPS, Anpara Thermal Project, Anpara, Dist. Sonebhadra (UP)
Routine and breakdown maintenance of Turbine and Aux. of Unit No. 1, 2 and 3 of 3x210 MW, ATPS, Anpara.
2024_RVUNL_933878_1
03/TMD/OMC-II /ATPS/2024-25
Open Tender
Power/Energy Projects/Products
Fixed-rate
365 days
ANPARA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
Dy. C.A.O., C.F.A. and B.O., ATPS, Anpara
₹40,000
5 Oct 2024
29 Jun 2024
23 Jul 2024
29 Jun 2024
22 Jul 2024
29 Jun 2024
Amount
Round the clock up-keeping and maintenance of Turbine and its auxiliaries as per scope of work of Tender specification. (One Job means round the clock i.e. in all three shifts per day for one month)
1- For Anpara 210MW Unit-1
2- For Anpara 210MW Unit-2
3- For Anpara 210MW Unit-3
Overhauling of Centrifuging machine MAB103/206 as per scope of work.
Oil Flushing of H.P. Bypass oil system as per scope of work.
Transportation of lubricant/spares/consumables
Transportation of lubricant from Central Store to Site store.
Transportation of Empty Drums from site store to Central Store.
Running and up-keeping of 2 nos. portable centrifuging machine as per scope of work.
Replacement of the damaged L.P. diaphragms.
Cleaning of suction strainer of CEP
Cleaning of strainers of Raw Water Booster pumps
Round the clock up-keeping and maintenance of Boiler Feed Pumps and Condensate pumps as per Scope of work of tender Specification. .(One Job means round the clock i.e. in all three shifts per day for one month)
For Anpara 210MW Unit-1
For Anpara 210MW Unit-2
For Anpara 210MW Unit-3
Replacement of Old Turbine Oil cooler tube Nest Assembly with new one and installation and commissioning the same in unit#1/2/3 of 3x210 MW, ‘A’TPS, Anpara
Cleaning of Main oil tank room and spreading fresh sand (As per attached annexures)
Cleaning of Main Oil tank
Overhauling of gland seal vapour exhauster /Oil extraction fan
Replacement of damaged N2 gas bladder from Accumulator of HP Bypass system
Inspection / Replacement of HP Bypass Axial Piston Pump
Replacement of compensator of hotwell/ condensate Extraction pump
Cleaning of C.W. Duct inside the T.G. hall
Checking of through ness of drainpipe of Main Steam and hot reheat strainer
Repairing work of grating/chequred plate
Attending tube leakage of H. P. Heaters 5/6 of 3x210MW and commissioning of Heaters from water and steam side.
Attending water leakage from water box cover of H. P. Heaters 5/6.
Servicing of Pneumatically operated recirculation valves of BFP Nb 100mm
Servicing of solenoid operated drain valves DW-109 / DW-110
Servicing of motorized extraction valve ES-I / ES-4 Nb 200mm
Servicing of motorized Feed water discharge valves of BFP BF -7/8/9 of Nb200mm.
Servicing of H.P. motorized drain valve 25 to 50mm
Servicing of HP Manual valves & NRVs
Servicing of pneumatically operated drip line valve of LP heater, MC-23/19 ,DM-15 /16
Servicing of LP Hand operated/motorized valves at different elevations 25mm to 150mm.
Servicing of L.P. Hand operated/motorized valve/NRVs Nb 200mm to 500mm
Replacement of LP Valves (flange type) 100 to 500mm
Servicing of self-actuating feed water group protection valves FW-55/56 of H.P. Heaters of Nb-250mm and Np-250 Kg/cm².
Servicing of feed water motorized isolating valves of HP Heaters Nb 300mm.
Servicing & overhauling of Actuators K-150, F16A
Servicing of actuators type K-600, F14E
Servicing of pneumatic actuators
Servicing/Overhauling of Main Ejectors
Overhauling & Rectification of tube leakage from Turbine oil Coolers.
Overhauling/servicing of L. P. Heaters.
Servicing of drip control valves of H. P. Heater HD-20, HD-23, HD-14
Changing gaskets of flanges in feed line heaters, ejectors, Drain coolers etc.
Servicing of Actuators Limitorque/Siemens/ Acuma make
Replacement of HP valves steam line, oil line (motorized /hand operated) at different floors from (-) 4 meter to 11 meter level size more than Nb 15mm up to Nb 50mm
Replacement of HP valves steam line, oil line (motorized/hand operated) at different floors from (-) 4 meter to 11 meter level size more than Nb 50mm up to Nb 65mm
Replacement of HP valves steam line, drain line (motorized/hand operated) at different floors from (-) 4 meter to 11 meter level size more than Nb 65mm up to Nb 150mm
Replacement of gland packing of HP valves from Nb 50mm to Nb 500mm.
Replacement of gland packing of HP Bypass valve (BP-1 / BP-2).
Servicing of actuators of turbine gland seal steam /leak off controller along with valve.
Servicing of Electro hydraulically operated HP By pass valve (BP-1 / BP-2)
Attending leakages of pipeline & headers etc.of Turbine And It’s Auxiliaries by cutting grinding and H.P. welding of damaged portion putting new spools/bends if required.
Repair/Replacement of HP/LP Pipelines/drainlines by cutiing and re-welding on per mm basis
Inspection of Repaired TG Bearings No. 1 to 6: Dimension measurement and DP test
Performing condenser vacuum and tube leak test as per scope of work
M/S BIHAR CONSTRUCTION CO.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .