Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹95.7 LAccepted-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | 1 | Accepted-AOC Acceptance of tender | |
| 2 | 2₹1.2 Cr+₹22.2 L (23.2%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹1.3 Cr+₹30.4 L (31.8%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹1.3 Cr+₹31.3 L (32.7%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹1.4 Cr+₹44.2 L (46.2%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | 5 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | BHARAT ELECTRICAL TRADERS L4 | LUMOS INFRA PVT LTD L2 | Vijaypower Generators Limited L5 | Roy and Sons Infrastructures L1 | M/S S.B. Singh and Sons L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete. | 150 | Cum | 150 ₹22,500 | 180 ₹27,000 | 270 ₹40,500 | 250 ₹37,500 | 90 ₹13,500 Lowest |
| 2.00 | Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete. | 140 | Cum | 100 ₹14,000 | 180 ₹25,200 | 21 ₹2,940 Lowest | 60 ₹8,400 | 50 ₹7,000 |
| 3.00 | Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete. | 10 | Cum | 50 ₹500 | 270 ₹2,700 | 21 ₹210 Lowest | 70 ₹700 | 50 ₹500 |
| 4.00 | Supplying and making indoor cable end terminations with heat shrinkable jointing kit including all accessories & lugs suitable for 11 KV (earthed) 3 core 95 sqmm XLPE aluminium conductor cable as required. | 11 | Each | 3,500 ₹38,500 | 6,930 ₹76,230 | 4,790 ₹52,690 | 4,900 ₹53,900 | 3,000 ₹33,000 Lowest |
| 5.00Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade PVC insulated PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of following nominal cross sectional area:- | ||||||||
| 6.00 | (a) 95 sqmm 3.5 core | 100 | RM | 820 ₹82,000 | 774 ₹77,400 | 846 ₹84,600 | 612 ₹61,200 | 590 ₹59,000 Lowest |
| 7.00 | (b) 240 sqmm 3.5 core | 100 | RM | 1,950 ₹1,95,000 | 1,836 ₹1,83,600 | 1,911 ₹1,91,100 | 1,500 ₹1,50,000 | 1,060 ₹1,06,000 Lowest |
| 8.00 | Supplying, laying, testing and commissioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 6.35 KV(UE)/11 KV(E) of size 95 sqmm 3 core complete. | 300 | RM | 1,150 ₹3,45,000 | 1,260 ₹3,78,000 | 1,311 ₹3,93,300 | 985 ₹2,95,500 | 900 ₹2,70,000 Lowest |
| 9.00 | M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm upto 7.5 m by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I (2009) and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work as required. | 10 | Each | 5,500 ₹55,000 | 6,030 ₹60,300 | 6,000 ₹60,000 | 9,000 ₹90,000 | 4,900 ₹49,000 Lowest |
| 10.00S&F DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc ISI marked as per IS-16205 (Part-24) including cutting/ jointing laid in trenches, wall, floor etc as required for the following nominal sizes:- | ||||||||
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
13 Mar 2026, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
AUGMENTATION/ UPGRADATION OF TRANSFORMERS AND ALLIED WORKS AT CH (CC) AND CMDC UNDER GE E/M LUCKNOW
2026_MES_747736_2
CWE/LKO/EM/T-113 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM LUCKNOW
₹2.4 L
Yes
22 May 2026
27 Feb 2026
16 Mar 2026
27 Feb 2026
13 Mar 2026
6 Mar 2026
27 Feb 2026 - 6 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete. | 150 | Cum | - | - |
| 2 | Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete. | 140 | Cum | - | - |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete. | 10 | Cum | - | - |
| 4 | Supplying and making indoor cable end terminations with heat shrinkable jointing kit including all accessories & lugs suitable for 11 KV (earthed) 3 core 95 sqmm XLPE aluminium conductor cable as required. | 11 | Each | - | - |
| 5 | Supplying, laying or fixing or passing through pipe, testing and commissioning 1100 volts grade PVC insulated PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of following nominal cross sectional area:- | - | - | - | - |
| 6 | (a) 95 sqmm 3.5 core | 100 | RM | - | - |
| 7 | (b) 240 sqmm 3.5 core | 100 | RM | - | - |
| 8 | Supplying, laying, testing and commissioning XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 6.35 KV(UE)/11 KV(E) of size 95 sqmm 3 core complete. | 300 | RM | - | - |
| 9 | M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth strip 32 x 6 mm upto 7.5 m by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES SSR Part-I (2009) and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work as required. | 10 | Each | - | - |
| 10 | S&F DWC HDPE pipe ISI marked alongwith all accessories like socket, bend, couplers etc ISI marked as per IS-16205 (Part-24) including cutting/ jointing laid in trenches, wall, floor etc as required for the following nominal sizes:- | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
TenderEMT113.pdf
Tender Documents • 0.67 MB
BOQ_845124.xls
BOQ • 5.40 MB
Amdt_dt_31Mar.pdf
PDF • 0.11 MB
Criticaldate3.pdf
PDF • 0.12 MB
Criticaldate2.pdf
PDF • 0.27 MB
Criticaldate2.pdf
PDF • 0.12 MB
CorrigendumTender2.pdf
PDF • 0.06 MB
Corrgtender.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .