Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹21.4 L+₹2.3 L (11.9%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NAL
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_493380_1
GE (AF) NAL/T-43/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) NAL BIKANER
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) NAL
₹40,000
Yes
GE (AF) NAL
26 Feb 2022
9 Dec 2021
13 Jan 2022
9 Dec 2021
11 Jan 2022
23 Dec 2021
9 Dec 2021 - 20 Dec 2021
21 Dec 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Supply & Laying bricks using sub class ‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cable perpendicular to direction of cable, complete all as specified and directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor 2 core 10 sqmm from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
All as per description of serial item No. 6.00 here in before but size of cable 4 core 16 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 25 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 35 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 50 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 95 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3.5 core 120 Sqmm
All as per description of serial item No. 6.00 here in before but size of cable 3 core 95 Sqmm, 11000 volts grade
All as per description of serial item No. 6.00 here in before but size of cable 3 core 185 Sqmm, 11000 volts grade
Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed.
All as per description of serial item No. 15.00 here in before but size of cable 4 core 16 Sqmm
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 25 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 35 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 50 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 95 Sqmm.
All as per description of serial item No. 15.00 here in before but size of cable 3.5 core 120 Sqmm.
All as per description of serial item No. 15.00 here in before but 11 KV HT cable of size 95 sqmm 3 core
All as per description of serial item No. 15.00 here in before but 11 KV HT cable of size 185 sqmm 3 core
Dismantling insulators any type, any size from its original position and removing from site complete all as specified and directed.
S&F pin type porcelain vitreous white or brown insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade fixed on poles/cross arms of upto 9 m long complete all as specified.
All as per description of serial item No. 25.00 here in before but 150mm height, 150mm dia for 11000 volts grade.
S&F shackle type porcelain vitreous white/brown or green insulator incl galvanised mild steel straps, washers, insulator bolts, washers and nuts for working pressure 1100 volt section of strips 31x5 mm bolt dia 14 mm max dia 115 mm, height 100 mm fixed on poles/cross arms of upto 9 m long, complete all as specified.
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed.
Material and Labour boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
Dismantling and taking out the old stay assembly complete incl demolition of plain cement complete all as specified and directed. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. (ii) Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 16 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
Dismantling and taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 400/200 Amps complete all as specified and directed.
Supplying and fixing installing, commissioning and testing HT 11KV, 3 phase system, outdoor type gang operated switch, air break type suitable for vertical mounting complete with necessary insulators and separators, set of drop out fuses (12 insulators) and operating handle of GI pipe 25 mm dia, medium grade rod of suitable length (mechanically operating arrangements), locking arrangement with lock and two keys complete of rating 400 Amp complete all as specifiedand directed.
All as per description of serial item No. 33.00 here in before but Horizontally operated without dropout fuses (9 insulator).
S&F as in repairs drop out fuse assembly complete set with Insulator-06 Nos and connected accessories for 11000 V grade with suitable size of drop out fuses incl taking down old assembly complete all as specified and directed.
Material and labour two coats of silver / aluminium paint on steel tubular LT pole including on MS work like channel cross arms, nut, bolts & washer, street light bracket and clamps above 1.50 metre from top of PCC coping and two coats of synthetic enamel paint in alternative black and white strips of 30 cm each upto 1.50metre from top of PCC coping including scrapping the existing paint and the preparation of surfaces complete all as specified and directed. Note : Unit rate of this item includes the following : - (i) Painting shall be done on existing surface except strip portion at bottom of 1.5 mtr height. (ii) All MS work shall also be painted.
All as per description of serial item No. 36.00 here in before but on two pole structure with HT poles and strips in red and white colour
All as per description of serial item No. 36.00 here in before but on four pole structure with HT poles and strips in red and white colour
Material and Labour removing old stone aggregate any size from 4 pole structures and supply & laying new stone aggregate 40mm size including making good the existing surface upto 15cm depth complete all as spefied and directed. Note : Before laying new stone, existing area shall be neatly cleaned and existing bushes, grass etc shall be removed and thrown away as directed.The quoted rate shall include the cost thereof
Taking down/removing all connections of four pole structure incl all jumpers and complete rejumpering using new ACSR connectors of adequate length through insulated pipes and connections using aluminium lugs/sleeves of directed sizes and treating with conducting jelly and testing of structure before charging with electric supply all to the satisfaction of Engr in charge.
S&F in repairs Mild steel work in framed work such as grills, Gates, Framed guard bars, gratings, ladders, Cable trays, Fencing etc., with ends of bars soldered/welded and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 E-165 incl two coats of mettallic paint over a coat of mettallc primer complete all as specified and directed.
S&F as in repairs lightning Arrestor Expulsion type Transmission Class 65 Kilo Amps 11000 V Grade incl connecting complete all as specified and directed.
Shifting of Transformers upto 300KVA from one substation to other substation in the case of any breakdowns by using man power and mechanical means after disconnecting all electric connections and reconnecting in new locations within 263 SU area as directed. Note : (i) Contractor shall provide all the T& P including transportation for shift and nothing extra shall be paid on account of loss of manpower during shift. Tenderer is hereby advised to keep in mind this factor before quoting his rates.
Supply and fix as in repairs GI strip 32mm x 6mm burried in ground / laid in floor / fixed to wall on saddles / on porcelain insulators etc complete all as specified and directed. Note : Excavation and earthwork shall be measured and paid for separately.
Material and labour as in repairs earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 3.00 mtr deep below ground level with top edge of the earth plate at depth not less than 2.25 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I).
Supply and fixing as in repairs MCCB of 63 Amps , 4 pole, 415 volts, 50 Hz, rupturing capacity 16 KA, connection with proper size of thimbles complete all as specified and directed.
All as per description of serial item No. 46.00 here in before but 100 Amps, 16 KA
Supply and fix as in repairs MCCB, 125A, rupturing capacity 16 KA , 415 volts 4 pole complete all as specified & directed.
Supply and fix as in repairs MCCB, 160A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fix as in repairs MCCB, 200A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fix as in repairs MCCB, 250A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply and fix as in repairs MCCB, 400A, rupturing capacity 36 KA, 415 volts 4 pole complete all as specified & directed.
Supply, install, testing and commissioning as in repair outdoor type factory made, made out of 3.15mm thick CRCA Sheet CPRI test certified, platform mounted LT panel board to accomodate the following items and built upon angle iron frame suitable size compartmentalized design work, duly powder coated with gray paint and suitable size of cable glands chromium plated and Aluminium busbars TPN, 200 Amps,415 V,50 Hz complete as following :- (i) MCCB 63 Amps, 3 Poles, 25 KA rupturing capacity - 01 No (Outgoing) (ii) Indicating lamp LED RYB set of three with colour codeing - 1 No. Note : Unit rate of this item also includes the following :- (i) Panel shall be fixed as per existing manner and where the excavation and earthwork involved shall be carried out by the contractor as directed. (ii) After errection / fixing of panels, all connection shall be made by the contractor as directed. (iii) The existing surface shall be made good by the contractor to the entire satisfaction of Engineer-in Charge.
M&L trimming of tree branches on both sides of LT aluminium conductor overhead complete all as specified and directed. Note : (i) Cutting branches shall be dumped outside the air force premises. (ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account. (iii) Before commencement of trimming work, elctric shutt down shall be got managed by the contractor and sufficient man power shall be deployed on the particular time so that the task given by the Engineer-in-Charge shall be completetd with the time allowed. (iv) A pair of aluminium conductor and GI earth wire of any number shall be considered one RM for payment purpose.
Supplying and laying as in repairs 80mm bore GI tubing medium grade incl all accessories for pssing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. (MS works including painting will be measured under seperate item in Schedule)
All as per description of serial item No. 55.00 here in before but 50 mm bore
S&F as in repairs cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size 35 to 50 Sqmm 3.5 core complete all as specified and directed.
S&F as in repairs cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size 70 to120 Sqmm 3.5 core complete all as specified and directed.
S&F as in repairs cable jointing kit straight through heat shrinkable type complete with jointing materials suitable for LT Armoured cables of size 150 to 185 Sqmm 3.5 core complete all as specified and directed.
Re-stretching the existing LT/HT over head line consisting of 5/4/3 conductors of any size and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulator properly with the help of binding wire 14 SWG and re-fixing separators in its original position complete all as specified and directed. Note: (i) Each run of conductor/wire shall be measured and paid separately (ii) Length of conductor shall be taken between the poles and no sagging element shall be accounted for payment purpose. This aspect shall be kept in mind while quoting the rate
Disconnection of Transformer from HT/LT side at site, dehydration and filtration of the transformer oil with the help of oil filtration plant of any capacity of distribution transformer indoor/outdoor type 11/0.433 KV. Notes:- a) The unit of payment under this item shall be for the oil required for all process to entire completion of the job. b) New oil required for topping up before dehydration & filtration shall be measured and paid separately under relevant item. c) The dielectric strength of oil shall not be less than 45 KV when maintained a gap of 3mm for one minute all as specified and directed. d) All T & P required for dehydration shall be arranged by the contractor at his own. e) Additional transformer oil required for top up shall be measured and paid for separately as 'Supply Only' under respective item of this Schedule.
Supply and filling new transformer oil of superior quality conforming to IS 335:93 complete all as specified and directed. Note:- (i) The dielectric strength of oil should not be less than 60 KV when maintained a gap of 3mm for one minute complete all as specified and directed. (ii) Contractor shall bring the transformer oil in sealed container and after use of oil, container shall be property of contractor and nothing extra shall be admissible on this account..
Supply and fixing as in repairs LT bushing assembly complete with insulator, brass stud rod, nuts, washers, gasket etc complete with accessories suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V complete all as specified and directed.
All as per description of serial item No. 63.00 here in before but HT bushing.
Supply and fixing as in repair oil drain valve cast copper alloy any dia suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
Supply and fixing as in repair 6mm thick cork sheet set (Rubberized cork /neoprene) for top cover suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed. Note:- Size of sheet shall be as per existing cover. Hence, no claim whatsoever shall be entertained by the Deptt for any misunderstanding.
Supply and fixing in replacement breather assembly complete set suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V of existing make complete all as specified and directed.
Supply and replacement silica gel complete all as specified and directed.
Material and labour Spray painting to outer surfaces of transformer upto 630 KVA transformer 11KV / 433V with two coats of synthetic enamel paint after scraping, removing, washing and cleaning of old paint, complete all as specified and directed.
Supply and fixing as in repairs temperature gauge suitable for upto 630 KVA transformer indoor/outdoor 11KV / 433V as existing make complete all as specified and directed. Make : Feibig / H Guru / Anergy Note : _ These transformer are located /fixed at different location and of different sizes, tenderer are hereby advised to see this aspect before quoting their rates and no claim what soever shall be entertained by the department on account any misunderstanding.
S&F as in repair heavy duty double break fuse switch HBC/HRC fuse type TPN 415 Volts 200 amps capacity with 03 Nos HBC fuse link complete all as specified and as directed. Make : HAVELLS/BRITE/STANDARD/L&T
Supply & fixing as in repair cable jointing kit for 11 KV (E) grade for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable upto 120 Sqmm 3 core XLPE cable armoured aluminium conductor complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of the existing joint.
All as per description of serial item No. 72.00 here in before but of size 95 sqmm 3 core
All as per description of serial item No. 72.00 here in before but outdoor type of size 185 sqmm 3 core
All as per description of serial item No. 72.00 here in before but outdoor type of size 120 sqmm 3 core
All as per description of serial item No. 72.00 here in before but outdoor type of size 95 sqmm 3 core
Supply, jointing & testing as in repairs cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm complete all as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement of existing joint.
Supply, jointing & testing straight through joint (E) heat shrinkable type suitable for XLPE HT cable of size 120 Sqmm 3 core, 11000 volts grade complete as specified and directed. Note : Unit rate of this item also includes the cost of excavation and earthwork though required for replacement the existing joint.
All as per description of serial item No. 78.00 here in before but of size 185 sqmm 3 core
Dismantling of cross arms, supports, clamps and back plates incl nut bolts washers, any shape or size as indicated complete all as directed. Note : (i) Existing MS work is of different sizes and fixed at different locations. While dismantling, ACSR conductor shall be loosened properly as per direction of Engr-in-Charge (ii) The contractor shall submit his schedule for dismantling / taking down at least one week before undertaking the work of dismantling ACSR conductor so that the shut down of lecricity can be managed accordingly. (ii) T & P required for dismantling shall be arranged by the contractor at his own cost.
M&L mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from steel section, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. Note : Nuts, bolts, washers shall be measured and paid separately.
S&F PVC line seperator for separating 3 / 4 / 5 LT overhead lines complete all as specified and directed. Note : The length of PVC line separator may be varied hence size of separator shall be as per site requirement, however no claim whatsoever shall be entertained by the Deptt. on this account.
M&L detecting / locating fault of HT 11KV UG cable of size 95 to 185 Sqmm using pin point fault locator machine complete all as specified and directed Note : (i) Straight through/cable end joints are measured and paid separately. (ii) Fault locating machine shall be arranged by the contractor at his own. Therefore, the contractor shall keep this aspect in mind while quoting the rates. Nothing shall be admissible for any misunderstanding on this account.
Dismantling of damaged steel tubular/PCC pole of size 9 mtr for disposal all as specified and as directed. Note : (i) Dismantling of existing pole shall be undertaken only after removal of ACSR conductor, MS Work & insulators etc which shall be measured and paid for separately under respective item of this Schedule. (ii) Unit rate of this item includes the cost of dismantling of PCC and excavation and earthwork complete as directed.
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-31, 9 meters long L.T pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting with two coats of aluminium paint over a coat of primer incl marking pole number with paint, Excavation and in any type of strata 1.50metre deep, PCC 1:3:6 foundation / filling upto GL and PCC 1:2:4 coping of size 600mm x 600mm, 300mm deep above GL, complete all as specified and directed Note : Unit rates of this item includes the cost of PCC in foundation, PCC coping and excavation & earthwork
M&L preparation of surfaces of HT PCC pole upto 1.5mtr height from coping and painting with two coats of synthetic enamel paint in alternative red and white strips of 30cm each and writing pole numbers with black paint complete all as specified and directed.
M&L preparation of surfaces of LT PCC pole upto 1.5mtr height from coping and painting with two coats of synthetic enamel paint in alternative black and white strips of 30cm each and writing pole numbers with black paint complete all as specified and directed.
Taking out operating handle with clamps from the GOD switch 200 Amps to carry out repairs by cutting the operating rod to the required length and refixing the GOD switch along with handle and new clamp all as required for smooth operation of GOD switch.
M&L as in repairs 40mm thick, 2nd class hardwood planks, n exc. 25 cm in width and fixing on angle iron frame of 2/4 pole structure, screwing with existing iron structure complete suitable length laying adjust one by one including one coat of paint over a coat of pink primer complete all as specified. Note : Width and langth of plank shall be as per existing or as directed.
Taking out the damaged / low earth result earthpits and carry out necessary repairs and refilling the charcoal dust, salt and chemical compound as mentioned below :- a) Removing the earthpit cover/earthstrip connections from test point b) Digging the earthpit ranging from 4 feet to 10 feet using 80mm bore pipe as required according to the condition of soil in earthpit c) Filling the earthpit initially with earth enhancing compound and chemically treated earth booster. d) Filling the earthpit by earth compatible charcoal and salt e) Lastly watering the earth pit f) Covering the earth pit with existing covers and testing the earthpit resistance value and connecting the earth strip in its original position. Note : Materials required for replacement shall be measured and paid separately under relevant item as supply
Supply only Earth compatible Charcoal best quality
Supply only Mineral Salt
Supply only Chemically treated earth booster
Dismantling/taking down old unserviceable ACSR conductor of any size from LT / HTpoles over head electric line after disconnecting from insulators complete all as specified and directed.
Supply and stringing PVC insulated aluminium conductor steel reinforced (ACSR) stretching properly to achieve proper sag on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc complete all as specified and directed.
Supply and fix heavy duty power shunt capacitor 440v 3 phase 50HZ of type cylinder/box complete all as specified and directed.
Supply and fix Power contractor 440V, 3 phase, 50 HZ suitable 5 KVAR Rating complete all as specified and directed.
All as per description of serial item No. 97.00 here in before but 8.5/10 KVAR Rating
All as per description of serial item No. 97.00 here in before but 15 KVAR Rating
All as per description of serial item No. 97.00 here in before but 20 KVAR Rating
Disconnecting the HT 11 KV supply from VCB SF 6 unit existing in P-40 Incoming Substation, removing the top cover of VCB for carrying out complete servicing of incoming and outgoing feeders (two incoming feeders and three outgoing feeders) completely by air blower and removing the dust deposited over all mechanical parts, oiling, greasing the mechanical moving parts and replacement of any worn out parts, gas and testing the VCB for smooth operations. Caliberation of multi-functional relays, for over current and earth fault and resetting the same as per load on the feeders. Note : Spares / parts shall be measured and paid separately as 'supply only' under relevant items of this schedule . Make of VCB : ABB)
Disconnecting the LT 1100V supply from ACB unit existing in Panel, removing the top cover of ACB for carrying out complete servicing of incoming and outgoing feeders completely by cleaning with air blower and removing the dust deposited over all mechanical parts, oiling, greasing the mechanical moving parts and replacement of any worn out parts and testing the ACB for smooth operations, caliberation of relays, for over current and earth fault and resetting the same as per load on the feeders. Note : Spare parts will be measured and paid for separately under relevant items of schedule)
Supply only SF6 gas for filling in VCB complete all as specified and directed.
Supply only Motor for operating breakers for VCB SF 6 as per sample existing at site complete all as specified and directed.
Supply only Digital Meter showing the Ampere, Voltage power factor etc for VCB SF 6 complete all as specified and directed.
Supply only multi-functional relay 24/240V AC/DC volt for VCB SF 6 complete all as specified and directed.
Supply only spring charging motor, 220V, AC/DC supply for ACB complete all as specified and directed.
Supply only vertical terminals 800 / 1000 & 630-1250S1 (adopters) for ACB complete all as specified and directed.
Supply only jaw contact assembly 630-1250S1 for ACB complete all as specified and directed.
Supply only pole assembly 630-1250S1 for ACB complete all as specified and directed.
Supply only shunt release EA1, 415V, AC for ACB complete all as specified and directed.
Supply only closing preventer, 415V, AC for ACB complete all as specified and directed.
M&L easing and adusting loose door shutter of LT panels including replacement of old rusted hinges by welding complete all as specified and directed. Note:- Cost for use of Welding machine is included in unit quoted rate.
M&L for painting with two coat of synthetic enamel paint of Surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed
Material and Labour in repair for earthing complete with copper plate electrode 60 cm x 60 cm x 3.15 mm thick, buried directly in ground, vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at depth not less than 1.5 meter below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 mm x 3 mm by means of bolts, nuts, check-nuts and washers of galvanised iron and then brazing the copper strip joints and thimbles of earth wire and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I) and colour coding the earthing including taking out the old unserviceable earth plate complete all as specified and as directed. Note : (i) Copper strip fixed more than 2 meters will measured and paid separately. (ii) Colour coding of earthing to be indicated on cover of earth plate by painting according to the type of earth plate all as specified and as directed. (iii) Earth value to be measured and necessary resistance value to be brought down below 1 ohm. (iv) Marking of the earth pit should have the type of earthing, no of the earth pit and the total number of particular type of earthing for that bldg/equipment. for eg:- a lightening earth pit can be marked as LA-1/4 which means lightening arrestor earth pit No 1 out of total 4 LA earth pits for the bldg equipments.
Material and Labour in repair for copper strip of size 20 mm x 3 mm of any type, complete all as specified and as directed
Supply and fixing as in repair ON LOAD change over switch 415V ,50 Hz 4 pole of capacity 200 Amps complete all as specified and directed.
Labour for uploading and opening of transformer of capacity 200 KVA, 11/0.433 KV cover , draining of oil,detanking of core and coil assembly , cleaning and washing dust/rust and dirt from all parts including core tank and cooling tubes , painting inside with two coat of zinc chromate and outside with gray paint complete all as specified and directed.
Material and labour rewinding for HV legs copper coils with insulation varnishing and baking of coil assembly for transformer of capacity 200KVA 11/0.433KV copper wound complete all as specified and as directed.
Material and labour rewinding for LV legs copper coils with insulation varnishing and baking of coil assembly for transformer of capacity 200KVA 11/0.433KV copper wound complete all as specified and as directed.
S&F Anodised aluminium snap grid frame work for false ceiling complete all as specified and directed.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L for 8mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed.
M&L for shifting of split AC 1.5/ 2.0 TR with indoor and outdoor unit and refixing the same in new position and testing up to the satisfaction of Engr-in-charge complete all as specified and directed.
Supply and Fixing white powder coated aluminium extruded housing worth LED having super slim design for suspended mounting energy efficient LED 2 x 2 recess mounting fitting complete with electrical connections with following features :- (i) Slimmest (9mm thick) in class LED ceiling panel with best in class asthetics. (ii) Premium white powder coated frame blends seamlessly with ceiling layout. (iii) Suitable for 600 x 600 mm modular ceiling grid and also be suspended with provided kit Make : CG Cat part No ; LCPL- 36-CDL (2 x 2) equivalent in Philips / Syska
Demolition of cement concrete unreinforced in (below or above ground level) ground floors and paving n exc 15cm thickness complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) for sub bases of floor,foundation filling, mass concrete complete all as specified and directed.
Supply and fixing precast cement concrete 1:2:4 type B-0 (using 12.5 graded crushed stone aggregate) as in louvres and jallies(design pattern of jallies and louvers as approved by Engr-in-charge), 25mm thick including all necessary mould- ings,frame and fittings etc and set in CM 1:4 complete all as specified and directed.
Demolition of brick or stone masonary built in cement mortar incl all quoins, arches, pillar etc. complete all as specified and directed.
Material and labour for brick work with sub class ‘B’ bricks of class designation 7.5 all as per IS-1077-1992 (minimum compressive strength of brick 75 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
All as per description of serial item No. 130.00 here in before but in half brick
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces including finishing even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls applying two coats of apex paint in plain pattern (tint as approved by engr-in-charge) over priming on plastered and other surfaces with alkali resistent primer complete all as directed and specified.
M&L for PCC 1:2:4 type B-0 (using 12.5 graded crushed stone aggregate) as in copings,kneelrs bed plates kerbs, water troughs and like including weathering slightly rounded or champhered in edges including all necessary form work finished smooth without using extra cement complete all as specified and directed.
M&L for Cutting chases, pinning in brick walls, concrete block or slab walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 20 cm girth complete all as specified and directed.
M&L for rendering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls applying two coats of apex paint in plain/camauflage pattern over priming on plastered and other surfaces with alkali resistent primer complete all as specified and directed.
M&L for factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottam rail . paneling of plain colour PVC sheets to be filted in MS frame welded, sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with the solvent cement complete all as specified and directed.
Supply and fixing in opening solid PVC door frame of size 50mm x 47mm made out 5mm plain colour PVC sheets re-inforced with MS square tube complete all as specified and directed.
M&L for Plain fillets exc 3 sqcm but n exc 6 sqcm square,rectangular or triangular in section, clean sawn, secured with nails or brads as in timber framework in walls for panelling work complete all as specified and directed
Supply and fixing Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified and directed.
M&L for Framed work such as grills, grating etc with ends of bars shouldered and or riveted or forged in to spikes;framed guard bars;barreled iron door ;ladders ;frame baulsters; walkways; railings; framework of water tanks and similar work , drilled and countersunk for screw, including necessary bolts,screws, washers along with bending and welding angles, as necessary, gusset plates, riveting ,fastners, etc.conforming to Fe.290.Gde-E-165 complete as specified and directed.
M&L for Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement concrete 1:2:4 type B-1 as required depth of embedded portion exc half brick but not exceeding one brick complete all as specified and directed.
M&L for Mild steel plain black sheet of thickness not less than 0.80 mm in steel gates,covering to door shutters and similar work, cut to size, holespunched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed.
S&F pre-painted galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with machine self taping screws complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Surface excavation of soft loose soil n.exc 30cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
M&L for Hardcore of gauge n.exc 63mm broken stone or boulders deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) for sub base of floor complete all as specified and directed.
M&L for 25mm thick a layer of sand laid over PCC and fully compacted by watering and providing gradient complete all as specified and directed.
M&L for 80 mm thick machine pressed precast concrete interlocking paver block any shape and size comfirming to IS 15658-2006 M-40 grade with grey cement complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) in copings,kneelrs.bed plates kerbs, water troughs and like including weathering slightly rounded or champhered in edges including all necessary form work complete all as specified and directed.
S&F air circulator fan 230 volts single phase oscillating 450mm sweep suitable for wall mounting complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars,posts for antenna base, boundary pillars and posts (including caps and bases) including all necessary formwork required complete all as specified and directed.
M&L rendering 15mm in cement mortar 1:4 on fair faces of brick / concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L Preparation of newly plastered surfaces of walls applying two coats of apex paint in camauflage pattern over priming on plastered and other surfaces with alkali resistent primer complete all as specified and directed.
Supply and fixing/ instalation anti bird net, Square mesh size 20 mm x 20mm, Black/ White HDPE knotted Net, Thickness of the net 1.00mm, Weatherproof, U.V. stabilized and chemically inert, Breaking strength of 23.08 kg per yarn, Having a Melting point of 260 c fixed with border rope of dia 04mm, UV stabilized border rope jointed with the net by machine inter locking process using three twinces of the same as that of net tied to 12mm dia Hooks (made to shape) or welded to steel structure and 12 mm dia ancher fastner bolt fixed to RCC structure as applicable at suitable intervals complete all as specified and directed.
Supply and laying galvanised steel tubing, medium grade, 50 mm bore laid in trenches / floors or fixed to walls including required GI specials / fittings complete all as specified and directed.
S&F Gun Metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50mm bore complete all as specified and directed.
Material and Labour boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
BIDAWAT ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .