Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 CrAccepted-AOC | ₹18.2 Cr Quoted ₹20.4 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹20.6 CrRejected-Finance | ₹20.6 Cr | L2 | Rejected-Finance Second Least Quoted |
Tender Value
₹18.2 Cr
EMD Value
₹28.2 L
Closing Date
17 Aug 2022, 4:00 pmClosed
Chief Executive Officer,PSCDL
No.2, Bussy Street, Old Court Building, Puducherry
Development of Housing and Livelihood Infrastructure in Low Income Settlements in Puducherry
2022_PSCDL_10775_1
027/PSCDL/CITIIS/PCK1/2022-23
Open Tender
Civil Works
545 days
PSCDL
Please Refer Tender Documents
3 documents required · 3 mandatory
₹15,750
₹28.2 L
PSCDL,Puducherry
30 Sept 2022
1 Aug 2022
17 Aug 2022
1 Aug 2022
17 Aug 2022
8 Aug 2022
3 Aug 2022
Amount
CODE NO: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil.
CODE NO: 2.26.1 Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil.
CODE NO: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
CODE NO: 2.27A.1 Supplying and filling with gravel ( excluding rock) in renches,plinth,sides of foundation etc. In layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc. complete including all lead and lift.
Code No: NPSR-1 Supplying and filling in plinth with M sand under floors including, watering, ramming consolidating and dressing complete
CODE NO: 4.1.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 5.33.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of entering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable. - All work upto plinth level
CODE NO: 5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
CODE NO: 5.22.10 Providing and placing M30 grade cover block for RCC work all levels
CODE NO: 5.8 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers , facias and eaves boards upto floor five level excluding the cost of centering , shuttering , finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
CODE NO: 5.34.1 Extra for providing richer mixes at all floor levels - Note:- Excess/ less cement over the specified cement content used is payable / recoverable separately - Providing M-30 grade concrete instead of M-25 grade BMC / RMC . (Note:- cement content considered in M-30 is @ 340 kg /cum)
CODE NO: 5.9.1 Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns,etc. for mass concrete.
CODE NO: 5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings , balconies and access platform
CODE NO: 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
CODE NO: 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for: columns, pillars, piers, abutments, posts and struts.
CODE NO: 5.9.7 Centring and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral - staircases
CODE NO: 5.16 Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size)
CODE NO: 5.18.1 Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick
CODE NO: 5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
CODE NO: 5.22A.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
CODE NO: 5.9.19 Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc.,including edges.
CODE NO: 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.4.1 Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand)
CODE NO: 6.47 AAC block work 230mm Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300mm thick AAC blocks in super structure above plinth level upto floor V level with RCC band with sill level and lintel level with approved block laying polymer modified adhesive mortar all complete. ( The payment of RCC band and reinforcement shall be made for separately)
CODE NO: 9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood.
CODE NO: 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
CODE NO: 9.48.1 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S.flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
CODE NO: 9.53 Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 9.96.1 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc.complete:- 1200 X 1200mm
CODE NO: 9.97.1 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete : - 300x10mm
CODE NO: 9.100.1 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete :-125mm
CODE NO: 9.118.1 Providing and fixing to existing door frames -- 24mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt edging on both sides . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws . The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of 'H' section , a uPVC hollow ection of size 100 x 24 mm and 2 mm (+-0.2 mm) wall thickness , fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers, complete as per manufacturer's specification (For W.C. and bathroom door)
CODE NO: 9.165.1A Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
CODE NO: 10.25.2 Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
CODE NO: 10.11.1 Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators , side /top/centre hung, with beading and all members such as F7D,F4B,K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings , complete all as per approved design, (sectional weight of only steel members shall be measured for payment) - Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 11.40.1 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 11.40.2 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete Providing and laying rectified ceramic sqm 1,001.26 rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the maufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 11.36C Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours , shades of size 300 x 600 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size 300x600 mm
CODE NO: 12.15.1 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sq.m impregnated with a coat of coarse sand at 60cudm per 10 sq.m including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete - with residual type petroleum bitumen of grade VG-10
CODE NO: 12.20 Providing and laying pressed clay tiles (as per approved pattern18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
CODE NO: 10.17 Providing and fixing M.S. fan clamp type I or II of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C.slabs or beams during laying , including painting the exposed portion of loop, all as per standard design complete
CODE NO: 12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
CODE NO: 13.8.2 15 mm cement plaster on rough side of single or halfbrick wall finished with a floating coat of neat cement of mix - 1:4 (1 cement: 4 fine sand)
CODE NO: 13.1.2 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
CODE NO: 13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
CODE NO: 13.7.1 12mm cement plaster finished with a floating coat of neat cement of mix - 1:3 (1 cement :3 fine sand)
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 12.75 Providing and laying water proofing for roof portion - Clean the surface using wire brush to remove fungus sticking on the tilesurface. Remove the laitance and plaster residues with a chisel & hammer and repair any broken structure with civil work . Apply one coat MACRYL SL (Acrylic penetrating primer) Lay one coat of 3-4 mm thick MATPROOF ACR (Fibre reinforcedAcrylic plaster) Elastomeric plaster on the flat area . Provide a seal coat with a flexible MACRYL again
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
CODE NO: 13.29.1 18mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand)- Flush Band.
CODE NO: 13.37.1 White washing with lime to give on even shade - New work (three or more coats).
CODE NO: 13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
CODE NO: 13.48.3 Painting steel work with deluxe multisurface paint to give an even shade. Two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @ 0.80 ltr / 10 sqm of approved brand and manufacture
CODE NO: 13.50.1 Applying priming coat - with ready mixed pink pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
CODE NO: 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
CODE NO: 7996 Factory made EPS light weight composite sandwitched wall/roof panel (50mm thick) having core material of EPS granule balls/beads (conforming to IS 4671: 1984 and shall have density not less than 15 kg per cum). The outer face on both sides of the panels will be non asbestos fiber cement board confirming to IS 14862:2000 or calcium silicate board confirming to EN 14306:2009 of 5mm thick each.
CODE NO: 4.1.3 50MM Screed Concrete Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
CODE NO: 4.2.3 Constructions of granular sub-base by providing coarse graded meteraial, spreading in uniform layer with motor grader on prepatred surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density complete as per clause 401 of MoRTH specification, 4th Revision for grading III material.
CODE NO: 10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks , mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to ISS :4454 -part 1 and M.S.top cover of required thickness for rolling shutters - 80 x 1.25mm M.S.laths with 1.25 mm thick top cover
CODE NO: 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and appproved size and design /shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with coarse sand etc. all complete.
CODE NO: 18.48A Providing and placing on terrace(at all floor levels)polyethylene water storage tank ISI:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. for domestic water-Circular Tank (3000 litre Tank 22nos)
CODE NO: 18.62.3 Providing and fixing PTMT Ball cock of approvedquality colour and make complete with Epoxy coatd aliminium rod with L.P / H.P.H.D.plastic ball-25mm nominal bore, 152mm long,weighing not less than 440 gms.
CODE NO:18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50mm nominal bore
CODE NO:18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete-25mm nominal bore
CODE NO:18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall )-20mm nominal outer dia pipes
CODE NO:18.9.12 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
CODE NO:18.9.14 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 40mm nominal outer dia pipes
CODE NO : NPSR-2 Providing, fixing, testing and commissioning of PVC multi inlet floor trap / p trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 110mm dia inlet 75mm dia out let - Floor Trap
CODE NO:19.33.1 Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes (type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter.
CODE NO:19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
CODE NO:19.33.1E Providing and fixing on wall face/column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion-heel rest bend 110mm.
CODE NO:19.33.2 Providing and fixing on wall/column face unplasticised-PVC soil and waste pipes(type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
CODE NO:19.33.2A Providing and fixing on wall/column face unplasticisd-PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm
CODE NO:19.33.2F Providing and fixing on wall face/column face unplasticised - PVC moulded fittings /accessories for unplasticised PVC soil and waste pipes conforming to IS:4985 including of jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - bend with door 75 mm.
CODE NO:12.43.1 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete 75mm
CODE NO:12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete 110mm
CODE NO:17.10.2.3 Providing and fixing Stainless steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I.brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required - kitchen sink without drain board -470x420 mm bowl depth 178mm
CODE NO:17.28.2.2 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete - Flexible pipe - 40mm dia
CODE NO:17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm
CODE NO:17.18.2 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -coloured
CODE NO:17.20.2 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete - black solid plastic seat with lid
CODE NO:17.25.3 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings -angleback wash basin of size 600x480mm
CODE NO:18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
CODE NO:NPSR-3 Providing, fixing, testing and commissioning of PVC multi inlet floor trap/ p trap of self cleansing design moulded or fabricated, if not available insize mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors.110mm dia inlet 110mm dia out let - P Trap
CODE NO:18.49.1 Providing and fixing CP brass bib cock of approved quality conforming to IS 8931 - 15mm nominal bore.
CODE NO:18.22.1 Providing and fixing CP brass shower rose with 15 or20 mm inlet 100 mm diameter.
CODE NO:18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.for kitchen
CODE NO:17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gm.
CODE NO:18.65 Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements weighing not less than 106 grams.
CODE NO:18.56.1 Providing and fixing PTMT pillar cock of approved quality and colour - 15 mm nominal bore , 107 mm long, weighing not less than 110 gms
CODE NO:18.57.2 Providing and fixing PTMT , push cock of approved quality and colour - 15 mm nominal bore, 80 mm long, weighing not less than 46gms
CODE NO:12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes-110mm diameter
CODE NO:12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO:12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO:12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 110mm
CODE NO:12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams
CODE NO:1.10.1 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc.as required.Group (A)
CODE NO:1.25 Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
CODE NO:1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit , 2 way modular switch, modular plate , suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
CODE NO:NPSR-5 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CODE NO:NPSR-6 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6/16 A modular socket outlet and 6/16 A modular switch, connections etc. as required.
CODE NO:1.14.2 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq.mm + 1 x 2.5 sq.mm earth
CODE NO:1.14.3 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
CODE NO:1.14.4 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 6 sq.mm + 1 x 6 sq.mm earth wire
CODE NO:1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories .Make:Avonplast/Vijaya:- 25mm dia
CODE NO:2.5.1 Supplying and fixing of following ways surface / recess mounting , vertical type, 415 V , TPN MCB distribuition board of sherrt steel , dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12), double door.
CODE NO:2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 8 way, double door
CODE NO:2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way, double door
CODE NO:2.10.1 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc .as required. -Single Pole
CODE NO:2.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc .as required. -Double Pole
CODE NO:NPSR- 7 Supplying and fixing 40 amps to 63 amps rating,Triple pole, 415 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager
CODE NO:NPSR-8 Supplying and fixing 40 amps to 63 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO:NPSR-9 Supplying and fixing 100 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO:2.14.1 Supplying and fixing following rating , four pole ,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 25 A
CODE NO:2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A
CODE NO:NPSR- 10 Supply and fixing of surface mounting, batten type 20W LED tube light (Four feet) luminiare with effecient driver (efficiency shall be more than 90%) & required minimum of 1600 lumens output, comprising of high quality diffuser technology complete with efficient & constant current output driver suitable for operation on 230V, single phase, 50Hz AC supply, efficient heat sink, effective thermal management and with colour temperature shall be >5000K. The LED with suitable control gear and power factor >0.9. and necessary fixing accessories as required. Make: Philips - Smart light BN021C LED20S PSC CW GR52 or similar Wipro or equivalent.
CODE NO:NPSR- 11 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips
CODE NO:NPSR- 12 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KVgrade.
CODE NO:9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
CODE NO:5.2 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required
CODE NO:NPSR-13 Supply and laying of earthing and cable gland earthing using 10 SWG copper wire.
CODE NO:NPSR-14 Supply of 11KV 3Cx185 Sq.mm HT XLPE Aluminium armoured ug cable, without any cable joint. all complete as per specifications, drawings and / or as required by the PED.
CODE NO:NPSR-15 Supply and providing of 11KV indoor type heat shrinkable end termination suitable for 3Cx185 Sq.mm HT XLPE aluminium ug cable. All complete as per specifications, drawing and/or as required by PED.
CODE NO:8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.as required - above 120 sq.mm and upto 400 sq.mm
CODE NO:NPSR-16 Supply of 3 1/2 x 300sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO:NPSR-17 Supply of 3 1/2 x 240sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO:NPSR-18 Supply of 4 x6 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO:NPSR-19 Supply of 4 x4 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO:NPSR- 20 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
CODE NO:NPSR-21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
CODE NO:9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
CODE NO:9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
CODE NO:7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm
CODE NO:7.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
CODE NO:7.1.1 Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand ushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
CODE NO:NPSR-22 Supply, testing and commissioning of 630A, 11KV, 25KA, Motorised and SCADA ready load break switch attachement to the existing Ring main switchgear unit at existing 11KV PED RMS Yard, Type SF6 insulated and motorized construction all complete as required by PED. The item including all transformer protections and necessary safety accessories, The plinth shall be constructed by civil contractor based on the load calculations given by the electrical contractor etc. All complete as per specifications, drawing and/or as required by PED.
CODE NO:NPSR-23 Supply and erection of 2.1 Mtr. height 50mm diameter GI Poles around the HT switchgear/Transformer yard and laid with 25x25mm welded mesh with 2 coats of Alminum paint on it. The pole to pole gap will be maintained as 2.25Mts max. (1/5th of the Pole will be embedded in the ground). The item including required civil works and kerb wall etc.
CODE NO:NPSR-24 Supply, Unloading & handling, erection , testing and commissioning of 11KV/433V, 500 KVA of outdoor type, oil filled , copper wound, natural cooled (ONAN) type energy efficient transformer with the following specifications etc. energy efficient Transformer (IS:1180) with off load tap changer.The transformer cooling shall be of with oil and natural air. The items including necessary fixing accessories with all complete as required by PED. Rated Voltage HV Windings - 11 KV LV Windings - 433 V No load voltage ratio - 11 KV/ 433 V Rated Frequency - 50 Hz Winding Connections HV Windings - DELTA LV Windings - STAR Vector Group - Dyn 11 Terminal arangement Primary - 11KV Cable box Secondary - 433V Cable box. Temperature Rise by resistance - 90 Degree C Ambient Temperature - 50 Degree C Core lamination material - Cold Rolled Grain Oriented Core Type of cooling -Oil Natural Air Natural (ONAN) Type of winding insulation - DPC of class A insulation Losses No load losses and Load losses - as per energy efficiency requirements/standards. No load current (% of rated current) : Less than 1.5% Tap Changes Type - OFF circuit Range - +5% to -15% in steps of 1.25%
CODE NO: NPSR-25 Supply, installation, testing and commissioning of out door type (IP 65) LT Feeder Pillar fabricated with 14G CRCA sheet steel and powder coated, aluminium busbars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements, minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications. 4 Way LT Feeder Pillar Incoming: 400A TPN MCCB - 1 no. Outgoing: 200A TPN FUSE - 4 nos.
CODE NO: NPSR-26 Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearence shall not less than 25 mm for phase-phase and 19mm for phase- neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note:panels costing should be as per sld & with respect to PED standards Metering Panel Incomer : 200A TPN FSU : 1 no. Outgoings : 20 Sets each comprising of: a) 40A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 40A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Dummy chamber for Fixing three phase energy Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
CODE NO: NPSR-27 COMMON PANEL Incomer 200A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 200/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 200A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 100A, TPN, FSU - 2 Nos 63A, TPN, FSU - 2 Nos
CODE NO: NPSR-28 EXTERNAL LIGHTING PANEL Incomer 63A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 63/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 63A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 32A, TPN, MCB - 2 Nos Timer switch (daily)/ digital time switches daily programme with standby battery (3years) - 2 channel . Make:L&T-Hagger/Legrand-Lexic - 2 Nos
CODE NO:14.4 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters(750mm(d)x750mm(w)
CODE NO:NPSR-29 Providing earthen cable trenches, including necessary excavation, supply and placing in position of sand, bricks / PCC protective slabs, cable markers and backfilling in compacted layers, all complete as per specifications, drawings and /or as directed by the Engineer.450 mm wide x 600 mm deep for LT cables
CODE NO:NPSR-30 Supply and installation of inspection chamber of 750mm x 750mm x 750mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO:NPSR-31 Supply and installation of inspection chamber of 600mm x 600mm x 600mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO:19.6.2 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointedwith stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete -150 mm dia RCC pipe
CODE NO:19.6.4 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete - 300 mm dia RCC pipe.
CODE NO:31.160.1K Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces, couplers, reducer, endcaps etc.,complete all as per IS and CPWD specification. - 160mm dia.
CODE NO:31.160.1G Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 75mm dia.
CODE NO:5.4 Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.but without charcoal / coke and salt as required
CODE NO:5.6 Earthing with copper earth plate 600 mm x 600 mm x 3 mm per thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required
CODE NO:NPSR-32 Supply and laying of 25 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO:NPSR- 33 Supply and laying of 40 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO:NPSR- 34 Fire Bucket with sand(4 buckets and one sand)
CODE NO:NPSR- 35 Supply and fixing of 11KV danger board as per standard with all fixing accessories etc.
CODE NO:NPSR-36 Supply of 11KV Rubber gloves.
CODE NO:NPSR- 37 Supply of 1.1KV Rubber gloves.
CODE NO:NPSR- 38 Supply of Rubber mats.
CODE NO:NPSR- 39 Supply and fixing of shock treatment/First Aid treatment chart in Tamil, English and Hindi. All complete with necessary fixing accessories etc.
CODE NO:NPSR-40 LV Danger board stickers
CODE NO:NPSR-41 First aid box
CODE NO:NPSR- 42 dry type fire extinguisher -4.5 Kg for electrical room
CODE NO:NPSR-43 Supply, delivery, installation and commissioning of (Kone/johnson/schinldler/otis/Mitsubishi) lift for 4 persons (272 kg) passenger lift with the following specification - Including 1 Year O & M a) Battery Operated Emergency Light And Alarm Bell b) Call Register Signal And Vf Door Operator c) Landing Push Button In Landing Door Frames d) Automatic Rescue Device e) Stainless Steel Button With S.S. Cover f) Full Car Operating Panel g) Digital Position Indicator 7 Segment Display In Car And Landings h) False Ceiling In Car i) Infra Red Door Screen j) Scaffolding k) 3 Way Intercom / Press And Speak Phone l) Free Service For One Year m) Pit Ladder n) Ss Handrail On Rear Side o) Minor Builders Work
CODE NO:NPSR-44 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips-for lift
CODE NO:NPSR-45 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KVgrade.-for lift
CODE NO:NPSR-46 Fabrication, supply and installation of tubular street lighting pole of following length fabricated out of MS pipes of various diameters and swaged as per standards. A junction box incorporating 16A 4-way terminal, 6A MCB and other accessories shall be fixed to the pole for loop in & loop out of cable. XLPE cable connection to the lighting fixture at top, 8 SWG copper coil earthing, set of 50mm GI pipe of required length shall be provided at the bottom of the pole for cable entry to the junction box with the following type outreach curved bracket. The bottom of the pole will have a base plate of size 350 x 350 x 10mm MS plate welded to the pole. The base plate shall be fixed on 600 x 600 x 1500 mm deep pedestal in cement concrete 1:2:4, with approved hardware etc., as per directed by the Engineer-in-charge.(rate inclusive of civil works) Padmavathi distributors(inclusive of 12% GST) 3.0 meter with single outreach curved bracket -- K LITE
CODE NO:NPSR-47 48W LED Street Light Fitting
CODE NO:NPSR-48 FIRE PROTECTION HOSE REEL SYSTEM Supply, Erection, testing and commissioning of 2pole, AC 3phase / 415volts, 50hz centrifugal monoblock pump with 5.5 KW/ 7.5 HP motor of following pump capacity flow : 7.5lps (450lpm), head : 35mtrs. Pump is with Bronze impeller, SS410 shaft with mechanical seal, Class F insulation, voltage fluctuation ranging from 300 to 440volts. (Civil foundation bed, foundation bolts for pump mounting not in our scope, it is under client scope)
CODE NO:NPSR-50 Supply, laying of following size PVC/XLPE insulated outer sheathed (1100 V grade) alu. armoured, copper conductor cable laid in wall / floor /ceiling with suitable clamps. The rate shall inclusive of suitable double compression glands and crimping socket for the cables 4 Core 16 Sq.mm PVC insulated Cu Cable
CODE NO:NPSR-51 2 Core 1.5 Sq.mm PVC insulated Cu Cable
CODE NO:NPSR-52 Supplying, installing, G.I. 8 swg Earthing wire shall be run on floor / ceiling / walls, from the equipment to the panel and panel to the nearest Earth pit will be client scope.
CODE NO:NPSR-53 Supplying and fixing of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray shall be suitable for laying the above mentioned cables necessary bends, joints, Tee, Reducers etc., 100mm x 50 mm
CODE NO:NPSR-54 Supplying, installing, testing and commissioning of MS Pipes confirming to IS 1239 Heavy grade with painting. 100mm nominal dia
CODE NO:NPSR-55 80mm nominal dia
CODE NO:NPSR-56 25mm nominal dia
CODE NO:NPSR-57 Supplying, installing, testing and commissioning of ERW Heavy " C" Class buttweld fittings 100 x 65 mm nominal dia Reducer
CODE NO:NPSR-58 80 x 50 mm nominal dia Reducer
CODE NO:NPSR-59 100mm nominal dia bend
CODE NO:NPSR-60 80mm nominal dia bend
CODE NO:NPSR-61 25mm nominal dia elbow
CODE NO:NPSR-62 Supply, Installation, testing and commissioning of ASA Class 150, SORF, MS Flange 100mm nominal dia flange
CODE NO:NPSR-63 80mm nominal dia flange
CODE NO:NPSR-64 25mm nominal dia flange
CODE NO:NPSR-65 Supply, Installation, testing and commissioning of following diameter standard lever operated CI, PN : 16, Butterfly Valve 100mm Butterfly Valve
CODE NO:NPSR-66 80mm Butterfly valve
CODE NO:NPSR-67 Supply, Installation, testing and commissioning of following diameter CI body, ball type, flanged non return valve 80mm dia
CODE NO:NPSR-68 Supply, Installation, testing and commissioning of following diameter expansion bellows 80mm dia
CODE NO:NPSR-69 Supply, Installation, testing and commissioning of following diameter CI body, Y Strainer 100mm dia
CODE NO:NPSR-70 Supplying, installing, testing and commissioning of MS Pipes confirming to IS 1239 Heavy grade with painting. 80mm nominal dia
CODE NO:NPSR-71 25mm nominal dia
CODE NO:NPSR-72 Supply, Installation, testing and commissioning of 36mtr long hose reel drum with nozzle
CODE NO:NPSR-73 Supplying, installing, testing and commissioning of ERW Heavy " C" Class buttweld fittings 25mm nominal dia elbow
CODE NO:NPSR-74 Supply, Installation, testing and commissioning of following diameter forged brass ball valve 25mm dia
CODE NO:NPSR-75 Supply, fabricating of MS Structural support
CODE NO:NPSR-76 Fire Extinguihers: Supply, fixing of CO2 4.5kg fire extinguisher
CODE NO:NPSR-77 Supply, fixing of stored pressure ABC type 6kg fire extinguisher
CODE NO:NPSR-78 Supply and placed in position fire bucket stand with 4nos of round botom fire buckets
CODE NO: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m - all kinds of soil
CODE NO: 2.26.1 Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil.
CODE NO: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
CODE NO: 2.27A.1 Supplying and filling with gravel ( excluding rock) in trenches,plinth,sides of foundation etc. In layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc. complete including all lead and lift.
CODE NO : NPSR 1 Supplying and filling in plinth with M sand under floors including, watering, ramming consolidating and dressing complete
CODE NO: 2.27D.1 Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or stell rammers, including all leads and lift etc., complete for making play fields, running trees and courtyards.
CODE NO : 4.1.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 5.33.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of entering, shuttering,finishing and reinforcement, including admixtures inrecommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable. - All work upto plinth level
CODE NO: 5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
CODE NO: 5.34.1 Extra for providing richer mixes at all floor levels - Note:- Excess / less cement over the specified cement content used is payable / recoverable separately - Providing M-30 grade concrete instead of M-25 grade BMC / RMC . (Note:- cement content considered in M-30 is @ 340 kg /cum)
CODE NO: 5.22.10 Providing and placing M30 grade cover block for RCC work all levels
CODE NO: 5.9.1 Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns,etc. for mass concrete.
CODE NO: 5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings , balconies and access platform
CODE NO: 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
CODE NO: 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for: columns, pillars, piers, abutments, posts and struts.
CODE NO: 5.9.19 Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc.,including edges.
CODE NO: 5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
CODE NO: 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.4.1 (Full Brick) Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand)
CODE NO: 6.13.2 Half Brick Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand) 6 mm dia M.S. bars at every third course of masonry work.
CODE NO: 6.15 Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry
CODE NO: 16.15.1 Supplying at site : RCC standards post /struts/ rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs, wherever equired - (cost of earth works in excavation ,concrete works to be paid separately)
CODE NO: 9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood.
CODE NO: 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
CODE NO: 9.48.1 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S.flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
CODE NO: 9.53 Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 9.96.1 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc.complete:- 300 X 16 mm
CODE NO: 9.97.1 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete : - 300x10mm
CODE NO: 9.100.1 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete :-125mm
CODE NO: 9.165.1A Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
CODE NO: 10.11.1 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators , side /top/centre hung, with beading and all members such as F7D,F4B,K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings , complete all as per approved design, (sectional weight of only steel members shall be measured for payment) - Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 11.40.2 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete Providing and laying rectified ceramic sqm 1,001.26 rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 12.15.1 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sq.m impregnated with a coat of coarse sand at 60cudm per 10 sq.m including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete - with residual type petroleum bitumen of grade VG-10
CODE NO: 12.20 Providing and laying pressed clay tiles (as per approved pattern18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
CODE NO: 10.17 Providing and fixing M.S.fan clamp type I or II of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C.slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete
CODE NO: 12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
CODE NO: 13.8.2 15 mm cement plaster on rough side of single or halfbrick wall finished with a floating coat of neat cement of mix - 1:4 (1 cement: 4 fine sand)
CODE NO: 13.1.2 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
CODE NO: 13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
CODE NO: 13.29.1 18mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand)- Flush Band.
CODE NO: 13.37.1 White washing with lime to give on even shade - New work (three or more coats).
CODE NO: 13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
CODE NO: 13.48.3 Painting steel work with deluxe multisurface paint to give an even shade. Two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @ 0.80 ltr / 10 sqm of approved brand and manufacture
CODE NO: 13.50.1 Applying priming coat - with ready mixed pink pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
CODE NO: 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
CODE NO: 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and appproved size and desing/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with coarse sasnd etc. all complete.
CODE NO: 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
CODE NO: 12.1.1 Providing corrugated G.S sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete,exciuding the cost of purlins rafters and trusses and including cutting to size and shape wherever required -1.00 mm thicks with zinc coating not less than 275 gm/ sq.m
CODE NO: 12.4.1 Providing ridges or hips of width 60 cm metre 594.84 overall width plain G.S.sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete - 0.80mm thick with zinc coating not less than 275 gm /sq.m
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 12.75 Providing and laying water proofing for roof portion - Clean the surface using wire brush to remove fungus sticking on the tile surface . Remove the laitance and plaster residues with a chisel & hammer and repair any broken structure with civil work . Apply one coat MACRYL SL (Acrylic penetrating primer) Lay one coat of 3-4 mm thick MATPROOF ACR (Fibre reinforced Acrylic plaster) Elastomeric plaster on the flat area . Provide a seal coat with a flexible MACRYL again
CODE NO: 19.32.1A Making soak pit 2.5 m diameter 3 m deep with 45 x 45 cm dry brick honeycomb shaft with bricks of class designation 75 and 110mm dia UPVC pipe (type B) 1.8 m long complete as per stadard design with F.P.S.bricks
CODE NO: 11.40.1 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the anufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours, shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 11.36C Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 300 x 600 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size 300x600 mm
CODE NO: 19.30.3.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1cement : 4 coarse sand) C.I.cover with frame (light duty) 455 x 610 mm internal dimensions , total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size ), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete extra complete as per standard design - inside dimensions 600 x 850 mm and 45 cm deep for pipe line with three or more inlets - with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
CODE NO: 15.2.2 Nominal concrete 1:4:8 or leaner mix cum 693.28 (including equivalent design mix)
CODE NO: 15.3 Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
CODE NO: 15.5 Extra for cutting reinforcement bars manually / by mechanical means in R.C.C orR.B work (payment shall be made on the cross sectional area of R.C.C. or R.B.work)
CODE NO: 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
CODE NO: 15.12.2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area beyond 3 sq.metres
CODE NO: 14.43 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc.complete
CODE NO: 14.75 Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under including cutting the patch in proper shape , raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar , including disposal of rubbish , all complete.
CODE NO: 18.48A Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank for domestic water - Circular Tank
CODE NO: 18.62.3 Providing and fixing PTMT Ball cock of approved quality colour and make complete with Epoxy coatd aliminium rod with L.P / H.P.H.D.plastic ball - 25 mm nominal bore, 152 mm long, weighing not less than 440 gms
CODE NO: 18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50mm nominal bore
CODE NO: 18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 25mm nominal bore
CODE NO: NPSR 2 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 32mm nominal bore
CODE NO: 18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 20mm nominal outer dia pipes
CODE NO: 18.9.12 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
CODE NO: 18.9.14 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes
CODE NO: NPSR 3 Providing, fixing, testing and commissioning of PVC multi inlet floor trap / p trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete 1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 110mm dia inlet 75mm dia out let - Floor Trap
CODE NO: 19.33.1 Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes (type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter.
CODE NO: 19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
CODE NO: 19.33.1D Providing and fixing on wall face /column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110mm
CODE NO: 19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
CODE NO: 19.33.2A Providing and fixing on wall/column face unplasticisd - PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm
CODE NO: 19.33.2F Providing and fixing on wall face / column face unplasticised - PVC moulded fittings /accessories for unplasticised PVC soil and waste pipes conforming to IS:4985 including of jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - bend with door 50 mm.
CODE NO: 12.43.1 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 75mm
CODE NO: 12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 110mm
CODE NO: 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm
CODE NO: 17.18.2 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -coloured
CODE NO: 17.20.2 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete - black solid plastic seat with lid
CODE NO: 17.25.2 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings -angle back wash basin of size 600x480mm
CODE NO: 18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
CODE NO: NPSR 4 Providing, fixing, testing and commissioning of PVC multi inlet floor trap/ p trap of self cleansing design moulded or fabricated, if not available insize mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors.110mm dia inlet 110mm dia out let - P Trap
CODE NO: 18.49.1 Providing and fixing CP brass bib cock of approved quality conforming to IS 8931 - 15mm nominal bore.
CODE NO: 18.22.1 Providing and fixing CP brass shower rose with 15 or20 mm inlet 100 mm diameter.
CODE NO: 18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.for kitchen
CODE NO: 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gm.
CODE NO: 18.65 Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements weighing not less than 106 grams.
CODE NO: 18.56.1 Providing and fixing PTMT pillar cock of approved quality and colour - 15 mm nominal bore , 107 mm long, weighing not less than 110 gms
CODE NO: 18.57.2 Providing and fixing PTMT , push cock of approved quality and colour - 15 mm nominal bore, 80 mm long, weighing not less than 46gms
CODE NO: 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
CODE NO: 12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO: 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO: 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams
CODE NO: 1.10.1 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc.as required.Group (A)
CODE NO: 1.25 Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
CODE NO: 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
CODE NO: NPSR 5 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CODE NO: NPSR 6 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6/16 A modular socket outlet and 6/16 A modular switch, connections etc. as required.
CODE NO: 1.22.4 Supplying and fixing metal box of following sizes (nominal per size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 150 mm x 150 mm x 60 mm deep
CODE NO: 1.14.2 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq.mm + 1 x 2.5 sq.mm earth
CODE NO: 1.14.3 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
CODE NO: 1.14.4 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 6 sq.mm + 1 x 6 sq.mm earth wire
CODE NO: 1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories. Make:Avonplast / Vijaya:- 25mm dia
CODE NO: 2.5.1 Supplying and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribuition board of sherrt steel, dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12) , double door
CODE NO: 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 8 way, double door
CODE NO: 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way, double door
CODE NO: 2.10.1 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
CODE NO: 2.10.3 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Double Pole
CODE NO: NPSR 7 Supplying and fixing 40 amps to 63 amps rating,Triple pole, 415 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager
CODE NO: NPSR 8 Supplying and fixing 40 amps to 63 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: NPSR 9 Supplying and fixing 100 amps rating, 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: 2.14.1 Supplying and fixing following rating, four pole,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 25 A
CODE NO: 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A
CODE NO: NPSR 10 Supply and fixing of surface mounting, batten type 20W LED tube light (Four feet) luminiare with effecient driver (efficiency shall be more than 90%) & required minimum of 600 lumens output, comprising of high quality diffuser technology complete with efficient & constant current output driver suitable for operation on 230V, single phase, 50Hz AC supply, efficient heat sink, effective thermal management and with colour temperature shall be >5000K. The LED with suitable control gear and power factor >0.9. and necessary fixing accessories as required. Make: Philips - Smart light BN021C LED20S PSC CW GR52 or similar Wipro or equivalent
CODE NO: NPSR 11 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips
CODE NO: NPSR 12 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: 9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
CODE NO: 5.2 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required
CODE NO: NPSR 13 Supply and laying of earthing and cable gland earthing using 10 SWG copper wire.
CODE NO: NPSR 14 Supply of 11KV 3Cx185 Sq.mm HT XLPE Aluminium armoured ug cable, without any cable joint. all complete as per specifications, drawings and / or as required by the PED.
CODE NO: NPSR 15 Supply and providing of 11KV indoor type heat shrinkable end termination suitable for 3Cx185 Sq.mm HT XLPE aluminium ug cable. All complete as per specifications, drawing and/or as required by PED.
CODE NO: 8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.as required - above 120 sq.mm and upto 400 sq.mm
CODE NO: NPSR 16 Supply of 3 1/2 x 300sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR 17 Supply of 3 1/2 x 240sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR 18 Supply of 4 x6 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR 19 Supply of 4 x4 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR 20 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
CODE NO: NPSR 21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
CODE NO: 9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
CODE NO: 9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
CODE NO: 7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.1.1 Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand ushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
CODE NO: NPSR 22 Supply and erection of 2.1 Mtr. height 50mm diameter GI Poles around the HT switchgear/Transformer yard and laid with 25x25mm welded mesh with 2 coats of Alminum paint on it. The pole to pole gap will be maintained as 2.25Mts max. (1/5th of the Pole will be embedded in the ground). The item including required civil works and kerb wall etc.
CODE NO : NPSR 23 Supply, installation, testing and commissioning of out door type (IP 65) LT Feeder Pillar fabricated with 14G CRCA sheet steel and powder coated, aluminium busbars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements, minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications. 4 Way LT Feeder Pillar Incoming: 400A TPN MCCB - 1 no. Outgoing: 200A TPN FUSE - 4 nos.
CODE NO : NPSR 24 Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearence shall not less than 25 mm for phase-phase and 19mm for phase- neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note:panels costing should be as per sld & with respect to PED standards Metering Panel Incomer : 200A TPN FSU : 1 no. Outgoings : 20 Sets each comprising of: a) 40A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 40A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Dummy chamber for Fixing three phase energy Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
CODE NO : NPSR 25 Incomer 200A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 200/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 200A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 100A, TPN, FSU - 2 Nos 63A, TPN, FSU - 2 Nos
CODE NO : NPSR 26 Incomer 63A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 63/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 63A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A /sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 32A, TPN, MCB - 2 Nos Timer switch (daily)/ digital time switches daily programme with standby battery (3years) 2 channel . Make:L&T-Hagger/Legrand-Lexic - 2 Nos
CODE NO: 14.4 (Electrical) Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters
CODE NO: NPSR 27 Providing earthen cable trenches, including necessary excavation, supply and placing in position of sand, bricks / PCC protective slabs, cable markers and backfilling in compacted layers, all complete as per specifications, drawings and /or as directed by the Engineer. 450 mm wide x 600 mm deep for LT cables
CODE NO: NPSR 28 Supply and installation of inspection chamber of 750mm x 750mm x 750mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: NPSR 29 Supply and installation of inspection chamber of 600mm x 600mm x 600mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: 19.6.2 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointedwith stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete -150 mm dia RCC pipe
CODE NO: 19.6.4 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete - 300 mm dia RCC pipe.
CODE NO: 31.160.1K Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 160mm dia.
CODE NO: 31.160.1G Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 75mm dia.
CODE NO: 5.4 Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.but without charcoal / coke and salt as required
CODE NO: 5.6 Earthing with copper earth plate 600 mm x 600 mm x 3 mm per thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required
CODE NO: NPSR 30 Supply and laying of 25 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR 31 Supply and laying of 40 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR 32 Supply and providing the following safty items as per the requirements of satutory authorities: Fire Bucket with sand(4 buckets and one sand)
CODE NO: NPSR 33 Supply and fixing of 11KV danger board as per standard with all fixing accessories etc.
CODE NO: NPSR 34 Supply of 11KV Rubber gloves.
CODE NO: NPSR 35 Supply of 1.1KV Rubber gloves.
CODE NO: NPSR 36 Supply of Rubber mats.
CODE NO: NPSR 37 Supply and fixing of shock treatment/First Aid treatment chart in Tamil, English and Hindi. All complete with necessary fixing accessories etc.
CODE NO: NPSR 38 LV Danger board stickers
CODE NO: NPSR 39 First aid box
CODE NO: NPSR 40 Dry type fire extinguisher -4.5 Kg for electrical room
CODE NO: NPSR 41 Supply, installation ,testimg and commissiong of sewage cutter pump to be fixing in existing septic tank for pumping sewage waste to proposed STP with control pansories as required
CODE NO: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m - all kinds of soil
CODE NO: 2.26.1 Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil.
CODE NO: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
CODE NO: 2.27A.1 Supplying and filling with gravel ( excluding rock) in trenches,plinth,sides of foundation etc. In layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc. complete including all lead and lift
CODE NO: NPSR-1 Supplying and filling in plinth with M sand under floors including, watering, ramming consolidating and dressing complete
CODE NO: 2.27D.1 Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or stell rammers, including all leads and lift etc., complete for making play fields, running trees and courtyards.
CODE NO:4.1.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 5.33.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of entering, shuttering,finishing and reinforcement, including admixtures inrecommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable. - All work upto plinth level
CODE NO: 5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
CODE NO: 5.22.10 Providing and placing M30 grade cover block for RCC work all levels
CODE NO: 5.9.1 Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns,etc. for mass concrete.
CODE NO: 5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings , balconies and access platform
CODE NO: 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
CODE NO: 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for: columns, pillars, piers, abutments, posts and struts.
CODE NO:5.9.19 Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc.,including edges.
CODE NO: 5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (Approved make) Fe - 415 or more
CODE NO: 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.4.1 Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand)
CODE NO: 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand) 6 mm dia M.S. bars at every third course of masonry work .
CODE NO: 6.15 Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry
CODE NO:16.15.1 Supplying at site : RCC standards post / struts/ rails/ pales of mix 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs, wherever required - (cost of earth works in excavation ,concrete works to be paid separately)
CODE NO:16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and appproved size and desing/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with coarse sasnd etc. all complete.
CODE NO: 9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood.
CODE NO: 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
CODE NO: 9.48.1 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S.flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
CODE NO: 9.53 Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 9.96.1 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc.complete:- 300 X 16 mm
CODE NO: 9.97.1 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete : - 300x10mm
CODE NO: 9.100.1 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete :-125mm
CODE NO: 9.165.1A Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
CODE NO:10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks , mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to ISS :4454 -part 1 and M.S.top cover of required thickness for rolling shutters - 80 x 1.25mm M.S.laths with 1.25 mm thick top cover
CODE NO: 10.11.1 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators , side /top/centre hung, with beading and all members such as F7D,F4B,K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings , complete all as per approved design, (sectional weight of only steel members shall be measured for payment) - Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 11.40.2 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete Providing and laying rectified ceramic sqm 1,001.26 rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 12.15.1 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sq.m impregnated with a coat of coarse sand at 60cudm per 10 sq.m including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete - with residual type petroleum bitumen of grade VG-10
CODE NO: 12.20 Providing and laying pressed clay tiles (as per approved pattern18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
CODE NO: 10.17 Providing and fixing M.S.fan clamp type I or II of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C.slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete
CODE NO: 12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
CODE NO: 13.8.2 15 mm cement plaster on rough side of single or halfbrick wall finished with a floating coat of neat cement of mix - 1:4 (1 cement: 4 fine sand)
CODE NO: 13.1.2 12mm cement plaster of mix -1:6 ( 1 cement : 6 fine sand)
CODE NO:13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
CODE NO: 13.29.1 18mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand)- Flush Band.
CODE NO: 13.37.1 White washing with lime to give on even shade - New work (three or more coats).
CODE NO: 13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
CODE NO: 13.48.3 Painting steel work with deluxe multisurface paint to give an even shade. Two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @ 0.80 ltr / 10 sqm of approved brand and manufacture
CODE NO: 13.50.1 Applying priming coat - with ready mixed pink pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
CODE NO: 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
CODE NO: 15.2.2 Nominal concrete 1:4:8 or leaner mix cum 693.28(including equivalent design mix)
CODE NO: 15.3 Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
CODE NO: 15.5 Extra for cutting reinforcement bars manually / by mechanical means in R.C.C orR.B work (payment shall be made on the cross sectional area of R.C.C. or R.B.work)
CODE NO: 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
CODE NO: 15.12.2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area beyond 3 sq.metres
CODE NO: 14.43 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc.complete
CODE NO: 11.40.1 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours, shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 12.1.1 Providing corrugated G.S sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete,exciuding the cost of purlins rafters and trusses and including cutting to size and shape wherever required -1.00 mm thicks with zinc coating not less than 275 gm/ sq.m
CODE NO: 14.75 Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar , including disposal of rubbish,all complete
CODE NO:18.48A Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank for domestic water - Circular Tank
CODE NO:18.62.3 Providing and fixing PTMT Ball cock of approved quality colour and make complete with Epoxy coatd aliminium rod with L.P / H.P.H.D.plastic ball - 25 mm nominal bore, 152 mm long, weighing not less than 440 gms
CODE NO:18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50mm nominal bore
CODE NO:18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 25mm nominal bore
CODE NO:NPSR -2 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 32mm nominal bore
CODE NO:18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 20mm nominal outer dia pipes
CODE NO:18.9.12 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
CODE NO: 18.9.14 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes
CODE NO: NPSR - 3 Providing, fixing, testing and commissioning of PVC multi inlet floor trap / p trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete 1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 110mm dia inlet 75mm dia out let - Floor Trap
CODE NO: 19.33.1 Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes (type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter.
CODE NO: 19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
CODE NO: 19.33.1D Providing and fixing on wall face /column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110mm
CODE NO: 19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
CODE NO: 19.33.2A Providing and fixing on wall/column face unplasticisd - PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm
CODE NO: 19.33.2F Providing and fixing on wall face / column face unplasticised - PVC moulded fittings /accessories for unplasticised PVC soil and waste pipes conforming to IS:4985 including of jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - bend with door 75 mm.
CODE NO: 12.43.1 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 75mm
CODE NO:12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 110mm
CODE NO: 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm
CODE NO: 17.18.2 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -coloured
CODE NO: 17.20.2 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete - black solid plastic seat with lid
CODE NO: 17.25.3 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings –angle back wash basin of size 600x480mm
CODE NO: 18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
CODE NO: NPSR - 4 Providing, fixing, testing and commissioning of PVC multi inlet floor trap/ p trap of self cleansing design moulded or fabricated, if not available insize mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors.110mm dia inlet 110mm dia out let - P Trap
CODE NO: 18.49.1 Providing and fixing CP brass bib cock of approved quality conforming to IS 8931 - 15mm nominal bore.
CODE NO: 18.22.1 Providing and fixing CP brass shower rose with 15 or20 mm inlet 100 mm diameter.
CODE NO: 18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.for kitchen
CODE NO: 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gm.
CODE NO: 18.65 Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements weighing not less than 106 grams.
CODE NO: 18.56.1 Providing and fixing PTMT pillar cock of approved quality and colour - 15 mm nominal bore , 107 mm long, weighing not less than 110 gms
CODE NO: 18.57.2 Providing and fixing PTMT , push cock of approved quality and colour - 15 mm nominal bore, 80 mm long, weighing not less than 46gms
CODE NO: 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
CODE NO: 12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO: 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO: 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams
CODE NO:19.32.1A Making soak pit 2.5 m diameter 3 m deep with 45 x 45 cm dry brick honeycomb shaft with bricks of class designation 75 and 110mm dia UPVC pipe (type B) 1.8 m long complete as per stadard design with F.P.S.bricks
CODE NO:19.30.3.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I.cover with frame (light duty) 455 x 610 mm internal dimensions , total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size ), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete extra complete as per standard design - inside dimensions 600 x 850 mm and 45 cm deep for pipe line with three or more inlets - with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
CODE NO:24.4.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia , conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete , for all depths - 200 mm nominal size dia
CODE NO:31.250.1E Supplying of electrically operated wet type submersible motor and pumpset (Texmo/KSB/Taro/Kirloskar make), AC 3 phase, 415 volts, 50 Hz, 2900-3000 RPM. The pump shall have brass impeller, high grade steel shaft with sufficient stages having outlet size of 2"/2.5"/3" dia. to suit the borewell (150 / 200mm dia.), complete.The rate includes, all taxes, freight, etc., FOR at site in UT of Puducherry. The pumpset shall be guaranteed for a period of one year from the date of commissioning.(10 HP Submersible motor and pumpset).
CODE NO: 1.10.1 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc.as required.Group (A)
CODE NO: 1.25 Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
CODE NO: 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
CODE NO: NPSR - 5 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CODE NO: NPSR - 6 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6/16 A modular socket outlet and 6/16 A modular switch, connections etc. as required.
CODE NO: 1.22.4 Supplying and fixing metal box of following sizes (nominal per size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 150 mm x 150 mm x 60 mm deep
CODE NO: 1.14.2 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq.mm + 1 x 2.5 sq.mm earth
CODE NO: 1.14.3 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
CODE NO: 1.14.4 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 6 sq.mm + 1 x 6 sq.mm earth wire
CODE NO: 1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories. Make:Avonplast / Vijaya:- 25mm dia
CODE NO: 2.5.1 Supplying and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribuition board of sherrt steel, dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12) , double door
CODE NO: 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 8 way, double door
CODE NO: 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way, double door
CODE NO: 2.10.1 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
CODE NO: 2.10.3 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Double Pole
CODE NO: NPSR-7 Supplying and fixing 40 amps to 63 amps rating,Triple pole, 415 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager
CODE NO: NPSR-8 Supplying and fixing 40 amps to 63 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: NPSR-9 Supplying and fixing 100 amps rating, 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: 2.14.1 Supplying and fixing following rating, four pole,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 25 A
CODE NO: 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A
CODE NO: NPSR-10 Supply and fixing of surface mounting, batten type 20W LED tube light (Four feet) luminiare with effecient driver (efficiency shall be more than 90%) & required minimum of 600 lumens output, comprising of high quality diffuser technology complete with efficient & constant current output driver suitable for operation on 230V, single phase, 50Hz AC supply, efficient heat sink, effective thermal management and with colour temperature shall be >5000K. The LED with suitable control gear and power factor >0.9. and necessary fixing accessories as required. Make: Philips - Smart light BN021C LED20S PSC CW GR52 or similar Wipro or equivalent
CODE NO: NPSR-11 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips
CODE NO: NPSR-12 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: 9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
CODE NO: 5.2 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required
CODE NO: NPSR-13 Supply and laying of earthing and cable gland earthing using 10 SWG copper wire.
CODE NO: NPSR-14 Supply of 11KV 3Cx185 Sq.mm HT XLPE Aluminium armoured ug cable, without any cable joint. all complete as per specifications, drawings and / or as required by the PED.
CODE NO: NPSR-15 Supply and providing of 11KV indoor type heat shrinkable end termination suitable for 3Cx185 Sq.mm HT XLPE aluminium ug cable. All complete as per specifications, drawing and/or as required by PED.
CODE NO: 8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.as required - above 120 sq.mm and upto 400 sq.mm
CODE NO: NPSR-16 Supply of 3 1/2 x 300sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-17 Supply of 3 1/2 x 240sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-18 Supply of 4 x6 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-19 Supply of 4 x4 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-20 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
CODE NO: NPSR-21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
CODE NO: 9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
CODE NO: 9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
CODE NO: 7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.1.1 Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand ushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
CODE NO: NPSR-22 Supply and erection of 2.1 Mtr. height 50mm diameter GI Poles around the HT switchgear/Transformer yard and laid with 25x25mm welded mesh with 2 coats of Alminum paint on it. The pole to pole gap will be maintained as 2.25Mts max. (1/5th of the Pole will be embedded in the ground). The item including required civil works and kerb wall etc.
CODE NO: NPSR-23 Supply, installation, testing and commissioning of out door type (IP 65) LT Feeder Pillar fabricated with 14G CRCA sheet steel and powder coated, aluminium busbars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements, minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications. 4 Way LT Feeder Pillar Incoming: 400A TPN MCCB - 1 no. Outgoing: 200A TPN FUSE - 4 nos.
CODE NO: NPSR-24 Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearence shall not less than 25 mm for phase-phase and 19mm for phase- neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note:panels costing should be as per sld & with respect to PED standards Metering Panel Incomer : 200A TPN FSU : 1 no. Outgoings : 20 Sets each comprising of: a) 40A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 40A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Dummy chamber for Fixing three phase energy Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
CODE NO: NPSR-25 COMMON PANEL Incomer 200A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 200/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 200A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 100A, TPN, FSU - 2 Nos 63A, TPN, FSU - 2 Nos
CODE NO: NPSR-26 EXTERNAL LIGHTING PANEL Incomer 63A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 63/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 63A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A /sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 32A, TPN, MCB - 2 Nos Timer switch (daily)/ digital time switches daily programme with standby battery (3years) 2 channel . Make:L&T-Hagger/Legrand-Lexic - 2 Nos
CODE NO: 14.4 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters(750mm(d)x750mm(w))
CODE NO: NPSR-27 Providing earthen cable trenches, including necessary excavation, supply and placing in position of sand, bricks / PCC protective slabs, cable markers and backfilling in compacted layers, all complete as per specifications, drawings and /or as directed by the Engineer. 450 mm wide x 600 mm deep for LT cables
CODE NO: NPSR-28 Supply and installation of inspection chamber of 750mm x 750mm x 750mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: NPSR-29 Supply and installation of inspection chamber of 600mm x 600mm x 600mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: 19.6.2 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointedwith stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete -150 mm dia RCC pipe
CODE NO: 19.6.4 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete - 300 mm dia RCC pipe.
CODE NO: 31.160.1K Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 160mm dia.
CODE NO: 31.160.1G Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 75mm dia.
CODE NO: 5.4 Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.but without charcoal / coke and salt as required
CODE NO: 5.6 Earthing with copper earth plate 600 mm x 600 mm x 3 mm per thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required
CODE NO: NPSR-30 Supply and laying of 25 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-31 Supply and laying of 40 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-32 Supply and providing the following safty items as per the requirements of satutory authorities: Fire Bucket with sand(4 buckets and one sand)
CODE NO: NPSR-33 Supply and fixing of 11KV danger board as per standard with all fixing accessories etc.
CODE NO: NPSR-34 Supply of 11KV Rubber gloves.
CODE NO: NPSR-35 Supply of 1.1KV Rubber gloves.
CODE NO: NPSR-36 Supply of Rubber mats.
CODE NO: NPSR-37 Supply and fixing of shock treatment/First Aid treatment chart in Tamil, English and Hindi. All complete with necessary fixing accessories etc.
CODE NO: NPSR-38 LV Danger board stickers
CODE NO: NPSR-39 First aid box
CODE NO: NPSR-40 Dry type fire extinguisher -4.5 Kg for electrical room
CODE NO: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m - all kinds of soil
CODE NO: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
CODE NO: 2.26.1 Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil.
CODE NO: 2.27A.1 Supplying and filling with gravel ( excluding rock) in trenches,plinth,sides of foundation etc. In layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc. complete including all lead and lift
CODE NO: NPSR-1 Supplying and filling in plinth with M sand under floors including, watering, ramming consolidating and dressing complete
CODE NO: NPSR-2 Providing and laying m. sand and lime mix 1:1 of 150mm consolidated thickness using 0.65cumof M.sand & 0.50cum of lime for 1cum including cost and conveyance of M. sand and lime to the work site and stacking to the standard departmental gauge for premeaurement, mixing the required quantities of M.sand and lime, spreading watering and compacting the mix with earth rammer including the labour charges for mixing, spreading and compacting etc., completed.
CODE NO: 4.1.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 4.1.6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 4.2.3 Constructions of granular sub-base by providing coarse graded meteraial, spreading in uniform layer with motor grader on prepatred surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density complete as per clause 401 of MoRTH specification, 4th Revision for grading III material.
CODE NO: 5.33.1 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of entering, shuttering,finishing and reinforcement, including admixtures inrecommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable. - All work upto plinth level
CODE NO: 5.33.2 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability. Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
CODE NO: 5.22.10 Providing and placing M30 grade cover block for RCC work all levels
CODE NO: 5.9.1 Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns,etc. for mass concrete.
CODE NO: 5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings , balconies and access platform
CODE NO: 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
CODE NO: 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for: columns, pillars, piers, abutments, posts and struts.
CODE NO: 5.9.7 Centring and shuttering including strutting, propping etc. and removal of form for: Stairs (excluding landings) except spiral - staircases
CODE NO: 5.9.19 Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc.,including edges.
CODE NO: 5.16 Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size)
CODE NO: 5.18.1 Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick
CODE NO: 5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (Approved make) Fe - 415 or more
CODE NO: 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.4.1 Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand)
CODE NO: 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size ) upto plinth level with - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.13.2 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand) 6 mm dia M.S. bars at every third course of masonry work.
CODE NO: 6.15 Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry
CODE NO: 16.15.1 Supplying at site : RCC standards post / struts/ rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs, wherever required - (cost of earth works in excavation , concrete works to be paid separately)
CODE NO: 9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood.
CODE NO: 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
CODE NO: 9.48.1 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S.flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
CODE NO: 9.53 Providing 40x5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 9.96.1 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc.complete:- 1200 X 1200mm
CODE NO: 9.97.1 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete : - 300x10mm
CODE NO: 9.100.1 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete :-125mm
CODE NO: 9.118.1 Providing and fixing to existing door frames -- 24mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt edging on both sides . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws . The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1mm (+- 0.1mm) wall thickness . The lock rail made up of 'H' section, a uPVC hollow ection of size 100 x 24 mm and 2 mm (+-0.2 mm) wall thickness, fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers, complete as per manufacturer's specification (For W.C. and bathroom door)
CODE NO: 9.165.1A Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
CODE NO: 10.25.2 Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
CODE NO: 10.11.1 Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators , side /top/centre hung, with beading and all members such as F7D,F4B,K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings , complete all as per approved design, (sectional weight of only steel members shall be measured for payment) - Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C.1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size)
CODE NO: 11.36C Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 300 x 600 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size 300x600 mm
CODE NO: 11.40.1 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the anufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours, shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 11.40.2 Providing and laying rectified ceramic rustic / matt finish floor tiles of size 600x600 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete Providing and laying rectified ceramic sqm 1,001.26 rustic / matt finish floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make (Somany / Nitco) in all colours , shades, except white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 12.15.1 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sq.m impregnated with a coat of coarse sand at 60cudm per 10 sq.m including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete - with residual type petroleum bitumen of grade VG-10
CODE NO: 12.20 Providing and laying pressed clay tiles (as per approved pattern18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
CODE NO: 12.75 Providing and laying water proofing for roof portion - Clean the surface using wire brush to remove fungus sticking on the tile surface . Remove the laitance and plaster residues with a chisel & hammer and repair any broken structure with civil work . Apply one coat MACRYL SL (Acrylic penetrating primer) Lay one coat of 3-4 mm thick MATPROOF ACR (Fibre reinforced Acrylic plaster) Elastomeric plaster on the flat area . Provide a seal coat with a flexible MACRYL again
CODE NO: 10.17 Providing and fixing M.S.fan clamp type I or II of 16mm dia M.S. bar bent to shape with hooked ends in R.C.C.slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete
CODE NO: 12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
CODE NO: 13.8.2 15 mm cement plaster on rough side of single or halfbrick wall finished with a floating coat of neat cement of mix - 1:4 (1 cement: 4 fine sand)
CODE NO: 13.1.2 12mm cement plaster of mix -1:6 ( 1 cement : 6 fine sand)
CODE NO :13.22 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
CODE NO: 13.7.1 12mm cement plaster finished with a floating coat of neat cement of mix - 1:3 (1 cement :3 fine sand)
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.9.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
CODE NO: 13.29.1 18mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand)- Flush Band.
CODE NO: 13.37.1 White washing with lime to give on even shade - New work (three or more coats).
CODE NO: 13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
CODE NO: 13.48.3 Painting steel work with deluxe multisurface paint to give an even shade. Two or more coat applied @ 0.90 ltr / 10 sqm over an under coat of primer applied @ 0.80 ltr / 10 sqm of approved brand and manufacture
CODE NO: 13.50.1 Applying priming coat - with ready mixed pink pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
CODE NO: 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
CODE NO: 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and appproved size and desing/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with coarse sasnd etc. all complete.
CODE NO: 10.20 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
CODE NO: 12.1.1 Providing corrugated G.S sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete,exciuding the cost of purlins rafters and trusses and including cutting to size and shape wherever required -1.00 mm thicks with zinc coating not less than 275 gm/ sq.m
CODE NO: 12.4.1 Providing ridges or hips of width 60 cm metre 594.84 overall width plain G.S.sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete - 0.80mm thick with zinc coating not less than 275 gm /sq.m
CODE NO: 20.2.1 Boring , providing and installing bored cast -in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring , with bentonite solution and temporary casing of appropriate lenghth for setting out and removal of same and the lenghth of the pile to be embedded in the pile cap etc. all complete , including removal of excavated earth with all lifts and leads (length of pile for payment shall be measured upto bottom of pile cap) - 300 mm dia piles
CODE NO: 19.30.3.1 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I.cover with frame (light duty) 455 x 610 mm internal dimensions , total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size ), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete extra complete as per standard design - inside dimensions 600 x 850 mm and 45 cm deep for pipe line with three or more inlets - with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
CODE NO: 19.32.1A Making soak pit 2.5 m diameter 3 m deep with 45 x 45 cm dry brick honeycomb shaft with bricks of class designation 75 and 110mm dia UPVC pipe (type B) 1.8 m long complete as per stadard design with F.P.S.bricks
CODE NO: 24.4.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia , conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete , for all depths - 200 mm nominal size dia
CODE NO: 31.250.1E Supplying of electrically operated wet type submersible motor and pumpset (Texmo/KSB/Taro/Kirloskar make), AC 3 phase, 415 volts, 50 Hz, 2900-3000 RPM. The pump shall have brass impeller, high grade steel shaft with sufficient stages having outlet size of 2"/2.5"/3" dia. to suit the borewell (150 / 200mm dia.), complete.The rate includes, all taxes, freight, etc., FOR at site in UT of Puducherry. The pumpset shall be guaranteed for a period of one year from the date of commissioning.(10 HP Submersible motor and pumpset).
CODE NO: 15.2.2 Nominal concrete 1:4:8 or leaner mix cum 693.28 (including equivalent design mix)
CODE NO: 15.30 Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
CODE NO: 15.50 Extra for cutting reinforcement bars manually / by mechanical means in R.C.C orR.B work (payment shall be made on the cross sectional area of R.C.C. or R.B.work)
CODE NO: 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
CODE NO: 15.12.2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area beyond 3 sq.metres
CODE NO: 14.43 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc.complete
CODE NO: 18.48A Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank for domestic water - Circular Tank
CODE NO: 18.62.3 Providing and fixing PTMT Ball cock of approved quality colour and make complete with Epoxy coatd aliminium rod with L.P / H.P.H.D.plastic ball - 25 mm nominal bore, 152 mm long, weighing not less than 440 gms
CODE NO: 18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50mm nominal bore
CODE NO: 18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 25mm nominal bore
CODE NO: NPSR-3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete - 32mm nominal bore
CODE NO: 18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 20mm nominal outer dia pipes
CODE NO: 18.9.12 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
CODE NO: 18.9.14 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes
CODE NO: NPSR-4 Providing, fixing, testing and commissioning of PVC multi inlet floor trap / p trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete 1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 110mm dia inlet 75mm dia out let - Floor Trap
CODE NO: 19.33.1 Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes (type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter.
CODE NO: 19.33.1A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
CODE NO: 19.33.1D Providing and fixing on wall face /column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110mm
CODE NO: 19.33.2 Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
CODE NO: 19.33.2A Providing and fixing on wall/column face unplasticisd - PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm
CODE NO: 19.33.2F Providing and fixing on wall face / column face unplasticised - PVC moulded fittings /accessories for unplasticised PVC soil and waste pipes conforming to IS:4985 including of jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - bend with door 75 mm.
CODE NO: 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
CODE NO: 12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO: 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO: 12.43.1 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 75mm
CODE NO: 17.10.2.3 Providing and fixing Stainless steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I.brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required - kitchen sink without drain board -470x420 mm bowl depth 178mm
CODE NO: 17.28.2.2 Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete - Flexible pipe - 40mm dia
CODE NO: 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm
CODE NO: 17.18.2 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -coloured
CODE NO: 17.20.2 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete - black solid plastic seat with lid
CODE NO: 17.25.2 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings -angle back wash basin of size 600x480mm
CODE NO: 18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
CODE NO: NPSR-5 Providing, fixing, testing and commissioning of PVC multi inlet floor trap/ p trap of self cleansing design moulded or fabricated, if not available insize mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors.110mm dia inlet 110mm dia out let - P Trap
CODE NO: 18.49.1 Providing and fixing CP brass bib cock of approved quality conforming to IS 8931 - 15mm nominal bore.
CODE NO: 18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.for kitchen
CODE NO: 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110mm diameter
CODE NO: 12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO: 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO: 12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc., complete 110mm
CODE NO: 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams
CODE NO: 1.10.1 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc.as required.Group (A)
CODE NO: 1.25 Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
CODE NO: 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
CODE NO: NPSR-6 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CODE NO: NPSR-7 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6/16 A modular socket outlet and 6/16 A modular switch, connections etc. as required.
CODE NO: 1.22.4 Supplying and fixing metal box of following sizes (nominal per size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 150 mm x 150 mm x 60 mm deep
CODE NO: 1.14.2 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq.mm + 1 x 2.5 sq.mm earth
CODE NO: 1.14.3 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
CODE NO: 1.14.4 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 6 sq.mm + 1 x 6 sq.mm earth wire
CODE NO: 1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories. Make:Avonplast / Vijaya:- 25mm dia
CODE NO: 2.5.1 Supplying and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribuition board of sherrt steel, dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12) , double door
CODE NO: 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 8 way, double door
CODE NO: 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way, double door
CODE NO: 2.10.1 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
CODE NO: 2.10.3 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Double Pole
CODE NO: NPSR-8 Supplying and fixing 40 amps to 63 amps rating,Triple pole, 415 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager
CODE NO: NPSR-9 Supplying and fixing 40 amps to 63 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: NPSR-10 Supplying and fixing 100 amps rating, 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: 2.14.1 Supplying and fixing following rating, four pole,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 25 A
CODE NO: 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A
CODE NO: NPSR-11 Supply and fixing of surface mounting, batten type 20W LED tube light (Four feet) luminiare with effecient driver (efficiency shall be more than 90%) & required minimum of 600 lumens output, comprising of high quality diffuser technology complete with efficient & constant current output driver suitable for operation on 230V, single phase, 50Hz AC supply, efficient heat sink, effective thermal management and with colour temperature shall be >5000K. The LED with suitable control gear and power factor >0.9. and necessary fixing accessories as required. Make: Philips - Smart light BN021C LED20S PSC CW GR52 or similar Wipro or equivalent
CODE NO: NPSR-12 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips
CODE NO: NPSR-13 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: 9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
CODE NO: NPSR-14 Supply and laying of earthing and cable gland earthing using 10 SWG copper wire.
CODE NO: NPSR-15 Supply of 11KV 3Cx185 Sq.mm HT XLPE Aluminium armoured ug cable, without any cable joint. all complete as per specifications, drawings and / or as required by the PED.
CODE NO: NPSR-16 Supply and providing of 11KV indoor type heat shrinkable end termination suitable for 3Cx185 Sq.mm HT XLPE aluminium ug cable. All complete as per specifications, drawing and/or as required by PED.
CODE NO: 8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.as required - above 120 sq.mm and upto 400 sq.mm
CODE NO: NPSR-17 Supply of 3 1/2 x 300sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-18 Supply of 3 1/2 x 240sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-19 Supply of 4 x6 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-20 Supply of 4 x4 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR-21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
CODE NO: NPSR-22 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
CODE NO: 9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
CODE NO: 9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
CODE NO: 7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.1.1 Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand ushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
CODE NO: NPSR-23 Supply and erection of 2.1 Mtr. height 50mm diameter GI Poles around the HT switchgear/Transformer yard and laid with 25x25mm welded mesh with 2 coats of Alminum paint on it. The pole to pole gap will be maintained as 2.25Mts max. (1/5th of the Pole will be embedded in the ground). The item including required civil works and kerb wall etc.
CODE NO: NPSR-24 Supply, Unloading & handling, erection , testing and commissioning of 11KV/433V, 500 KVA of outdoor type, oil filled , copper wound, natural cooled (ONAN) type energy efficient transformer with the following specifications etc. energy efficient Transformer (IS:1180) with off load tap changer.The transformer cooling shall be of with oil and natural air. The items including necessary fixing accessories with all complete as required by PED. a)Rated Voltage HV Windings - 11 KV LV Windings - 433 V No load voltage ratio - 11 KV/ 433 V Rated Frequency - 50 Hz b)Winding Connections HV Windings - DELTA LV Windings - STAR Vector Group - Dyn 11 c)Terminal arangement Primary - 11KV Cable box Secondary - 433V Cable box. Temperature Rise by resistance - 90 Degree C Ambient Temperature - 50 Degree C Core lamination material - Cold Rolled Grain Oriented Core Type of cooling -Oil Natural Air Natural (ONAN) Type of winding insulation - DPC of class A insulation d)Losses No load losses and Load losses - as per energy efficiency requirements/standards. No load current (% of rated current) : Less than 1.5% e)Tap Changes Type - OFF circuit Range - +5% to -15% in steps of 1.25% Note: The handling from the truck and placing on the plinth is included in the scope. The plinth shall be constructed by civil contractor based on the load calculations given by the electrical contractor. Suitable stopper fabricated out of MS angles shall be fixed to arrest the movement of the transformer.
CODE NO: NPSR-25 Supply, installation, testing and commissioning of out door type (IP 65) LT Feeder Pillar fabricated with 14G CRCA sheet steel and powder coated, aluminium busbars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements, minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications. a)4 Way LT Feeder Pillar i.Incoming: 400A TPN MCCB - 1 no. ii. Outgoing: 200A TPN FUSE - 4 nos.
CODE NO: NPSR-26 Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearence shall not less than 25 mm for phase-phase and 19mm for phase- neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note:panels costing should be as per sld & with respect to PED standards Metering Panel Incomer : 200A TPN FSU : 1 no. Outgoings : 20 Sets each comprising of: a) 40A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 40A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Dummy chamber for Fixing three phase energy Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
CODE NO: NPSR-27 COMMON PANEL Incomer 200A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 200/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 200A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 100A, TPN, FSU - 2 Nos 63A, TPN, FSU - 2 Nos
CODE NO: NPSR-28 EXTERNAL LIGHTING PANEL Incomer 63A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 63/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 63A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A /sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 32A, TPN, MCB - 2 Nos Timer switch (daily)/ digital time switches daily programme with standby battery (3years) 2 channel . Make:L&T-Hagger/Legrand-Lexic - 2 Nos
CODE NO: 14.40 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters(750mm(d)x750mm(w))
CODE NO: NPSR-29 Providing earthen cable trenches, including necessary excavation, supply and placing in position of sand, bricks / PCC protective slabs, cable markers and backfilling in compacted layers, all complete as per specifications, drawings and /or as directed by the Engineer. 450 mm wide x 600 mm deep for LT cables
CODE NO: NPSR-30 Supply and installation of inspection chamber of 750mm x 750mm x 750mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: NPSR-31 Supply and installation of inspection chamber of 600mm x 600mm x 600mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: 19.6.2 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointedwith stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete -150 mm dia RCC pipe
CODE NO: 19.6.4 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete - 300 mm dia RCC pipe.
CODE NO: 31.160.1K Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 160mm dia.
CODE NO: 31.160.1G Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 75mm dia.
CODE NO: 5.2 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required
CODE NO: 5.40 Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.but without charcoal / coke and salt as required
CODE NO: 5.60 Earthing with copper earth plate 600 mm x 600 mm x 3 mm per thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required
CODE NO: NPSR-32 Supply and laying of 25 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-33 Supply and laying of 40 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-34 Supply and providing the following safty items as per the requirements of satutory authorities: Fire Bucket with sand(4 buckets and one sand)
CODE NO: NPSR-35 Supply and fixing of 11KV danger board as per standard with all fixing accessories etc.
CODE NO: NPSR-36 Supply of 11KV Rubber gloves.
CODE NO: NPSR-37 Supply of 1.1KV Rubber gloves.
CODE NO: NPSR-38 Supply of Rubber mats.
CODE NO: NPSR-39 Supply and fixing of shock treatment/First Aid treatment chart in Tamil, English and Hindi. All complete with necessary fixing accessories etc.
CODE NO: NPSR-40 LV Danger board stickers
CODE NO: NPSR-41 First aid box
CODE NO: NPSR-42 Dry type fire extinguisher -4.5 Kg for electrical room
CODE NO: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m - all kinds of soil.
CODE NO: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
CODE NO: 2.26.1 Extra for every additional lift of 1.5m or part there of in excavation / banking excavated or stacked materials - all kinds of soil
CODE NO: NPSR 1 Supplying and filling in plinth with river sand under floors, including watering, ramming consolidating and dressing complete
CODE NO: 2.27D.1 Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller, or wooden or stell rammers, including all leads and lift etc., complete for making play fields, running trees and courtyards.
CODE NO: 4.1.2 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
CODE NO: 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centring, shuttering, finishing and reinforcement -All work upto plinth level 1:1.5:3 (1cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
CODE NO: 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and sting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and enforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
CODE NO: 5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
CODE NO: 5.9.1 Centring and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
CODE NO: 5.9.3 Centering and shuttering including strutting, propping etc and removal of form for - Suspended floors, roofs, landings, balconies and access platform
CODE NO: 5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and cantilevers
CODE NO: 5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts
CODE NO:5.9.21 Centering and shuttering including strutting, propping etc and removal of form for - Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
CODE NO: 5.18.1 Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick
CODE NO: 5.22.6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars
CODE NO: 5.22.10 Providing and placing M30 grade cover block for RCC work all levels
CODE NO: 6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
CODE NO: 6.4.1 (Full Brick) Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:4 ( 1 cement : 4 coarse sand)
CODE NO: 9.48.2 Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S.flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws ets..
CODE NO: 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
CODE NO: 11.36C Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make (Johnson / Asian / Somany / Nitco) in all colours, shades of size 300 x 600 mm as approved in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size 300x600 mm
CODE NO: 11.40.4 Providing and laying rectified ceramic rustic/ matt finish floor tiles of size 300*300mm or more (thickness to be specified by the manufacturer )of commercial quality conforming to IS:15622 of approved make ( somany / Nitco )in all colours shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) including pointing the joints with white cement and matching pigments etc., complete
CODE NO: 12.1.1 Providing corrugated G.S sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washers filled with white lead including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete, excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required -1.00 mm thick with zinc coating not less than 275 gm/ sq.m
CODE NO: 12.75 Providing and laying water proofing for roof portion - Clean the surface using wire brush to remove fungus sticking on the tile surface . Remove the laitance and plaster residues with a chisel & hammer and repair any broken structure with civil work . Apply one coat MACRYL SL (Acrylic penetrating primer) Lay one coat of 3-4 mm thick MATPROOF ACR (Fibre reinforced Acrylic plaster) Elastomeric plaster on the flat area . Provide a seal coat with a flexible MACRYL again
CODE NO: 13.7.2 Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
CODE NO: 13.8.2 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix - 1:4 (1 cement : 4 fine sand) Plastering on floor i.e. Grade Slab
CODE NO: 13.37.1 White washing with lime to give an even shade - new work (three or more coats)
CODE NO: 13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacturer on wall surface - water thinnable cement primer
CODE NO: 13.44.1 Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg / 10 sqm)
CODE NO: 13.50.3 Applying priming coat - with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works
CODE NO: 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
CODE NO: 16.68 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand , filling the joints with coarse sand etc. all complete.
CODE NO: 19.32.1A Making soak pit 2.5 m diameter 3 m deep with 45 x 45 cm dry brick honeycomb shaft with bricks of class designation 75 and 110mm dia UPVC pipe (type B) 1.8 m long complete as per standard design with F.P.S.bricks
CODE NO: 9.1.2V Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Vengai wood.
CODE NO: 9.21.1 Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part 1) non-decorative type, core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
CODE NO: 18.9.11 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall )-20mm nominal outer dia pipes
CODE NO: 18.9.12 Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
CODE NO: 18.9.14 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 40mm nominal outer dia pipes
CODE NO: 18.17.4 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 50mm nominal bore
CODE NO: 18.18.3 Providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete-25mm nominal bore
CODE NO: 18.48A Providing and placing on terrace(at all floor levels)polyethylene water storage tank ISI:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. for domestic water-Circular Tank (3000 litre Tank 22nos)
CODE NO: 18.62.3 Providing and fixing PTMT Ball cock of approved quality colour and make complete with Epoxy coated aluminium rod with L.P / H.P.H.D.plastic ball-25mm nominal bore, 152mm long, weighing not less than 440 gms.
CODE NO: NPSR 2 Providing, fixing, testing and commissioning of PVC multi inlet floor trap / p trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent arm jointing with solvent cement followed by application of leak proof adhesive like FRP paste including encasing all round fixing the floor trap in cement concrete1:2:4 ratio of size 300 x 300 mm x 250 mm height (approx) and making good the floors. 110mm dia inlet 75mm dia out let - Floor Trap
CODE NO: 12.43.1 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete 75mm
CODE NO: 12.43.2 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete 110mm
CODE NO: 19.33.1 Providing and fixing on wall /column face unplasticed - PVC soil and waste pipes (type-B) conforming to IS:13592-1992 including jointing with seal ring conformation to IS: 5382 leaving 10mm gap for thermal expansion - single socketed pipes 110mm diameter.
CODE NO: 19.33.1 A Providing and fixing on wall face / column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
CODE NO: 19.33.1 E Providing and fixing on wall face/column face unplasticised - PVC moulded fittings/accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735-1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion-heel rest bend 110mm.
CODE NO: 19.33.2 Providing and fixing on wall/column face unplasticised-PVC soil and waste pipes(type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
CODE NO: 19.33.2A Providing and fixing on wall/column face unplasticisd-PVC moulded fittings /accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - Single tee with door - 75x75x75mm
CODE NO: 19.33.2F Providing and fixing on wall face/column face unplasticised - PVC moulded fittings /accessories for unplasticised PVC soil and waste pipes conforming to IS:4985 including of jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion - bend with door 75 mm.
CODE NO: 17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm
CODE NO: 17.18.2 Providing and fixing P.V.C.low level flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete - 10 litre capacity -coloured
CODE NO: 17.20.2 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete - black solid plastic seat with lid
CODE NO: 17.25.2 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings –angle back wash basin of size 600x480mm
CODE NO: 17.73.2 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gm.
CODE NO: 18.51.1 Providing and fixing CP brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms - 15mm nominal bore.for kitchen
CODE NO: 18.53.1 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931- 15 mm nominal bore
CODE NO: 18.56.1 Providing and fixing PTMT pillar cock of approved quality and colour - 15 mm nominal bore , 107 mm long, weighing not less than 110 gms
CODE NO: 18.65 Providing and fixing PTMT soap dish holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements weighing not less than 106 grams.
CODE NO: 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes-110mm diameter
CODE NO: 12.42.1.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion - Coupler - 110mm
CODE NO: 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110mm bend
CODE NO: 12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc., complete 110mm
CODE NO: 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams
CODE NO: 1.10.1 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc.as required.Group (A)
CODE NO: 1.25 Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
CODE NO: 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit , 2 way modular switch, modular plate , suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
CODE NO: NPSR -3 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
CODE NO: NPSR -4 Supplying and fixing suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6/16 A modular socket outlet and 6/16 A modular switch, connections etc. as required.
CODE NO: 1.14.2 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq.mm + 1 x 2.5 sq.mm earth
CODE NO: 1.14.3 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
CODE NO: 1.14.4 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 6 sq.mm + 1 x 6 sq.mm earth wire
CODE NO: 1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories .Make:Avonplast/Vijaya:- 25mm dia
CODE NO : 2.5.1 Supplying and fixing of following ways surface / recess mounting , vertical type, 415 V , TPN MCB distribuition board of sherrt steel , dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12), double door.
CODE NO : 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 8 way, double door
CODE NO : 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)- 12 way, double door
CODE NO : 2.10.1 Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc .as required. -Single Pole
CODE NO : 2.10.3 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc .as required. -Double Pole
CODE NO: NPSR -5 Supplying and fixing 40 amps to 63 amps rating,Triple pole, 415 volts,'c' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Make:Siemens/ABB/L&T Hager
CODE NO: NPSR -6 Supplying and fixing 40 amps to 63 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: NPSR -7 Supplying and fixing 100 amps rating , 415 volts, 10kA 'c' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Four Pole
CODE NO: 2.14.1 Supplying and fixing following rating , four pole ,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 25 A
CODE NO: 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A
CODE NO: NPSR -8 Supply and fixing of surface mounting, batten type 20W LED tube light (Four feet) luminiare with effecient driver (efficiency shall be more than 90%) & required minimum of 1600 lumens output, comprising of high quality diffuser technology complete with efficient & constant current output driver suitable for operation on 230V, single phase, 50Hz AC supply, efficient heat sink, effective thermal management and with colour temperature shall be >5000K. The LED with suitable control gear and power factor >0.9. and necessary fixing accessories as required. Make: Philips - Smart light BN021C LED20S PSC CW GR52 or similar Wipro or equivalent.
CODE NO: NPSR -9 Supply and installation of 1 x 18w Wall Mounted decorative fittings (Available in Textured grey, textured brown, antique silver& sunflower green colours) Make: Philips
CODE NO: NPSR -10 Supply of 4 x 25sqmm armoured aluminium XLPE U.G cable- 1.1 KVgrade.
CODE NO: 9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
CODE NO: 5.2 Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required
CODE NO: NPSR -11 Supply and laying of earthing and cable gland earthing using 10 SWG copper wire.
CODE NO: NPSR -12 Supply of 11KV 3Cx185 Sq.mm HT XLPE Aluminium armoured ug cable, without any cable joint. all complete as per specifications, drawings and / or as required by the PED.
CODE NO: NPSR - 13 Supply and providing of 11KV indoor type heat shrinkable end termination suitable for 3Cx185 Sq.mm HT XLPE aluminium ug cable. All complete as per specifications, drawing and/or as required by PED.
CODE NO: 8.1.2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc.as required - above 120 sq.mm and upto 400 sq.mm
CODE NO: NPSR - 14 Supply of 3 1/2 x 300sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR - 15 Supply of 3 1/2 x 240sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR - 16 Supply of 4 x6 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR - 17 Supply of 4 x4 sqmm armoured aluminium XLPE U.G cable- 1.1 KV grade.
CODE NO: NPSR - 18 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm
CODE NO: NPSR - 19 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 6 sq. mm
CODE NO: 9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
CODE NO: 9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
CODE NO: 7.1.4 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.2.4 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
CODE NO: 7.1.1 Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand ushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
CODE NO: NPSR - 20 Supply, testing and commissioning of 630A, 11KV, 25KA, Motorised and SCADA ready load break switch attachement to the existing Ring main switchgear unit at existing 11KV PED RMS Yard, Type SF6 insulated and motorized construction all complete as required by PED. The item including all transformer protections and necessary safety accessories, The plinth shall be constructed by civil contractor based on the load calculations given by the electrical contractor etc. All complete as per specifications, drawing and/or as required by PED.
CODE NO: NPSR - 21 Supply and erection of 2.1 Mtr. height 50mm diameter GI Poles around the HT switchgear/Transformer yard and laid with 25x25mm welded mesh with 2 coats of Alminum paint on it. The pole to pole gap will be maintained as 2.25Mts max. (1/5th of the Pole will be embedded in the ground). The item including required civil works and kerb wall etc.
CODE NO: NPSR – 22 Supply, installation, testing and commissioning of out door type (IP 65) LT Feeder Pillar fabricated with 14G CRCA sheet steel and powder coated, aluminium busbars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements, minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications. 4 Way LT Feeder Pillar Incoming: 400A TPN MCCB - 1 no. Outgoing: 200A TPN FUSE - 4 nos.
CODE NO: NPSR – 23 Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearence shall not less than 25 mm for phase-phase and 19mm for phase- neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note: panels costing should be as per sld & with respect to PED standards. Metering Panel Incomer : 200A TPN FSU : 1 no. Outgoings : 20 Sets each comprising of: a) 40A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 40A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Dummy chamber for Fixing three phase energy Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
CODE NO: NPSR – 24 COMMON PANEL Incomer 200A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 200/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 200A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 100A, TPN, FSU - 2 Nos 63A, TPN, FSU - 2 Nos
CODE NO: NPSR – 25 EXTERNAL LIGHTING PANEL Incomer 63A, TPN, FSU - 1 Nos Phase indication lamps(R,Y,B) - 1 set. CT ratio 63/5A,CL:1.0 tape insulated bar primary type with suitable sorting links - 1 Set. Metering:Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set. Busbar: 63A, TPN, 36KA, for 1 sec Aluminium bus bar Phase: current density not more than 0.8A/sq.mm Neutral: half of the phase current (0.5 x phase) Earth: 25x3mm copper flat throught the panel length Outgoing: 32A, TPN, MCB - 2 Nos Timer switch (daily)/ digital time switches daily programme with standby battery (3years) 2 channel . Make:L&T-Hagger/Legrand-Lexic - 2 Nos
CODE NO: 14.4 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5m, including getting out the excavated soil, refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meters(750mm(d)x750mm(w)
CODE NO: NPSR-26 Providing earthen cable trenches, including necessary excavation, supply and placing in position of sand, bricks / PCC protective slabs, cable markers and backfilling in compacted layers, all complete as per specifications, drawings and /or as directed by the Engineer.450 mm wide x 600 mm deep for LT cables
CODE NO: NPSR-27 Supply and installation of inspection chamber of 750mm x 750mm x 750mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: NPSR-28 Supply and installation of inspection chamber of 600mm x 600mm x 600mm depth (clear internal dimensions) with 230mm thick Brick cable chamber with 50mm thick RCC removable slab cover as required.
CODE NO: NPSR-29 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointedwith stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete -150 mm dia RCC pipe
CODE NO: 19.6.4 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc, complete - 300 mm dia RCC pipe.
CODE NO: 31.160.1K Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 160mm dia.
CODE NO: 31.160.1G Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (1 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 75mm dia.
CODE NO: 5.4 Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.but without charcoal / coke and salt as required
CODE NO: 5.6 Earthing with copper earth plate 600 mm x 600 mm x 3 mm per thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required
CODE NO: NPSR-30 Supply and laying of 25 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-31 Supply and laying of 40 X 6 mm GI flat as body earthing and neutral earthing laying with necessary insulators and fixing accessories etc. all complete as per specifications, drawings and / or as directed by PED.
CODE NO: NPSR-32 Fire Bucket with sand(4 buckets and one sand)
CODE NO: NPSR-33 Supply and fixing of 11KV danger board as per standard with all fixing accessories etc.
CODE NO: NPSR-34 Supply of 11KV Rubber gloves.
CODE NO: NPSR-35 Supply of 1.1KV Rubber gloves.
CODE NO: NPSR-36 Supply of Rubber mats.
CODE NO: NPSR-37 Supply and fixing of shock treatment/First Aid treatment chart in Tamil, English and Hindi. All complete with necessary fixing accessories etc.
CODE NO: NPSR-38 LV Danger board stickers
CODE NO: NPSR-39 First aid box
CODE NO: NPSR-40 Dry type fire extinguisher -4.5 Kg for electrical room
CODE NO: NPSR-42 Supplying and providing of integrated solar steel lighting system including battery, charge controller , luminary ,mechanical mountings ,pole ,cables etc.,(inclusive of warranty &CMC charges), with specification which are listed below i. Battery 12.8V min ×40 Ah lithium ferro phosphate battery with 95% discharge with the suitable luminary for outdoor use. ii. Luminary 20W white LED with charge controller having MPPT housing with Li-Fe-Po4 battery. iii. PV Module • 75Wp minimum solar photovoltaic mono – crystalline Module • The PV module itself should be used to sense the ambient light level for switching ON and OFF the lamp. • No load current consumption should be less than 20 mA iv. Charge Controller 12V/10A MPPT v. Luminary Material Aluminium die-casted casing suitable for outdoor use and shall comply with IP65 vi. Charge time 4-5 Hours (by sun) vii. Discharge time 02 days or 24 hours viii. Duty cycle First 5 hours working with full brightness and next 3 hours with 60% brightness and the rest of time with 30% brightness .( this could be vary subject to requirement) ix. Mechanical components of the pole Pole height 5m above the ground level and 1m below the ground. Luminaire shall be at least 4.5m above ground level. x. Warranty period • The street lighting system (including the battery &luminary) should be warranted for a period of 5 years from the Date of supply and should maintain the system with comprehensive maintenance charges for five years. • The PV module (s) should be warranted for minimum period of 25 years from the date of supply. • Warranty card to be supplied with the system must contains the details of the system.
MUTHUSWAMYCONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid