Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AMONG BONAFIDE BIDS | |
| 2 | L2₹38.4 L+₹42,070 (1.11%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance REJECTED BEING L2 AMONG BONAFIDE TENDERS | |
| 3 | L3₹39.3 L+₹1.3 L (3.53%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L3 | Rejected-Finance REJECTED BEING L3 AMONG BONAFIDE TENDERS | |
| 4 | L4₹41.1 L+₹3.1 L (8.25%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L4 | Rejected-Finance REJECTED BEING L4 AMONG BONAFIDE TENDERS |
Tender Value
Refer Docs
EMD Value
₹45,500
Closing Date
21 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SUBROTO PARK
GE AF SUBROTO PARK DELHI CANTT - 110010
REPAIR MAINT AND SERVICING FOR COOLING TO HEATING OF WINDOW SPLIT TYPE ACs GEYSER AND CERTAIN MISC WORKS IN THE AREA OF AGE EM II UNDER GE AF SUBROTO PARK
2020_MES_383215_4
GE/SP/TOKEN-58/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF SUBROTO PARK DELHI CANTT
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE AF SUBROTO PARK
₹45,500
Yes
25 Jan 2021
4 Dec 2020
22 Dec 2020
4 Dec 2020
21 Dec 2020
7 Dec 2020
4 Dec 2020 - 6 Dec 2020
60 days
Amount
Overhauling and servicing of split type ACs 1.5 Ton / 2.0 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the A/C from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) washing the condensor and cooling coil complete with chemical followed with pressurized water jet complete as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system (cooling) and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor (h) Checking the functional of electronic remote control unit to ensure satisfactory functioning of unit complete all as specified and as directed by Engineer-in-charge.
All as per item No 01 of DCS above but window type AC of capacity 1.5 / 2.0 TR complete all as specified & directed by Engineer-in-Charge
Labour only to convert Split / Window AC 1.5 / 2.0 TR from cooling mode to heating mode or vice versa by necessary adjustments in electrical wiring / interlocking as required in existing heating element / heat pump / reverse solenoid valve including testing the unit and necessary modification / adjustment in remote control unit for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of unserviceable solinoid valve of Split type AC of Cap 1.5 / 2.0 TR including additional copper tubing of any size brazing work, pressure testing dehydraion and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and as directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable solinoid valve of Window type AC of Cap 1.5 / 2.0 TR including additional copper tubing of any size brazing work, pressure testing dehydraion and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and as directed by Engineer-in-charge
Supply & fix in replacement of unserviceable Starting relay as per existing complete all as specified and as directed by Engineer-in-charge Make- Hitech/Sriram/Kirloskar
Supply & fix in replacement of unserviceable Starting capacitor 120-150 mfd complete all as specified and as directed by Engineer-in-charge Make- Epcos / Tibcon/Sarada
Supply & fix in replacement of unserviceable Starting capacitor 36-100 mfd complete all as specified and as directed by Engineer-in-charge Make- Epcos / Tibcon/Sarada
Supply & fix in replacement of unserviceable Contactor single phase/3 phase for existing capacity and current rating complete all as specified and direced by Engr-in-Charge Make : L&T. Simons. C&S
Supply & fix in replacement of unserviceable Running capacitor 3.5 to 6 mfd complete all as specified and direced by Engr-in-Charge Make-Epcos/Sarada/Usha/Tibcon
Supply & fix in replacement of unserviceable Running capacitor 36 mfd complete all as specified and direced by Engr-in-Charge Make-Epcos/Usha
Supply & fix in replacement of unserviceable Running capacitor 45/50 mfd complete all as specified and direced by Engr-in-Charge Make-Epcos/Usha
Supply & fix in replacement of unserviceable Propeller fan(Aluminium) for split type AC of capacity 1.5 / 2.0 TR complete all as specified and direced by Engr-in-Charge Make : Cosmo/ OG
Supply & fix in replacement of unserviceable Condensor fan motor of any type of Split type ACs of capacity 1.5 /2.0 TR as per existing complete all as specified and direced by Engr-in-Charge
Supply & fix in replacement of unserviceable blower motor of any type of Split type ACs of capacity 1.5 /2.0 TR as per existing complete all as specified and direced by Engr-in-Charge
Supply & fix in replacement of unserviceable Blower for split type AC 1.5 / 2.0 TR as per existing complete all as specified and direced by Engr-in-Charge
S&F in replacement unserviceable compressor of capcity 2.0 TR for split type AC with washers, bolts and nuts single phase 230V 50 Hz working with filling of required gas upto 2 kg R-410A refrigerant including brazing of respective copper tubing incl providing of extra insulated copper tubing, leak check, dehydration of the system with compressed nitrogen for leak free area all as specified and directed by Engineer-in-Charge. Make: Kirloskar (Copeland) or euivalent in Danfoss. Note :- Contactor shall be provide 2 years garrantee/warranty certificate against above said items and incase compreesor get unserviceable in warranty period should be replace without claiming extra cost.
S&F in replacement unserviceable compressor of capcity 1.5 TR for split type AC with washers, bolts and nuts single phase 230V 50 Hz working with filling of required gas upto 2 Kg R-410A refrigerant including brazing of respective copper tubing incl providing of extra insulated copper tubing, leak check, dehydration of the system with compressed nitrogen for leak free area all as specified and directed by Engineer-in-Charge. Make: Kirloskar (Copeland) or euivalent in Danfoss. Note :- Contactor shall be provide 2 years garrantee/warranty certificate against above said items and incase compreesor get unserviceable in warranty period should be replace without claiming extra cost.
S&F in replacement unserviceable compressor for split type AC of capacity 2 TR as per existing including brazing work, laying of extra copper tubing, pressure testing, dehydration,gas charging upto required level and testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge Make kirloskar/LG/Carrier/Tecumsah
S&F in replacement unserviceable compressor for split type AC of capacity 1.5 TR as per existing including brazing work, laying of extra copper tubing, pressure testing, dehydration,gas charging upto required level and testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge Make kirloskar/LG/Carrier/Tecumsah
Supply and install of multi functional (heating/cooling) hi wall split type AC units indoor/outdoor copper tube evaporator and condencing unit capacity of 2 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 2 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty alomg with bill.
Supply and install of multi functional (heating/cooling) hi wall split type AC units indoor/outdoor copper tube evaporator and condencing unit capacity of 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty along with bill.
Supply & charging the refrigerant gas to Split type AC 2.0 TR / 1.5 TR upto required level after detecting & repairing leakage by brazing, provn of extra copper tubing if required improvement of efficiency, testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable Copper tubing of dia 5/8" complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable Copper tubing of dia 3/8" complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable Copper tubing of dia 1/2" complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable Copper tubing of dia 1/4" complete all as specified and directed by Engineer-in-charge
M&L for insulation to copper tubing of split type AC of cap 1.5 TR/2.0 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material and pvc tie complete all as specified and directed by Engineer-in-charge Make- Armaflex / Aeroflex/Thermobreak
M&L for repair to unserviceable cordless PCB remote control unit of split type AC of cap 1.5 TR/2.0 TR including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed by Engineer-in-charge
M&L for repair to unserviceable cordless PCB remote control unit of split type AC of cap 1.5 TR/2.0 TR, inverter Type including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of unserviceable Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 amps complete all as specified and directed by Engineer-in-charge. Make: Havells/Legrand/Siemens
Supply and fix in replacemnt of MCB SP 6-32 amps 230 Volt c series 50 Hz Single Phase complete all as specified and directed by Engineer-in-charge. Make Havells/L&T/Standerd
M&L for Dismantling,shifting of split type AC of any make & model from one location to another location and refixing the AC with gitties/fasteners, cutting wall/concrete incl arrangement of required T&P, laying of extra insulated copper tubing, positioning of condensing unit and stand, fixing of extra pvc flexible multistranded copper conductor of size 2.5 sq mm and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed by Engineer-in-charge
M&L for rewinding of condensor fan motor of split type AC of cap 1.5/2.0 TR including replacement of gun metal bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge
All as item No 34 above but blower motor capcity of 1.5 Ton/2 Ton split AC complete all as specified and directed by Engineer-in-Charge
S&F in replacement of unserviceable PVC insulated stranded 3 core flexible copper cable of size 2.5 sqmm 1100 V grade complete all as specified and as directed by Engineer-in-charge. Make-Polycab / Havells / Finolex / Universal
S&F in replacement of unserviceable PVC insulated stranded 3 core flexible copper cable of size 4 sqmm 1100 V grade complete all as specified and as directed by Engineer-in-charge. Make-Polycab / Havells / Finolex / Universal
S&F in replacement of unserviceable PVC insulated stranded 3 core flexible copper cable of size 6 sqmm 1100 V grade complete all as specified and as directed by Engineer-in-charge. Make-Polycab / Havells / Finolex / Universal
M&L Sub main wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 2 run of 4 sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith 1 run of 4 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete all as specified and as directed by Engineer-in-charge. Make- Plaza / Kinjal / Finolex/Kalinga
S&F in replacement low density polyehylene pipes (LDPE) of pressure rating 6 kg / cm3 drain pipes of size 20mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge
Labour only for analyzing and rectification of fault to voltage regulators of capacity 5 KVA complete and taking down/segigating of unsv spare parts from voltage stabilizer and fixing of following items all as directed by Engineer-in -Charge. (Note- Parts required for repair to voltage regulators will be measured and paid separately under the items supply only)
Supply only Main transformer copper wound of capacity 5 KVA as per existing complete all as specified and as directed by Engr-in-Charge.
Supply only Buck & boost relay complete all as specified and as directed by Engr-in-Charge.
Supply only Time delay circuit complete all as specified and as directed by Engr-in-Charge.
Supply only Electronic control card as per existing complete all as specified and as directed by Engr-in-Charge. .
Supply only Trigger transformer as per existing complete all as specified and as directed by Engineer in Charge.
Supply only High/low voltage protection circuit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacemnt of unserviceable Electronic control circuit board (PCB) of outdoor/indoor unit for CFC free split type AC of capacity 1.5/2.0 TR as per existing make and model complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacemnt of unserviceable Electronic control circuit board (PCB) inverter Type of outdoor unit/indoor unit for digital invertor fitted CFC free split type AC of capacity 1.5/2.0 TR as per existing make and model complete all as specified and as directed by Engineer-in-charge
Taking out old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut bolts disconnecting from suction & discharge side mechanically and electrically capacity 230 Volt AC including transportation, brazing work, laying of extra copper tubing, pressure testing, dehydration , as per following capacity complete all as specified and as directed by Engineer-in-charge
Window type AC of capacity 1.5 TR complete all as specified and as directed by Engineer-in-charge.
Compressor for Split type AC of capacity 1.5 TR complete all as specified and directed by Engineer-in-charge.
Compressor for Splittype AC of capacity 2.0 TR complete all as specified and directed by engineer-in-charge.
M&L for carrying out leakage testing of split type air conditioner of capacity 1.5 / 2.0 TR of existing make and type, charging dehydrated Nitrogen gas upto 280 PSI in refrigerant system for a period of 24 hours for detecting leakages and repairing of tubing by brazing / welding suitably and repeating the pressure test to obtain 100% leak proof condition in the system, charging the refrigerant gas R-22 / 410-A and testing complete all as specified and directed by Engineer-in-charge
S&F in replacement of body (kit) of window type AC 1.5 TR capacity including body, condesnor coil, cooling coil, blower motor, front grill and outer cover without compressor complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper tube condesnor assembly suitable for 1.5 TR window type air conditioner of any make complete all as specified and as directed by Engineer-in-charge. Note : - Charging of Refrigerant gas shall be inclusive in quoted rate.
Supply only in replacement of unserviceable remote control suitable for 1.5 / 2.0 Ton split type AC of existing make and type complete all as specified and as directed by Engineer-in-charge
S& F in replacement sub main wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with multi strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire but in green colour complete on surface/concealed and connected to common earth dolly of the following size complete all as specified and as directed by Engr-in-Charge. Note : Three run of PVC cable and one run of PVC conduit shall be measured as one unit length.
10 Sq.mm ( 2 single run of 10 Sqmm and one run of 10 Sqmm as earth wire) complete all as specified and as directed by Engr-in-Charge.
6 Sq.mm ( 4 single run of 6 Sqmm and one run of 6 Sqmm as earth wire) complete all as specified and directed by Engineer in Charge.
10 Sq.mm ( 4 single run of 10 Sqmm and one run of 10 Sqmm as earth wire) complete as per directions of Engineer-in-charge
Supply and installation in replacemnt of phase frequency corrector of capcity 25 HP of 3 phase corrector for 3 phase tower/cassate/ductable Spli AC and other 3 phase items , electrically controlled with interlocking system duly pre wired with multistranderd copper wire of duirable rating , powder coated metalic housing with hanged door and indicator for each phase. current rate 40A- 100 A, Voltage rating 440V all as specified and directedby Engr-in- Charge. Make: Phortran, ABC, Volot-on
Suplly and installation in replacemnt of voltage stabilizer capcity 5 KVA , AC Supply 180 Volt to 240 Volt , 50Hz fixing on wall all a sspecified and directed by Engr-in-Charge Make: V-Gurd/Blue gurd/Volini
Suplly and installation in replacemnt of voltage stabilizer capcity 3 KVA , AC Supply 180 Volt to 240 Volt , 50Hz fixing on wall all a sspecified and directed by Engr-in-Charge Make: V-Gurd/Blue gurd/Volini
Supply, installation and commissioning of commercial Aqua purifier plant, duble filter purification with UV+RO+TDS , capacity 25 Ltr per hour including connecting pipe lines as per site requiremnt and electrical connections with fixing on wall or given site all as specified and direced by Engr-in-Charge Make: Kent/Eureka fab/Aqua
Labour only to convert Split / Window AC 1.5 / 2.0 TR from heating mode to cooling mode or vice versa by necessary adjustments in electrical wiring / interlocking as required in removing of existing heating element / heat pump / reverse solenoid valve including testing the unit and necessary modification / adjustment in remote control unit for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement the following unserviceable spare parts for Water Storage Heater (Geyser) of capacity 25/50 Ltrs of any make & model installing in side of Subroto park and rectifying all the defects as mounted and fitted on wall with nut & bolts and re-fixing to its original postion after repair and making geyser satisfactory functional complete all as specified and as directed by Engineer-in-charge
Geyser assembly including rubber seal,screw as per existing model complete all as specified and as directed by Engineer-in-charge.
Heating element 2000 watt 240 volts AC including seal, washers complete all as specified and as directed by Engineer-in-charge Make- Theta / Daspass or as per existing model.
Heating element 1500 watt 240 volts AC including seal, washers complete all as specified and as directed by Engineer-in-charge Make : Theta / Daspass or as per existing model.
Steel tank 50 ltrs as per existing model complete all as specified and as directed by Engineer-in-charge.
Steel tank 25 ltrs as per existing model complete all as specified and as directed by Engineer-in-charge.
Copper tank 50 ltrs as per existing model complete all as specified and as directed by Engineer-in-charge.
Copper tank 25 ltrs as per existing model complete all as specified and as directed by Engineer-in-charge.
MS Sheet bottom cover in two pieces duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete all as specified and as directed by Engineer-in-charge.
MS sheet top cover in two pieces duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete all as specified and as directed by Engineer-in-charge.
MS Sheet outer cover duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete all as specified and as directed by Engineer-in-charge.
Thermostate (temperature control device) for 25/50 ltrs capacity geysers complete all as specified and as directed by Engineer-in-charge. Make : Zeta / Dass pass or as per existing model
Indicating lamp with cable(Red/Green) for 25/50 ltrs capacity geysers as per existing model complete all as specified and as directed by Engineer-in-charge.
3 core flexible copper cable of size 2.5 sq mm 1100 V grade complete all as specified and as directed by Engineer-in-charge Make : Kalinga / Finolex / Plaza / Havells
3 core flexible copper cable of size 4 sq mm complete all as specified and as directed by Engineer-in-charge Make : Kalinga / Finolex / Plaza / Havells
Metal clad plug top 20/25 amps 230 Volt, Single Phase complete all as specified and as directed by Engineer-in-charge Make : Havells / HPL / Legrand
Metal clad socket 20/25 amps 230 Volt, Single Phase complete all as specified and as directed by Engineer-in-charge Make : Havells / HPL / Legrand
Single pole and neutral enclosure with a two pin and earth plug and socket 240 V complete with one single pole MCB 32 amps complete all as specified and as directed by Engineer-in-charge Make : Havells / Hager / Legrand
MCB SP 6-32 amps 230 Volt c series 50 Hz Single Phase complete all as specified and as directed by Engineer-in-charge Make : Havells / Plaza / Legrand
Socket outlet 3 pin 16 amps piano type 230 V flush type complete all as specified and as directed by Engineer-in-charge Make : Anchor / Legrand / Crabtree
Switch piano type 16 amps 230 V single pole complete all as specified and as directed by Engineer-in-charge Make : Anchor / Legrand / Crabtree
PVC plug top 3 pin 16 amps suitable for 230 volts AC supply complete all as specified and as directed by Engineer-in-charge Make : Anchor / Legrand / Crabtree
450 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and as directed by Engineer-in-charge.
600 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and as directed by Engineer-in-charge.
Pressure release valve brass chromium plated screw with 15mm bore iron pipe and suitable for 50/25 ltrs geyser complete all as specified and as directed by Engineer-in-charge.
Safety valve brass of cast alloy of screw with 15mm bore iron pipe & suitable for 50/25 ltrs geyser complete all as specified and as directed by Engineer-in-charge.
Glass wool with new glass wool as per existing density for geyser of any capacity make & model complete all as specified and as directed by Engineer-in-charge.
15mm bore non-return valve of brass chromium plated connected to iron pipe or other fittings complete all as specified and as directed by Engineer-in-charge
M&L for Removing existing paint from the steel surface of geyser of 50/25 ltrs capacity and applying two coats of synthteic enamel spray paint complete all as specified and as directed by Engineer-in-charge. Make of paint : Berger / Asian Paints / Nerolac
M & L for 15mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed by Engineer-in-charge Make : Jindal / Tata / BST
M & L for 20mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed by Engineer-in-charge Make : Jindal / Tata / BST
M&L Sub main wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 2 run of 4 sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith 1 run of 2.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete all as specified and as directed by Engineer-in-charge Make : Plaza / Kinjal / Finolex / Kalinga
M&L for point wiring complete with 2.5 sqmm single core PVC insulated unsheathed cable 100 volts grade FRLS IS-694 multi stranded copper drawn through and including non metallic rigid PVC conduit PVC conduit fittings not less than 20mm dia and conduit accessories concealed in walls roofs and floors etc including terminal boxes fabricated with 1.6mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3mmt hick fixed with cadmium plated iron screw for housing the switch socket outlet 3 pin 15 amps and including provn of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continity conductor and connection to common earth dolly complete all as specified and as directed by Engineer-in-charge. Make : Plaza / Kinjal / Kalinga / Finolex.
M&L for Dismantling,shifting of water storage heater of any make & model from one location to another location and refixing the unit with gutties/fasteners, cutting wall/concrete incl arrangement of required T&P, fixing of extra pvc flexible multistranded copper conductor of suitable size, connection of hot water pipe and GI piping and making good distributed surface complete all as specified and as directed by Engineer-in-charge
M&L for comprehensive maintenance of existing solar flat plate of cap 200/300/400/500 LPD collector of indirect heating system comprising of inspection descaling brushing and cleaning of collector panel riser tubes header tubes heat absorber tubes connecting pipes and examining of water tightness of the same after acid wash cleaning and descaling and repairing of leakage if any using welding / brazing, drain out the water from panel and tank repeating two to three times to get dirty water out etc complete all as specified and as directed by Engineer-in-charge. NOTE : - Servicing of solar water heater shall be carried once in every two months. All the comprehensive maintenance work will be carried out through original / another manufacturer of collector panel of solar water heating system only complete all as specified and as directed by Engineer-in-charge
S&F in replacement to unsv heating element of cap 3 KW suitable for solar water heater system of cap 200/300/400/500 LPD as per existing complete all as specified and as directed by Engineer-in-charge Make : Dasspass / Theta
S&F in replacement to unsv thermostate suitable for solar water heater system of cap 200/300/400/500 LPD as per existing complete all as specified and as directed by Engineer-in-charge Make : Dasspass / Elcon
M&L for Painting of steel surfaces of solar water heater system incl tank, frames etc with two coats of super enameled synthetic spray paint after preperation of old surface and making good complete all as specified and as directed by Engineer-in-charge
S&F in replacement to hose pipe for solar panel to hot water tank as per dia and thickness suitable for solar heating system of cap 200/300/400/500 LPD by clamping / tightening properly for leak proof joint complete all as specified and as directed by Engineer-in-charge
M&L for reparing of the leakage of solar hot water tank of capacity 200/300/400/500 LPD by taking down removing insulation carefully complete and taking to workshop for necessary repair by soldering /welding including replacementhing density (48kg/m3) and K value 0.03W/mk to witn stand temp. upto 250 degree celcius and insulation materials injected of thickness 100mm and refixing of its original position for satisfactory functioning of the unit complete all as specified and as directed by Engineer-in-charge
S&F in Repalacment of self priming monoblock pump set of cap. 0.5 HP single phase 220 Volts. +/_ 6% speed 2780 RPM complete all as specified and as directed by Engineer-in-charge Make : Kirloskar / CG / CRI
S&F in Repalacment of broken/rusted steel hot water SS(20 SWG)tank (inner and outer tanks)of capacity suitable for 200 LPD solar water heater including high density (48 kg/M3 ) and K value 0.03 W/mK to with stand temp. upto 250 degree celcius and insulation material injected PUF insulation of thickness 100 mm complete all as specified and as directed by Engr-in-Charge. Make : Arina / Supreme solar.
All as per item No. 70 here in above but suitable for capacity 300 LPD complete all as specified and as directed by Engineer-in-charge
All as per item No. 70 here in above but suitable for capacity 400 LPD complete all as specified and as directed by Engineer-in-charge
All as per item No. 70 here in above but suitable for capacity 500 LPD complete all as specified and as directed by Engineer-in-charge
S & laying Hot water pipe duly (GI) insulated with glass wool and aluminium clading 32mm bore with connected accessories complete all as specified and as directed by Engineer-in-charge
S&F Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 32mm bore pipe with connected accessories complete all as specified and as directed by Engineer-in-charge Make : Sant / Zolato / Kartar
S&F Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25mm bore pipe with connected accessories complete all as specified and as directed by Engineer-in-charge Make : Sant / Zolato / Kartar
S&F Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20mm bore pipe with connected accessories complete all as specified and as directed by Engineer-in-charge Make : Sant / Zolato / Kartar
S&F Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and as directed by Engineer-in-charge Make : Sant / Zolato / Kartar
S&laying of XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross-sectional area 16 sq mm 4 core complete all as specified and as directed by Engineer-in-charge Make : Havells / Plaza / Finolex / Kalinga
S&F NRV 20mm dia made out of brass complete all as specified and as directed by Engineer-in-charge
S&F NRV 32mm dia made out of brass complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MS dead flange for plate collector of solar water heater panels as per existing size with gasket along with connected accessories complete all as specified and as directed by Engineer-in-charge.
S&F in replacement gasket for flate plate collector of solar water heater as per existing size along with connected accessories complete all as specified and as directed by Engineer-in-charge. Make : Arina / Supreme Solar
S&F in replacement float valve for 15mm dia along with connected accessories complete all as specified and as directed by Engineer-in-charge.
M&L for rewinding of blower motor single phase 230 V of air curtain of any make,door opening size and air velocity with super enamelled copper winding wire including replacement of bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of blower unit/aluminium alloy fans as per existing for air curtain any make,door opening size and air velocity complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of blower motor as per existing for air curtain any make,door opening size and air velocity complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 50mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 40mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 32mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 25mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of toughened glass 6mm thick suitable for existing solar flat plate collector of any size complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of indoor unit for split type AC complete with motor, blower, remote control, filters having cooling capacity 6000 K.Cal/Hr hi wall split units indoor copper tube unit capacity of 2 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 2 Ton fitted on wall requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty along with bill.
S&F in replacement of indoor unit for split type AC complete with motor, blower, remote control, filters having cooling capacity 4500 K.Cal/Hr hi wall split units indoor copper tube unit capacity of 1.5 Ton complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty along with bill.
S&F in replacement of outdoor unit for split type AC complete of capacity 6000 K.Cal/Hr with charging valves and gas filter with compressor complete Supply and install hi wall split units outdoor copper tube evaporator and condencing unit capacity of 2 Ton complete with minimum 3 star rating and EER 3.2.of capacity 2 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping, stands of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty alomg with bill.
S&F in replacement of outdoor unit for split type AC complete of capacity 6000 K.Cal/Hr with charging valves and gas filter with compressor complete Supply and install hi wall split units outdoor copper tube evaporator and condencing unit capacity of 1.5 Ton complete with minimum 3 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping, stands of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star/Hitachi Note:- Contractor shall be submitted minimum 2 years warranty alomg with bill.
Notes (a) Contractor will provide well experienced and well conversed men power (02 AC Mech+ 01 Geyser Tech+03 Helper) including Sunday & Holidays. (b) The Refg Mech should 10th passed having 4 year experience in the trade or ITI holder in the relevant trade having proper knowledge for repairing work of Refg & AC items.(c) All T&P required for repair work shall be provided by contractor at own arrangement to trade men & helpers (d) All complaints should be attended with in 24 hours. Panelty charges for non attending complaints within 24 hours shall be Rs. 300/- per complaint. The cost of man power shall be deemed to be included in the unit rate.
J.P. Enterprises
HONEY COLLECTION
Saini Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .