Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC AT PRATAP BAGAN LANE NO 07 P O BANKURA DIST BANKURA PIN 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹3.0 L+₹378 (0.13%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹3.0 L+₹714 (0.24%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹6,970
Closing Date
12 Sept 2025, 12:55 pmClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Supply Installation of New Split AC machine for Bronchoscope room at Female Chest Medicine of Main Building of BSMC and H , including necy electrical installation work.
2025_WBPWD_897796_1
WBPWDTE/AE/BMCESD/NIQ-16/Q of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹6,970
Yes
31 Oct 2025
2 Sept 2025
15 Sept 2025
2 Sept 2025
12 Sept 2025
2 Sept 2025
Amount
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in 20 / 25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 2.5 sq mm + 1 x 1.5sq mm ( for computer board, Power plug)
2 x 4 sqmm + 1 x 2.5sqmm (For AC Points)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], and drop Concealed type if reqd as per direction of EIC with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar ncl. bakelite/ Perspex top cover 3 mm thick and incl. 175 mm x100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 12 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) 19mm bore, 3mm thick polythene pipe, with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish . On Board
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 20 0x 65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Delivery of 4 feet twin commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 501 P2 x T - LED 22 W P3 242 with 2 nos x Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Wipro / Bajaj / Crompton/ Havells / PWD approved as per direction of EIC
Supply & Fixing of 250V 50 HZ OLP- 30A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing Timer panel made of 16 way Distribution Board with transperent front door and din rail for mounting the following items included. per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer similar to ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no B) One no. ML-3 conctractor,(L&T make) with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no C) 4 pole 32 Amps MCB ( L & T / Ligrand ) - 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V, Diode type neon Indicator lamp ( Make: Legrand /L&T) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling AC Machine) (Make - Legrand /L & T / Crabtree )
Supply & Delivery of 230V, 50Hz 3 Star rated 2.0 ton capacity Split Air-conditioner machine fitted with Hyper Tropical Rotary compressors suitable for Refrigerant-R410A/ R32, Standrad Colling Capacity 6450 W Power Consumption Capacity 1870W Moisture Removal 2.3 I/H Air Flow 1060 Cu.Mt/Hr. (Make- O-General Model-AOGG22CKTC-B or equvalent model of Hitachi/Daikin/ PWD Appvd ) with Remote etc . to complete with 25 Amp suitable plug top (North West / appvd ) as per direction of EIC)
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Febrication of iron Bracket/ platform which consist of five nos.75 x 40 x 5 mm 'C' channel aprox length of each 1.4mtr. as main support, 50 x 50 x 6 mm iron angle for main frame & cross angle support from wall to structure, 25 x25 x 5 mm iron angle for safty guarding fram, 25 x25 x 5 mm iron angle for making 450mm wide both side platform of out door unit for future maintenance work, it should have the facility to install Two outdoor unit of split AC machine at middle of the bracket and sufficent space should be maintained both side of the outdoor unit for maintenance work also have suitable angle support between wall & bracket and painting the same incl. drilling holes in each Angle including cutting holes into the wall & grouting the same with (1:1 ½ :3) cement concrete etc. and painting the same as per direction of EIC.
Swarnendu Sarkar (BID ID -6904533)
TAPAN KUMAR SARKAR (BID ID -6904543)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .