Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance NO 7A MULLAI NAGAR MAIN RD WEST TAMBARAM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance NO 1 KAMAM STREET SELAIYUR CHENNAI 600073 | CHENNAI | CHENNAI | TAMIL NADU | 600073 | Admitted-Finance |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
26 Jun 2024, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIRS TO INTERNAL ELECTRIFICATION AT MADAMBAKKAM, NARENDRA PLACE AND 9 P S UNIT UNDER AF STATION TAMBARAM
2024_MES_656295_1
8726/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹56,000
Yes
28 Jun 2024
30 May 2024
28 Jun 2024
30 May 2024
26 Jun 2024
14 Jun 2024
30 May 2024 - 6 Jun 2024
Amount
Taking down carefully copper / aluminum point wiring (light, fan, socket or power) complete except conduit (fittings such as switches, ceiling roses, regulators, sockets etc., to be measured seperately) and making good disturbed surface of wall, floors etc., complete all as specified and directed.
M&L for Point wiring complete with 1.5sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through existing conduit and MS pressed steel terminal boxs with new 3 mm thick hylam sheet suitable for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly complete all as specified and directed.for for One light / fan point controlled by one 5 Amps switch.
All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on same board
All as per Item No 2 above but for One 3 pin 5 Amps socket outlet on independent board
All as per Item No 2 above but for One call bell point controlled by one bell push
All as per item No 2 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sqmm size.
M&L for Point wiring complete with 1.5sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through PVC casing & caping / PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxs concelled/surface in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.5sqmm PVC insulated copper conductor for continious earth wire and connected to common earth dolly complete all as specified and directed for for One light point / fan point controlled by one 5 Amps switch.
All as per Item No.7 above but for One 3 pin 5 Amps socket outlet on same board
All as per Item No.7 above but for One 3 pin 5 Amps socket outlet on independent board
All as per Item No.7 above but for One call bell point controlled by one bell push
All as per item No.7 above but for one 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
All as per item No.7 above but for one 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size.
Supply and fix in repairs including disconnecting, removing and connecting into electric circuit and testing complete all as specified and directed for the following items:-All as per Item No.4 above but fo Modular switch 1 way 6A, 1 module all as specified and directed . (Anchor Roma,Havells,legrand)
All as per Item No.13 above but for Modular switch 1 way 16A, 1 module all as specified and directed. (Anchor Roma,Havells,legrand)
All as per Item No.13 above but for Modular socket 6A 3 pin combined 2 module all as specified and directed. (Anchor Roma,Havells,legrand)
All as per Item No.13 above but for Modular socket 6A/16A 2/3 pin combined 2 module all as specified and directed. (Anchor Roma,Havells,legrand)
All as per Item No.13 above but for Modular Fan regulator 120 W 2 Module suitable for 1200mm/1400mm sweep fan all as specified and directed. (Anchor Roma,Havells,legrand)
All as per Item No.13 above but for Switch piano type 5 Amps ,Single pole one way all as specified and directed.
All as per Item No.13 above but for Switch socket comination type 2 in 1, 3 pin 5 Amps 240 V all as specified and directed.
All as per Item No.13 above but for Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal.all as specified and direcetd.
All as per Item No.13 above but for Fan regulator stepped type electronic flush/switch type, suitable for 1200mm /1400 mm sweep fan.all as specified and directed.
All as per Item No.13 above but for PVC ceiling rose two to three terminal plate and jumbo type all as specified and directed..
All as per Item No.13 above but for Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
All as per Item No.13 above but for Bell push Flush type 5 Amps all as specified and directed.
All as per Item No.13 above but for Call bell 230 volts single pole A/C multimusic fancy type ding dong bell.all as specified and directed..
Supply and fix in replacement of laminated sheet 3 mm thick of size 4''x4'' for mounting switches,sockets,fan regulator etc. all as specified and directed.
Supply and fix in replacement of laminated sheet 3 mm thick of size 12''x8''for mounting switches,sockets,fan regulator etc. all as specified and directed.
Supply and fix, in replacement of MCB DB SPN, double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link.all as specified and directed..
Supply and fix in replacement for MCB DB TPN 4 way vertical type double door complete including 200A rated copper bus bar, and neutral and earth link suitable for MCB TPN as incommer.all as specified and directed all as per make (legrand/,L&T/Havells)
Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door type including 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections all directed by Engr in charge
supply and fix in replacement of Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volts all as specified and directed,
supply and fixing in replacement for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz all as specified and directed
supply and fixing in replacement of MCB SPN 32 Amps 10KA 240 volts all as specified and directed
supply and fixing in replacement of MCB TP 63 Amps 10KA 415 volts all as specified and directed
supply and fix in replacement of MCB TPN 63 Amps 10KA 415 volts all as specified and directed all as per make (legrand/,L&T/Havells)
supply and fix in replacement of MCB TP 100 Amps 10KA 415 volts as per make (legrand/,L&T/Havells)
Supply and fix MCCB 100 Amps 3 pole 16 KA breaking capacity 415 Volts fixed in repairs all as specified and directed.
Taking down existing sub main wiring any description along with PVC conduit/ casing capping and made good the disturbed surface all as specified.
M & L for circuit/sub main wiring complete with 2 X 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories with 1 X 1.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed.
M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed.
M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed.
M & L for circuit/sub main wiring complete with 2 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified and directed. Note for Sl items No.38 to 42 : Two runs of cable and one run of earth continuity cable shall be measured as one unit.
Supply and fix in replacement of LED 36 Watt fitting aesthetically Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling designed 2'x2' flat pannel suitable to false ceiling including provision of three core suitable flexicable PVC wire from ceiling rose to fittings all as directed. Make :- Havells Cat part No PLANO2X2PLR36WLED865TAPS or Equivalent
S & F in replacement of LED batten, Light fitting extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 20 W LED lamp including disconecting, removing, and connecting all as directed. Make: Havells Cat No : LUMINEPLUSNEOBS20WLDE865SPCSSIND / Equivalent
S & F in replacement of LED batten, Light fitting extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 18 W LED lamp including disconecting, removing, and connecting all as directed. Make: Havells Cat No : LUMINEPLUSNEOBS 18WLED865SPCSSIND / Equivalent
Supply and fix in relacement of surface and wall mounted 10 Watt LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as directed. . Make : Havells Cat No.LUMILINEBS10WLED865SPCSSIND or Equivalent
Supply and fix in replacement for Bldg security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 25 W LED all as per including disconecting, removing,and testing all as directed. Make :Havells Cat No ENDURASUNDOWNSL25WLED765PASYBOPC or equivalent . .
Supply and fix in replacement for Bldg security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 40W LED all as per including disconecting, removing,and testing all as directed. Make :Havells Cat No ENDURASUNDOWNSL40WLED765PASYBOPC or equivalent . .
S&F in replacemnt of post top 25 Watt light fittings LED POST TOP new generation IP 65 led post of family,energy saving, environmental friendly,long life aesthetically designed with symertical light distrubution,spun aluminium landscap luminaire with high power LEDs as light source.Opal cover offers soothing uniform illumination for different application all as diected. Make : Havells CatNo: CORALPT25WLED830SSYMTOPC or Equivalent
Supply and fix in replacement Bulk head fitting 10 watt PDC housing LED lumininaire with opal diffuser,equipped with 2 KV in built surge protection with IP 65 protection rating all directed Make: Havells / Equivalent Cat No : HEXAFT10WLED857SSYMBOPC
Supply and fix in replacement of LED Lamp 9W, suitable of B22, 240V all as specified and directed. Make Havells / Equivalent
Supply and fix in replacement PL lamp 18 watt sutiable for 2 X 2 recess mounted light fittings all as directed. . Make : Havells Cart part No HERCULESPLL419TL18WLED865SPC or equivalant
M&L in replacement for GI Bracket bend to shape in cold or hot 25mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, for fixing security light fittings to Bldgs complete all directed.
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0mmdia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work shall inclusive of necessary earth work and PCC chamber 1:3:6 in type CI with 8mm CTD bar reinforcement both ways at 140 mm bents to centre complete all as specified and directed including taking down old unserviceable earthing .
Cutting chases, pinning in making good to facings where required and pointing in cement motor 1:3 to ends or edges of landings steps, chills, sunshades, shelves, lintels etc and cutting chases for concealed conduit wiring etc. and making good cutting exceeding 10cm but not exceeding 20cm girth complete.
Material and labour for steel terminal boxes 100mm x 100mm x 60mm deep for mounting, switches, sockets fan regulator,etc with 3mm thick plastic laminated sheet cover all as specifed and directed.
Material and labour for steel terminal boxes 200mm x 300mm x 60mm deep for mounting, switches, sockets fan regulator,etc with 3mm thick plastic laminated sheet cover all as specifed and directed.
Taking down carefully Existing ceiling fan/exhaust fan/wall Mounted fan of any size/ Make after disconnecting the electrical connection etc.all as specified and directed
Refixing ceiling fan any size/make replacing the spares such as carter pin Unserviceable/Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, etc.and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified and directed. Note:- Rewinding, spare parts such as ball bearing, capacitor, bush etc., required to make the ceiling fan serviceable shall be measured paid seperately under relevent items. Note: Refixing fan shall be tested after fixing the blades
Refixing Exhaust fan along with louvers replacing the spares such as carter pin Unserviceable /Rusted nut bolts etc.and connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified Note:- Rewinding,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items. Note: Refixing fan shall be tested after fixing the blades
Material and labour for rewinding of celing fan motor with super enameled copper winding wire of same gauge and weight after cutting and removing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating materials for celing fan 1200mm / 1400 mm sweep.
All as per item No 61 here-in- before but for exhaust fan 225 to 300mm sweep / wall mounted fan of any sweep.
Supply only ball bearing size suitable for ceiling fans size 1200/1400 mm Sweep complete all as specified and directed.
Supply only ball bearing Size suitable for exhaust fan/ wall mounted fan of any size and make, complete all as specified and directed.
supply only capcitor of capacity 2.5 mfd for the fans in position complete all as specified and directed.
supply and fix in replacement exhaust fan louvers size (300 mm) suitable for Exhaust fan all as specified and directed..
Supply only fan blade suitable for (300 mm ) exhaust fan all as specified and directed.
supply only BLDC ceiling fan PCB board suitable for any type/model ceiling fan 1200 mm sweep 230 Volt 50 Hz all as specified and directed .
Material & labour for Cleaning and preparing the surface of ceiling fan of any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat synthetic enamel paint painting of ceiling fan with two coats of synthetic enamel white paint of approved colour by spraying including preparation of old painted surface & writing of MES No on the fan complete all as specified and directed.
Taking down carefully storage type water heater (Geyser)of any type and make up to 25 /50 Ltrs capacity after disconnecting all Electrical connecting,descaling the inner container heating element base assembly etc by using diluted hydrochloric acid and cleanning thoroughly,filling the inner container with water and checking leakage if any reasembling the geyser after of leakage by bracing and electric and water supply lines,refixing and testing on completion all as specified and directed (Note:-spares shall be measured and paid saperately under relevent items of this Schedule)
Supply only Heating Elements with rubber gasket thread/push type 230V, 2 KW (Make:-Bajaj/Usha/Racold)
Supply only Thermostart suitable for Geysers 25 Ltrs capasity,and temp range 30 to 80 degree centigrade and cut off at 70 degree centigrade all as specified and directed.
Supply PVC insulated multicore flexible copper conductor cable sheathed FRLS of size 4 sqmm, 3 core complete all as specified.
Supply and fix in replacement 3 pin plug top, 16 Amp all as specified.
Supply and fix PVC Connecting pipe 15 mm dia 450 mm long heavy duty suitable for hot/cold water with two brass union and washers completed all directed.
Supply and fix in repairs, ceiling fan down rod size of 15 mm dia GI pipe medium grade duly cutting/threading /drilling etc.suitable for check nuts and split pin including U clamp bolts,nuts,washers,rubber split pin check nutsetc suitable for ceiling fan 1200 mm sweep incl taking down of unserviceable complete all as specified.
Supply and fix in repairs, ceiling fan clamp / hook made out of MS flat iron 40x6 mm bent to shape fixing to 50 mm GI pipe for hanging ceiling fan incl taking down unserviceable complete all as specified.
Disconnecting, removing carefully the 5 nos electronic meter from existing Meter box and refixing the same with provision of Hylam sheet size of 900 x 600 x 6 mm for fixing the retrieved meters on the existing meter box complete. Note : Thequoted rate is deemed to include for suitable wires for connecting meters to DB.
Vishwa Enterprises
SJM CONSTRUCTIONS
ragavbuilders
M/s Bakiyalakshmi Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .